1.
AgSIE was used for the direct analysis of folic acid (FA), with a detection limit and lower level of quantitation of 6.8×10?10 mol L?1 and 2.3×10?8 mol L?1. The analysis in fresh and processed fruits was done without any sample pretreatment. In strawberry and acerola juices, FA concentration level values were below the method detection limit. FA was detectable in peach (77.7±0.4 µg L?1 and 64.4±0.5 µg L?1), Persian lime (45.4±0.7 µg L?1), pineapple Hawaii (66.2±0.4 µg L?1), pear pineapple (35.3±0.6 µg L?1), cashew (54.4±0.5 µg L?1), passion fruit (73.2±0.3 µg L?1), and apple (84.4±0.5 µg L?1).  相似文献   

2.
The voltammetric behavior of two genotoxic nitro compounds (4‐nitrophenol and 5‐nitrobenzimidazole) has been investigated using direct current voltammetry (DCV) and differential pulse voltammetry (DPV) at a polished silver solid amalgam electrode (p‐AgSAE), a mercury meniscus modified silver solid amalgam electrode (m‐AgSAE), and a mercury film modified silver solid amalgam electrode (MF‐AgSAE). The optimum conditions have been evaluated for their determination in Britton‐Robinson buffer solutions. The limit of quantification (LQ) for 5‐nitrobenzimidazole at p‐AgSAE was 0.77 µmol L?1 (DCV) and 0.47 µmol L?1 (DPV), at m‐AgSAE it was 0.32 µmol L?1 (DCV) and 0.16 µmol L?1 (DPV), and at MF‐AgSAE it was 0.97 µmol L?1 (DCV) and 0.70 µmol L?1 (DPV). For 4‐nitrophenol at p‐AgSAE, LQ was 0.37 µmol L?1 (DCV) and 0.32 µmol L?1 (DPV), at m‐AgSAE it was 0.14 µmol L?1 (DCV) and 0.1 µmol L?1 (DPV), and at MF‐AgSAE, it was 0.87 µmol L?1 (DCV) and 0.37 µmol L?1 (DPV). Thorough comparative studies have shown that m‐AgSAE is the best sensor for voltammetric determination of the two model genotoxic compounds because it gives the lowest LQ, is easier to prepare, and its surface can be easily renewed both chemically (by new amalgamation) and/or electrochemically (by imposition of cleaning pulses). The practical applicability of the newly developed methods was verified on model samples of drinking water.  相似文献   

3.
The electrochemical oxidation of ibuprofen at a boron‐doped diamond electrode (BDDE) and its voltammetric determination is reported for the first time. A well‐defined oxidation peak was observed at around 1.6 V in 0.1 mol L?1 H2SO4 solution with 10 % (v/v) ethanol at the BDDE surface activated by either cathodic or anodic pretreatments. A differential‐pulse voltammetric method for the determination of ibuprofen in pharmaceutical formulations was optimized with a detection limit of 5 µmol L?1 and compared with the British Pharmacopeia method.  相似文献   

4.
Conventional (CPE) and miniaturized (m‐CPE) carbon paste electrodes consisting of a carbon paste filled capillary were used for differential pulse voltammetric determination of chlortoluron in samples of river water and soil, in the latter case after the extraction by methanol. Britton‐Robinson buffer pH 3 with low content of methanol was found to be optimal for the determination. The achieved determination limits were 2.8 µmol L?1 and 0.34 µmol L?1 in river water, and 3.1 and 4.3 µg g?1 in soil, using CPE and m‐CPE, respectively.  相似文献   

5.
Mesoporous carbon ceramic SiO2/50 wt % C (SBET=170 m2 g?1), where C is graphite, were prepared by the sol‐gel method. The materials were characterized using N2 sorption isotherms, scanning electron microscopy, and conductivity measurements. The matrix was used as support for the in situ immobilization of Mn(II) phthalocyanine (MnPc) on their surface. XPS was used to determine the Mn/Si atomic ratios of the MnPc‐modified materials. Pressed disk electrodes were prepared with the MnPc‐modified matrix, and tested as an electrochemical sensor for nitrite oxidation. The linear response range, sensitivity, detection limit and quantification limit were 0.79–15.74 µmol L?1, 17.31 µA L µmol?1, 0.02 µmol L?1 and 0.79 µmol L?1, respectively, obtained using cyclic voltammetry. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation was 1.7 % for 10 measurements of a solution of 12.63 µmol L?1 nitrite. The sensor employed to determine nitrite in sausage meat, river and lake water samples showed to be a promising tool for this purpose.  相似文献   

6.
A self-assembled sensor based on a boron-doped diamond was investigated as a sensitive tool for voltammetric analysis of a member of a pyridine herbicide family - picloram. A cyclic voltammetry and a differential pulse voltammetry were applied for investigation of the voltammetric behaviour and quantification of this herbicide. Picloram yielded one well-developed irreversible oxidation signal at a very positive potential about +1.5 V vs. Ag/AgCl/3 mol L?1 KCl electrode in an acidic medium and 1 mol L?1 H2SO4 was chosen as a suitable supporting electrolyte. Operating parameters of differential pulse voltammetry were optimized and the proposed voltammetric method provided a high repeatability (a relative standard deviation of 20 repeated measurements at a concentration level of picloram of 50 µmol L?1 equaled to 2.58%), a linear concentration range from 2.5 to 90.9 µmol L?1 and a low limit of detection (LD = 1.64 µmol L?1). Practical usefulness of the ‘environmentally-green’ electrochemical sensor was verified by an analysis of spiked water samples with satisfactory recoveries.  相似文献   

7.
《Analytical letters》2012,45(6):881-897
Abstract

The preparation and electrochemical characterization of a carbon composite electrode modified with copper(II)-resin as well as its behavior toward rutin were investigated using cyclic and linear sweep voltammetry. The best voltammetric response was observed for a composite composition of 20% (m/m) copper(II)-resin, 0.10 mol L?1 KNO3/10?6 mol L?1 HNO3 solution (pH 6.0) as the supporting electrolyte, and a scan rate of 50 mVs?1. A linear voltammetric response for rutin was obtained in the concentration range from 9.90 × 10?7 to 8.07 × 10?6 mol L?1, with a detection limit of 2.65 × 10?8 mol L?1. The proposed electrode was useful for the quality control and routine analysis of rutin in pharmaceutical formulations.  相似文献   

8.
This work presents the electrochemical oxidation of the antioxidant astaxanthin on a glassy‐carbon electrode (GCE) and its amperometric determination in salmon samples using a batch‐injection analysis (BIA) system. The proposed BIA method consisted of 80‐µL a fast microliter injection of sample at 193 µL s?1 on the GCE immersed in the electrolyte, a mixture of acetone, dichloromethane, and water (80 : 10 : 10 v/v), containing 0.1 mol L?1 HClO4. Advantages include high precision (RSD of 2.4 %), sample throughput of 240 h?1, and low detection limit (0.3 µmol L?1 that corresponds to 0.1 µg g?1) for the analysis of acetone extracts of salmon samples. Recovery values between 83 and 97 % attested the accuracy of the method.  相似文献   

9.
A simple, low-cost and sensitive electroanalytical method was developed for the simultaneous determination of p-nitrophenol and o-nitrophenol isomers in water samples at a glassy carbon electrode (CGE) in the presence of cationic surfactant. The electrochemical behavior of p-nitrophenol and o-nitrophenol was studied by cyclic voltammetry (CV) in 0.1?mol L?1 acetate/acetic acid buffer (pH 3.70) in the presence and absence of cetylpyridinium bromide. The resolution of overlapped cathodic peaks potentials (Epc) of isomers was successfully improved in the presence of 100.0?µmol L?1 cetylpyridinium bromide, thus making this approach ideal for the simultaneous determination of isomers. Under the optimized conditions in 0.05?mol L?1 HEPES buffer at pH 7.0 using differential pulse voltammetry (DPV) at a scan rate of 45?mV s?1, pulse amplitude of 220?mV and modulation time of 10?ms, limits of detection 0.59?µmol L?1 for p-nitrophenol and 1.14?µmol L?1 for o-nitrophenol were obtained with linear ranges from 2.0 to 60.0?µmol L?1 and 3.0 to 60.0?µmol L?1, respectively. The intraday precision was assessed as relative standard deviation (%) for 20.0 and 40.0?µmol L?1 concentrations were 4.30% and 2.41% for p-nitrophenol and 4.87% and 2.20% for o-nitrophenol, respectively. The developed method was applied for the determination of the isomers in lake water samples. The accuracy was attested by comparison with high-performance liquid chromatography with diode array detection (HPLC-DAD) as a reference analytical technique. Recovery values ranging from 90.3% to 111.8% also attested to the accuracy of method for analysis of real samples.  相似文献   

10.
A glassy carbon electrode coated the film of 4‐tert‐butyl‐1‐(ethoxycarbonylmethoxy)thiacalix[4]arene is designed for the determination of trace amounts of Hg2+. Compared with bare glassy carbon electrode, the modified electrode can improve the measuring sensitivity of Hg2+. Under the optimum experimental condition, the modified electrode in 0.1 mol L?1 H2SO4 + 0.01 mol L?1 KCl solution shows a linear voltammetric response in the range of 8.0 × 10?9 ~ 3.0 × 10?6 mol L?1 with detection limit 5.0 × 10?9 mol L?1 for Hg2+. The high sensitivity, selectivity, and stability of modified electrode also prove its practical application for a simple, rapid and economical determination of Hg2+ in water samples.  相似文献   

11.
This work reports the application of screen‐printed electrodes bulk‐modified with bismuth precursors to the voltammetric determination of 2‐nitrophenol (2‐NP), 4‐nitrophenol (4‐NP) and 2,4‐dinitrophenol (2,4‐DNP) in water samples. A bismuth film was formed at the electrode surface via in situ reduction of the precursor compound contained in the electrode matrix by cathodic polarization at ?1.20 V. The formation of bismuth layer at the precursor‐modified electrodes was assessed by cyclic voltammetric (CV) at different pH values and by optical techniques. The target nitrophenols were voltammetrically determined by recording their reduction peaks in the differential pulse (DP) mode. The composition and content of the precursor compounds in the printed ink and the effect of the pH of the supporting electrolyte on the DP reduction currents of the 3 target nitrophenols were studied. The limits of quantification (LOQs) in three water matrices (distilled water, tap water and surface water) were in the range 1.1–2.2 µmol L?1. Using a simple solid‐phase extraction (SPE) procedure with Lichrolut EN cartridges and elution with methanol, a preconcentration factor of 100 was achieved; the LOQs were 0.021, 0.027 and 0.025 µmol L?1 for 2‐NP, 4‐NP and 2,4‐DNP, respectively. The recoveries of samples spiked with the 3 target nitrophenols at two concentration levels (0.04 and 0.1 µmol L?1) were always >87 %.  相似文献   

12.
This study is aimed to develop an electroanalytical methodology using a boron‐doped diamond electrode (BDD) associated with experimental design in order to determine simultaneously and selectively carbendazin (CBZ) and fenamiphos (FNP) pesticides. In previous studies oxidation peaks were observed at 1.10 V (CBZ) and 1.20 V (FNP), respectively, with characteristics of irreversible processes controlled by diffusion of species (in pH 2.0 (CBZ) and pH 3.5 (FNP)) using a BR buffer 0.1 mol L?1 as support electrolyte. The differences between the potentials for both pesticides, (about 100 mV) indicate the possibility of selective determination of FNP and CBZ. However, employing an equimolar mixture of analytes, the peaks overlap to form a single oxidation peak. Thus, we used a 34 full factorial design with four parameters to be analyzed in three levels, in order to obtain the optimized parameters for the separation of the peaks. The best separation conditions were pH 5.0, square wave frequency of 300 s?1, pulse amplitude of 10 mV and scan increment of 2 mV. These parameters were used to obtain the calibration curves of CBZ and FNP. For CBZ the analytical curve was obtained in the concentration range of 4.95×10?6 to 6.90×10?5 mol L?1 with good sensitivity and linearity (0.175 A/mol L?1 and 0.999, respectively). The limits of detection (LOD) and quantification (LOQ) were 1.6×10?6 mol L?1 and 5.5×10?6 mol L?1, respectively. For FNP the linear concentration interval was 4.95×10?6 to 3.67×10?5 mol L?1, with a sensitivity of 0,207 A/mol L?1 and linearity of 0.996. The LOD and LOQ were 4.1×10?6 mol L?1 and 13.7×10?6 mol L?1, respectively. Using these experimental conditions it was possible to separate the oxidation peaks of CBZ (Ep=1.08 V) and FNP (Ep=1.23 V). The electroanlytical method was applied in lemon juice samples. The recovery values were 110.0 % and 92.5 % for CBZ and FNP, respectively. The results showed that the developed method is suitable for application in foodstuff samples.  相似文献   

13.
A new voltammetric procedure for the simultaneous determination of dopamine (DA) and paracetamol (PA) using boron doped diamond electrode modified with Nafion and lead films (PbF/Nafion/BDDE) was investigated. The use of this electrode resolved the overlapped voltammetric waves of DA and PA into well‐defined peaks with peak to peak separation of about 320 mV. Under the optimized experimental conditions in differential pulse voltammetric technique, DA and PA gave a linear response over the ranges 2.0×10?7–1.0×10?4 mol L?1*(R2=0.9996) and 5.0×10?7–1.0×10?3 mol L?1 (R2=0.9979), respectively. The detection limits were found to be 5.4×10?8 mol L?1 for DA and 1.4×10?7 mol L?1 for PA. They are lower, comparable or in some cases a little bit higher than those obtained using other electrochemical sensors. However, the proposed procedure of the sensor preparation is much simpler than procedures described in the literature with a lower detection limit. The proposed procedure was successfully applied to the determination of PA in some commercial pharmaceuticals as well as to the simultaneous determination of DA and PA in human urine, whole blood and serum samples directly without any separation steps.  相似文献   

14.
《Analytical letters》2012,45(5):750-762
A simple, low cost sensor was developed for the voltammetric determination of hydrogen peroxide in mouthwash and dental whitening gel based on multi-walled carbon nanotubes incorporated with hemin. The sensor showed electrocatalytic activity toward the reduction of hydrogen peroxide in 0.05 mol L?1 Tris-HCl buffer solution (pH 7.0) using cyclic voltammetry. The optimum composition of paste was 20:10:70% (m/m/m) (multi-walled carbon nanotubes:hemin:mineral oil). A linear plot of the square root of scan rate vs. cathodic peak current showed that reduction of hydrogen peroxide is diffusion controlled. Using linear sweep voltammetry, the analytical curve ranged from 0.2 up to 1.4 mmol L?1 (r = 0.9996) with a sensitivity of 3.62 × 10?2 mA mol?1 L. The limits of detection and quantification were found to be 12.5 µmol L?1 and 41.7 µmol L?1, respectively. The developed method was applied for hydrogen peroxide determination in dental formulations. The results were compared with a volumetric method as a reference technique. No significant differences at the 95% level (paired student t test) were observed, thus demonstrating the accuracy of the sensor for the analysis of real samples.  相似文献   

15.
《Electroanalysis》2003,15(7):601-607
A voltammetric method for the determination of the antibiotic oxytetracycline (OTC) in food samples is reported. Carbon fiber microelectrodes (CFMEs), which allow voltammetric measurements to be performed in a small volume (1 mL) of the analyte extract from the samples, are employed. Repeatable electroanalytical responses were obtained with no need of applying cleaning treatments to the CFME. Under the optimized square‐wave conditions, a linear calibration plot for OTC was obtained in the 1.0×10?6–1.0×10?4 mol L?1 range, with a detection limit of 2.9×10?7 mol L?1 (150 ng mL?1) OTC. The determination of OTC by a flow‐injection method with amperometric detection using a homemade flow cell specially designed to work with CFMEs, was also evaluated using pure acetonitrile as the carrier. The SW voltammetric method was applied to the determination of OTC in spiked milk and eggs samples, at 100 ng mL?1 and 200 ng g?1 levels, respectively. The procedure involved the extraction of the analyte in ethyl acetate, evaporation of the solvent and reconstitution of the residue in acetonitrile ?5.0×10?4 mol L?1 tetrabutylammonium perchlorate medium. Recoveries of 96±8 and 91±8% were obtained for milk and eggs, respectively, by applying the standard additions method.  相似文献   

16.
A simple and fast voltammetric method based on a new electrode composed of carbon paste electrode/bifunctional hybrid ion imprinted polymer (CPE/IIP) was developed for the quantification of Cd2+ in water samples. The voltammetric measurements by Differential Pulse Voltammetry were performed by using CPE containing 11.0 mg of IIP under phosphate buffer solution at concentration 0.1 mol L?1 and pH 6.5. The electrochemical method was carried out by Cd2+ preconcentration at ?1.2 V during 210 s, followed by anodic stripping. The performance of IIP towards Cd2+ determination was evaluated by comparison to non-imprinted polymer, whose detectability of IIP was much higher (45%). The sensitivity of the sensor was found to be 0.0105 µA/µg L?1. The limits of detection and limits of quantification were found to be 4.95 μg L?1 and 16.4 μg L?1, respectively. The developed method was successfully applied to Cd2+ determination in mineral, tap and lake water samples, whose results are in agreement with thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) used as reference analytical technique. According to achieved results, the developed method can be used for routine analysis of quality control of water samples from different sources.  相似文献   

17.
《Electroanalysis》2003,15(9):821-826
A sensitive and selective on‐line voltammetric procedure for determination of traces of Se(IV) is presented. The pulsed potential accumulation was proposed for minimization of interferences of surface active substances and foreign ions. The calibration plot was linear from 1×10?9 mol L?1 to 4×10?8 mol L?1 for accumulation time of 180 s. The relative standard deviation was 6.1% (n=5) for a Se(IV) concentration of 1×10?8 mol L?1. The detection limit estimated from (3 σ) for an accumulation time of 180 s was about 4×10?10 mol L?1. The validation of the procedure proposed was made by a recovery tests for tap and river water samples.  相似文献   

18.
The present work describes the development of a selective and sensitive voltammetric sensor for simultaneous determination of catechol (CC) and hydroquinone (HQ), based on a glassy carbon (GC) electrode modified with manganese phthalocyanine azo‐macrocycle (MnPc) adsorbed on multiwalled carbon nanotubes (MWCNT). Scanning electron microscopy and scanning electrochemical microscopy were used to characterize the composite material (MnPc/MWCNT) on the glassy carbon electrode surface. The modified electrode showed excellent electrochemical activity towards the simultaneous oxidation and reduction of CC and HQ. On the MnPc/MWCNT/GC electrode, both CC and HQ can generate a pair of quasi‐reversible and well‐defined redox peaks. Under optimized experimental and operational conditions, the cathodic peak currents were linear over the range 1–600 µmol L?1 for both CC and HQ, with limits of detection of 0.095 and 0.041 µmol L?1, respectively. The anodic peak currents were also linear over the range 1–600 µmol L?1 for both CC and HQ, with limits of detection of 0.096 and 0.048 µmol L?1, respectively. The proposed method was effectively applied for the simultaneous detection of hydroquinone and catechol in water samples and the results were in agreement with those obtained by a comparative method described in the literature.  相似文献   

19.
《Analytical letters》2012,45(9):1571-1578
Abstract

The present paper describes the evaluation and application of internal standard for the determination of copper in fruit juices, employing Fast Sequential Flame Atomic Absorption Spectrometry (FS FAAS). The internal standards tested were indium, cobalt, and nickel using correlation graphs. However, indium was used, considering the composition of the samples. After this step, copper was determined in fruit juices using indium as internal standard. This method allows the determination of copper with a limit of quantification of 0.011 mg L?1. The fruit juice samples selected for analysis were of grape, orange, pineapple, peach, cashew, and strawberry. The contents of copper in these samples varied from 0.02 to 0.42 mg L?1. The analytical results were compared with the results obtained by analysis of these samples after complete mineralization using acid digestion and determination employing FS FAAS. The statistical comparison by a t-test (95% confidence level) showed no significant difference between the results. The relative standard deviations (RSD) with and without the use of the internal standard for a copper solution containing 0.4 mg L?1 were of 0.62 and 1.94%, respectively. The use of indium as internal standard provided more accurate analytical results, as well as better analytical performance for the determination of copper in juice samples.  相似文献   

20.
《Electroanalysis》2006,18(12):1223-1226
A sensitive catalytic adsorptive stripping voltammetric procedure for determination of traces of total chromium in environmental samples is reported. The method is based on the preconcentration of a Cr(III)? H2DTPA complex by adsorption at the HMDE from an acetate buffer solution at the potential ?1.0 V vs. Ag/AgCl. Total chromium was determined as Cr(III) after reduction of Cr(VI) to Cr(III) by NaHSO3. In order to stabilize the signal of Cr(III) the measurements were performed at 5 °C. The calibration graph for chromium for an accumulation time of 60 s was linear in the range from 5×10?10 to 5×10?8 mol L?1. The relative standard deviation for a chromium concentration of 1×10?8 mol L?1 was 3.9% (n=5). The detection limit for accumulation time of 60 s was about 8×10?11 mol L?1. The validation of the procedure was performed by the analysis of the certified reference materials.  相似文献   