首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(4):823-833
Abstract

A simple, sensitive, and specific spectrophotometric method for the measurement of nitrite in water has been developed and optimum reaction conditions along with other analytical parameters have been evaluated. The azo dye, 4‐(1‐methyl‐1‐mesitylcylobutane‐3‐yl)‐2‐(p‐N,N‐dimethylazobenzene)‐1,3‐thiazole was synthesized with the reaction of 4‐(1‐methyl‐1‐mesitylcylobutane‐3‐yl)‐2‐aminothiazole and N,N‐dimethyl aniline in acidic medium. Obtained azo dye has been characterized by infrared (IR), 1H nuclear magnetic resonance (NMR), and microanalysis methods. The dye shows an absorption maximum at 482 nm. The method is optimized for acid concentration, pH, amount of reagents required, time, and interfering species. All the determinations were carried out at this wavelength throughout the work. At an analytical wavelength of 482 nm, Beer's law is obeyed over the concentration range 0.05 to 2.00 µg nitrite per mL analyte. The molar absorptivity, Sandell's sensitivity, and relative standard deviation are 2.03×104 L mol?1 cm?1±251.3 (95%), 2.28×10?3 µg cm?2, and 2.74% (n=10), respectively. The detection limit of the method is 0.012 µg ml?1 of nitrite ion. The method was succesfully applied to the determination of nitrite in tap water and lake water.  相似文献   

2.
Mesoporous carbon ceramic SiO2/50 wt % C (SBET=170 m2 g?1), where C is graphite, were prepared by the sol‐gel method. The materials were characterized using N2 sorption isotherms, scanning electron microscopy, and conductivity measurements. The matrix was used as support for the in situ immobilization of Mn(II) phthalocyanine (MnPc) on their surface. XPS was used to determine the Mn/Si atomic ratios of the MnPc‐modified materials. Pressed disk electrodes were prepared with the MnPc‐modified matrix, and tested as an electrochemical sensor for nitrite oxidation. The linear response range, sensitivity, detection limit and quantification limit were 0.79–15.74 µmol L?1, 17.31 µA L µmol?1, 0.02 µmol L?1 and 0.79 µmol L?1, respectively, obtained using cyclic voltammetry. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation was 1.7 % for 10 measurements of a solution of 12.63 µmol L?1 nitrite. The sensor employed to determine nitrite in sausage meat, river and lake water samples showed to be a promising tool for this purpose.  相似文献   

3.
Yudum Tepeli  Ulku Anik 《Electroanalysis》2016,28(12):3048-3054
Three different Graphene‐Metallic (Graphene‐Me) nanocomposites – Graphene‐Silver (Graphene‐Ag), Graphene‐Gold (Graphene‐Au) and Graphene‐Platinum (Graphene‐Pt) nanocomposites – were prepared and characterized. The electrochemical performances of these nanocomposites were tested by incorporating them with glassy carbon paste electrode (GCPE) and used them in biofuel cells (BFC) and as amperometric xanthine biosensor transducers. Present work contains the first application of Graphene‐Au and Graphene‐Ag nanocomposite in BFCs and also first application of these Graphene‐Me nanocomposites in xanthine biosensors. Considering BFC, power and current densities were calculated as 2.03 µW cm?2 and 167.46 µA cm?2 for the plain BFC, 3.39 µW cm?2 and 182.53 µA cm?2 for Graphene‐Ag, 4.43 µW cm?2 and 230.15 µA cm?2 for Grapehene‐Au and 6.23 µW cm?2 and 295.23 µA cm?2 for Graphene‐Pt nanocomposite included BFCs respectively. For the amperometric xanthine biosensor linear ranges were obtained in the concentration range between 5 µM and 50 µM with the RSD (n=3 for 30 µM xanthine) value of 4.28 % for plain xanthine biosensor, 3 µM and 50 µM with the RSD (n=3 for 30 µM xanthine) value of 9.37 % for Graphene‐Ag, 5 µM to 20 µM with the RSD (n=3 for 5 µM xanthine) value of 9.00 % and 30 µM to 70 µM with the RSD (n=3 for 30 µM xanthine) value of 8.80 % for Grapehene‐Au and 1 µM and 70 with the the RSD (n=3 for 30 µM xanthine) value of 2.59 % for Grapehene‐Pt based xanthine biosensors respectively.  相似文献   

4.
A highly sensitive spectrophotometric method for the determination of nitrite in water and soil has been developed. The reaction of nitrite with acidified potassium iodide to liberate iodine which oxidizes leuco‐crystal violet (LCV) to form crystal violet having absorption maxima at 590 nm forms the bases of this method. In aqueous medium the system obeys Beer's law in the range of 0.1 to 1.0 μg per 25 mL (0.004–0.04 ppm), while in an extractive system the range is 0.025–0.25 μg in 100 mL (0.00025–0.0025 ppm). The molar absorptivity and Sandell's sensitivity were found to be 1.54 × 106 1 mol?1 cm?1 and 44 pg cm?2, respectively.  相似文献   

5.
Direct electron transfer of immobilized copper, zinc‐superoxide dismutase (SOD) onto electrodeposited nickel‐oxide (NiOx) nanoparticle modified glassy carbon (GC) electrode displays a well defined redox process with formal potential of ?0.03 V in pH 7.4. Cyclic voltammetry was used for deposition of (NiOx) nanoparticles and immobilization of SOD onto GC electrode. The surface coverage (Γ) and heterogeneous electron transfer rate constant (ks) of immobilized SOD are 1.75×10?11 mol cm?2 and 7.5±0.5 s?1, respectively. The biosensor shows a fast amperometric response (3 s) toward superoxide at a wide concentration range from 10 µM to 0.25 mM with sensitivity of 13.40 nA µM?1 cm?2 and 12.40 nA µM?1 cm?2, detection limit of 2.66 and 3.1 µM based on anodically and cathodically detection. This biosensor exhibits excellent stability, reproducibility and long life time.  相似文献   

6.
We report a simple approach to the production of carbon fiber‐based amperometric microbiosensors for selective detection of hydrogen peroxide (H2O2), which was achieved by electrometallization of carbon fiber microelectrodes (CFMs) by electrodeposition of Pt nanoparticles. The Pt‐carbon hybrid sensing interface provided a sensitivity of 7711±587 μA ? mM?1 ? cm?2, a detection limit of 0.53±0.16 μM (S/N=3), a linear range of 0.8 μM–8.6 mM, and a response time of <2 sec. The morphologies of the Pt nanoparticle‐modified CFMs were characterized by scanning electron microscopy. To achieve selectivity, permseletive layers, polyphenylenediamine (PPD) and Nafion, were deposited resulting in exclusion of the anionic and cationic interferents, ascorbic acid and dopamine, respectively, at their physiologically relevant concentrations. The resultant sensors displayed a sensitivity to hydrogen peroxide of 1381±72 μA ? mM?1 ? cm?2, and a detection limit of 0.86±0.19 μM (S/N=3). This simple and rapid metallization method converts carbon fiber microelectrodes, which are readily accessible, to microscale Pt electrodes in 2 min, providing a platform for oxidase‐based amperometric biosensors with improved spatial resolution over more commonly used platinum electrode array microprobes.  相似文献   

7.
A sensitive hydrogen peroxide (H2O2) biosensor was developed based on a reduced graphene oxide|carbon ceramic electrode (RGO|CCE) modified with cadmium sulfide‐hemoglobin (CdS‐Hb). The electron transfer kinetics of Hb were promoted due to the synergetic function of RGO and CdS nanoparticles. The transfer coefficient (α) and the heterogeneous electron transfer rate constant (ks) were calculated to be 0.54 and 2.6 s?1, respectively, indicating a great facilitation achieved in the electron transfer between Hb and the electrode surface. The biosensor showed a good linear response to the reduction of H2O2 over the concentration range of 2–240 µM with a detection limit of 0.24 µM (S/N=3) and a sensitivity of 1.056 µA µM?1 cm?2. The high surface coverage of the CdS‐Hb modified RGO|CCE (1.04×10?8 mol cm?2) and a smaller value of the apparent Michaelis? Menten constant (0.24 mM) confirmed excellent loading of Hb and high affinity of the biosensor for hydrogen peroxide.  相似文献   

8.
The electrocatalytic reduction of nitrite has been studied by poly(ortho‐toluidine) films modified carbon paste electrode (P‐OT/MCPE). Cyclic voltammetry and chronoamperometry techniques were used to investigate the suitability of poly(ortho‐toluidine) as a mediator for the electrocatalytic nitrite reduction in aqueous solution with various pH. Results showed that pH 0.00 is the most suitable for this purpose. In the optimum pH, the reduction of nitrite occurs at a potential about 600 mV more positive than unmodified carbon paste electrode. The catalytic reaction rate constant, (kh), was calculated 8.68×102 M?1 s?1 by the data of chronoamperometry. The catalytic reduction peak current was linearly dependent on the nitrite concentration and the linearity range obtained was 5.00×10?4 M–1.90×10?2 M. Detection limit has been found to be 3.38×10?4 M (2σ). This method has been successfully employed for quantification of nitrite in real sample.  相似文献   

9.
Relative rate coefficients for the reactions of OH with 3‐methyl‐2‐cyclohexen‐1‐one and 3,5,5‐trimethyl‐2‐cyclohexen‐1‐one have been determined at 298 K and atmospheric pressure by the relative rate technique. OH radicals were generated by the photolysis of methyl nitrite in synthetic air mixtures containing ppm levels of nitric oxide together with the test and reference substrates. The concentrations of the test and reference substrates were followed by gas chromatography. Based on the value k(OH + cyclohexene) = (6.77 ± 1.35) × 10?11 cm3 molecule?1 s?1, rate coefficients for k(OH + 3‐methyl‐2‐cyclohexen‐1‐one) = (3.1 ± 1.0) × 10?11 and k(OH + 3,5,5‐trimethyl‐2‐cyclohexen‐1‐one) = (2.4 ± 0.7) × 10?11 cm3 molecule?1 s?1 were determined. To test the system we also measured k(OH + isoprene) = (1.11 ± 0.23) × 10?10 cm3 molecule?1 s?1, relative to the value k(OH + (E)‐2‐butene) = (6.4 ± 1.28) × 10?11 cm3 molecule?1 s?1. The results are discussed in terms of structure–activity relationships, and the reactivities of cyclic ketones formed in the photo‐oxidation of monoterpene are estimated. © 2001 John Wiley & Sons, Inc. Int J Chem Kinet 34: 7–11, 2002  相似文献   

10.
A novel sensor based on carbon black‐gold nanoparticle nanocomposite modified screen‐printed electrode (CB‐AuNPs/SPE) for the detection of As(III) has been developed. The sensor was prepared modifying the SPE with CB and AuNPs by a drop casting automatable deposition. The As(III) was detected by CB‐AuNPs/SPE using anodic stripping voltammetry, with a high sensitivity (673±6 µA µM?1 cm?2) and reaching a LOD of 0.4 ppb. Finally, CB‐AuNPs/SPE has been applied to As(III) trace analysis in drinking water, obtaining satisfactory recovery values (99±9 %).  相似文献   

11.
Vertically aligned conducting polymer nanowire arrays had great potential applications in supercapacitor electrode material and exhibited enhanced electrocatalytic behavior towards the reduction of nitrite. In this paper, a facial template‐free approach to synthesize large arrays of vertically aligned polyaniline (PANI) nanowires on electrochemically pretreated glassy carbon electrodes was reported by using a galvanostatic current method. The as‐prepared large arrays of PANI nanowires had very narrow diameters and were oriented perpendicular to the substrate, which was a benefit to the ion diffusion when being used as the supercapacitor electrode. The highest specific capacitance of PANI nanowire arrays was measured and kept high at a large charge‐discharge current density. Furthermore, it also can detect nitrite with ultrahigh sensitivity of 62.99 µA mM?1 cm?2 and a remarkable fast response time of less 1 s. The results indicated that the vertically aligned PANI nanowires could dramatically enhance the electrochemical performance.  相似文献   

12.
Prussian blue nanoparticles (PBNPs) were prepared by a self‐assembly process on a glassy carbon electrode (GCE) modified with poly(o‐phenylenediamine) (PoPD) film. The stepwise fabrication process of PBNP‐modified PoPD/GCE was characterized using scanning electron microscopy and electrochemical impedance spectroscopy. The prepared PBNPs showed an average size of 70 nm and a homogeneous distribution on the surface of the modified electrode. The PBNPs/PoPD/GCE showed electrocatalytic activity towards the oxidation of pyridoxine (PN) and was used as an amperometric sensor. The modified electrode exhibited a linear response for PN oxidation over the concentration range 3–38.5 μM with a detection limit of ca 6.10 × 10?7 M (S/N = 3) and sensitivity of 2.79936 × 103 mA M?1 cm?2 using an amperometric method. The mechanism and kinetics of the catalytic oxidation reaction of PN were investigated using cyclic voltammetry and chronoamperometry. The values of α, kcat and D were estimated as 0.36, 1.089 × 102 M?1 s?1 and 8.9 × 10?5 cm2 s?1, respectively. This sensor also exhibited good anti‐interference and selectivity. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
Abstract

Nitrite ion at low concentration is determined spectrometrically by diazotization of p-aminobenzo-phenone and coupling of the resulting diazonium cation with N-(1-naphthy1)-ethylene-diamine to form a reddish-violet coloured water-soluble azo dye with maximum absorption at 555 nm. The method is suitable for the determination of nitrite over the range of 0.04–1.00 ppm. Beer's law is obeyed over this range of concentrations. The observed molar absorptivity and Sandell's sensitivity of the azo dye are 7.0 × 104 mol?1 cm?1 and 6.5 × 10?4 μg cm?2, respectively. Interferences due to other ions were studied to test the selectivity.  相似文献   

14.
In this work, the capability of carbon nanofibers to be used for the design of catalytic electrochemical biosensors is demonstrated. The direct electrochemistry of NADH was studied at a glassy carbon electrode modified using carbon nanofibers. A decrease of the oxidation potential of NADH by more than 300 mV is observed in the case of the assembled carbon nanofiber‐glassy carbon electrode comparing with a bare glassy carbon electrode. The carbon nanofiber‐modified electrode exhibited a wide linear response range of 3×10?5 to 2.1×10?3 mol L?1 with a correlation coefficient of 0.997 for the detection of NADH, a high specific sensitivity of 3637.65 (μA/M cm2), a low detection of limit (LOD=3σ) of 11 μM, and a fast response time (3 s). These results have confirmed the fact that the carbon nanofibers represent a promising material to assemble electrochemical sensors and biosensors.  相似文献   

15.
Thionine (TH) adsorbed on multiwalled carbon nanotubes (MWCNTs) increases the load and dispersion of platinum nanoparticles (PtNPs) generated by chemical reduction of H2PtCl6 with NaBH4. Under the optimum conditions, the PtNPs‐TH‐MWCNTs/Au electrode electrocatalyzed the reduction and oxidation of H2O2 with high sensitivity, and after glucose oxidase (GOx) adsorption it responded to glucose concentration with a sensitivity of 0.14 A M?1 cm?2. The cyclic voltammetric cathodic peak current for NO2? reduction on PtNPs‐TH‐MWCNTs/Au responded linearly to NO2? concentration from 0.5 to 150 µM, with a sensitivity of 5.52 A M?1 cm?2 and a detection limit of 0.2 µM.  相似文献   

16.
Diphenylamine (DPA) monomers have been electropolymerized on the amino‐functionalized multiwalled carbon nanotube (AFCNT) composite film modified glassy carbon electrode (GCE) by cyclic voltammetry (CV). The surface morphology of PDPA‐AFCNT was studied using field‐emission scanning electron microscopy (FE‐SEM). The interfacial electron transfer phenomenon at the modified electrode was studied using electrochemical impedance spectroscopy (EIS). The PDPA‐AFCNT/GCE represented a multifunctional sensor and showed good electrocatalytic behavior towards the oxidation of catechol and the reduction of hydrogen peroxide. Rotating‐disk electrode technique was applied to detect catechol with a sensitivity of 1360 µA mM?1 cm?2 and a detection limit of 0.01 mM. Amperometric determination of hydrogen peroxide at the PDPA‐AFCNT film modified electrode results in a linear range from 10 to 800 µM, a sensitivity of 487.1 µA mM?1 cm?2 and detection limit of 1 µM. These results show that the nano‐composite film modified electrode can be utilized to develop a multifunctional sensor.  相似文献   

17.
The electrochemical redox properties of a surface‐confined thin solid film of nanostructured cobalt(II) tetracarboxyphthalocyanine integrated with multiwalled carbon nanotube (nanoCoTCPc/MWCNT) have been investigated. This novel nanoCoTCPc/MWCNT material was characterized using SEM, TEM, zeta analysis and electrochemical methods. The nanoCoTCPc/MWCNT nanohybrid material exhibited an extra‐ordinarily high conductivity (15 mS cm?1), which is more than an order of magnitude greater than that of the MWCNT‐SO3H (527 µS cm?1) and three orders of a magnitude greater than the nanoCoTCPc (4.33 µS cm?1). The heterogeneous electron transfer rate constant decreases as follows: nanoCoTCPc/MWCNT (kapp≈19.73×10?3 cm s?1)>MWCNT‐SO3H (kapp≈11.63×10?3 cm s?1)>nanoCoTCPc (kapp≈1.09×10?3 cm s?1). The energy‐storage capability was typical of pseudocapacitive behaviour; at a current density of 10 µA cm?2, the pseudocapacitance decreases as nanoCoTCPc/MWCNT (3.71×10?4 F cm?2)>nanoCoTCPc (2.57×10?4 F cm?2)>MWCNT‐SO3H (2.28×10?4 F cm?2). The new nanoCoTCPc/MWCNT nanohybrid material promises to serve as a potential material for the fabrication of thin film electrocatalysts or energy‐storage devices.  相似文献   

18.
《Electroanalysis》2006,18(12):1193-1201
A chemically modified carbon paste electrode with 2,7‐bis(ferrocenyl ethyl)fluoren‐9‐one (2,7‐BFEFMCPE) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The diffusion coefficient (D=1.89×10?5 cm2 s?1), and the kinetic parameter such as the electron transfer coefficient, α (=0.42) of ascorbic acid oxidation at the surface of 2,7‐BFEFMCPE was determined using electrochemical approaches. It has been found that under an optimum condition (pH 7.00), the oxidation of ascorbic acid at the surface of such an electrode occurs at a potential about 300 mV less positive than that of an unmodified carbon paste electrode. The catalytic oxidation peak currents show a linear dependence on the ascorbic acid concentration and linear analytical curves were obtained in the ranges of 8.0×10?5 M–2.0×10?3 M and 3.1×10?5 M–3.3×10?3 M of ascorbic acid with correlation coefficients of 0.9980 and 0.9976 in cyclic voltammetry and differential pulse voltammetry, respectively. The detection limits (2δ) were determined to be 2.9×10?5 M and 9.0×10?6 M with cyclic voltammetry and differential pulse voltammetry, respectively. This method was also examined for determination of ascorbic acid in pharmaceutical preparations.  相似文献   

19.
A new environmentally friendly Au nanoparticles (Au NPs) synthesis in glycerol by using ultraviolet irradiation and without extra‐added stabilizers is described. The synthesis proposed in this work may impact on the non‐polluting production of noble nanoparticles with simple chemicals normally found in standard laboratories. These Au NPs were used to modify a carbon paste electrode (CPE) without having to separate them from the reaction medium. This green electrode was used as an electrochemical sensor for the nitrite detection in water. At the optimum conditions the green sensor presented a linear response in the 2.0×10?7–1.5×10?5 M concentration range, a good detection sensitivity (0.268 A L mol?1), and a low detection limit of 2.0×10?7 M of nitrite. The proposed modified green CPE was used to determine nitrite in tap water samples.  相似文献   

20.
《Electroanalysis》2004,16(4):289-297
The polymer film of N,N‐dimethylaniline (DMA) is deposited on the electrochemically pretreated glassy carbon (GC) electrode by continuous electrooxidation of the monomer. This poly N,N‐dimethylaniline (PDMA) film‐coated electrode can be used as an amperometric sensor of ascorbic acid (AA). The polymer film (thickness (?): 0.3±0.02 μm) having positive charge in its backbone attracts the anionic species AA. Thus, the anodic peak potential (350 mV vs. Ag|AgCl|NaCl(sat)) for the oxidation of AA at the bare electrode is largely shifted to the negative value (150 mV) at this electrode. The PDMA film‐coated electrode is stable in acidic, alkaline and neutral media and can sense AA at different pH's. The diffusion coefficients of AA in solution (D) and in film (Ds) were estimated by rotating disk electrode voltammetry: D=(5.5±0.1)×10?6 cm2 s?1 and Ds=(6.3±0.2)×10?8, (6.0±0.2)×10?8 and (4.7±0.2)×10?8 cm2 s?1 for 0.5, 1.5 and 3.0 mM AA, respectively. A permeability of AA through the PDMA film was found to decrease with increasing the concentration of AA in the solution. In the chronoamperometry, the current response for the oxidation of AA at different times elapsed after potential‐step application is linearly increased with the increase in AA concentration in a wide range of its concentration from 25 μM to 1.65 mM. In the hydrodynamic amperometry, a successive addition of 10 μM AA caused the successive increase in current response with equal amplitude and the sensitivity was calculated as 0.178 μA cm?2 μM?1. So, the fouling of the electrode surface caused by the oxidized product of AA is markedly eliminated at this PDMA film‐coated electrode. A flow injection analysis based on the present electrode was performed to estimate the concentration of vitamin C in fruit juice.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号