首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
This work reports the advantages of using glassy carbon electrodes modified with multiwall carbon nanotubes (MWCNT) dispersed in polyethylenimine (PEI). The presence of MWCNTs wrapped by PEI largely facilitated the strong adsorption of uric acid (UA) and allowed its highly sensitive and selective quantification even in the presence of high excess of ascorbic acid. The selected conditions for the electrochemical sensing were 5 s accumulation at ?0.300 V under stirring and quantification in a 0.050 M phosphate buffer solution pH 7.40 by differential pulse voltammetry adsorptive‐stripping after medium exchange. The platform allowed the successful application in the quantification of UA in urine.  相似文献   

2.
We report the analytical performance of glassy carbon electrodes (GCE) modified with a dispersion of multiwall carbon nanotubes (MWCNT) in polylysine (Plys) (GCE/MWCNT‐Plys). The resulting electrodes show an excellent electrocatalytic activity towards different bioanalytes like ascorbic acid, uric acid and hydrogen peroxide, with important decrease in their oxidation overvoltages. The dispersion of 1.0 mg/mL MWCNT in 1.0 mg/mL polylysine is highly stable, since after 2 weeks the sensitivity for hydrogen peroxide at GCE modified with this dispersion remained in a 90% of the original value. The MWCNT‐Plys layer immobilized on glassy carbon electrodes has been also used as a platform to build supramolecular architectures by self‐assembling of polyelectrolytes based on the polycationic nature of the polylysine used to disperse the nanotubes. The self‐assembling of glucose oxidase has allowed us to obtain a supramolecular multistructure for glucose biosensing. The influence of glucose oxidase concentration and adsorption time as well as the effect of using polylysine or MWCNT‐Plys as polycationic layers for further adsorption of GOx is also evaluated.  相似文献   

3.
We report the advantages of the adsorption and electrooxidation of oligonucleotides and calf‐thymus double stranded DNA (dsDNA) at glassy carbon electrodes (GCE) modified with a dispersion of multiwalled carbon nanotubes (MWCNT) in poly‐L ‐lysine (Plys) (GCE/MWCNT‐Plys). Important enhancement in the guanine oxidation signal was obtained by adsorptive stripping voltammetry (AdSV) due to a most favorable interaction between the negatively charged DNAs and the positively charged Plys that support the MWCNT. The layer of oligo(dG)11 immobilized at GCE/MWCNT‐Plys was successfully used for the selective detection of the hybridization event using oligo(dG)11/oligo(dC)11 as model.  相似文献   

4.
The effect of surface modifications on the electrochemical behavior of the anticancer drug idarubicin was studied at multiwalled carbon nanotubes modified glassy carbon and edge plane pyrolytic graphite electrodes. The surface morphology of the modified electrodes was characterized by scanning electron microscopy. The modified electrodes were constructed for the determination of idarubicin using adsorptive stripping differential pulse voltammetry. The experimental parameters such as supporting electrolyte, pH, accumulation time and potential, amount of carbon nanotubes for the sensitive assay of idarubicin were studied as details. Under the optimized conditions, idarubicin gave a linear response in the range 9.36×10?8–1.87×10?6 M for modified glassy carbon and 9.36×10?8–9.36×10?7 M for modified edge plane pyrolytic graphite electrodes. The detection limits were found as 1.87×10?8 M and 3.75×10?8 M based on modified glassy carbon and edge plane pyrolytic graphite electrodes, respectively. Interfering species such as ascorbic acid, dopamine, and aspirin showed no interference with the selective determination of idarubicin. The analyzing method was fully validated and successfully applied for the determination of idarubicin in its pharmaceutical dosage form. The possible oxidation mechanism of idarubicin was also discussed. The results revealed that the modified electrodes showed an obvious electrocatalytic activity toward the oxidation of idarubicin by a remarkable enhancement in the current response compared with bare electrodes.  相似文献   

5.
We report a dopamine electrochemical sensor based on the modification of glassy carbon electrodes (GCE) with polylysine‐functionalized single‐wall carbon nanotubes (SWCNT‐PLys). The resulting electrodes (GCE/SWCNT‐PLys) showed a significant improvement in the electrooxidation of dopamine with drastic decrease in the peak potentials separation and important enhancement in the associated currents. Dopamine was detected by differential pulse voltammetry‐adsorptive stripping with medium exchange at nanomolar levels even in the presence of high excess of ascorbic and uric acids. The sensor was successfully used for the quantification of dopamine in urine samples enriched with the neurotransmitter.  相似文献   

6.
We are proposing for the first time the successful immobilization of DNA at glassy carbon electrodes (GCE) modified with carbon nanotubes (CNT) dispersed in glucose oxidase (GOx) (GCE/CNT‐GOx) either by direct adsorption or by layer‐by‐layer self‐assembling using polydiallyldimethylamine (PDDA). The presence of GOx allows an efficient dispersion of CNT and gives a most favorable environment that promotes the adsorption and makes possible a more sensitive electrooxidation of DNA. The PDDA incorporated in the self‐assembled architecture largely facilitates the adsorption and electrooxidation of dsDNA and the adsorbed layer can be successfully used for evaluating the interaction of DNA with methylene blue.  相似文献   

7.
Mercury film plated on a glassy carbon electrode modified with multiwalled carbon nanotubes (MF/MWNTs/GCE) was used for the analysis of single (ss) and double stranded (ds) DNA, as well as for Jurkat genomic DNAs methylated to different degrees. The results indicated that the DNA molecules adsorbed quite strongly on the MF/MWNTs/GCE surface allowing ex situ adsorption and produce well developed peaks (due to cytosine and adenine) by using adsorptive stripping (Ads, ex situ) square wave voltammetry (SWV). Also, SWV of Jurkat DNA mixtures methylated to different degrees revealed a linear decrease of the peak height with increasing methylation indicating an increase of structural rigidity.  相似文献   

8.
This work describes the development, electrochemical characterization and utilization of a cobalt phthalocyanine modified carbon nanotube electrode for the quantitative determination of dopamine in 0.2 mol L?1 phosphate buffer contaminated with high concentration of ascorbic acid. The electrode surface was analyzed by cyclic voltammetry and electrochemical impedance spectroscopy which showed a modified surface presenting a charge transfer resistance of 500 Ω, against the 16.46 kΩ value found for the bare glassy carbon surface. A pseudo rate constant value of 5.4×10?4 cm s?1 for dopamine oxidation was calculated. Voltammetric experiments showed a shift of the peak potential of DA oxidation to less positive value at 390 mV as compared with that of a bare GC electrode at 570 mV. The electrochemical determination of dopamine, in presence of ascorbic acid in concentrations up to 0.1 mol L?1 by differential pulse voltammetry, yielded a detection limit as low as 2.56×10?7 mol L?1.  相似文献   

9.
《Electroanalysis》2006,18(23):2385-2388
Electrochemical reduction of Deoxycholic acid (DCA), as important biological molecule has been studied in 0.05 M KH2PO4 aqueous methanol solution (1 : 1, v/v) at a multiwalled carbon nanotubes modified electrode. Based on cyclic voltammetry, Tafel plot, the possible mechanism of the electrochemical reduction of DCA was investigated, as well as DCA mechanical calculations. The transfer coefficient, α, the exchange current density, i0, the diffusion coefficient, D0 at the MWCNT modified GCE were determined as 0.505, 5.655×10?7 A/cm2 and 1.579×10?5 cm2/s, respectively. The results of chronoamperometric suggested that the reductive product of DCA was the corresponding hydroxymethyl compound in an over‐all four‐electron process.  相似文献   

10.
A multiwalled carbon nanotube/chitosan modified glassy carbon electrode (MWCNTs‐CHT/GCE) has been used for simultaneous determination of paracetamol (PAR) and uric acid (UA). The measurements were carried out using differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA). DPV measurements showed a linear relationship between oxidation peak current and concentration of PAR and UA in phosphate buffer (pH 7) over the concentration range 2 µM to 250 µM, and 10 µM to 400 µM, respectively. The analytical performance of this sensor has been evaluated for detection of PAR and UA in human serum and human urine with satisfactory results.  相似文献   

11.
《Electroanalysis》2006,18(15):1471-1478
In this paper, we present an electrochemical impedance‐based DNA biosensor by using a composite material of polypyrrole (PPy) and multiwalled carbon nanotubes (MWNTs) to modify glassy carbon electrode (GCE). The polymer film was electropolymerized onto GCE by cyclic voltammetry (CV) in the presence of carboxylic groups ended MWNTs (MWNTs‐COOH). Such electrode modification method is new for DNA hybridization sensor. Amino group ended single‐stranded DNA (NH2‐ssDNA) probe was linked onto the PPy/MWNTs‐COOH/GCE by using EDAC, a widely used water‐soluble carbodiimide for crosslinking amine and carboxylic acid group. The hybridization reaction of this ssDNA/PPy/MWNTs‐COOH/GCE resulted in a decreased impedance, which was attributed to the lower electronic transfer resistance of double‐stranded DNA than single‐stranded DNA. As the result of the PPy/MWNTs modification, the electrode obtained a good electronic transfer property and a large specific surface area. Consequently, the sensitivity and selectivity of this sensor for biosensing DNA hybridization were improved. Complementary DNA sequence as low as 5.0×10?12 mol L?1 can be detected without using hybridization marker or intercalator. Additionally, it was found that the electropolymerization scan rate was an important factor for DNA biosensor fabrication. It has been optimized at 20 mV s?1.  相似文献   

12.
《Analytical letters》2012,45(17):2813-2828
The goal of this study was to develop a suitable electroanalytical method for the determination of primary compounds in the extracts of capsaicin and silymarin. For this purpose, a glassy carbon electrode immobilized with multiwalled carbon nanotubes decorated with gold nanoparticles was characterized by high resolution transmission electron microscopy and attenuated total reflectance infrared spectroscopy. The developed electrochemical sensor had a linear dynamic range from 0.15 to 35.0 µM. In addition, the limits of quantification for silymarin and capsaicin with the gold nanoparticle decorated multiwalled carbon nanotubes were 0.1564 and 0.2761 µg L?1 with relative standard deviations (n = 3) of 1.65% and 2.09% and equivalent mass percentages of 93.33% and 62.02%, respectively. The methodology may be employed for the determination of capsaicin and silymarin in pharmaceutical and food products.  相似文献   

13.
《Analytical letters》2012,45(14):2370-2383
Carbon nanotubes have been intensively studied for their diverse applications but are insoluble in water. In this paper, 3,4,9,10-perylene tetracarboxylic acid noncovalently modified multiwalled carbon nanotubes were prepared by a facile approach and applied successfully for electrochemical determination of 2-aminonaphthalene. Infrared spectroscopy, Raman spectroscopy, thermogravimetric analysis, and electrochemical methods were used to characterize the hybridized nanotubes. The results reveal that the hybrids exhibit high dispersibility in water, and a glassy carbon electrode modified by the hybrids displayed a higher electrochemical response toward 2-aminonaphthalene than bare glassy carbon and multiwalled carbon nanotube–glassy carbon electrodes with a linear dynamic range of 15.0–500.0 nM and a detection limit of 4.5 nM. The modified hybrid electrode was successfully applied for the determination of 2-aminonaphthalene in water.  相似文献   

14.
It has been suggested that multiwalled carbon nanotubes (MWCNTs) interacting with pharmaceutics may be introduced into the body as nanocarriers. To deliver the anticancer drugs, covalent or noncovalent functionalization of MWCNTs is required. In this study, the influence of oxidation on MWCNTs in the interaction with chemotherapeutic drug, doxorubicin, was characterized. The binding of doxorubicin with MWCNTs decreased rapidly with the increasing oxidation period with sulfuric acid. However, with nitric acid, the interaction increased initially and slowly decreased with time. The best results were obtained for sulfuric and nitric acid following 1 and 3?h of oxidation, respectively. The results show that sulfuric acid provided more favorable interaction for MWCNTs with doxorubicin than nitric acid.  相似文献   

15.
基于羧基化多壁碳纳米管修饰的玻碳电极(CMWCNTs/GCE),构建了一种灵敏检测氨基脲(SEM)的电化学传感器.采用傅里叶变换红外光谱、透射电子显微镜、电化学阻抗谱对修饰材料进行表征.结果表明,羧基化的多壁碳纳米管出现羧基碳氧双键的红外特征峰,管径明显减小,长度变短,电化学阻抗值显著减小.在1 mol/L HAc-NaAc缓冲液中,利用循环伏安法和时间-电流曲线研究了SEM在CMWCNTs修饰电极上的电化学行为.SEM在修饰电极上呈现不可逆的氧化峰.与裸电极相比,氧化峰电流明显增大.在最佳实验条件(pH 7.0,扫描速度为0.1 V/s)下,测得SEM在5.00×10-6~1.09×10-3mol/L浓度范围内与氧化峰电流呈线性关系,线性方程为IP(μA)=-0.472+0.0599C(μmol/L),相关系数r=0.997,检出限为1.88×10-7 mol/L(S/N=3).在实际猪肝样品检测中加标回收率为92.8%~98.0%.  相似文献   

16.
《Electroanalysis》2005,17(10):873-879
A highly sensitive and fast responding sensor for the determination of morphine is described. The multiwall carbon nanotubes immobilize on preheated glassy carbon electrode (5 min at 50 °C) by gently rubbing of electrode surface on a filter paper supporting the carbon nanotubes.The results indicated that carbon nanotubes(CNTs) modified glassy carbon electrode exhibited efficiently electrocatalytic oxidation for morphine with relatively high sensitivity, stability and long life. Under conditions of cyclic voltammetry, the potential for oxidation of morphine is lowered by approximately 100 mV and the current is enhanced significantly (10 times) in comparison to the bare glassy carbon electrode at wide pH range (2–9). The electrocatalytic behavior is further exploited as a sensitive detection scheme for morphine determination by hydrodynamic amperometry. Under the optimized conditions the calibration plots are linear in the concentration range 0.5–150 μM with the calculated detection limit (S/N=3) of 0.2 μM and sensitivity of 10 nA/μM and a relative standard deviation (RSD) of 2.5% (n=10). The amperometric response is extremely stable, with no loss in sensitivity over a continual 30 min operation. Such attractive ability of multiwall carbon nanotubes (MWCNTs) modified GC electrode, suggests great promise for a morphine amperometric sensor. Finally the ability of the modified electrode was evaluated for simultaneous determination of morphine and codeine.  相似文献   

17.
《Electroanalysis》2004,16(20):1697-1703
An amperometric glucose biosensor based on multi‐walled carbon nanotube (MWCNT) modified glassy carbon electrode has been developed. MWCNT‐modified glassy carbon electrode was obtained by casting the electrode surface with multi‐walled carbon nanotube materials. Glucose oxidase was co‐immobilized on the MWCNT‐modified glassy carbon surface by electrochemical deposition of poly(o‐phenylenediamine) film. Enhanced catalytic electroreduction behavior of oxygen at MWCNT‐modified electrode surface was observed at a potential of ?0.40 V (vs. Ag|AgCl) in neutral medium. The steady‐state amperometric response to glucose was determined at a selected potential of ?0.30 V by means of the reduction of dissolved oxygen consumed by the enzymatic reaction. Common interferents such as ascorbic acid, 4‐acetamidophenol, and uric acid did not interfere in the glucose determination. The linear range for glucose determination extended to 2.0 mM and the detection limit was estimated to be about 0.03 mM.  相似文献   

18.
《Electroanalysis》2004,16(17):1444-1450
The multi‐walled carbon nanotubes (MWNTs) modified glassy carbon electrode exhibited electrocatalytic activity to the reduction of oxygen in 0.1 M HAc‐NaAc (pH 3.8) buffer solution. Further modification with cobalt porphyrin film on the MWNTs by adsorption, the resulted modified electrode showed more efficient catalytic activity to O2 reduction. The reduction peak potential of O2 is shifted much more positively to 0.12 V (vs. Ag/AgCl), and the peak current is increased greatly. Cyclic voltammetry (CV), transmission electron microscopy (TEM), X‐ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM), were used to characterize the material and the modified film on electrode surface. Electrochemical experiments gave the total number of electron transfer for oxygen reduction as about 3, which indicated a co‐exist process of 2 electrons and 4 electrons for reduction of oxygen at this modified electrode. Meanwhile, the catalytic activities of the multilayer film (MWNTs/CoTMPyP)n prepared by layer‐by‐layer method were investigated, and the results showed that the peak current of O2 reduction increased and the peak potential shifted to a positive direction with the increase of layer numbers.  相似文献   

19.
《Electroanalysis》2006,18(18):1786-1792
Electrochemical detection of quercetin has been carried out on glassy carbon electrodes modified with carbon nanotubes and Nafion (GC/Nafion‐CNT). GC/Nafion‐CNT electrodes did not show passivation effect that occurs on the unmodified electrodes and displayed better stability and reproducibility. Quercetin oxidation was most favorable in acidic conditions and current gradually decreased as the solution pH increased. No oxidation was observed when two ? OH groups in a catechol moiety were fully deprotonated. These electrodes enabled selective determination of quercetin in the presence of interfering species such as ascorbic acid, uric acid, glucose, and catechol in large excess. Quantification of quercetin in a yellow onion has been made and favorably compared with reported values. Good selectivity and high sensitivity obtained by Osteryoung sSquare‐wave voltammetry can open new possibilities of direct quercetin determination in vegetables with a minimal sample treatment.  相似文献   

20.
制备了多壁碳纳米管修饰玻碳电极,研究了对乙酰氨基酚在多壁碳纳米管修饰电极上的循环伏安行为,并建立了测定对乙酰氨基酚含量的电化学分析方法。在pH为6.89的磷酸盐缓冲液中,多壁碳纳米管修饰电极对对乙酰氨基酚有明显的电催化作用,其氧化峰电流与对乙酰氨基酚浓度在1.0×10-6~1.0×10-4mol·L-1范围内呈良好的线性关系,检测限为2.0×10-7mol·L-1。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号