共查询到20条相似文献,搜索用时 0 毫秒
1.
A carbon paste electrode modified with electropolymerized fills of isonicotinic acid was developed.The modified electrode shows excellent electrocatalytic activity toward the oxidation of both dopamine(DA)and epinephrine(EP).Separation of the reduction peak potentials for dopamine and epinephrine was about 357 mV in pH 5.3 phosphate buffer solution(PBS)and the character was used for the detection DA and EP simultaneously.The peak currents increase linearly with DA and EP concentration over the range of 8.0×10-5 to 7.0×10-4 mol/L and 5.0×10-6 to 1.0×10-4 mol/L with detection limits of 2 × 10-5 and 1×10-6 mol/L,respectively.The interference studies showed that the modified electrode exhibits excellent selectivity in the presence of large excess of ascorbic acid(AA). 相似文献
2.
Waleed Ahmed El-Said Jin-Ho Lee Byung-Keun Oh Jeong-Woo Choi 《Electrochemistry communications》2010,12(12):1756-1759
In this study, we demonstrated a novel fabrication method of three dimensional nanoporous gold thin film (NPGF) onto gold (Au) substrate using electrochemical deposition method. Scanning electron microscope (SEM) investigation reveals the formation of highly-ordered pores, approximately 30 nm in diameter and 150 nm thick. The NPGF-modified electrode shows a linear range (0.1–40 μM) for dopamine detection in the presence of ascorbic acid. The electrochemical measurements of mixtures of dopamine, ascorbic acid, and uric acid in human serum sample for real sample applications was also investigated based on differential pulse voltammetry (DPV) technique. These high sensitivity and selectivity features of the proposed NPGF biosensor offer great promise for real sample biosensor application. 相似文献
3.
A novel taurine modified glassy carbon electrode was prepared by electropolymerization method. The electrochemical behaviors of epinephrine (EP) and dopamine (DA) at the modified electrode were studied by cyclic voltammetry. The modified electrode exhibited enhanced sensitivity and excellent electrochemical discrimination to DA and EP. The cathodic peaks of the two species were well-separated with a potential difference of about 390 mV, so the poly(taurine) modified electrode was used for simultaneous voltammetric measurement of EP and DA by differential pulse voltammetry. Under the optimum conditions, the cathodic peak currents were linear to concentrations of EP and DA in the range of 2.0 × 10−6 to 6.0 × 10−4 mol L−1 and 1.0 × 10−6 to 8.0 × 10−4 mol L−1, respectively. The detection limits for EP and DA were 3.0 × 10−7 and 1.0 × 10−7 mol L−1, respectively. Because the oxidation of ascorbic acid (AA) is an irreversible reaction at modified electrode, the interference of AA for determining EP and DA was eliminated. The modified electrode has been satisfactorily used for the simultaneous determination of EP and DA in pharmaceutical injections. 相似文献
4.
Exploiting micellar environment for simultaneous electrochemical determination of ascorbic acid and dopamine 总被引:1,自引:0,他引:1
A simple and reliable method for simultaneous electrochemical determination of ascorbic acid (AA) and dopamine (DA) is presented in this work. It was based on the use of the cationic surfactant cetylpyridinium chloride (CPC) that enables the separation of the oxidation peaks potential of AA and DA. Cyclic voltammetry (CV) as well as pulse differential voltammetry (PDV) were used in order to verify the voltammetric behaviour in micellar media. In the cationic surfactant CPC, a remarkable electrostatic interaction is established with negatively charged AA, as a consequence, the oxidation peak potential shifted toward less positive potential and the peak current increased. On the other hand, the positively charged DA is repelled from the electrode surface and the oxidation peak potential shifts toward more positive potential in comparison to the bare electrode. Therefore, the common overlapped oxidation peaks of AA and DA can be circumventing by using CPC. Parameter that affects the Epa and Ipa such as CPC concentration and pH were studied. Under optimised conditions, the method presented a linear response to AA and DA in the concentration range from 5 to 75 μmol L−1 and 10 to 100 μmol L−1, respectively. The proposed method was successfully applied to the simultaneous determination of AA and DA in dopamine hydrochloride injection (DHI) samples spiked with AA. 相似文献
5.
A poly(L-methionine) modified electrode, fabricated by electrochemical immobilization of the L-methionine on a glassy carbon
electrode, was used for simultaneous determination of dopamine and epinephrine through cyclic voltammetry. The electrochemical
properties of dopamine and epinephrine have been investigated. This sensor gave two separated cathodic peaks at −0.282 and
0.112 V for EP and DA, respectively. A linear response was obtained in the range of 5.0 × 10−7 to 1.0 × 10−4 mol l−1 for epinephrine, and 1.0 × 10−6 to 5.0 × 10−4 mol l−1 for dopamine. The detection limits were 3.6 × 10−7 mol l−1 and 4.2 × 10−7 mol l−1 for epinephrine and dopamine, respectively. This method was successfully applied for simultaneous determination of dopamine
and epinephrine in human urines.
The text was submitted by the authors in English. 相似文献
6.
7.
A silver hexacyanoferrate nanoparticles/carbon nanotubes modified glassy carbon electrode was fabricated and then successfully used for the simultaneous determination of ascorbic acid, dopamine and uric acid by cyclic voltammetry. A detailed investigation by transmission electron microscopy (TEM) and electrochemistry was performed in order to elucidate the preparation process and properties of the nanocomposites. The size of silver hexacyanoferrate nanoparticles was examined by TEM around 27 nm. Linear calibration plots were obtained over the range of 4.0 × 10−6-7.8 × 10−5, 2.4 × 10−6-1.3 × 10−4 and 2.0 × 10−6-1.5 × 10−4 mol L−1 with detection limits of 4.2 × 10−7,1.4 × 10−7 and 6.0 × 10−8 mol L−1 for ascorbic acid, dopamine and uric acid, respectively. The practical analytical utilities of the modified electrode were demonstrated by the determination of ascorbic acid, dopamine and uric acid in urine and human blood serum samples. 相似文献
8.
A novel Cu-zeolite A/graphene modified glassy carbon electrode for the simultaneous electrochemical determination of dopamine (DA) and ascorbic acid (AA) has been described. The Cu-zeolite A/graphene composites were prepared using Cu2+ functionalized zeolite A and graphene oxide as the precursor, and subsequently reduced by chemical agents. The composites were characterized by X-ray diffraction, Fourier transform infrared spectra and scanning electron microscopy. Based on the Cu-zeolite A/graphene-modified electrode, the potential difference between the oxidation peaks of DA and AA was over 200 mV, which was adequate for the simultaneous electrochemical determination of DA and AA. Also the proposed Cu-zeolite/graphene-modified electrode showed higher electrocatalytic performance than zeolite/graphene electrode or graphene-modified electrode. The electrocatalytic oxidation currents of DA and AA were linearly related to the corresponding concentration in the range of 1.0 × 10−7–1.9 × 10−5 M for DA and 2.0 × 10−5–2.0 × 10−4 M for AA. Detection limits (<!-- no-mfc -->S/N<!-- /no-mfc --> = 3) were estimated to be 4.1 × 10−8 M for DA and 1.1 × 10−5 M for AA, respectively. 相似文献
9.
A novel biosensor was fabricated by electrochemical deposition of gold nanoclusters on ultrathin overoxidized polypyrrole (PPyox) film, formed a nano-Au/PPyox composite on glassy carbon electrode (nano-Au/PPyox/GCE). The properties of the nanocomposite have been characterized by field emission scanning electron microscope (FE-SEM), X-ray photoelectron spectroscopy (XPS), powder X-ray diffraction (XRD) and electrochemical investigations. The nano-Au/PPyox/GCE had strongly catalytic activity toward the oxidation of epinephrine (EP), uric acid (UA) and ascorbic acid (AA), and resolved the overlapping voltammetric response of EP, UA and AA into three well-defined peaks with a large anodic peak difference. The catalytic peak currents obtained from differential pulse voltammetry increased linearly with increasing EP and UA concentrations in the range of 3.0 × 10−7 to 2.1 × 10−5 M and 5.0 × 10−8 to 2.8 × 10−5 M with a detection limit of 3.0 × 10−8 and 1.2 × 10−8 M (s/n = 3), respectively. The results showed that the modified electrode can selectively determine EP and UA in the coexistence of a large amount of AA. In addition, the sensor exhibited excellent sensitivity, selectivity and stability. The nano-Au/PPyox/GCE has been applied to determination of EP in epinephrine hydrochloride injection and UA in urine samples with satisfactory results. 相似文献
10.
The present work reports a quercetin-modified wax-impregnated graphite electrode (Qu/WGE) prepared through an electrochemical oxidation procedure in quercetin-containing phosphate buffer solution (PBS), for the purpose of detecting uric acid (UA) in the presence of ascorbic acid (AA). During modification quercetin was oxidized to the corresponding quinonic structure, and in the blank buffer solution the electrodeposited film exhibits a voltammetric response anticipated for the surface-immobilized quercetin. Retarding effect of the film towards the reaction of anionic species was found; therefore the pH of sample solutions was selected to ensure the analyte in molecular form. At suitable pHs the Qu/WGE shows excellent electrocatalytic effect towards the oxidation of both AA and UA, and separates the voltammetric signal of UA from AA by about 280 mV, allowing simultaneous detection of these two species. A linear relation between the peak current and concentration was obtained for UA in the range of 1-50 μM in the presence of 0.5 mM AA, with a detection limit 1.0 μM (S/N = 3). This sensor was stable, reproducible and outstanding for long-term use. 相似文献
11.
Carbon nanotube-modified electrodes for the simultaneous determination of dopamine and ascorbic acid 总被引:9,自引:0,他引:9
The voltammetric separation of dopamine and ascorbic acid was studied with cyclic voltammetry at two kinds of carbon nanotube-modified electrodes (coated and intercalated). The anodic peak difference reached 270 mV under the present conditions. The separation mechanism and effect factors were carefully studied. Using various types of surfactants as coating dispersants of carbon nanotubes, it was demonstrated that the charge nature of the surfactants had a strong effect on the electrochemical behavior of dopamine and ascorbic acid. When the oxidation solution of carbon nanotubes was changed from the most commonly used mixed concentrated nitric acid and sulfuric acid (1 + 3 v/v) to dilute nitric acid and to hydrochloric acid, the anodic peak separation value of dopamine and ascorbic acid increased significantly, and it was shown that carboxylic acid groups attached to the carbon nanotubes were an adverse factor for the discrimination of DA from AA. These results indicated that the resolution of DA and AA was mainly attributable to the stereo porous interfacial layer formed from aggregated pores and inner cavities of the carbon nanotubes. The modified electrodes exhibited an attractive ability to measure DA and AA simultaneously and showed good stability and reproducibility. 相似文献
12.
An over-oxidized poly(N-acetylaniline) (PNAANI)/GCE was used to determine dopamine (DA) in a large excess of ascorbic acid (AA) by differential pulse voltammetry. A linear relation between Ip and DA concentration was found over the range 5.0 x 10(-7) to 2.0 x 10(-5) M. The detection limit was 1.68 x 10(-8) M for S/N = 3 and 400 microM AA did not interfere with the DA determination. The high sensitivity was due to accumulation and selectivity was due to charge discrimination. The mechanism of selective determination of DA at over-oxidized PNAANI/GCE was also proposed. 相似文献
13.
M. Noroozifar M. Khorasani-Motlagh S. Rostami F. Zareian Jahromi 《Journal of the Iranian Chemical Society》2013,10(5):1025-1032
A novel modified glassy carbon electrode with ytterbium fluoride nanoparticles (YFNPs)-multiwalled carbon nanotubes (MWCNTs) was fabricated and then successfully used for the simultaneous determination of ascorbic acid (AA), dopamine (DA) and uric acid (UA). YFNPs were successfully coated on the MWCNTs via the intermediate of noncovalent hydrophobic interactions of the MWCNTs surface with sodium dodecyl sulfate. The YFNPs and immobilization of YFNPs on MWCNTs were confirmed by transmission electron microscopy. The particle size of YFNPs was measured to be around 45 nm. The catalytic peak currents for AA, DA and UA were linearly dependent on their concentrations in the range of 2.0–600.0, 2.0–560.0 and 1.8–640.0 μM, respectively, with the corresponding detection limits of 0.77, 0.22 and 0.17 μM. The modified electrode provided good sensitivity and stability, and was successfully applied for the simultaneous determination of AA, DA and UA in human blood serum and urine samples. 相似文献
14.
Graphene/p-aminobenzoic acid composite film modified glassy carbon electrode (Gr/p-ABA/GCE) was first employed for the sensitive determination of dopamine (DA). The electrochemical behavior of DA at the modified electrode was investigated by cyclic voltametry (CV), differential pulse voltametry (DPV) and amperometric curve. The oxidation peak currents of DA increased dramatically at Gr/p-ABA/GCE. The modified electrode was used to electrochemically detect dopamine (DA) in the presence of ascorbic acid (AA). The Gr/p-ABA composite film showed excellent electrocatalytic activity for the oxidation of DA in phosphate buffer solution (pH 6.5). The peak separation between DA and AA was large up to 220 mV. Using DPV technique, the calibration curve for DA determination was obtained in the range of 0.05-10 μM. The detection limit for DA was 20 nM. AA did not interfere with the determination of DA because of the very distinct attractive interaction between DA cations and the negatively Gr/p-ABA composite film. The proposed method exhibited good stability and reproducibility. 相似文献
15.
The present study reports the simultaneous determination of ascorbic acid (AA), dopamine (DA) and uric acid (UA) in 0.20 M phosphate buffer solution (pH 5.0) using electropolymerized ultrathin film of 5-amino-2-mercapto-1,3,4-thiadiazole (AMT) on glassy carbon (GC) electrode. The bare GC electrode does not separate the voltammetric signals of AA, DA and UA. However, electropolymerized AMT (p-AMT) modified GC electrode not only resolved the voltammetric signals of AA, DA and UA but also dramatically enhanced their oxidation peak currents when compared to bare GC electrode. The enhanced oxidation currents for AA, DA and UA at p-AMT modified electrode are due to the electrostatic interactions between them and the polymer film. Using amperometric method, we achieved the lowest detection of 75 nM AA, 40 nM DA and 60 nM UA at p-AMT modified electrode. The amperometric current was linearly increased from 200 nM to 0.80 mM for each AA, DA and UA and the lowest detection limit was found to be 0.92, 0.07 and 0.57 nM, respectively (S/N = 3). The practical application of the modified electrode was demonstrated by the determination of DA in dopamine hydrochloride injection. 相似文献
16.
采用循环伏安法(CV)制备了聚钙羧酸(PCCA)膜修饰的碳糊电极(CPE)。考察了电极对多巴胺(DA)、尿酸(UA)的电氧化催化性能。结果显示,聚钙羧酸膜修饰碳糊电极(PCCA/CPE)对DA有良好的电催化效果,DA呈现出一对准可逆的氧化还原峰,氧化峰电流与DA浓度在3.0×10-7~1.0×10-4mol/L范围内呈线性关系,检出限为1×10-7mol/L(S/N=3)。使用微分脉冲伏安法(DPV),DA和UA在PCCA/CPE上的氧化峰能完全分离(ΔEp=192 mV),且峰电流与浓度均呈现良好的线性关系,可实现对DA和UA的同时测定。实验还进行了实际样品测定。 相似文献
17.
Nanostructured platinum-gold (Pt–Au) hybrid film modified glassy carbon electrode (GCE) was fabricated by electro-deposition
method in the presence of 2 × 10−4 mol l−1
l-cysteine. To examine the surface morphological analysis, the (Pt–Au) hybrid film were electrochemically deposited on transparent
semiconductor indium tin oxide (ITO) electrodes for scanning electron microscopy (SEM) and energy dispersive spectroscopy
(EDS) studies. From the SEM analysis, it was observed that the deposited nanoplatinum (250–400 nm) was formed as a cauliflower-shaped
structure with the gold nanoparticles (30–90 nm). The concentration variation of additive l-cysteine results in the formation of cauliflower-shaped platinum nanoparticles. Further, the Pt–Au hybrid film modified GCE
could be used for the detection of catecholamine neurotransmitters epinephrine (EP), norepinephrine (NEP) individually and
in the presence of ascorbic acid (AA) in pH 7 phosphate-buffered solutions (PBS). Furthermore, the proposed Pt–Au hybrid film
could be applied for the detection of epinephrine in injection solution and ascorbic acid from commercially available vitamin
C tablets. 相似文献
18.
Yeong-Tarng Shieh Yi-An Chen Rong-Hsien Lin Tzong-Liu Wang Chien-Hsin Yang 《Colloid and polymer science》2012,290(14):1451-1456
Poly(N-isopropylacrylamide)(PNIPAAm) with a lower critical solution temperature of about 32?°C was used as matrix to prepare temperature responsive carbon nanotubes (CNT) and functionalized CNT (fCNT) composites to modify glassy carbon electrode (GCE) as working electrode for electrochemical selective detection of dopamine, uric acid, and ascorbic acid. The GCE modification temperature (25 and 37?°C, denoted as 25f and 37f), working temperature (25 and 37?°C, denoted as 25aq and 37aq), and the type of CNT (CNT and fCNT) were found to significantly affect the electrocatalytic activity of the composites toward redox reactions of Fe(CN) 6 3?/4? as a probe and the selective detection ability for the three analytes. The fCNT/PNIPAAm composite with the 25f–37aq temperature combination exhibited strong electrocatalytic activity and highly selective detection ability for the three analytes. In contrast, the same composite with the other three combinations (25f–25aq, 37f–25aq, and 37f–37aq) and the CNT/PNIPAAm composite with all four combinations exhibited insignificant electrocatalytic activity and no selective detection ability. 相似文献
19.
A glassy carbon electrode modified with poly(alizarin red)/electrodeposited graphene (PAR/EGR) composite film was prepared and applied to detect ciprofloxacin (CPFX) in the presence of ascorbic, uric acid and dopamine. The morphology and interface property of PAR/EGR films were examined by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The electrocatalytic oxidation of CPFX on AR/EGR was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The linearity ranged from 4 × 10−8 to 1.2 × 10−4 M with a detection limit (S/N = 3) of 0.01 μM. The modified electrode could be applied to the individual determination of CPFX as well as the simultaneous determination of CPFX, ascorbic acid, uric acid and dopamine. This method proved to be a simple, selective and rapid way to determine CPFX in pharmaceutical preparation and biological media. 相似文献
20.
Flow injection amperometric quantification of ascorbic acid (AA), dopamine (DA), epinephrine (EP) and dipyrone (DI) in mixtures (in the microgram g-1 range) was successfully performed by using an array of microelectrodes with units modified by the electrodeposition of different noble metals, together with multivariate calibration analysis. The four groups of microelectrodes utilized included a pure gold electrode and electrodes modified by electrodeposition of platinum, palladium or a mixture of platinum + palladium. The array of microelectrodes was inserted in a flow cell and the amperometric data acquisition was performed with a four-channel potentiostat. The analysis of the resulting signals was carried out by a multivariate calibration method, using a group of 16 standard mixtures selected by a two-level factorial design. The analysis of synthetic samples and pharmaceutical compounds containing AA and DI led to very similar values to those obtained by the classical iodimetric analysis. The average absolute errors (in microgram g-1) calculated for each analyte were 0.3, 0.2, 0.4 and 0.4 for AA, DA, EP and DI, respectively. 相似文献