首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Glucose oxidase (GOD) was encapsulated in chitosan matrix and immobilized on a glassy carbon electrode, achieving direct electron transfer (DET) reaction between GOD and electrode without any nano‐material. On basis of such DET, a novel glucose biosensor was fabricated for direct bioelectrochemical sensing without any electron‐mediator. GOD incorporated in chitosan films gave a pair of stable, well‐defined, and quasireversible cyclic voltammetric peaks at about ?0.284 (Epa) and ?0.338 V (Epc) vs. Ag/AgCl electrode in phosphate buffers. And the peak is located at the potentials characteristic of FAD redox couples of the proteins. The electrochemical parameters, such as midpoint potential (E1/2) and apparent heterogeneous electron‐transfer rate constants (ks) were estimated to ?0.311 V and 1.79 s?1 by voltammetry, respectively. Experimental results indicate that the encapsulated GOD retains its catalytic activity for the oxidation of glucose. Such a GOD encapsulated chitosan based biosensor revealed a relatively rapid response time of less than 2 min, and a sufficient linear detection range for glucose concentration, from 0.60 to 2.80 mmol L?1 with a detection limit of 0.10 mmol L?1 and electrode sensitivity of 0.233 μA mmol?1. The relative standard deviation (RSD) is under 3.2% (n=7) for the determination of practical serum samples. The biologic compounds probably existed in the sample, such as ascorbic acid, uric acid, dopamine, and epinephrine, do not affect the determination of glucose. The proposed method is satisfactory to the determination of human serum samples compared with the routine hexokinase method. Both the unique electrical property and biocompatibility of chitosan enable the construction of a good bio‐sensing platform for achieved DET of GOD and developed the third‐generation glucose biosensors.  相似文献   

2.
《Electroanalysis》2004,16(20):1697-1703
An amperometric glucose biosensor based on multi‐walled carbon nanotube (MWCNT) modified glassy carbon electrode has been developed. MWCNT‐modified glassy carbon electrode was obtained by casting the electrode surface with multi‐walled carbon nanotube materials. Glucose oxidase was co‐immobilized on the MWCNT‐modified glassy carbon surface by electrochemical deposition of poly(o‐phenylenediamine) film. Enhanced catalytic electroreduction behavior of oxygen at MWCNT‐modified electrode surface was observed at a potential of ?0.40 V (vs. Ag|AgCl) in neutral medium. The steady‐state amperometric response to glucose was determined at a selected potential of ?0.30 V by means of the reduction of dissolved oxygen consumed by the enzymatic reaction. Common interferents such as ascorbic acid, 4‐acetamidophenol, and uric acid did not interfere in the glucose determination. The linear range for glucose determination extended to 2.0 mM and the detection limit was estimated to be about 0.03 mM.  相似文献   

3.
CdS修饰玻碳电极电化学发光法检测三聚氰胺   总被引:2,自引:0,他引:2  
本文将CdS纳米棒修饰到玻碳电极上制作了CdS修饰玻碳电极(CdS/GCE)并研究了其在K2S2O8溶液中的电化学发光(ECL)性能.基于三聚氰胺能淬灭CdSK2s2O8电化学发光的性质建立了一种检测三聚氰胺的方法.在最优条件下,体系的ECL强度与三聚氰胺浓度在1.0×10-9~1.0×10-7 mol/L范围内与EC...  相似文献   

4.
A highly sensitive and selective glucose biosensor has been developed based on immobilization of glucose oxidase within mesoporous carbon nanotube–titania–Nafion composite film coated on a platinized glassy carbon electrode. Synergistic electrocatalytic activity of carbon nanotubes and electrodeposited platinum nanoparticles on electrode surface resulted in an efficient reduction of hydrogen peroxide, allowing the sensitive and selective quantitation of glucose by the direct reduction of enzymatically‐liberated hydrogen peroxide at ?0.1 V versus Ag/AgCl (3 M NaCl) without a mediator. The present biosensor responded linearly to glucose in the wide concentration range from 5.0×10?5 to 5.0×10?3 M with a good sensitivity of 154 mA M?1cm?2. Due to the mesoporous nature of CNT–titania–Nafion composite film, the present biosensor exhibited very fast response time within 2 s. In addition, the present biosensor did not show any interference from large excess of ascorbic acid and uric acid.  相似文献   

5.
将合成的立方体纳米氧化亚铜用于修饰玻碳电极,在其上固定葡萄糖氧化酶,构建了高灵敏的安培型葡萄糖生物传感器.采用X射线衍射(X RD)、扫描电镜(SEM)对合成的立方体纳米氧化亚铜及其修饰电极进行了表征.结果表明,合成的纳米氧化亚铜为均匀的立方体形状.采用循环伏安法(CV)、交流阻抗谱(EIS)、差分脉冲伏安法(DPV)及计时电流法(CA)考察了修饰电极的电化学行为.在含0.1 mmol/L葡萄糖的磷酸盐缓冲溶液(pH 7.4)中研究了立方体纳米氧化亚铜修饰电极的循环伏安(CV)响应,实验结果表明,此修饰电极对葡萄糖显示出良好的电催化性能.DPV响应电流与葡萄糖的浓度在5.0×10-6 ~4.0× 10-3mol/L范围内呈良好的线性关系,线性相关系数R2=0.9983,检出限为6.8×10-7 mol/L(S/N=3).CA实验结果表明,尿酸、抗坏血酸、D-果糖对传感器不产生干扰.本传感器具有较好的重现性和稳定性,可用于实际样品中葡萄糖的检测.  相似文献   

6.
聚亚甲基蓝和纳米金修饰玻碳电极的葡萄糖生物传感器   总被引:7,自引:4,他引:7  
用循环伏安法在玻碳电极上电聚合一层稳定的亚甲蓝聚合物膜,研究了这层膜在0.1mol/L磷酸缓冲溶液(pH7.0)中的电化学性质。用纳米金溶胶与聚乙烯醇缩丁醛(PVB)构成复合固酶基质,采用溶胶-凝胶法固定葡萄糖氧化酶(GOD)于亚甲蓝修饰的玻碳电极表面,制成了新型葡萄糖生物传感器。实验发现,加入纳米金后提高了酶电极对葡萄糖的电流响应,所制备的传感器具有响应快、灵敏度高、稳定性好,对葡萄糖的线性响应范围为1×10-6~3×10-3mol/L,检出限为5×10-7mol/L。并具有抗尿酸、抗坏血酸干扰的特点。  相似文献   

7.
A novel and sensitive electrochemiluminescence (ECL) method for ethanol biosensor was developed by co‐immobilizing the enzyme and ECL reagent Ru(bpy)32+ on the poly‐(3,4‐ethylene dioxythiophene) and polystyrene sulfonate functionalized graphene (PEDOT‐PSS‐G) nanocomposite film. Positively charged Ru(bpy)32+ could be immobilized effectively on the electrode surface with the negatively charged PSS and graphene, which provided a stable ECL platform for further modification with the enzyme. Moreover, the introduction of PEDOT and graphene can be acted as a conducting pathway to accelerate the electron transfer due to the high conductivity. Such biosensor combined enzymatic selectivity with the amplification of PEDOT‐PSS‐G performed well with a wide linear range, high sensitivity and good stability. The sensing platform was successfully applied to determine the amounts of alcohol in real samples.  相似文献   

8.
A novel amperometric glucose biosensor was fabricated by in situ incorporating glucose oxidase (GOD) within the sol‐gel silica film on a Prussian blue (PB) modified electrode. The method is simple and controllable, which combined the merits of in situ immobilizing biomolecules in sol‐gel silica film by electrochemical method and the synergic catalysis effects of PB and GOD molecules. Scanning electron microscopy (SEM) showed that the GOD/sol‐gel silica film was homogeneous with a large number of three‐dimensional nanopores, which not only enhanced mass transport, but also maintained the active configuration of the enzyme molecule and prevented the leakage of enzyme, therefore improved the stability and sensitivity of the biosensor. The fabricated biosensor showed fast response time (10 s), high sensitivity (26.6 mA cm?2 M?1), long‐term stability, good suppression of interference, and linear range of 0.01 mM–5.8 mM with a low detection limit of 0.94 μM for the detection of glucose. In addition, the biosensor was successfully applied to determine glucose in human serum samples.  相似文献   

9.
铂纳米颗粒修饰直立碳纳米管电极的葡萄糖生物传感器   总被引:1,自引:0,他引:1  
基于Pt纳米颗粒修饰直立的碳纳米管电极制备了葡萄糖生物传感器.铂纳米颗粒是利用电位脉冲沉积法修饰到直立碳纳米管上的,可以增强电极对酶反应过程当中产生的过氧化氢的催化行为.用扫描电镜和透射电镜观察了直立碳纳米管在修饰Pt纳米颗粒前后的形态.该酶电极对葡萄糖的氧化表现出很好的响应,线性范围为1×10-5~7×10-3mol/L,响应时间小于5s,并且有很好的重现性.  相似文献   

10.
Novel magnetic chitosan‐coated microspheres (MCMSs) were prepared by modifying carbon‐coated iron magnetic nanoparticles with chitosan. An amperometric dihydronicotinamide adenine dinucleotide (NADH) sensor was constructed based on immobilizing MCMS on the surface of a polythionine (PTH) modified glassy carbon electrode (GCE). The fabrication of MCMS/PTH film and its electrocatalytic effect on electrochemical oxidation of NADH were investigated by electrochemical impedance spectroscopy (EIS) and voltammetric methods. It was found that the resulting integrated films of PTH and MCMS exhibit high electrocatalytic response to NADH by significantly reduce its overpotential. The effects of the experimental variables on the amperometric determination of NADH such as solution pH and working potential were investigated for optimum analytical performance. This electrochemical sensor had a fast response to NADH which was less than 10 s. Linear response ranges of 2–10 μM and 10–100 μM and a detection limit of 0.51 μM (S/N=3) were obtained under the optimum conditions. Moreover, the selectivity, stability and reproducibility of this biosensor was evaluated with satisfactory results.  相似文献   

11.
《Electroanalysis》2004,16(21):1806-1813
A highly sensitive amperometric glucose biosensor based on immobilizing glucose oxidase in electropolymerized poly(o‐phenylenediamine) film on glassy carbon electrode coated sequentially with copper and palladium layers has been developed. The steady‐state amperometric response to glucose was determined by means of the oxidation of hydrogen peroxide generated by the enzymatic reaction at a potential of either +0.70 or +0.40 V (vs. Ag|AgCl reference). The deposited copper/palladium layer showed great enhancement in the performance of the enzyme electrode, possibly due to its better electrocatalytic activity for hydrogen peroxide oxidation and large surface area. Effects of the relative loading of palladium, enzyme and polymer on the electrode performance were examined in detail. Sensitivity and detection limit for glucose determinations at +0.70 V were about 7.3 μA/mM and 0.1 μM, respectively. A wide linear range up to 6.0 mM glucose could be achieved. Electrode performance was superior to similar works reported in the literature. The response time was less than 2 s and its lifetime was longer than three months. The permeable polyphenylenediamine film also offered good anti‐interference ability to ascorbic acid, uric acid and acetaminophen, especially when a detection potential of +0.40 V was employed.  相似文献   

12.
Nanohybrids of chemically modified graphene (CMG) and ionic liquid (IL) were prepared by sonication to modify the electrode. The modified CMG‐IL electrodes showed a higher current and smaller peak‐to‐peak potential separation than a bare electrode due to the promoted electron transfer rate. Furthermore, the glucose oxidase (GOx) immobilized on the modified electrode displayed direct electron transfer rate and symmetrical redox potentials with a linear relationship at different scan rates. The fabricated GOx/CMG‐IL electrodes were developed selective glucose biosensor with respect to a sensitivity of 0.64 μA mM?1, detection limit of 0.376 mM, and response time of <5 s.  相似文献   

13.
以中性红为电子媒介体,电聚合于Nafion修饰的玻碳电极表面,以戊二醛作交联剂固定葡萄糖氧化酶,最后覆盖一层Nafion膜防止酶流失,构建一种新型葡萄糖生物传感器.详细探讨了传感器的电化学性能及对葡萄糖的最佳响应条件.结果表明,30℃时,传感器在pH 7.0的PBS中对葡萄糖的线性响应范围为1.0×10-5~5.0×10-3mol.L-1.该传感器制作简单、性能优良,有潜在应用前景.  相似文献   

14.
In the present work, a simple and economic analytical method based on attapulgite/nafion coated glassy carbon electrode (AT/Naf/GCE) has been developped for the electrochemical determination of caffeine. Prior to its use, the ionic exchange properties and conductivity of AT/Naf/GCE were studied by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Caffeine gave an irreversible oxidation peak around +1.41 V (vs Ag/AgCl reference electrode) in 0.1 M H2SO4 at pH 1.5. The peak current varied linearly with the square root of the scan rate, showing that the transfer process is controlled by diffusion. The heterogeneous rate constant, the transfer coefficient and the number of electrons involved were calculated. Upon optimization of key analytical parameters involved in the electroanalysis of caffeine by DPV, the recorded oxidation peak current varied linearly with caffeine concentration in the range from 0.1 to 4 μm, leading to a detection limit of 4.57×10?8 M (S/N=3). The developed electrode exhibited good stability and was easily regenerated. The effect of some important potential interfering compounds (ascorbic acid, dopamine, uric acid, sulphite ions and glucose) on the signal of caffeine was also examined. The obtained electrode was successfully employed in the determination of caffeine content in a commercial drug.  相似文献   

15.
A carbon paste electrode (CPE) modified with Nafion, Graphene oxide and zeolite has been prepared and characterized, and the resulting Nafion/Graphene oxide/Zeolite modified carbon paste electrode (N/G/Z/MCPE) has been applied to the electrochemical detection of Moxifloxacin hydrochloride (MOXI). It exhibited a good electrocatalytic activity in phosphate buffer (optimum at pH 7.4), as pointed out by cyclic voltammetry (CV), and N/G/Z/MCPE can be exploited for MOXI detection by chronoamperometry, electrochemical impedance spectroscopy and differential pulse voltammetry. This latter was the most sensitive one and gave rise to a linear calibration curve in the 0.04 to 250 μM concentration range, with limits of detection and qualification estimated at 1.0 nM and 3.3 nM, respectively. Contrary to previous electrochemical sensors for MOXI (e. g., CPE modified with metal nanoparticles), this new sensor can be used for multiple successive analyses without needing to refresh its surface.  相似文献   

16.
采用化学气相沉积法生长多晶石墨烯(Graphene, G),转移至聚对苯二甲酸乙二醇酯(PET)薄膜表面,通过控制金溶胶蒸发速率,在多晶石墨烯表面组装均匀分布的亚单层金纳米粒子(AuNPs);然后修饰巯基乙酸,通过共价交联反应将葡萄糖氧化酶固定于AuNPs表面,构建基于PET膜的石墨烯/金纳米粒子/葡萄糖氧化酶(G/AuNPs/GOD)柔性电极.此电极在工作电位0.6 V(vs.SCE电极)、pH 7.0磷酸盐缓冲溶液、室温25℃条件下,差分脉冲伏安法响应电流与被测葡萄糖浓度在0.05~10.55 mmol/L范围内呈线性关系,线性方程为I(108A)=0.2629 C(mmol/L)+1.4149,线性相关系数 r=0.9955,检出限1 μmol/L (3σ). G/AuNPs/GOD柔性电极的制备可为特定环境和可穿戴设备的葡萄糖检测提供了新的途径和方法,拓展了葡萄糖检测的应用范围.  相似文献   

17.
以Nafion修饰的镀铂玻碳电极为基底的半乳糖传感器的制备   总被引:3,自引:0,他引:3  
纪学锋  章咏华 《分析化学》1993,21(5):519-522
在镀铂的玻碳电极表面,修饰一层全氟代磺酸酯(Nafion)膜,制成基底电极。用化学交联法将半乳糖氧化酶(GAD)固定在基底电极表面,即制成半乳糖传感器。和光亮铂相比,镀铂电极对过氧化氢有更高的响应,而Nafion膜可以消除抗坏血酸,尿酸等电活性物质对测定的影响,提高了酶电极测定的选择性。D-半乳糖测定的线性范围为0.25~4.25 mmol/L,响应时间小于30s。电极连续使用300次,没有明显的电流变化。该电极具有快速、准确,选择性高的特点。  相似文献   

18.
陈慧娟  朱建君  余萌 《分析化学》2013,41(8):1243-1248
采用滴涂法和电沉积法制备了石墨烯/纳米氧化锌复合膜修饰玻碳电极,再将葡萄糖氧化酶固定在修饰电极表面制成了电化学生物传感器,用于葡萄糖的灵敏测定。用循环伏安法在-0.7~-0.1 V范围内研究了葡萄糖氧化酶在修饰电极上的直接电化学行为。结果表明,石墨烯/纳米氧化锌复合膜能很好地保持葡萄糖氧化酶的生物活性,并显著促进了其电化学过程。在0.1 mol/L磷酸盐缓冲溶液(pH 7.0)中,固定在修饰电极上的葡萄糖氧化酶呈现出一对近乎可逆的氧化还原峰,并且对葡萄糖的氧化具有良好的催化作用。葡萄糖氧化酶在修饰电极上的电子转移常数ks为1.42 s-1,修饰电极对葡萄糖催化的米氏常数Kampp为14.2μmol/L。线性范围为2.5×10-6~1.5×10-3mol/L,检出限为2.4×10-7mol/L(S/N=3)。此修饰电极具有良好的导电性能、稳定性和重现性,可用于实际样品的分析测定。  相似文献   

19.
A simple and controllable electrodeposition approach was proposed for one‐step construction of glucose biosensors by in situ co‐deposition of ferrocene‐branched chitosan derivatives (CS‐Fc), multiwalled carbon nanotubes (MWNTs), and glucose oxidase (GOD) onto electrode surface. The formation of CS‐Fc could not only effectively prevent the leakage of Fc and retain its electrochemical activity, but also provide a biocompatible microenvironment for retaining the native activity of the immobilized biomolecules. Further entrapment of MWNTs into the CS matrix improved electronic conductivity of the biocomposite significantly. The facile procedure of immobilizing GOD and the promising feature of biocomposite will offer a versatile platform to fabricate biosensors and bioelectronic devices.  相似文献   

20.
A new electrochemical biosensor was constructed by immobilization of hemoglobin (Hb) on a DNA modified carbon ionic liquid electrode (CILE), which was prepared by using 1‐ethyl‐3‐methylimidazolium tetrafluoroborate (EMIMBF4) as the modifier. UV‐vis absorption spectroscopic result indicated that Hb remained its native conformation in the composite film. The fabricated Nafion/Hb/DNA/CILE was characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). A pair of well‐defined redox peaks was obtained on the modified electrode, indicated that the Nafion and DNA composite film provided an excellent biocompatible microenvironment for keeping the native structure of Hb and promoting the direct electron transfer rate of Hb with the basal electrode. The electrochemical parameters of Hb in the composite film were further calculated with the results of the charge transfer coefficient (α) and the apparent heterogeneous electron transfer rate constant (ks) as 0.41 and 0.31 s?1. The proposed electrochemical biosensor showed good electrocatalytic response to the reduction of trichloroacetic acid (TCA), H2O2, NO and the apparent Michaelis–Menten constant (KMapp) for the electrocatalytic reaction was calculated, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号