首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 749 毫秒
1.
A simple porogen containing only DMF and aqueous buffer was used for synthesis of monolithic stationary media for CEC). Butyl methacrylate (BMA)‐based capillary monoliths were obtained using proposed porogen together with acrylic/methacrylic cross‐linking agents with different alkyl chain lengths. For this purpose, ethylene glycol dimethacrylate, butanediol dimethacrylate and hexanediol diacrylate (HDDA) were used. The monoliths with better electrochromatographic separation performance were obtained when the acrylic cross‐linking agent with the longest alkyl chain length (i.e. HDDA) was used with the proposed porogen. The electrochromatographic separation of alkylbenzenes, phenols and benzoic acids were sucessfully performed in CEC particularly using poly(BMA‐co‐HDDA) monolithic stationary phase with the column efficiency up to 270 000 plates/m.  相似文献   

2.
A solid‐phase microextraction (SPME) fiber coated with poly(methacrylic acid‐ethylene glycol dimethacrylate) coupled to GC with a micro electron‐capture detector was developed for the determination of four chlorphenols in water samples for the first time. A novel and simple method for the preparation of this novel SPME fiber was proposed by copolymerization of methacrylic acid and ethylene glycol dimethacrylate in an appropriate solvent using a glass capillary as a “mold”. The factors affecting the polymerization were optimized in detail. Furthermore, the extraction performance of the poly(methacrylic acid‐ethylene glycol dimethacrylate) fiber was evaluated. Moreover, experimental headspace‐SPME parameters, such as extraction temperature, extraction time, salt concentration, stirring speed, and pH, were optimized by orthogonal array experimental designs. Under the optimized conditions, the target analytes were linear in the range of 0.2–50 ng/mL, and the correlation coefficients were all greater than 0.99. RSD was less than 8.9%, and the detection limits were in the range of 0.1–10 ng/L. Four cholorphenols were detected from tap and lake water samples using the proposed method, with the recoveries of spiked natural water samples were ranged from 91.8 to 110.8, and 90.6 to 111.4% for tap and lake water samples, respectively.  相似文献   

3.
In this study, an open‐tubular capillary electrochromatography (OT‐CEC) column with a monolithic layer of molecularly imprinted polymer (MIP) based on methacrylic acid, ethylene glycol dimethacrylate, and 4‐styrenesulfonic acid was utilized for the simultaneous separation and characterization of phospholipid (PL) molecular structures by interfacing with electrospray ionization‐tandem mass spectrometry (ESI‐MS‐MS). Introducing an MIP‐based monolith along with charged species at the OT column made it possible to separate PL molecules based on differences in head groups and acyl chain lengths in CEC. For the interface of OT‐CEC with ESI‐MS‐MS, a simple nanospray interface utilizing a sheath flow was developed and the resulting OT‐CEC‐ESI‐MS‐MS was able to separate PL standards (phosphatidylserines, phosphatidylethanolamines, phosphatidylglycerols, phosphatidic acid, and lysophosphatidylglycerols). The developed method was applied to human urinary lipid extracts, and resulted in the separation and structural identification of 18 molecules by data‐dependent collision‐induced dissociation.  相似文献   

4.
Shabi Abbas Zaidi 《Electrophoresis》2013,34(9-10):1375-1382
To extend the application of molecularly imprinted polymers, the dual‐templates molecularly imprinted monolithic columns were developed in a capillary format. Two templates serotonin and histamine were simultaneously imprinted using two different functional monomers such as methacrylic acid (MAA) and methylenesuccinic acid (MSA) in a mixture of ethylene glycol dimethacrylate (EDMA) as a cross‐linker and AIBN as polymerization initiator dissolved in DMF as porogen. The resulting molecular imprinted polymers (MIPs) were characterized based on their performance in the CEC separation of two imprinted templates. The optimization parameters such as pH, ACN composition, and concentration of the eluent were varied to achieve best resolution and efficiency for CEC separation of templates with each MIP column. It was found that the MIP monolith column fabricated using MSA offered better resolution and separation efficiency compared to column fabricated with MAA. This work utilized the dual‐templates imprinting approach successfully and broadens the scope of multi‐templates imprinting capabilities in capillary format in CEC application.  相似文献   

5.
A sensitive microextraction method based on a new poly(methacrylic acid‐ethylene glycol dimethacrylate‐N‐vinylcarbazole) monolithic capillary column, coupled with gas chromatography and electron capture detection, was established for the determination of three benzodiazepines (estazolam, alprazolam, and triazolam) in urine and beer samples. Owing to the abundant π electrons and polar surface of N‐vinylcarbazole, N‐vinylcarbazole‐incorporated monolith showed a higher extraction performance than neat poly(methacrylic acid‐ethylene glycol dimethacrylate) because of the enhanced π–π stacking interactions derived from the π‐electron‐rich benzene groups from N‐vinylcarbazole. The monolith exhibited a homogeneous and continuous structure, good permeability, and a long lifetime. Factors affecting the extraction such as solution pH, salt concentration, sample volume, desorption solvent, and desorption volume were investigated. Under the optimized conditions, limits of detection of 0.011–0.026 ng/mL were obtained. The one‐column and column‐to‐column precision values were ≤7.2 and ≤9.8%, respectively. The real samples were first diluted with deionized water and then treated by the monolith microextraction before gas chromatography analysis. The recoveries were 81.4–93.3 and 83.3–94.7% for the spiked samples, with relative standard deviations of 4.1–8.1 and 3.8–8.5%, respectively. This method provides an accurate, simple, and sensitive detection platform for drug analysis.  相似文献   

6.
甲基丙烯酸基质的毛细管电色谱整体柱的制备与应用   总被引:1,自引:0,他引:1  
以甲基丙烯酸(MAA)为功能单体,同时又作电渗流改性剂, 乙二醇二甲基丙烯酸酯(EDMA)为交联剂,甲苯和异辛烷为致孔剂,Irgacure 1800为光引发剂,采用紫外光引发原位聚合反应制备出毛细管电色谱整体柱.对影响电渗流的因素如pH、乙腈含量及离子强度等进行了讨论.使用制备的整体柱在3种模式(加压电色谱、气压驱动和电色谱)下对7种中性物质(硫脲、苯、甲苯、乙苯、萘、联苯和菲)的混合物实现基线分离,同时还可实现酸性物质(邻羟基苯甲酸、苯甲酸、苯乳酸、扁桃酸)和碱性物质(苯胺、甲苯胺、乙酰基苯胺和N-甲基苯胺)的快速分离.  相似文献   

7.
Wei F  Fan Y  Zhang M  Feng YQ 《Electrophoresis》2005,26(16):3141-3150
A method based on in-tube solid-phase microextraction and capillary zone electrophoresis (CZE) was proposed for simultaneously determining four amphetamines (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxymethamphetamine) in urine. A poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column, which can provide sufficient extraction efficiency, was introduced for the extraction of amphetamines from urine samples. The hydrophobic main chains and acidic pendant groups of the monolithic column make it a superior material for extraction of basic analytes from aqueous matrix. After extraction, the samples were analyzed by CZE. The best separation was achieved using a buffer composed of 0.1 M disodium hydrogen phosphate (adjusted to pH 4.5 with 1 M hydrochloric acid) and 20% methanol v/v, with a temperature and voltage of 25 degrees C and 20 kV, respectively. By applying electrokinetic injection with field-amplified sample stacking, detection limits of 25-34 microg/L were achieved. Excellent method of reproducibility was found over a linear range of 0.1-5 mg/L. Determination of these analytes from abusers' urine sample was also demonstrated.  相似文献   

8.
Monolithic columns were synthesized inside 1.02 mm internal diameter fused‐silica lined stainless‐steel tubing. Styrene and butyl, hexyl, lauryl, and glycidyl methacrylates were the functional monomers. Ethylene glycol dimethacrylate and divinylbenzene were the crosslinkers. The glycidyl methacrylate polymer was modified with gold nanoparticles and dodecanethiol (C12). The separation of alkylbenzenes was investigated by isocratic elution in 60:40 v/v acetonitrile/water. The columns based on polystyrene‐co‐divinylbenzene and poly(glycidyl methacrylate)‐co‐ethylene glycol dimethacrylate modified with dodecanethiol did not provide any separation of alkyl benzenes. The poly(hexyl methacrylate)‐co‐ethylene glycol dimethacrylate and poly(lauryl methacrylate)‐co‐ethylene glycol dimethacrylate columns separated the alkyl benzenes with plate heights between 30 and 60 μm (50 μL min?1 and 60°C). Similar efficiency was achieved in the poly(butyl methacrylate)‐co‐ethylene glycol dimethacrylate column, but only at 10 μL min?1 (0.22 mm s?1). Backpressures varied from 0.38 MPa in the hexyl methacrylate to 13.4 MPa in lauryl methacrylate columns (50 μL min?1 and 60°C). Separation of proteins was achieved in all columns with different efficiencies. At 100 μL min?1 and 60°C, the lauryl methacrylate columns provided the best separation, but their low permeability prevented high flow rates. Flow rates up to 500 μL min?1 were possible in the styrene, butyl and hexyl methacrylate columns.  相似文献   

9.
An analytical method based on online combination of polymer monolith microextraction (PMME) technique with hydrophilic interaction LC (HILIC)/MS is presented. The extraction was performed with a poly(methacrylic acid‐co‐ethylene glycol dimethacrylate) monolithic column while the subsequent separation was carried out on a Luna silica column by HILIC. After 1:1 v/v dilution with 20 mM phosphate solution at pH 7.0 and centrifugation, urine sample was directly used for extraction. After optimization, 85% ACN (containing 0.3% formic acid v/v) was used for rapid online elution, which was also the mobile phase in HILIC to avoid band broadening during separation or carry‐over that was usually observed in PMME‐RP LC system. Online automation of extraction and separation procedures was realized under the control of a program in this study. The developed method was applied to rapid and sensitive monitoring of three β2‐agonist traces in human urine. The LODs (S/N = 3) of the method were found to be 0.05–0.09 ng/mL of β2‐agonists in urine. The recoveries of three β2‐agonists spiked in five different urine samples ranged from 79.8 to 119.8%, with RSDs less than 18.0%.  相似文献   

10.
A novel molecularly imprinted polymer based on magnetic phenyl‐modified multi‐walled carbon nanotubes was synthesized using curcumin as the template molecule, methacrylic acid as the functional monomer and ethylene glycol dimethacrylate as the cross‐linker. The phenyl groups contained in the magnetic imprinted polymers acted as the assisting functional monomer. The magnetic imprinted polymers were characterized by scanning electron microscopy, Fourier‐transform infrared spectroscopy and vibrating sample magnetometry. Adsorption studies demonstrated that the magnetic imprinted polymers possessed excellent selectivity toward curcumin with a maximum capacity of 16.80 mg/g. Combining magnetic extraction and high‐performance liquid chromatography technology, the magnetic imprinted polymer based on magnetic phenyl‐modified multi‐walled carbon nanotubes was applied for the rapid separation and enrichment of curcumin from ginger powder and kiwi fruit root successfully.  相似文献   

11.
Wei X  Qi L  Qiao J  Yao C  Wang F  Chen Y 《Electrophoresis》2010,31(19):3227-3232
A novel and simple method for the separation of major vitamin B analytes, such as thiamine, riboflavin, nicotinamide, vitamin B4, pyridoxine, has been developed by CEC using the monolithic column. It has been found that the baseline separation of the five analytes could be achieved with 5.0 mM phosphate buffer at pH 4.0. Compared with the open-tubular capillary and the bared capillary columns, the poly(butylmethacrylate-co-ethylene glycol dimethacrylate) monolithic capillary could exhibit the best resolution in the analysis. Then the method was validated and the linear calibration ranges were obtained with correlation coefficients more than 0.997. The precision and the recovery were also investigated and showed a good result. Furthermore, the proposed method was successfully applied to assay the concentration of vitamin B analytes and the metabolic situation in human urine samples.  相似文献   

12.
Magnetic molecularly imprinted polymers have been synthesized for the selective preconcentration and trace determination of lamotrigine (LTG) in urine and plasma samples. The magnetic nanoparticles were modified by tetraethyl orthosilicate and 3‐methacryloxypropyl trimethoxysilane before imprinting. The magnetic molecularly imprinted polymers were prepared via surface molecular imprinting technique, using Fe3O4 as a magnetic component, LTG as template molecule, methacrylic acid as a functional monomer, ethylene glycol dimethacrylate as a cross‐linker, and 2,2′‐azobisisobutyronitrile as a radical initiator in methanol/acetonitrile (50:50, v/v) as the porogen. The obtained sorbent was characterized using scanning electron microscopy, Fourier‐transform infrared spectroscopy, X‐ray diffraction, and thermal analysis. Separation of the sorbent from the sample solution was simply achieved by applying an external magnetic field. Determination of the extracted drug was performed by high‐performance liquid chromatography with UV detection. Under the optimum extraction conditions, the method detection limits were 0.7 μg/L (based on S/N of 3) for urine samples and 0.5 μg/L for plasma samples. A linear dynamic range of 1–1000 μg/L was obtained for LTF in plasma and urine samples. Finally, the applicability of the proposed method was evaluated by extraction and determination of LTG in urine and plasma samples.  相似文献   

13.
A novel polymethacrylate‐based monolithic column with covalently bonded zwitterionic functional groups was prepared by in situ copolymerization of N,N‐dimethyl‐N‐methacryloxyethyl N‐(3‐sulfopropyl) ammonium betaine (SPE), pentaerythritol triacrylate (PETA), and vinylsulfonic acid (VS) in a binary porogenic solvent consisting of cyclohexanol and ethylene glycol. This monolith was developed as a separation column for CEC. While SPE functioned as both an electrostatic interaction stationary phase and the polar ligand provider, VS was employed to generate EOF. PETA, which has much more hydrophilicity due to a hydroxyl sub‐layer, was used to replace ethylene dimethacrylate as a cross‐linker. The monolith provided an adequate EOF when VS level was maintained at 0.6% w/w. Different monolithic stationary phases were easily prepared by adjusting the ratio of PETA/SPE in the polymerization solution as well as the composition of the porogenic solvent. The observed RSD were ≤3.6, ≤4.3 and ≤5.6% for the EOF velocity, retention time, and column efficiency, respectively. The column efficiencies greater than 145 000 theoretical plates/m for thiourea and 132 000 theoretical plates/m for charged cytidine were obtained. The poly(SPE‐co‐PETA‐co‐VS) monolith showed good selectivity for neutral and charged polar analytes. It was found that the separation mechanism of charged polar solutes was attributed to a mixed mode of hydrophilic interaction and electrostatic interaction, as well as electrophoresis. No peak tailing was observed for the separation of basic compounds, such as basic nucleic acid bases and nucleoside on the monolith.  相似文献   

14.
A novel prepared method of molecularly imprinted monolithic polymers (MIPs) using 4-hydroxybenzoic acid (4-HBA) as templates for capillary electrochromatography (CEC) was developed. A strategy of high concentration of monomers in the pre-polymerization mixture was used to fulfil the solubility of polar imprinted molecule and reduction of the interference during complex formation. The imprinted polymer capillary monolithic column was synthesized by an in situ therm-initiated copolymerization of methacrylic acid (MAA) and ethylene glycol dimethacrylate with a mixture of toluene-isooctane as a porogenic solvent in the presence of a polar model imprinting molecule, 4-HBA. On the resultant MIP monolithic column, the effect of parameter of CEC on electroosmotic flow (EOF) and the retention of 4-HBA was investigated. The column efficiency of the imprinted molecule, 4-HBA, was 13,000 plates/m. The resolution of isomers of HBA was 5.0 and good molecular recognition was achieved for 4-HBA.  相似文献   

15.
In this study, vinyl phenyl boronic acid modified lauryl methacrylate‐based monolithic column was successfully prepared for cation exchange/hydrophobic interaction monolithic chromatography of small molecules and proteins in nano LC. The polymeric mixture consisted of lauryl methacrylate, vinyl phenyl boronic acid as cation exchanger, ethylene dimethacrylate as cross‐linker, polyethylene glycol and methanol as binary porogenic solvent, and azobisisobutyronitrile as initiator. The resulting monolith showed good permeability and mechanical stability. Different ratios of monomer and porogens were used for optimizing the properties of the column. The monolithic column performance with respect to hydrophobic and cation exchange interactions was assessed by the separation a series of alkyl benzenes and anilines, respectively. cis‐Diol‐containing compounds such as phenols were also utilized to evaluate the retention behaviors of the vinyl phenyl boronic acid modified monolithic column. The monolithic column showed cation exchange interactions in the separation of aniline compounds. Theoretical plate number up to 52 000 plates/m was successfully achieved. The prepared monolith was further applied to the proteins with different acetonitrile content.  相似文献   

16.
光聚合法快速制备甲基丙烯酸酯类毛细管整体柱   总被引:1,自引:0,他引:1  
采用甲基丙烯酸正丁酯(BMA)为功能单体, 乙二醇二甲基丙烯酸酯(EDMA)为交联剂, 正丙醇、1,4-丁二醇和水为致孔剂, Irgacure 1800为引发剂, 在毛细管内采用光引发原位聚合150 s快速制备了有机聚合物整体柱. 分别采用电色谱(CEC)、加压电色谱(p-CEC)和低压色谱(LPLC)模式对所制备的整体柱进行了性能评价, 基线分离了硫脲、甲苯、萘和联苯, 在加压电色谱(p-CEC)模式下硫脲的最低理论塔板高度达到了8.0 μm. 扫描电镜结果表明, 整体材料在毛细管柱中形成并与毛细管内壁结合紧密.  相似文献   

17.
An open tubular molecule imprinted polymer (OT‐MIP) capillary column has been prepared for chiral separation of ofloxacin enantiomers in CEC. The S‐ofloxacin imprinted OT column was fabricated by thermally initiated non‐covalent polymerization procedure inside a pretreated and silanized fused silica capillary. The template molecule was incorporated with methacrylic acid (MAA), ethylene glycol dimethacrylate (EDMA) and 4‐styrenesulfonic acid (4‐SSA) and dissolved in a porogen mixture of ACN/2‐propanol (9:1). The separation efficiency of the 4‐SSA MIP column was found quite better than that of the MIP column without 4‐SSA. It has been demonstrated that our OT‐MIP column can separate ofloxacin enantiomers with excellent chiral separation efficiency after tuning the various chromatographic conditions. The optimized chromatographic eluent was 85:15, v/v%, ACN/60 mM sodium acetate at pH 7. The separation efficiency and selectivity of chiral separation of this study were far better than those obtained by previous methods for chiral separation of R‐ and S‐ofloxacin.  相似文献   

18.
A monolithic molecularly imprinted polymer with specific recognition ability for 4-hydroxybenzoic acid (4-HBA) was prepared by in situ photopolymerization, using methacrylic acid (MAA) as a functional monomer, ethylene glycol dimethacrylate (EDMA) as a cross-linking agent, toluene and isooctane as porogenic solvents and Irgacure 1800 as an initiator. Baseline separation of isomers of hydroxybenzoic acid was achieved in less than 8 min on this monolithic column using 4-HBA as template, but not on the blank polymer. Furthermore, some neutral compounds could also be baseline-separated on the imprinted polymer column in the mode of pressure-driven capillary electrochromatography.  相似文献   

19.
以烯丙基-β-环糊精、甲基丙烯酸缩水甘油酯和乙二醇二甲基丙烯酸酯为功能单体,一步键合制备了环糊精聚合物毛细管整体柱.在电色谱模式下18种氨基酸对映体得到成功分离.研究发现,将修饰的环糊精衍生物作为功能单体制备出的毛细管整体柱对疏水性,含氨基和苯环的手性化合物具有良好的保留行为,并具有良好的稳定性和重现性.新型电色谱柱也被应用于手性药物的分离.  相似文献   

20.
This research highlights the application of highly efficient molecularly imprinted solid‐phase extraction for the preconcentration and analysis of melamine in aquaculture feed samples. Melamine‐imprinted polymers were synthesized employing methacrylic acid and ethylene glycol dimethacrylate as functional monomer and cross‐linker, respectively. The characteristics of obtained polymers were evaluated by scanning electron microscopy, Fourier transform infrared spectroscopy and binding experiments. The imprinted polymers showed an excellent adsorption ability for melamine and were applied as special solid‐phase extraction sorbents for the selective cleanup of melamine. An off‐line molecularly imprinted solid‐phase extraction procedure was developed for the separation and enrichment of melamine from aquaculture feed samples prior to high‐performance liquid chromatography analysis. Optimum molecularly imprinted solid‐phase extraction conditions led to recoveries of the target in spiked feed samples in the range 84.6–96.6% and the relative standard deviation less than 3.38% (n = 3). The aquaculture feed sample was determined, and there was no melamine found. The results showed that the molecularly imprinted solid‐phase extraction protocols permitted the sensitive, uncomplicated and inexpensive separation and pre‐treatment of melamine in aquaculture feed samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号