首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The aggregation and adhesion of bacterial cells is a serious disadvantage for electrophoretic separations of bacteria. In this study, lipid-based liquid crystalline nanoparticles were used as a pseudostationary phase to minimise the bacterial aggregation and adsorption to the inner walls of microchannels. Lactobacillus delbrueckii subsp. bulgaricus, Streptococcus thermophilus and Lactobacillus rhamnosus were selected as analytes and were separated by microchip electrophoresis (MCE) with laser-induced fluorescence (LIF) detection using 4.5 mM tris(hydroxymethyl) aminomethane (TRIS)-4.5 mM boric acid-0.1 mM ethylenediaminetetraacetate (EDTA) (TBE) containing poly(ethylene oxide) (PEO) and lipid-based nanoparticles as the running buffer. The mechanism of lipid-based nanoparticles affecting bacterial adhesion and aggregation was discussed and supported by zeta potential experiments. Under the optimal conditions, the three species of bacteria were identified with patterned peaks. This proposed MCE method using lipid-based nanoparticles as running buffer additives was also used to analyse a real yogurt sample, and valuable bacterial information was obtained by the electropherograms.  相似文献   

2.
Lee HL  Chen SC 《Talanta》2004,64(1):210-216
Microchip capillary electrophoresis (μCE) with amperometric detection at Cu electrode benefited fast separation and direct detection of carbohydrates. The working electrode of 50-μm Cu wire attached nearly against the channel outlet—4 μm, where it benefited collecting detection current and suppressing overwhelming noise. The use of alkaline medium was essential to separating and detecting carbohydrates, which dissociated into the sensitive alcolate anions. The 10-cm serpentine chip, though lengthening the migration time, it provided better efficiency. Sucrose, cellobiose, glucose, and fructose migrated from the outlet in 400 s +2000 V. The linear calibration plots ranging from 10 to 1000 μM with regression coefficients better than 0.996 were obtained. The injection-to-injection reproducibility of 1.24% (n=7) for glucose in peak current and 0.6% for migration times were excellent. The detection limit was low, down to 2.3 μM for glucose (S/N=3) or 27.6 attomole in mass detection.  相似文献   

3.
Johirul M  Shiddiky A  Kim RE  Shim YB 《Electrophoresis》2005,26(15):3043-3052
A microfluidic chip based on capillary electrophoresis coupled with a cellulose-single-stranded DNA (cellulose-ssDNA) modified electrode was used for the simultaneous analysis of dopamine (DA), norepinephrine (NE), 3,4-dihydroxy-L-phenylalanine (L-DOPA), 3,4-dihydroxyphenylacetic acid (DOPAC), and ascorbic acid (AA). The modification of the electrode improved the electrophoretic analysis performance by lowering the detection potential and enhancing the signal-to-noise characteristic without surface poisoning of the electrode. The sensitivity of the modified electrode was about 12 times higher than those of the bare ones. The test compounds were separated using a 62 mm long separation channel at the separation field strength of +200 V/cm within 220 s in a 10 mM phosphate buffer (pH 7.4). The most favorable potential for the amperometric detection was 0.7 V (vs. Ag/AgCl). A reproducible response (relative standard deviation of 1.3, 1.3, 2.1, 3.1, 3.4% for DA, NE, L-DOPA, DOPAC, and AA, respectively, for n = 9) for repetitive sample injections reflected the negligible electrode fouling at the cellulose-ssDNA modified electrode. Square-wave voltammetric analyses reflected the sensitivities of the modified electrode for DA, NE, L-DOPA, DOPAC, and AA which were 1.78, 0.82, 0.69, 2.45, and 1.23 nC/microM with detection limits of 0.032, 0.93, 1.13, 0.31, and 0.62 microM, respectively. The applicability of this microsystem to real sample analysis was demonstrated.  相似文献   

4.
The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration adjustment takes place when the sample components migrate into the chip during the sample loading step. Using a heart-cutting method, a diluted sample plug is subsequently separated with capillary zone electrophoresis. The excessive dispersion that is typical of the samples with a high ionic strength is thereby prevented. The method can be easily applied to commercially available capillary electrophoresis microchips under the condition that the electroosmotic flow is suppressed. For the first time the lithium concentration is determined in the blood plasma from a patient on lithium therapy without sample pretreatment. Using a microchip with conductivity detection, a detection limit of 0.1 mmol/L is obtained for lithium in a 140 mmol/L sodium matrix.  相似文献   

5.
Huang Y  Zhao S  Shi M  Liu J  Liang H 《Electrophoresis》2012,33(7):1198-1204
A facile and universal strategy for multiplexed immunoassay is proposed. The strategy is based on microchip electrophoresis (MCE) coupled with on-line magnetic separation and chemiluminescence (CL) detection. The system consisted of a microchip, an electromagnet, and a photomultiplier. The realization of multiplexed immunoassay protocol involves sampling magnetic nanoparticles (MNPs) labeled antibodies, N-(4-aminobutyl)-N-ethyl-isoluminol (ABEI) labeled antigens and free antigens in the precolumn reactor, on-line immunoreaction, capturing the MNPs-immunocomplexes, and the separation of unconjugated ABEI-labeled antigens. After on-line magnetic separation, the free ABEI-labeled antigens were transported into the separation channel, and mixed with hydrogen peroxide (H(2) O(2) ) in the presence of horseradish peroxidase in the postcolumn reactor, and producing CL emission. Using this arrangement, multiple analytes could be measured simultaneously by performing the technical operations for a single assay. As a proof-of-concept, the multiplexed immunoassay was evaluated for the simultaneous determination of five model analytes (i.e. hydrocortisone, corticosterone, digoxin, testosterone, and estriol). The results exhibited excellent precision and sensitivity, the relative standard deviations for nine times detection were lower than 4.7% for all the five components, and the detection limits of five analytes were in the range of 3.6-4.9 nM. The MCE system was validated using two human serum-based control samples containing five analytes.  相似文献   

6.
This article describes a novel microchip-based capillary electrophoresis and oncolumn enzymatic reaction analysis protocol for lactate dehydrogenase (LDH) isoenzymes with a home-made xenon lamp-induced fluorescence detection system. A microchip integrated with a temperature-control unit is designed and fabricated for low-temperature electrophoretic separation of LDH isoenzymes, optimal enzyme reaction temperature control, and product detection. A four-step operation and temperature control are employed for the determination of LDH activity by on-chip monitoring of the amount of incubation product of NADH during the fixed incubation period and at a fixed temperature. Experiments on the determination of LDH standard sample and serum LDH isoenzymes from a healthy adult donor are carried out. The results are comparable with those obtained by conventional CE. Shorter analysis times and a more stable and lower background baseline can be achieved. The efficient separation of different LDH forms indicates the potential of microfluidic devices for isoenzyme assay.  相似文献   

7.
We designed and fabricated microfluidic devices with serpentine separation channels and asymmetrically tapered turns, thus allowing high efficiency separations and minimizing band broadening associated with the “racetrack” effect. We evaluated the performance of these devices by measuring the variation in separation efficiency with separation length, electric field strength, taper ratio of the turns, and number of turns. N‐Glycans derived from ribonuclease B and labeled with 8‐aminopyrene‐1,3,6‐trisulfonic acid were electrophoretically separated on serpentine channels with separation lengths of 11, 18, 22, and 36 cm at electric field strengths from 750 to 1750 V/cm. Separations on the 36‐cm channel produced plate numbers up to 940 000 with an analysis time under 3.1 min, whereas separations on the 22‐cm channel had a shorter analysis time (less than 1.25 min), still with respectable efficiencies (up to 600 000 plates). Turn‐induced dispersion was minimized with taper ratios 2 and 3, whereas having two or four 180° turns along with the separation length did not impact the overall efficiency. The developed device was used to analyze native and desialylated N‐glycans derived from the blood serum of an ovarian cancer patient and a disease‐free individual. Separation efficiencies similar to that achieved with the model glycans from ribonuclease B were attained for these biological samples.  相似文献   

8.
Shin D  Tryk DA  Fujishima A  Muck A  Chen G  Wang J 《Electrophoresis》2004,25(17):3017-3023
The attractive features of a boron-doped diamond (BDD) thin-film detector for microchip capillary electrophoretic (CE) separations of dye-related amino-substituted aromatic compounds are described. The diamond electrode was employed in the end-column amperometric detection of 4-aminophenol (4-AP), 1,2-phenylenediamine (1,2-PDA), 2-aminonaphthalene (2-AN), 2-chloroaniline (2-CA), and o-aminobenzoic acid (o-ABA), and its attractive behavior was compared to commonly used screen-printed carbon and glassy-carbon electrodes. These conventional electrode materials exhibit a significant degree of passivation and low sensitivity to the above-mentioned environmental pollutants. The diamond-based electrochemical detection system displayed a favorable analytical performance, including lower noise levels, higher peak resolution with enhanced sensitivity, and improved resistance against electrode passivation. Factors influencing the on-chip analysis were assessed and optimized. The diamond detector displayed detection limits of 2.0 and 1.3 microM for 4-AP and 2-AN, respectively, and a wide linear response for these compounds over the 2-50 microM range. The enhanced stability was demonstrated by relative standard deviation (RSD) values of 1.4% and 4.7% for 100 microM 1,2-PDA and 200 microM 2-CA, respectively, for repetitive detections (n = 7). Besides, the simultaneously observed current decrease was 2.4 and 9.1% for 1,2-PDA and 2-CA, respectively (compared to 21.8 and 41.0% at the screen-printed carbon electrode and 28.3 and 34.1% at the glassy carbon electrode, respectively). The favorable properties of the diamond electrode indicate great promise for environmental applications in CE and other microchip devices.  相似文献   

9.
A thermo-responsive separation matrix, consisting of Pluronic F127 tri-block copolymers of poly(ethylene oxide) and poly(propylene oxide), was used to separate DNA fragments by microchip electrophoresis. At low temperature, the polymer matrix was low in viscosity and allowed rapid loading into a microchannel under low pressure. With increasing temperatures above 25°C, the Pluronic F127 solution forms a liquid crystalline phase consisting of spherical micelles with diameters of 17–19 nm. The solution can be used to separate DNA fragments from 100 bp to 1500 bp on poly(methyl methacrylate) (PMMA) chips. This temperature-sensitive and viscosity-tunable polymer provided excellent resolution over a wide range of DNA sizes. Separation is based on a different mechanism compared with conventional matrices such as methylcellulose. To illustrate the separation mechanism of DNA in a Pluronic F127 solution, DNA molecular imaging was performed by fluorescence microscopy with F127 polymer as the separation matrix in microchip electrophoresis. Figure Temperature dependence of the viscosity of 20% w/w Pluronic F127 solution in 1xTBE buffer. Dotted approximates resultant curve.  相似文献   

10.
A method based on microchip electrophoresis (MCE) with chemiluminescence (CL) detection was developed for the determination of ascorbic acid (AA) and amino acids including tryptophan (Trp), glycine (Gly) and alanine (Ala) present in single cells. Cell injection, loading, lysing, electrophoretic separation and CL detection were integrated onto a simple cross microfluidic chip. A single cell was loaded in the cross intersection by electrophoretic means through applying a set of potentials at the reservoirs. The docked cell was lysed rapidly under a direct electric field. The intracellular contents were MCE separated within 130 s. CL detection was based on the enhancing effects of AA and amino acids on the CL reaction of luminol with K3[Fe(CN)6]. Rat hepatocytes were prepared and analyzed as the test cellular model. The average intracellular contents of AA, Trp, Gly and Ala in single rat hepatocytes were found to be 38.3, 5.15, 3.78 and 3.84 fmol (n = 12), respectively.  相似文献   

11.
Lee HL  Chen SC 《Talanta》2004,64(3):750-757
An integrated multiple-enzymatic assay was performed on a (microchip capillary electrophoresis) μCE-EC chip capable of precise intake of sample or reagents in nanoliters. Incorporating multiple-enzyme assay into the μCE chip is relatively new—rendering simultaneous analysis of creatinine and uric acid a snap.Added to the list of merits in this study are the enhanced sensitivity down to 1 μM and a broader spectrum of analytes—inclusive of glucose for the long-time sufferers of diabetes. The performance was orchestrated to attain the claimed level: employing the end-channel electrode mode to tame the noises and the precolumn enzymatic reaction to stabilize the baseline. The 10 μm embedded Pt electrode, deposited at the end of the 30 μm wide separation channel, benefited chip fabrication besides noise reduction. The optimized conditions were 20 mM phosphate buffer (pH 7.5), +1.5 kV separation voltage and +1.0 V detection potential (versus Ag/AgCl). The migration time was repeatable within the deviation of 0.5% R.S.D. (n=7), but the peak currents ranged from 1.5 to 2.2% R.S.D. The detection limits (S/N=3) ranged from 0.71 μM for ascorbic acid to 10 μM for glucose. The calibration curve was linear from 10 to 800 μM (R2>0.995). Glucose, creatinine, uric acid and ascorbic acid as model analytes, in pure form or in serum and urine samples, were tested to verify its feasibility.  相似文献   

12.
A high-performance monitoring system for human blood glucose levels was developed using microchip electrophoresis with a plastic chip. The combination of reductive amination as glucose labeling with fluorescent 2-aminoacridone (AMAC) and glucose-borate complex formation realized the highly selective detection of glucose even in a complex matrix such as a blood sample. The migration time of a single peak, observed on an electropherogram of AMAC-labeled plasma, closely resembled that of glucose standard solution. The treatment of plasma with hexokinase or glucokinase for glucose phosphorylation resulted in a peak shift from approximately 145 to 70 s, corresponding to glucose and glucose-6-phosphate, respectively. A double-logarithm plot revealed a linear relationship between glucose concentration and fluorescence intensity in the range of 1-300 microM of glucose (r(2) = 0.9963; p <0.01), and the detection limit was 0.92 microM. Furthermore, blood glucose concentrations estimated from the standard curves of three subjects were compared with results obtained by conventional colorimetric analysis using glucose dehydrogenase. Good correlation was observed between methods according to simple linear regression analysis (p <0.05). The reproducibility of the assay was about 6.3-9.1% (RSD) and the within-days and between-days reproducibility were 1.6-8.4 and 5.2-7.2%, respectively. This system enables us to determine blood glucose with high sensitivity and accuracy, and will be applicable to clinical diagnosis.  相似文献   

13.
《Electrophoresis》2018,39(14):1802-1807
An improved method for the concurrent determination and separation of cations and anions by microchip electrophoresis with capacitively coupled contactless conductivity detection (ME‐C4D) is described. Two kinds of microchip structures were designed. The first microchip has a long bent separation channel. And for the defects of the first microchip, the second microchip with a Y‐type separation channel has been proposed. The background electrolyte (BGE) composed of 20 mm His/MES and 0.01 mm CTAB was optimized for inhibiting the electroosmotic flow (EOF). Due to the low electroosmotic flow, the cations and anions migrate in opposite directions and can be separated from each other. With the precisely controlled high‐voltage, cations and anions can be migrated in microchannels according to our requirements and sequentially detected by a C4D detector built in‐house. Samples containing K+, Na+, Li+, Cl, F and PO43− were analyzed simultaneously in a single run (within 140 s) by both methods. The reproducibility obtained by both methods remained below 5% for migration time and within 3.5–9.1% for peak areas. The proposed concurrent determination methods are inexpensive, simple, fast, ease of operation, high degree of integration.  相似文献   

14.
In this paper we explored the use of fluorescently labelled vancomycin to specifically bind and detect Staphylococcus aureus based on an on-line multiple-concentration on microchip electrophoresis.  相似文献   

15.
Progress made in the last five years in the application of capillary electrophoresis methods to chemical speciation of elements is reported on the basis of over 100 literature references. The main trends observed include development of new on‐ and off‐capillary derivatization methods, application of new detection methods, and especially coupling of CE separation systems to powerful atomic spectroscopy and mass spectrometry instruments with various ionization techniques, providing either a sensitive element‐specific detection method or a third dimension for high performance separation. Besides numerous CZE and MEKC capillary electrophoresis methods only very few examples of CE speciation with capillary electrochromatography can be found. Concerning the chemical forms of elements determined, the new procedures developed are mostly focused on redox speciation of various oxidation states of elements, metal‐bound high molecular compounds, and organometallic species.  相似文献   

16.
We report a diagnostic method for Anaplasma phagocytophilum (A. phagocytophilum) infection in cattle using a nested PCR and microchip electrophoresis (ME). A. phagocytophilum causes human granulocytic anaplasmosis and granulocytic ehrlichiosis, which are emerging tick‐borne zoonotic diseases. Nested PCR was used to amplify genomic DNA samples extracted from cattle blood. The amplified PCR products were analyzed under a sieving gel matrix of 0.7% poly(ethyleneoxide) (Mr=8 000 000) in a conventional glass microchip. In the ME assay, A. phagocytophilum was analyzed within 35 s with a relative standard deviation of 1.30% (n=5) using a programmed field strength gradient (PFSG) as follows: 615.3 V/cm for 0–24 s, 66.7 V/cm for 24–34 s, 615.3 V/cm for 34–100 s. The ME‐PFSG assay was clinically validated by comparing the 16S rRNA gene levels obtained by this method with those measured using conventional slab gel electrophoresis performed with ten cattle blood samples suspected of A. phagocytophilum infection. In contrast to slab gel electrophoresis, the proposed ME‐PFSG methodology had increased sensitivity (200–450 pg/μL), a faster analysis time (<35 s), and required a smaller sample volume (~162 fL).  相似文献   

17.
Kang SH  Park M  Cho K 《Electrophoresis》2005,26(16):3179-3184
We evaluated a novel strategy for fast diagnosis by microchip electrophoresis (ME), using programmed field strength gradients (PFSG) in a conventional glass double-T microfluidic chip. The ME-PFSG allows for the ultrafast separation and enhanced resolving power for target DNA fragments. These results are based on electric field strength gradients (FSG) that use an ME separation step in a sieving gel matrix poly-(ethylene oxide). The gradient can develop staircase or programmed shapes FSG over the time. The PFSG method could be easily used to increase separation efficiency and resolution in ME separation of specific size DNA fragments. Compared to ME that uses a conventional and constantly applied electric field (isoelectrostatic) method, the ME-PFSG achieved about 15-fold faster analysis time during the separation of 100 bp DNA ladder. The ME-PFSG was also applied to the fast analysis of the PCR products, 591 and 1191 bp DNA fragments from the 18S rRNA of Babesia gibsoni and Babesia caballi.  相似文献   

18.
In the current paper, enzyme enhanced simultaneous quantitative determination of multiple DNA targets based on capillary electrophoresis (CE) was described. We used three biotin-modified DNA probes, which reacted with avidin-conjugated horseradish peroxidase (avidin-HRP) conjugate to obtain the HRP labeled probes, to hybridize with three corresponding targets. The resulting mixture containing double-strand DNA (dsDNA)-HRP, excess single-strand DNA (ssDNA)-HRP and remaining avidin-HRP was separated by capillary electrophoresis, and then the system of HRP catalyzing H2O2/o-aminophenol (OAP) reaction was adopted. The catalytic product was detected with electrochemical detection. With this protocol, the limits of quantification for the hybridization assay of 21-, 39- and 80-mer DNA fragments were of 1.2 × 10−11, 2.4 × 10−11 and 3.0 × 10−11 M, respectively. The multiplex assay also provided good specificity without any cross-reaction.  相似文献   

19.
This article reports on the use of cobalt(II) phthalocyanine (CoPc)-modified carbon paste amperometric detector for monitoring hydrazine compounds following their microchip separation. The marked catalytic electrochemical properties of CoPc-modified electrode display enhanced sensitivity compared with unmodified carbon pastes at a relatively low detection potential (+0.5 V versus Ag/AgCl). Factors influencing the on-chip separation and detection processes have been optimized. Three hydrazines (hydrazine, 1,1 dimethylhydrazine, and phenylhydrazine) have been separated within 130 s at a separation voltage of 1 kV using a 10 mM phosphate run buffer (pH 6.5). The detection limits obtained from using the CoPc-modified carbon paste electrodes for hydrazine and phenylhydrazine are 0.5 and 0.7 μM, respectively, with linearity over the 20–200 μM range examined. Such miniaturization and speed advantages of microchip CE are coupled to the highly sensitivity and convenient preparation of CoPc-modified carbon paste electrode. The resulting microsystem should be attractive for field monitoring of toxic hydrazine compounds in environmental applications.  相似文献   

20.
The performance of the most common and also some other less common CE buffers has been tested for the pKa determination of several types of compounds (pyridine, amines, and phenols). The selected buffers cover a pH ranging from 3.7 to 11.8. Whereas some buffers, like acetic acid/acetate, BisTrisH+/BisTris, TrisH+/Tris, CHES/CHES-, and CAPS/CAPS- can be used with all type of analytes, others like ammonium/ammonia, butylammonium/butylammonia, ethylammonium/ethylammonia, diethylammonium/diethylammonia, and hydrogenphosphate/phosphate are not recommended because they interact with a wide range of compounds. The rest of the tested buffers (dihydrogenphosphate/hydrogenphosphate, MES/MES-, HEPES/HEPES-, and boric acid/borate) can show specific interactions depending on the nature of the analytes, and their use in some applications should be restricted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号