首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
Lin CC  Liu CY 《Electrophoresis》2004,25(18-19):3216-3223
With 3-trimethoxysilylpropyl chloride as the spacer, a proline-coated capillary column was prepared for the capillary electrochromatographic (CEC) separation of amino acids by in-column derivatization. Nine standard mixtures, including aspartic acid, glutamic acid, valine, phenylalanine, alanine, isoleucine, leucine, tyrosine, and tryptophan, were injected. o-Phthalaldehyde (OPA), OPA/2-mercaptoethanol (2-ME) and OPA/N-acetylcysteine (NAC) in borate buffer were tested as the derivatizing agent. Among them, OPA (50 mM) in borate buffer (pH 9.5, 50 mM) gave the best performance. The formation of isoindole could be detected by UV detection. The sandwich-type injection was carried out in hydrostatic mode (10 cm) with the program R(10 s)S(10 s) R(10 s)W(10 min) with R, S, and W being the reagent, sample, and waiting times. Mesityl oxide, benzyl alcohol, and acetone showed some interaction with the column. A current monitoring method was used instead of the determination of the electroosmotic flow (EOF). The direction of EOF was from anode to cathode even under acidic condition lower than the pI value (6.31) of the bonded group due to some unreacted silanol groups. Some parameters including pH, nature, and concentration of the mobile phase and the effect of organic modifier with regard to the CEC separation were investigated. With the proline-coated column (75 (50) cm x 75 microm ID) the best separation was performed in phosphate buffer (pH 4.00, 100 mM) with an applied voltage of -15 kV. The established method was also compared with those precolumn derivatized prior to the separation with proline-coated column as well as with in-capillary derivatization and separation with a bare fused-silica column.  相似文献   

2.
A macroporous, spherical, 7 μm, polystyrene–divinylbenzene (PS–DVB), reversed-phase adsorbent (PRP-1) was evaluated as a stationary phase for the capillary electrochromatographic (CEC) separation of neutral, acidic, and basic analytes of pharmaceutical interest. Electroosmotic flow (EOF) for a PRP-1 packed capillary is nearly constant over the pH 2 to 10 range and is higher than for a silica-based C18 packed capillary on the acidic side. EOF increases with an increase in buffer acetonitrile concentration or as applied potential increases. As analyte hydrophobicity increases, analyte retention and migration time increases. Increasing buffer acetonitrile concentration reduces analyte partitioning with the PS–DVB stationary phase and analyte retention and migration time decreases. When exchange sites are present on the PS–DVB copolymer, EOF (EOF is reversed for the anion-exchanger) increases as the exchange capacity increases. An increased exchange capacity also reduces partitioning of the analyte with the PS–DVB matrix and analyte retention and migration time decrease. Because of excellent stability in an acid environment, the PRP-1 packed capillary can be used in strong acid buffer solution and weak acid and base analytes depending on pKa values can be separated as neutral species and cations, respectively. CEC separations on a PRP-1 capillary of neutral steroids, weak base pharmaceuticals (separation as cations), purines and pyrimidines (as cations), fatty acids (as undissociated species), and sulfa derivatives (as cations) are described. Efficiency for the PRP-1 packed capillary for acetone or thiourea as the analyte is about 6·104 plates m−1.  相似文献   

3.
In the complex neuronal network, chemical messengers like neuropeptides play a key role in signaling. To understand the mechanism of signaling, it is necessary to analyze the levels of neuropeptides from biological sources, which is important for neuroscience research. In the present work, a detailed investigation of the capillary zone electrophoresis (CZE) method was carried out to detect and quantify Substance P (SP), a bioactive neuropeptide, in rat brain tissues. The method involves specifically, a combination of solid phase extraction and immunoprecipitation prior to the CZE quantification. In this procedure, antibodies are used to capture the analyte of interest before the separation by CZE. Different separation parameters like buffer type, concentration, pH and applied voltage were the steps taken to study and achieve high efficiency CZE separation. CZE analysis was performed in an untreated fused-silica capillary column (35 cm×75 μm i.d.) and 185 nm wavelength using 100 mM phosphate buffer (pH 2.5) as a separation buffer. Electrophoresis in acidic mode and successive washing procedures solved the adsorption problem. The method provides a rapid analysis time of less than 15 min with 3.91% of RSD. Simultaneously, SP was quantified by Matrix Assisted Laser Desorption Ionization-Time of Flight-Mass Spectrometry (MALDI-TOF-MS) and compared with CZE data. Starting from milligram amounts of brain tissue, the method allowed the detection of low picomole amounts of SP and the combined use of CZE and MALDI-TOF-MS was a success in quantification in this study.  相似文献   

4.
卤代乙酸及其结构相近化合物的高效毛细管电泳分离   总被引:2,自引:0,他引:2  
关福玉  吴惠芳  罗毅 《色谱》1996,14(2):134-136
氟、氯、溴等卤代乙酸是结构非常相近的离子型化合物,对它们的分离测定比较困难。用高效毛细管电泳法在碱性或酸性缓冲液条件下可将它们分离。在酸性缓冲液条件下,可提高有机酸分离的选择性。较低的操作电压有利于提高阴离子的分离度,而改变温度对分离度的影响不大。  相似文献   

5.
La S  Kim A  Kim JH  Choi OK  Kim KR 《Electrophoresis》2002,23(7-8):1080-1089
An efficient capillary electrophoretic (CE) profiling and screening system based on dual modes of capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) was developed for the simultaneous determination of 23 nonprotein amino acids (NPAAs) and 4 protein amino acids with aromatic moiety. It involves separation by an uncoated fused-silica capillary under phosphoric acid buffer in CZE mode and by another uncoated fused-silica capillary under neutral sodium dihydrogen phosphate buffer containing sodium dodecyl sulfate in MEKC mode. Migration orders of the amino acids studied on the two separation modes under each optimum condition were very different. The repeatability of migration times measured by the CZE and MEKC was found to be better than 4.8 and 3.4%, respectively, thereby enabling to cross-check the identification of each amino acid. The method linearity and limit of detection of the CZE for each amino acid were found to be adequate for the assay of aromatic amino acids. When the present CE profiling and screening analysis in dual modes was applied to plant seeds, NPAAs such as mimosine from Mimosa pudica Linné, and 2-phenylglycine from Lindera erythrocarpa Makino were positively detected along with tryptophan, phenylalanine and tyrosine.  相似文献   

6.
A fast, convenient and sensitive method of capillary zone electrophoresis (CZE) and indirect UV detection was proposed for the determination of 16 amino acids. p-Aminobenzoic acid (PAB) was selected as a background electrolyte (BGE). An isolated cell included a BGE buffer part and an electrode buffer one, which were jointed with a glass frit. The isolated cell can prevent PAB from the electrode reaction and improve the stability of the detection baseline. The separation conditions of amino acids were investigated, such as different BGEs, BGE concentration, buffer pH and electroosmotic flow (EOF) modifiers. Under the selected separation conditions, 14 amino acid peaks could be separated in 12 min. The detection limits of the amino acids were in the range of 1.7 - 4.5 micromol/L. The isolated cell is suitable for reagents reacting on the electrodes in capillary electrophoresis. The proposed method has been successfully applied to the determination of the amino acids in tobacco samples.  相似文献   

7.
Numerous efforts have been made to separate proteins by capillary zone electrophoresis (CZE). The most common optimization techniques are changing the pH of the running buffer, coating the capillary surface with a hydrophilic polymer, or using additives in the sample solution. Surface coatings and solution additives can reduce the adsorption of the protein onto the capillary surface, but they diminish the separation efficiency and the resolution of CZE. This paper reports the successful separation of proteins in a untreated fused-silica capillary by raising the pH of the running buffer and washing between runs with 1.0 M sodium hydroxide. Under these conditions, model proteins and proteins in human serum have been determined by CZE. It is shown that the results from CZE are compatible with those of sodium dodecyl sulphate-polyacrylamide gel electrophoresis.  相似文献   

8.
The aim of this study was to setup a method for detection and quantification of monosaccharide components in technical galactoglucomannas (T-GGM) from spruce wood using capillary zone electrophoresis (CZE). CZE technique was optimised regarding borate buffer concentrations, EOF modifier application, and system pH. Aqueous solution of T-GGM was chemically hydrolysed by sulphuric acid, in an autoclave. In this way obtained monosaccharides were derivatized with 4-amino benzoic acid ethyl ester via reductive amination using sodium cyanoborohydride. The results of the optimisation procedure showed that the borate buffers at lowest concentrations (100 and 200 mM) with acetonitrile addition as EOF modifier gave the optimal measurement results, as it showed sufficient separation at relatively short migration times. The amounts of single monosaccharide components in the T-GGM samples obtained by the optimised CZE procedure were practically the same in comparison to the results of the well established HPLC-anion exchange chromatography. On the basis of this research, it was concluded that the capillary zone electrophoresis is an efficient analytical procedure for the characterisation of galactoglucomannans derived from softwoods.  相似文献   

9.
In the present paper, two new methods, sol-gel and chemical bonding methods, were proposed for preparation of sulfonated fused-silica capillaries. In the sol-gel method, a fused-silica capillary was coated with the sol solution obtained by hydrolysis of 3-mercaptopropyltrimethoxysilane (MPTS) and tetramethoxysilane, and followed by age; while in the chemical bonding method, a capillary was chemically bonded directly with MPTS. Then, both the resulting capillaries were oxidized with an aqueous solution of hydrogen peroxide solution (H2O2) (30%, m/m) to obtain the sulfonated capillaries. The electroosmotic flow (EOF) for the sulfonated capillaries was found to remain almost constant within the studied pH range, and greater than that of the uncoated capillary. However, the coating efficiency of the capillary prepared by chemical bonding method was higher than that by sol-gel method, by comparing their magnitude of the EOF, the degree of disguise of the silanol and reproducibility of preparation procedure. The effects of the electrolyte's concentration and the content of methanol (MeOH) on the EOF were also studied. Especially, the study of the apparent pH (pH*) on the EOF in a water-MeOH system was reported. Finally, capillary electrophoretic separation of seven organic acids was achieved within 6.5 min under optimal condition using the chemically bonded sulfonated capillary. Moreover, separation of four alkaloids on the sulfonated capillary was compared with that on uncoated capillary in different conditions. Ion-exchange mechanism was found to play a key role for separation of these four basic analytes on the sulfonated capillary.  相似文献   

10.
Cao F  Luo Z  Zhou D  Zeng R  Wang Y 《Electrophoresis》2011,32(10):1148-1155
In this work, a novel graft copolymer, hydroxyethylcellulose-graft-poly(2-(dimethylamino)ethyl methacrylate) (HEC-g-PDMAEMA), used as physical coatings of the bare fused-silica capillaries, was synthesized by using ceric ammonium nitrate initiator in aqueous nitric acid solution. EOF measurement results showed that the synthesized HEC-g-PDMAEMA graft copolymer-coated capillary in this paper could suppress EOF effectively compared to the bare fused-silica capillary, and efficient separations of basic proteins were also achieved. The electrical charge of the coated capillary wall could be modulated by varying not only the pH of the running buffer, but also the grafting ratio of poly(2-(dimethylamino)ethyl methacrylate) grafts, which makes possible the analysis of basic and acidic proteins in the same capillary. The effects of poly(2-(dimethylamino)ethyl methacrylate) grafting ratio in HEC-g-PDMAEMA and buffer pH on the separation of basic proteins for capillary electrophoresis were investigated in detail. Furthermore, egg white proteins and milk powder samples were separated by the HEC-g-PDMAEMA-coated capillary. The results demonstrated that the HEC-g-PDMAEMA copolymer coatings have great potential in the field of diagnosis and proteomics.  相似文献   

11.
Optimum conditions for the separation of positional isomers of chlorophenols by capillary zone electrophoresis (CZE) were established. The behavior of five volatile electrolytes (L-cysteic acid, 3-amino-1-propanesulfonic acid, aminomethanesulfonic acid, diethylmalonic acid, and ammonium acetate) was compared. The best performance based on low electrophoretic current and high separation efficiency was obtained for diethylmalonic acid as working electrolyte. The influence of pH on the separation, using both uncoated fused-silica capillaries and modified capillaries (NaAMPS from EKT) with anionic coating, was discussed. Moreover, the effect of electrolyte concentration and applied voltage using fused-silica capillaries was studied. The optimum CZE conditions that allowed the separation of 16 chlorophenols were 20 kV, 30 mM diethylmaIonic acid, pH 7.25, and uncoated fused-silica capillary. Figures of merit such as run-to-run and day-to-day precision, linearity, and limits of detection were calculated.  相似文献   

12.
A new application of the polymeric ionic liquid (PIL) in capillary electrophoresis is reported. Poly(1-vinyl-3-butylimidazolium bromide) was physically adsorbed on silica capillary as the simple and effective coating for capillary electrophoresis (CE) analysis, in which the PIL is not present in the background electrolyte. The electroosmotic flow (EOF) of the PIL-coated capillary as compared with that of the bare fused-silica capillary shows a different dependence on electrolyte pH values. The EOF is reversed over a wide pH range from 3.0 to 9.0 and shows good repeatability. It is also found that the coated capillary has a good tolerance to some organic solvents, 0.1 M NaOH and 0.1 M HCl. The PIL-coated capillary has been employed in different areas. Both the basic proteins and anionic analytes can be well separated by PIL-coated capillaries in a fast and easy way. The PIL-coated capillary is also able to separate organic acid additives in a grape juice. The results showed that this type of coating provides an alternative to the CE separation of anions and basic proteins.  相似文献   

13.
Yanqing Wang  Changgang Huang  Li He 《Talanta》2009,77(5):1667-1674
This paper describes the enhanced separation of lomefloxacin, sparfloxacin, fleroxacin, norfloxacin, ofloxacin, gatifloxacin and pazufloxacin by capillary zone electrophoresis (CZE) using silica nanoparticles (SiNPs) as running buffer additive. The impact of SiNPs concentration on the resolution and selectivity of separation was investigated and a given value of SiNPs was finally chosen under the optimum conditions. The addition of the SiNPs to the running buffer enabled electroosmotic flow (EOF) decrease and permitted full interaction between SiNPs and analytes. The influence of separation voltage, pH and buffer concentration on the separation in the presence of SiNPs was examined. Interactions between drugs and nanoparticles during the separation are discussed; the determination of interaction constants is also achieved. A good resolution of seven quinolones was obtained within 15 min in a 50 cm effective length fused-silica capillary at a separation voltage of +10 kV in a 12 mM disodium tetraborate-phosphate buffer (pH 9.08) containing 5.2 μg mL−1 SiNPs.  相似文献   

14.
Two modes of capillary electrophoresis (CE)--free-solution capillary zone electrophoresis (CZE) and sodium dodecyl sulfate capillary electrophoresis (SDS-CE) using a non-gel sieving matrix--have been developed for comparative analysis of low-molecular-mass 2S albumin isoforms from lupins. The albumin fraction and 2S albumins were separated in uncoated fused-silica capillary by CZE with 0.02 M phosphate buffer, pH 7.3, containing the sodium salt of phytic acid. The use of phytic acid (0.025 M) as buffer modifier and ion-pairing agent improved migration reproducibility, peak shape and separation efficiency. The reduced 2S albumins were separated by SDS-CE using a high concentration (0.3-0.5 M) mixture of tris(hydroxymethyl)aminomethane and borate buffers in uncoated fused-silica capillary. Of the various polymers used as non-gel sieving matrix, SDS-CE with a 10% dextran solution was found to be suitable for separation of 2S albumin polypeptides with molecular masses of 4,000-7,000 and 8,000-11,000. The addition of glycerol or ethylene glycol to the SDS separating buffer improved the resolution of polypeptides. The examined Lupinus species showed species-specific CZE and SDS-CE migration profiles of the 2S albumins.  相似文献   

15.
Dong X  Dong J  Ou J  Zhu Y  Zou H 《Electrophoresis》2006,27(12):2518-2525
A polymer-based neutral monolithic capillary column was prepared by radical polymerization of glycidyl methacrylate and ethylene dimethacrylate in a 100 mum id fused-silica capillary, and the prepared monolithic column was subsequently modified based on a ring opening reaction of epoxide groups with 1 M lysine in solution (pH 8.0) at 75 degrees C for 10 h to produce a lysine chemically bonded stationary phases in capillary column. The ring opening reaction conditions were optimized so that the column could generate substantial EOF. Due to the zwitterionic functional groups of the lysine covalently bonded on the polymer monolithic rod, the prepared column can generate cathodic and anodic EOF by varying the pH values of running buffer during CEC separation. EOF reached the maximum of -2.0 x 10(-8) m2v(-1)s(-1) and 2.6 x 10(-8) m2v(-1)s(-1) with pH of the running buffer of 2.25 and 10, respectively. As a consequence, neutral compounds, ionic solutes such as phenols, aromatic acids, anilines, and basic pharmaceuticals were all successfully separated on the column by CEC. Hydrophobic interaction is responsible for separation of neutral analytes. In addition, the electrostatic and hydrophobic interaction and the electrophoretic migration play a significant role in separation of the ionic or ionizable analytes.  相似文献   

16.
Capillary zone electrophoretic (CZE) separation of basic proteins has been achieved with capillary columns modified with copolymers of vinylpyrrolidone (VP) and vinylimidazole (VI). The copolymerization reaction is performed inside the capillary column and involves chemical bonding of the polymer to silica. The electroosmotic flow (EOF) is greatly decreased by this surface modification. The presence of positive charges on the coating surface, due to the cationic property of vinylimidazole at pH below 7, reduces the adsorption of basic proteins onto the silanol groups of the capillary surface. Acidic proteins are irreversibly adsorbed, but rapid separation and good performance reproducibility are obtained with basic proteins. In the case of capillaries modified with VP, the acidic and basic proteins are eluted within 10 min. In this work, we studied the effects of pH and buffer concentration on the magnitude of the EOF, as well as the effect of copolymer composition on the separation efficiency.  相似文献   

17.
Mori M  Tsue H  Tanaka S  Tanaka K  Haddad P 《Electrophoresis》2003,24(12-13):1944-1950
A new coated capillary has been introduced for capillary electrophoretic separation of anions by using a positively charged diazacrown ether with a 12-membered ring. A positive charge spread over the inner capillary surface led to a substantial anodic electroosmotic flow (EOF) over the range of migrating buffer of pH 2-11. Under the optimum conditions of 25 mM phosphate buffer at pH 7, the diazacrown-coated capillary showed a successful simultaneous separation of 7 inorganic anions and 13 aromatic anions (including positional isomers) in less than 15 min. The migration times of the sample anions and EOF marker for consecutive runs on a single column were highly reproducible, giving a relative standard deviation of 1%. Theoretical treatment of the migration behavior clearly demonstrated that ion association between the diazacrown and analyte anions is strongly dependent on the nature of the functional groups of anions (e.g., sulfonate groups > carboxyl groups) and the number of negative charges (e.g., trivalent anions > divalent anions > monovalent anions) on the analyte.  相似文献   

18.
A physically adsorbed and covalently bonded porphyrin derivative, 5,10,15,20-tetrakis(pentafluorophenyl)porphyrin, H2TPFPP, has been used as a fused-silica capillary wall modifier in open tubular capillary electrochromatography (OT-CEC), and its influence on the electroosmotic flow (EOF) velocity and on the selectivity of OT-CEC separations of a set of model aromatic carboxylic acids has been tested. Whereas most of the coatings of this category bring about an increase in selectivity with a concomitant slow down of the EOF, H2TPFPP coating, depending on pH of the background electrolyte used, resulted both in decreasing of EOF at pH 8.5 by 5% and in increasing of EOF by 10–43% at pH 6 and 5, respectively. The separation efficiency and the resolution of aromatic carboxylic acids separation in coated capillaries, namely in that one with covalent coating, were better than in the bare fused-silica capillary. The perspectives of H2TPFPP as capillary wall modifier are visualized in introducing well defined electroosmotic properties of materials used for miniaturized separation channels preparation in chip-based electromigration devices.  相似文献   

19.
Methacrylate-based monolithic columns with electroosmotic flow (EOF) or very weak EOF are prepared by in situ copolymerization in the presence of a porogen in fused-silica capillaries pretreated with a bifunctional reagent. Satisfactory separations of acidic and basic compounds on the column with EOF at either low or high pH are achieved, respectively. With sulfonic groups as dissociation functionalities, sufficient EOF mobility still remains as high as 1.74 x 10(-4) cm2 s(-1) V(-1) at low pH. Under this condition, seven acidic compounds are readily separated within 5.7 min. Moreover, at high pH, the peak shape of basic compounds is satisfactory without addition of any masking amines into running mobile phase since the secondary interaction between the basic compounds and the monolithic stationary phase are minimized at high pH. Reversed-phase mechanism for both acidic and basic compounds is observed under investigated separation conditions. In addition, possibilities of acidic and basic compound separations on a monolithic column with extremely low EOF are discussed.  相似文献   

20.
The combination of capillary isotachophoresis (ITP) and capillary zone electrophoresis (CZE) in the column coupling configuration was optimized in a mode where the electrolyte for the CZE step is different from the leading and terminating ITP electrolytes. Two colored markers, picric acid and 1-nitroso-2-naphthol, were used for exact timing of the transfer of isotachophoretically stacked analyte zones into the CZE column and for the control of the residual amount of the leading and terminating ITP electrolytes entering the CZE capillary together with the analytes, thus controlling the duration of transient ITP migration in the CZE capillary and ensuring good separation of the analytes and reproducibility of the migration times (relative standard deviations 1%). ITP-CZE was applied to the simultaneous assay of several cinnamic acid derivatives and flavonoids in methanolic extracts of Sambucus flowers and Crataegus leaves and flowers. The preconcentrating and cleansing effect of the ITP step allowed injection of relatively large sample volumes (30 microL). The limits of detection were approximately 20-50 ng x mL(-1) and 100 ng x mL(-1) for the acids and flavonoids, respectively ( thick similar 200-times lower compared to conventional CE) with spectrophotometric detection at 254 nm. The ITP-CZE exhibited satisfactory linearity and precision when using CZE buffer of pseudo "pH" 9.0; 1-nitroso-2-naphthol was employed as the internal standard. The separation took approximately 35 min. The ITP-CZE results for rutin, hyperoside, and vitexin-2-O"-rhamnoside were in good accordance with those obtained previously by high-performance liquid chromatography.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号