首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Chitosan (CS) was chosen for dispersing multi‐wall carbon nanotubes (MWNTs) to form a stable CS‐MWNTs composite, which was first coated on the surface of a glassy carbon electrode to provide a containing amino groups interface for assembling colloidal gold nanoparticles (GNPs), followed by the adsorption of hemoglobin (Hb). Repeating the assembly step of GNPs and Hb resulted in {Hb/GNPs}n multilayers. The assembly of GNPs onto CS‐MWNTs composites was confirmed by transmission electron microscopy. The consecutive growth of {Hb/GNPs}n multilayers was confirmed by cyclic voltammetry and UV‐vis absorption spectroscopy. The resulting system brings a new platform for electrochemical devices by using the synergistic action of the electrocatalytic activity of GNPs and MWNTs. The resulting biosensor displays an excellent electrocatalytic activity and rapid response for hydrogen peroxide. The linear range for the determination of H2O2 was from 5.0×10?7 to 2.0×10?3 M with a detection limit of 2.1×10?7 M at 3σ and a Michaelis–Menten constant KMapp value of 0.19 mM.  相似文献   

2.
A novel composite material of copper (I) oxide at manganese (IV) oxide (Cu2O@MnO2), was synthesized and applied for modification on the glassy carbon electrode (GCE) surface (Cu2O@MnO2/GCE) as a hydrogen peroxide (H2O2) sensor. The composite material was characterized regarding its structural and morphological properties, using field emission scanning electron microscopy (FE‐SEM), energy‐dispersive X‐ray spectroscopy (EDX), X‐ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR). The Cu2O@MnO2/GCE showed an excellent electrocatalytic response to the oxidation of H2O2 which provided a 0.56 s?1 charge transfer rate constant (Ks), 1.65×10?5 cm2 s?1 diffusion coefficient value (D), 0.12 mm2 electroactive surface area (Ae) and 1.04×10?8 mol cm?2 surface concentration ( ). At the optimal condition, the constructed sensor exhibited a wide linear range from 0.5 μM to 20 mM with a low limit of detection (63 nM, (S/N=3) and a good sensitivity of 256.33 μA mM?1 cm?2. It also presented high stability (ΔIresponse±15 %, n=100), repeatability (1.25 %RSD, n=10) and reproducibility (3.55 %RSD, n=10). The results indicated that the synthesized Cu2O@MnO2 was successfully used as a new platform for H2O2 sensing.  相似文献   

3.
A poly(2‐aminophenylbenzimidazole)/gold nanoparticles (P2AB/AuNPs) coated disposable pencil graphite electrode (PGE) was fabricated as an enzyme‐free sensor for the H2O2 determination. P2AB/AuNPs and P2AB were successfully synthesized electrochemically on PGE in acetonitrile for the first time. The coatings were characterized by scanning electron microscopy, X‐ray diffraction spectroscopy, Energy‐dispersive X‐ray spectroscopy, Surface‐enhanced Raman spectroscopy, and UV‐Vis spectroscopy. AuNPs interacted with P2AB as carrier enhances the electrocatalytic activity towards reduction of H2O2. The analytical performance was evaluated in a 100 mM phosphate buffer solution at pH 6.5 by amperometry. The steady state current vs. H2O2 concentration is linear in the range of 0.06 to 100 mM (R2=0.992) with a limit of detection 3.67×10?5 M at ?0.8 V vs. SCE and no interference is caused by ascorbic acid, dopamine, uric acid, and glucose. The examination for the sensitive determination of H2O2 was conducted in commercially available hair oxidant solution. The results demonstrate that P2AB/AuNPs/PGE has potential applications as a sensing material for quantitative determination of H2O2.  相似文献   

4.
A novel non‐enzymatic sensor based on Ag/MnOOH nanocomposites was developed for the detection of hydrogen peroxide (H2O2). The H2O2 sensor was fabricated by immobilizing Ag/MnOOH nanocomposites on a glassy carbon electrode (GCE). The morphology and composition of the sensor surface were characterized using scanning electron microscopy, energy‐dispersive X‐ray spectroscopy, transmission electron microscopy and X‐ray diffraction spectroscopy. The electrochemical investigation of the sensor indicates that it possesses an excellent electrocatalytic property for H2O2, and could detect H2O2 in a linear range from 5.0 µM to 12.8 mM with a detection limit of 1.5 µM at a signal‐to‐noise ratio of 3, a response time of 2 s and a sensitivity of 32.57 µA mM?1 cm?2. Additionally, the sensor exhibits good anti‐interference. The good analytical performance, low cost and straightforward preparation method made this novel electrode material promising for the development of effective non‐enzymatic H2O2 sensor.  相似文献   

5.
The nanocomposites of Ag nanoparticles supported on Cu2O were prepared and used for fabricating a novel nonenzymatic H2O2 sensor. The morphology and composition of the nanocomposites were characterized using the scanning electron microscope (SEM), transmission electron microscope (TEM), energy‐dispersive X‐ray spectrum (EDX) and X‐ray diffraction spectrum (XRD). The electrochemical investigations indicate that the sensor possesses an excellent performance toward H2O2. The linear range is estimated to be from 2.0 μM to 13.0 mM with a sensitivity of 88.9 μA mM?1 cm?2, a response time of 3 s and a low detection limit of 0.7 μM at a signal‐to‐noise ratio of 3. Additionally, the sensor exhibits good anti‐interference.  相似文献   

6.
In this article, we present a simple and efficient method to synthesize a magnetic NiFe2O4 nanocatalyst under hydrothermal conditions. Fourier transform infrared spectroscopy (FT‐IR), X‐ray diffraction (XRD), scanning electron microscopy (SEM), and energy dispersive X‐ray spectroscopy (EDX) analyses confirmed the synthesis of NiFe2O4 nanoparticles. These nanoparticles showed satisfactory catalytic activity for determination of norepinephrine (NE) in the presence of folic acid (FA) using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. Differential pulse voltammetry peak currents of NE increased linearly with their concentrations in the range of 1.0 × 10?7–5.0 × 10?4 M, and the detection limit for NE was 2.3 × 10?8 M, respectively. The modified electrode displayed strong function for resolving the overlapping voltammetric responses of NE and FA into two well‐defined voltammetric peaks. In the mixture containing NE and FA, the two compounds can well separate from each other with a potential difference of 510 mV between NE and FA, which was large enough to determine NE and FA individually and simultaneously. Additionally, the prepared electrochemical sensor demonstrated a practical feasibility for real sample determination.  相似文献   

7.
A novel hydrogen peroxide (H2O2) sensor was fabricated by using a submonolayer of 3‐mercaptopropionic acid (3‐MPA) adsorbed on a polycrystalline gold electrode further reacted with poly(amidoamine) (PAMAM) dendrimer (generation 4.0) to obtain a film on which Prussian Blue (PB) was later coordinated to afford a mixed and stable electrocatalytic layer for H2O2 reduction. On the basis of the electrochemical behaviors, atomic force microscopy (AFM) and X‐ray photoelectron spectra (XPS), it is suggested that the PB molecules are located within the dendritic structure of the surface attached PAMAM dendrimers. It was found that the PB/PAMAM/3‐MPA/Au modified electrode showed an excellent electrocatalytic activity for H2O2 reduction. The effects of applied potential and pH of solution upon the response of the modified electrode were investigated for an optimum analytical performance. Even in the presence of dissolved oxygen, the sensor exhibited highly sensitive and rapid response to H2O2. The steady‐state cathodic current responses of the modified electrode obtained at ?0.20 V (vs. SCE) in air‐saturated 0.1 mol L?1 phosphate buffer solution (PBS, pH 6.50) showed a linear relationship to H2O2 concentration ranging from 1.2×10?6 mol L?1 to 6.5×10?4 mol L?1 with a detection limit of 3.1×10?7 mol L?1. Performance of the electrode was evaluated with respected to possible interferences such as ascorbic acid and uric acid etc. The selectivity, stability, and reproducibility of the modified electrode were satisfactory.  相似文献   

8.
A promising electrochemical nitrite sensor was fabricated by immobilizing Au@Fe3O4 nanoparticles on the surface of L ‐cysteine modified glassy carbon electrode, which was characterized by scanning electron microscopy, X‐ray photoelectron spectroscopy, electrochemical impedance spectroscopy and cyclic voltammetry. The proposed sensor exhibited excellent electrocatalytic activity toward nitrite oxidation. The kinetic parameters of the electrode reaction process were calculated, (1–α)nα was 0.38 and the heterogeneous electron transfer coefficient (k) was 0.13 cm s?1. The detection conditions such as supporting electrolyte and pH value were optimized. Under the optimized conditions, the linear range for the determination of nitrite was 3.6×10?6 to 1.0×10?2 M with a detection limit of 8.2×10?7 M (S/N=3). Moreover, the as‐prepared electrode displayed good stability, repeatability and selectivity for promising practical applications.  相似文献   

9.
Ag/MnO2/GO nanocomposites were synthesized via the method of gas/liquid interface based on silver mirror reaction, and a non‐enzymatic H2O2 sensor was fabricated through immobilizing Ag/MnO2/GO nanocomposites on GCE. The composition and morphology of the nanocomposites were studied by energy‐dispersive X‐ray spectroscopy (EDS), X‐ray diffraction (XRD), X‐ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM). Electrochemical investigation indicated that it exhibited a favorable performance for the H2O2 detection. Its linear detection range was from 3 μM to 7 mM with a correlation coefficient of 0.9960; the sensitivity was 105.40 μA mM?1 cm?2 and the detection limit was estimated to be 0.7 μM at a signal‐to‐noise ratio of 3.  相似文献   

10.
We developed a novel iron‐tetrasulfophthalocyanine‐graphene‐Nafion (FeTSPc‐GR‐Nafion) modified screen‐printed electrode to determine hydrogen peroxide (H2O2) with high sensitivity and selectivity. The nanocomposite film (FeTSPc‐GR‐Nafion) exhibits an excellent electrocatalytic activity towards oxidation of H2O2 at a potential of +0.35 V in the absence of enzyme. A comparative study reveals that the FeTSPc‐GR complexes play a dual amplification role. Amperometric experiment indicates that the sensors possess good sensitivity and selectivity, with a linear range from 2.0×10?7 M to 5.0×10?3 M and a detection limit of 8.0×10?8 M. This sensor has been successfully used to develop the glucose biosensor and has also been applied to determine H2O2 in sterile water.  相似文献   

11.
A novel nanocomposite designed by the assembly of the positively charged poly(diallyldimethylammonium chloride) protected gold nanoparticles (PDDA‐GNPs), and the negatively charged multi‐walled carbon nanotubes (MWCNTs) on ITO electrode via electrostatic interaction, was used as a supporting matrix for immobilizing hemoglobin (Hb) to develop a high‐performance hydrogen peroxide (H2O2) biosensor. The cyclic voltammetrys of immobilized Hb showed a pair of well‐defined and quasi‐reversible redox peaks with the formal potential of ‐0.205V (vs. SCE) and the peak‐to‐peak potential separation of 44 mV at a scan rate of 100 mV×s?1 in 0.1 mol×L?1 pH 7.0 PBS. Under the optimized experimental conditions, a linearity range for determination of H2O2 was from 2.0 × 10?6 to 5.2 × 10?4 mol×L?1 with a correlation coefficient of 0.9994 (n = 37) and a detection limit of 8.4 × 10?7 mol×L?1. The biosensor displayed excellent electrochemical and electrocatalytic response to the reduction of H2O2, high sensitivity, long‐term stability, good bioactivity and selectivity.  相似文献   

12.
A novel nonenzymatic H2O2 sensor based on a palladium nanoparticles/graphene (Pd‐NPs/GN) hybrid nanostructures composite film modified glassy carbon electrode (GCE) was reported. The composites of graphene (GN) decorated with Pd nanoparticles have been prepared by simultaneously reducing graphite oxide (GO) and K2PdCl4 in one pot. The Pd‐NPs were intended to enlarge the interplanar spacing of graphene nanosheets and were well dispersed on the surface or completely embedded into few‐layer GN, which maintain their high surface area and prevent GN from aggregating. XPS analysis indicated that the surface Pd atoms are negatively charged, favoring the reduction process of H2O2. Moreover, the Pd‐NPs/GN/GCE could remarkably decrease the overpotential and enhance the electron‐transfer rate due to the good contact between Pd‐NPs and GN sheets, and Pd‐NPs have high catalytical effect for H2O2 reduction. Amperometric measurements allow observation of the electrochemical reduction of H2O2 at 0.5 V (vs. Ag/AgCl). The H2O2 reduction current is linear to its concentration in the range from 1×10?9 to 2×10?3 M, and the detection limit was found to be 2×10?10 M (S/N=3). The as‐prepared nonenzymatic H2O2 sensor exhibits excellent repeatability, selectivity and long‐term stability.  相似文献   

13.
唐明宇袁若  柴雅琴 《中国化学》2006,24(11):1575-1580
The third generation amperometric biosensor for the determination of hydrogen peroxide (H2O2) has been described. For the fabrication of biosensor, o-aminobenzoic acid (oABA) was first electropolymerized on the surface of platinum (Pt) electrode as an electrostatic repulsion layer to reject interferences. Horseradish peroxidase (HRP) absorbed by nano-scaled particulate gold (nano-Au) was immobilized on the electrode modified with polymerized o-aminobenzoic acid (poABA) with L-cysteine as a linker to prepare a biosensor for the detection of H2O2. Amperometric detection of H2O2 was realized at a potential of +20 mV versus SCE. The resulting biosensor exhibited fast response, excellent reproducibility and sensibility, expanded linear range and low interferences. Temperature and pH dependence and stability of the sensor were investigated. The optimal sensor gave a linear response in the range of 2.99×10^-6 to 3.55×10^-3 mol·L^-1 to H2O2 with a sensibility of 0.0177 A·L^-1·mol^-1 and a detection limit (S/N = 3) of 4.3×10^-7 mol·L^-1. The biosensor demonstrated a 95% response within less than 10 s.  相似文献   

14.
In this work, a novel electrochemiluminescent (ECL) pesticide sensor based on zinc oxide nanocrystals decorated nickel foam is proposed for determination of imidacloprid for the first time. The silica film was used as a morphology‐controlling factor for modification of the electrode with zinc oxide nanocrystals. Zinc oxide was selected as luminescent material due to its cheapness, non‐toxicity, high thermal stability and excellent luminescence properties which truly adhered on the surface of nickel foam. The K2S2O8 was used as strong co‐reactant for this purpose. The silica template plays an important role in controlling the size of ZnO nanocrystals. The Physical morphology of the ZnO/Ni‐foam electrode was performed by electrochemical impedance spectroscopy, Brunauer‐Emmett‐Teller (BET), X‐Ray diffraction analysis, field emission scanning electron microscopy, and energy‐dispersive X‐ray analysis. The ultra‐sensitive electrochemiluminescence method was successfully used for ultra‐trace determination of imidacloprid. The linear dynamic range and low detection limit were obtained 3×10?14 ?8×10?8 M and 4.4×10?15 M, respectively. Also, the relative standard deviation for 15 repetitive optical signals was calculated 1.09 %.The present ECL sensor exhibited superior performance toward the accurate determination of imidacloprid with good reproducibility and stability.  相似文献   

15.
A newly nonenzymatic sensor for hydrogen peroxide (H2O2) based on the (Au‐HS/SO3H‐PMO (Et)) nanocomposite is demonstrated. The electrochemical properties of the as‐prepared nanocomposite were studied. It displayed an excellent performance towards H2O2 sensing in the linear response range from 0.20 µM to 4.30 mM (R=0.9999) with a sensitivity of 6.35×102 µA µM?1 cm?2 and a low detection limit of 0.0499 µM. Furthermore, it was not affected by electroactive interference species. These features proved that the modified electrode was suitable for determination of H2O2.  相似文献   

16.
A novel flower like 3D nickel/manganese dioxide (Ni/MnO2) nanocomposite was synthesized by a kind of simple electrochemical method and the formation mechanism of flower like structure was also researched. In addition, morphology and composition of the nanocomposite were characterized by scanning electron microscope (SEM), transmission electron microscopy (TEM), and X‐ray photoelectron spectroscopy (XPS). Then the Ni/MnO2 nanocomposites were applied to fabricate electrochemical non‐enzymatic glucose sensor. The electrochemical investigation for the sensor indicated that it possessed an excellent electrocatalytic property for glucose, and could applied to the quantification of glucose with a linear range from 2.5×10?7 to 3.5×10?3 M, a sensitivity of 1.04 mA mM?1 cm?2, and a detection limit of 1×10?7 M (S/N=3). The proposed sensor also presented attractive features such as interference‐free, and long‐term stability. The present study provided a general platform for the one‐step synthesis of nanomaterials with novel structure and can be extended to other optical, electronic and magnetic nanocompounds.  相似文献   

17.
《Electroanalysis》2018,30(1):137-145
3D Flower‐like manganese dioxide (MnO2) nanostructure with the ability of catalysis for hydrogen peroxide (H2O2) and super large area that can support gold nanoparticles (AuNPs) with enhanced activity of electron transfer have been developed. The nanostructure of hybrids was prepared by directly mixing citric‐capped AuNPs and 3‐aminopropyltriethoxysilane (3‐APTES)‐capped nano‐MnO2 using an electrostatic adsorption strategy. The Au‐MnO2 composite was extensively characterized by scanning electron microscope (SEM), X‐ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), the Brunauer‐Emmett‐Teller (BET) method and X‐ray photoemission spectroscopy (XPS). Electrochemical properties were evaluated through cyclic voltammetry (CV) and amperometric method. The prepared sensor showed excellent electrochemical properties towards H2O2 with a wide linear range from 2.5×10−3∼1.39 mM and 3.89∼13.89 mM. The detection limit is 0.34 μM (S/N=3) with the sensitivities of 169.43 μA mM−1 cm−2 and 55.72 μA mM−1 cm−2. The detection of real samples was also studied. The result exhibited that the prepared sensor can be used for H2O2 detection in real samples.  相似文献   

18.
A nonenzymatic amperometric electrochemical sensor for the detection of hydrogen peroxide (H2O2) was fabricated based on highly dense silver nanowires (Ag NWs) and chitosan (CS) film. Ag NWs were synthesized by a poly(vinyl pyrrolidone) (PVP)‐mediated polyol process in the presence of manganese chloride (MnCl2), and were characterized by scanning electron microscopy (SEM), energy‐dispersive X‐ray spectroscopy (EDS), and X‐ray diffraction (XRD). Under the optimal conditions, the proposed nonenzymatic sensor exhibited good electrocatalytic activity towards the reduction of H2O2, and could detect H2O2 in the linear range of 0.008–1.35 mM, with a detection limit of 2 µM (S/N=3).  相似文献   

19.
A novel sensing material, MnFe2O4/polyaniline (PANI), was fabricated by doping PANI to MnFe2O4 on a modified glassy carbon electrode (GCE). This sensing material was characterized using X‐ray diffraction (XRD), scanning electron microscopy (SEM), and high‐resolution transmission electron microscopy (HR‐TEM). Using a cyclic voltammetry electrochemical‐sensing method, we tested MnFe2O4/PANI, and an acetaminophen concentration of 0.0625–5 mM was recorded. Furthermore, the sensor responses were 2.05–22.44. The detection limit was 2.23 × 10?7 M. Strong selectivity was observed for MnFe2O4/PANI, which is a possible sensing mechanism.  相似文献   

20.
In the present study, a cauliflower‐like NiCo2O4?Zn/Al layered double hydroxide (NiCo2O4?Zn/Al LDH) nanocomposite was used as a novel electrode material for the sensitive and selective determination of pyridoxine (vitamin B6). The structure and morphology of the as‐prepared nanocomposite were characterized by X‐ray diffraction (XRD), FT‐IR, field emission scanning electron microscopy (FESEM) and energy dispersive X‐ray spectroscopy (EDX). The NiCo2O4?Zn/Al LDH nanocomposite exhibited excellent electrocatalytic ability in the oxidation of pyridoxine, which could result from the synergistic effect of the two components. The developed sensor also provided a selective determination of pyridoxine in the presence of other species such as vitamins (B1, B2, B12 and ascorbic acid), inorganic ions and biomolecules. The fabricated sensor showed a good linear response for pyridoxine over the concentration ranges 2×10?7–2.0×10?4 mol L?1 with a low detection limit of 8.6×10?8 mol L?1. Finally, the proposed method was successfully applied for the determination of pyridoxine in commercial tablets and plasma samples with satisfactory results. Furthermore, this novel sensor displayed superior benefits in terms of stability, sensitivity, repeatability and cost. The present work aims to expand NiCo2O4 based nanocomposites to sensor fields and promote the development of pyridoxine sensors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号