首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
The chromatographic behavior of 8 ionic liquids - 7 homologues of 1-alkyl-3-methylimidazolium and 4-methyl-N-butylpyridinium - has been investigated with a strong cation exchange adsorbent. In particular, the dependence of the retention properties of these solutes on mobile phase composition, pH, and buffer concentration was evaluated with the aim of optimizing and improving the selectivity and retention of solute separation. While using the SCX stationary phase, several interactions occurred with varying strengths, depending on the mobile phase composition. Cation exchange, nonspecific hydrophobic interactions, and adsorption chromatography behavior were observed. Reversed phase chromatography occurred at low concentrations of acetonitrile, electrostatic and adsorption interactions at higher organic modifier concentrations. Elevated buffer concentrations lowered the retention factors without affecting the selectivity of ionic liquids. Obtained results were further compared to the chromatographic behaviour of ionic liquids in the reversed phase system. All analyzed ionic liquids follow reversed-phase behavior while being separated. Much lower selectivity in the range of highly hydrophilic compounds is obtained. This suggests preferred use of ion chromatography for separation and analysis of compounds below 4 carbon atoms in the alkyl side chain.  相似文献   

2.
以甲基丙烯酰氧乙基二甲基乙酸铵(CBMA)为功能单体,利用表面引发原子转移自由基聚合(Surface-initiated atom transfer radical polymerization, SI-ATRP)技术,将CBMA接枝到硅胶表面,得到接枝聚合物CBMA的亲水作用色谱固定相(Silica-CBMA).通过改变SI-ATRP反应体系中单体的浓度,制备了3种不同接枝量的亲水作用色谱固定相.考察了Silica-CBMA固定相对有机酸类化合物的分离性能以及流动相中pH值、盐浓度、水含量等因素对溶质保留行为的影响.结果表明,在亲水作用色谱模式下,Silica-CBMA固定相对有机酸类化合物的分离是离子交换作用与亲水作用的混合色谱模式.流动相中盐浓度增大,溶质保留减弱,符合离子交换作用特征;固定相和溶质的离子化程度受流动相pH值影响较大,pH值增大,溶质保留增强;而溶质的保留时间随流动相水含量增加而降低则是典型的亲水作用色谱特征.使用自制Silica-CBMA柱,建立了芦丁片中维生素C、芦丁含量的亲水作用色谱测定方法,操作方法简单,为强极性样品的分离测定提供了新方法.  相似文献   

3.
A stationary phase composed of silica-bonded cyclofructan 6 (FRULIC-N) was evaluated for the separation of four cyclic nucleotides, six nucleoside monophosphates, four nucleoside diphosphates, and five nucleoside triphosphates via hydrophilic interaction chromatography (HILIC) in both isocratic and gradient conditions. The gradient conditions gave significantly better separations by narrowing peak widths. Sixteen out of nineteen nucleotides were baseline separated on the FRULIC-N column in one run. Unlike other known HILIC stationary phases, there can be dual-retention mechanisms unique to this media. Traditional hydrogen bonding/dipolar interactions can be supplemented by dynamic ion interaction effects for anionic analytes. This occurs because the FRULIC-N stationary phase is able to bind certain buffer cations. The extent of the ion interaction is tunable, in comparison to stationary phases with embedded charged groups, where the inherent ionic properties are fixed. The best mobile phase conditions were determined by varying the organic modifier (acetonitrile) content, as well as salt type/concentration and electrolyte pH. The thermodynamic characteristic of the FRULIC-N column was investigated by evaluating the column temperature effect on retention and utilizing van’t Hoff plots. This study shows that there is a greater entropic contribution for the retention of nucleotide di and triphosphates, whereas there is a greater enthalphic contribution for the cyclic nucleotides with the FRULIC-N column.  相似文献   

4.
The retention characteristics of a silicon oxynitride stationary phase for carbohydrate separation were studied in hydrophilic interaction chromatography mode. Four saccharides including mono‐, di‐, and trisaccharides were employed to investigate the effects of water content and buffer concentration in the mobile phase on hydrophilic interaction liquid chromatography retention. For the tested saccharides, the silicon oxynitride column demonstrated excellent performance in terms of separation efficiency, hydrophilicity, and interesting separation selectivity for carbohydrates compared to the bare silica stationary phase. Finally, the silicon oxynitride hydrophilic interaction liquid chromatography column was employed in the separation of complex samples of fructooligosaccharides, saponins, and steviol glycoside from natural products. The resulting chromatograms demonstrated good separation efficiency and longer retention compared with silica, which further confirmed the advantages and potential application of silicon oxynitride stationary phase for hydrophilic interaction liquid chromatography separation.  相似文献   

5.
Effects of mobile-phase variations on the chromatographic separation on amino-bonded silica column in hydrophilic interaction chromatography (HILIC) were investigated for four zwitterionic tetracyclines (TCs): oxytetracycline, doxycycline, chlortetracycline, and tetracycline. A mixed-mode retention mechanism composed of partitioning, adsorption, and ion exchange interactions was proposed for the amino HILIC retention process. Buffer type and pH significantly influenced the retention of TCs, but showed similar separation selectivity for the tested analytes. Experiments varying buffer salt concentration and pH demonstrated the presence of ion exchange interactions in TCs retention. The type and concentration of organic modifier also affected the retention and selectivity of the analytes, providing direct evidence supporting the Alpert retention model for HILIC. The retention time of the analytes increased in the following order of organic modifiers: tetrahydrofuran < methanol < isopropanol < acetonitrile. The linear relationships of logk' versus %water (v/v) curve and logk' versus logarithm of %water (v/v) in the mobile phase indicated that TCs separation on the amino phase was controlled by partitioning and adsorption. The developed method was successfully utilized in the detection of TCs in both river water and wastewater samples using solid-phase extraction (SPE) for sample cleanup.  相似文献   

6.
Unbonded silicon oxynitride and silica high‐performance liquid chromatography stationary phases have been evaluated and compared for the separation of basic compounds of differing molecular weight, pKa, and log D using aqueous/organic mobile phases. The influences of percentage of organic modifier, buffer pH, and concentration in the mobile phase on base retention were investigated on unbonded silicon oxynitride and silica phases. The results confirmed that unbonded silicon oxynitride and silica phases demonstrated excellent separation performance for model basic compounds and both the unbonded phases examined possessed a hydrophobic/adsorption and ion‐exchange character. The silicon oxynitride stationary phase exhibited high hydrophilicity compared with silica with a reversed‐phase mobile phase. An ion‐exclusion‐type mechanism becomes predominant for the separation of three aimed bases on the silicon oxynitride column at pH 2.8. Different from silicon oxynitride stationary phase, no obvious change for the retention time of three model bases on silica stationary phase at pH 2.8 can be observed.  相似文献   

7.
New stationary phases for hydrophilic interaction liquid chromatography (HILIC) were synthesized by covalently attaching native cyclofructan 6 (CF6) to silica gel. The chromatographic characteristics of the new stationary phases were evaluated and compared to three different types of commercial HILIC columns. The CF6 columns produced considerably different retention and selectivity patterns for various classes of polar analytes, including nucleic acid compounds, xanthines, β-blockers, salicylic acid and its derivatives, and maltooligosaccharides. Univariate optimization approaches were examined including organic modifier (acetonitrile) contents and buffer pH and salt concentration. The thermodynamic characteristic of the CF6 stationary phase was investigated by considering the column temperature effect on retention and utilizing van't Hoff plots. CF6 based stationary phases appear to have exceptionally broad applicability for HILIC mode separations.  相似文献   

8.
In an effort to gain insight into the relationship between stationary phase solvation and selectivity, the use of short- and medium-chained-length alcohols (methanol, n-propanol, n-butanol, and n-pentanol) as mobile phase modifiers in reversed-phase liquid chromatography (RPLC) was investigated to determine their impact on chromatographic selectivity. A wide range of mobile phase compositions was evaluated because of the large effect exerted by solvent strength on selectivity. Employing a set of six vanillin compounds as retention probes, evidence is presented to support the view that an increase in the hydrophobicity of the organic modifier used in RPLC can increase the selectivity of the C18 alkyl bonded phase while simultaneously decreasing the retention time of the eluting solutes. Thus, we are presented with an interesting paradox: higher selectivity and shorter retention times, which can be attributed to changes in either solvent selectivity and/or stationary phase solvation by the organic modifier.  相似文献   

9.
Small organic acids have shown significant retention on various stationary phases, such as amide, amino, aspartamide, silica and sulfobetaine phase commonly used in hydrophilic interaction chromatography (HILIC). This study investigated the effect of chromatographic conditions on the retention behavior of organic acids in HILIC using the tool of design of experiment (DOE). The results of the DOE study indicated that both the content of organic solvent (i.e., acetonitrile) and salt concentration in the mobile phase had significant effects on the retention of organic acids. Higher content of organic solvent in the mobile phase led to a significant increase in retention on all types of stationary phases. Increasing salt concentration also resulted in a moderate increase in retention; however, the effect of salt concentration varied with the type of stationary phase. The study also revealed that column temperature had less impact on retention than organic solvent content and salt concentration in HILIC.  相似文献   

10.
目前,万古霉素色谱分析方法主要为反相色谱法,该法分离万古霉素及其杂质时,存在极性选择性不足以及所使用的流动相体系与质谱兼容性差等问题。基于亲水作用色谱(HILIC)对糖肽类物质的色谱保留和极性选择性,本文选取万古霉素及其常见杂质为对象,考察了HILIC固定相、流动相组成比例、缓冲盐添加剂浓度和pH值等色谱条件,对万古霉素及其主要杂质进行了HILIC分离方法研究。确立了以Click XIon色谱柱为固定相,以甲酸铵为流动相添加剂的亲水作用色谱条件,实现了万古霉素及主要杂质的分离,为万古霉素类化合物的分离提供了新的途径。  相似文献   

11.
The separation of several insect oostatic peptides (IOPs) was achieved by using CEC with a strong-cation-exchange (SCX) stationary phase in the fused-silica capillary column of 75 microm id. The effect of organic modifier, ionic strength, buffer pH, applied voltage, and temperature on peptides' resolution was evaluated. Baseline separation of the studied IOPs was achieved using a mobile phase containing 100 mM pH 2.3 sodium phosphate buffer/water/ACN (10:20:70 v/v/v). In order to reduce the analysis time, experiments were performed in the short side mode where the stationary phase was packed for 7 cm only. The selection of the experimental parameters strongly influenced the retention time, resolution, and retention factor. An acidic pH was selected in order to positively charge the analyzed peptides, the pI's of which are about 3 in water buffer solutions. A good selectivity and resolution was achieved at pH <2.8; at higher pH the three parameters decreased due to reduced or even zero charge of peptides. The increase in the ionic strength of the buffer present in the mobile phase caused a decrease in retention factor for all the studied compounds due to the decreased interaction between analytes and stationary phase. Raising the ACN concentration in the mobile phase in the range 40-80% v/v caused an increase in both retention factor, retention time, and resolution due to the hydrophilic interactions of IOPs with free silanols and sulfonic groups of the stationary phase.  相似文献   

12.
Hydrophilic interaction liquid chromatography (HILIC) was examined for the separation of paralytic shellfish poisoning (PSP) toxins using the stationary phase TSK-gel Amide-80. The parameters tested included type of organic modifier and percentage in the mobile phase, buffer concentration, pH, flow rate and column temperature. Using mass spectrometric (MS) detection, the HILIC column allowed the determination of all the major PSP toxins in one 30 min analysis with a high degree of selectivity and sensitivity. The high percentage of organic modifier in the mobile phase and the omission of ion pairing reagents, both favored in HILIC, provided limits of detection (LOD) in the range 50-100 nM in selected ion monitoring (SIM) mode on a single quadrupole LC-MS system. LOD in selected reaction monitoring (SRM) mode on a sensitive triple quadrupole system were as low as 5-30 nM. Excellent linearity of response was observed.  相似文献   

13.
Hydrophilic interaction chromatography has been applied for the separation of epirubicin and its analogues using high-purity silica column with aqueous-organic mobile phase. Parameters affecting the chromatographic behavior of the solutes such as organic modifier, buffer pH, ionic strength and sample size, have been investigated. Of utmost importance for successful separation of these analogues is the choice of organic modifier, since it impacts both the solvent selectivity and the ionization of silica silanols as well as buffer solution, and consequently the retention behavior of solutes. Acetonitrile was shown to offer superior separation of these analogues to methanol, isopropanol or tetrahydrofuran. Results of the effects of organic modifier, buffer pH and ion strength indicate that the retention mechanism is a mixed-mode of adsorption and ion exchange. In addition, an irreversible adsorption of these compounds was found on silica in the weakly acidic or neutral mobile phases, and the effect of various factors on irreversible adsorption was also preliminarily discussed. More significantly, these basic compounds have exhibited peaks with a slanted front and a sharp tail, a typical overloading peak profile belonging to the behavior of competitive anti-Langmuir isotherm by increasing the sample size at the experimental conditions.  相似文献   

14.
The current work is focused on exploring the effect of buffer cation type and its concentration on retention of amino acids, dipeptides and their blocked analogues on two stationary phases, i.e., bare silica and amide-based in hydrophilic interaction liquid chromatography. Five different buffers of pH 4.0 composed of Tris/acetic acid, triethylamine/acetic acid, ammonium/acetic acid, Li+/acetic acid and Ba2+/acetic acid were used in various concentrations. Interestingly, an increase of the buffer concentration caused increasing, decreasing or stable retention of analytes, according to the cation type in the buffer. The buffers containing barium cations provided the highest retention of all the analytes in comparable mobile phases, i.e., buffers with the same ionic strength and pH on both columns. Moreover, using buffers with barium cation different selectivity for dipeptides was observed. The chromatographic systems with buffers consisting of triethylamine behaved differently compared to others.  相似文献   

15.
Separation of the two enantiomers of racemic α‐ and β‐amino acids on two ligand exchange chiral stationary phases (CSPs) prepared previously by covalently bonding sodium N‐((S)‐1‐hydroxymethy‐3‐methylbutyl)‐N‐undecylaminoacetate or sodium N‐((R)‐2‐hydroxy‐1‐phenylethyl)‐N‐undecylaminoacetate on silica gel was studied with variation of the organic modifier (methanol) concentration in the aqueous mobile phase. In particular, the variation of retention factors with changing organic modifier concentration in the aqueous mobile phase was found to be strongly dependent on both the analyte lipophilicity and the stationary phase lipophilicity. In general, the retention factors of relatively lipophilic analytes on relatively lipophilic CSPs tend to increase with increasing organic modifier concentration in the aqueous mobile phases while those of less lipophilic or hydrophilic analytes tend to increase. However, only highly lipophilic analytes show decreasing retention factors with increasing organic modifier concentration in the aqueous mobile phase on less lipophilic CSPs. The contrasting retention behaviors on the two CSPs were rationalized by the balance of the two competing interactions, viz. hydrophilic interaction of analytes with polar aqueous mobile phase and the lipophilic interaction of analytes with the stationary phase.  相似文献   

16.
The separation and determination of hydrophilic basic compounds are of great importance in many fields including clinical and biological research, pharmaceutical development and forensic analysis. However, the most widely used analytical separation technique in these disciplines, reversed-phase liquid chromatography (RPLC), usually does not provide sufficient retention for several important classes of highly hydrophilic basic compounds including catecholamines, many drug metabolites and many drugs of abuse. Commonly eluents having little or no organic modifier and/or strong ion pairing agents must be used to achieve sufficient retention and separation. Use of highly aqueous eluents can lead to column failure by dewetting, resulting in poor retention, low selectivity and irreproducibility and slow recovery of performance. The use of a strong ion pairing agent to increase retention renders the separation incompatible with mass spectrometric detection and complicates preparative separations. This paper describes the successful applications of a novel type of silica-based, hyper-crosslinked, sulfonate-modified reversed stationary phase, denoted as (-)SO(3)-HC-C(8)-L, for the separation of highly hydrophilic cations and related compounds by a hydrophobically assisted cation-exchange mechanism. Compared to conventional reversed-phases, the (-)SO(3)-HC-C(8)-L phase showed significantly improved retention and separation selectivity for hydrophilic amines. Concurrently, due to the presence of both cation-exchange and reversed-phase retention mechanisms and the high acid stability of hyper-crosslinked phases, the separation can be optimized by changing the type or concentration of ionic additive or organic modifier, and by varying the column temperature. In addition, gradients generated by programming the concentration of either the ionic additive or the organic modifier can be applied to reduce the analysis time without compromising resolution. Furthermore, remarkably different chromatographic selectivities, especially toward cationic solutes, were observed upon comparing the (-)SO(3)-HC-C(8)-L phase with conventional reversed-phases. We believe that the combination of these two types of stationary phases will be very useful in two-dimensional liquid chromatography.  相似文献   

17.
Lin J  Huang G  Lin X  Xie Z 《Electrophoresis》2008,29(19):4055-4065
A novel porous polymethacrylate-based monolithic column by in situ copolymerization of 3-sulfopropyl methacrylate (SPMA) and pentaerythritol triacrylate in a binary porogenic solvent consisting of cyclohexanol/ethylene glycol was prepared. The monolith possessed in their structures bonded sulfonate groups and hydroxyl groups and was evaluated as a hydrophilic interaction and strong cation-exchange stationary phases in capillary liquid chromatography (cLC) and pressure-assisted CEC using small polar neutral and charged solutes. While the SPMA was introduced as multifunctional monomer, the pentaerythritol triacrylate was used to replace ethylene glycol dimethacrylate as cross-linker with much more hydrophilicity due to a hydroxyl sub-layer. The different characterization of monolithic stationary phases were specially designed and easily prepared by altering the amount of SPMA in the polymerization solution as well as the composition of the porogenic solvent for cLC and pressure-assisted CEC. The resulting monolith showed the different trends about the effect of the permeabilities on efficiency in the pressure-assisted CEC and cLC modes. A typical hydrophilic interaction chromatography mechanism was observed at higher organic solvent content (ACN%>70%) for polar neutral analytes. For polar charged analytes, both hydrophilic interaction and electrostatic interaction contributed to their retention. Therefore, for charged analytes, selectivity can be readily manipulated by changing the composition of the mobile phase (e.g., pH, ionic strength and organic modifier). With the optimized monolithic column, high plate counts reaching greater than 170 000 plates/m for pressure-assisted CEC and 105 000 plates/m for cLC were easily obtained, respectively.  相似文献   

18.
The retention mechanism and chromatographic behavior for different polar analytes under hydrophilic interaction chromatography (HILIC) conditions have been studied by application of different mobile phases and stationary phases to various analytes at different temperatures. In addition to the commonly accepted mechanism of analyte liquid-liquid partitioning between mobile phase and water-enriched solvent layer which is partially immobilized onto the surface of the stationary phase, hydrogen-bonding, hydrophobic interaction, and ion-exchange interactions may also be involved. The predominant retention mechanism in HILIC separation is not always easily predictable. It can depend not only on the characteristics of the analytes but also on the selection of mobile and stationary phase compositions. The objective of this review is to evaluate the potential application of column temperature and mobile phase composition toward improving HILIC selectivity. The functional groups from analyte structures, stationary phase materials and organic mobile phase solvents will be highlighted.  相似文献   

19.
The retention behavior of a large group of analytes (35) with varied properties (pKa and logP) was studied on eight hydrophilic interaction LC columns with different surfaces, stationary phase chemistries, and types of particles. The acetonitrile content (5–95%), buffer concentration (0.5–200 mM), and pH of the mobile phase (3.8 and 6.8) were evaluated for their effects on the retention behavior. The type of stationary phase had a significant impact on the selectivity and retention time of the tested analytes. Completely different selectivity was observed on the aminopropyl stationary phase. In this study, the influence of the buffer concentration was similar for all tested columns, except for the aminopropyl stationary phase. Increasing the buffer concentration led to decreased retention times for the basic compounds and increased retention times for the acidic compounds, while the inverse behavior was observed on the aminopropyl stationary phase. The selectivity of the individual stationary phases was evaluated at pH 3.8 and 6.8. Much lower selectivity differences between the stationary phases were observed at pH 6.8 than pH 3.8. Bare silica stationary phases were used in the comparison of the particles (fused‐core and fully porous particles of 3 and 1.7 μm) and the columns provided by different manufacturers.  相似文献   

20.
A hydrophilic interaction liquid chromatography (HILIC) method was developed for the analysis of very polar and basic 4-(aminomethyl)pyridine (4-AMP) and its related compounds. Separation parameters such as stationary phase, buffer pH, buffer ionic strength, organic modifier, and column temperature were evaluated. The retention mechanisms were explored through the evaluation of the common chromatographic parameters in the method development. The data indicated the existence of surface adsorption phenomena for 4-AMP and its positional isomers (2-AMP, 3-AMP). For two degradants, different retention mechanisms might be involved when compared to 4-AMP. The selectivity of two critical pairs 3-/4-AMP isomer and Degradant-1/-2 diastereomer changed through isoelution temperature with reversal of elution order. The validation results indicated that the HILIC method is a sensitive, reproducible, and robust method suitable for the analysis of 4-AMP and its related compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号