首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
Donaldson EM 《Talanta》1979,26(11):999-1010
Methods for determining trace and moderate amounts of antimony in copper, nickel, molybdenum, lead and zinc concentrates and in ores are described. Following sample decomposition, antimony is oxidized to antimony(V) with aqua regia, then reduced to antimony(III) with sodium metabisulphite in 6M hydrochloric acid medium and separated from most of the matrix elements by co-precipitation with hydrous ferric and lanthanum oxides. Antimony (>/= 100 mug/g) can subsequently be determined by atomic-absorption spectrophotometry, at 217.6 nm after dissolution of the precipitate in 3M hydrochloric acid. Alternatively, for the determination of antimony at levels of 1 mug/g or more, the precipitate is dissolved in 5M hydrochloric acid containing stannous chloride as a reluctant for iron(III) and thiourea as a complexing agent for copper. Then tin is complexed with hydrofluoric acid, and antimony is separated from iron, tin, lead and other co-precipitated elements, including lanthanum, by chloroform extraction of its xanthate. It is then determined spectrophotometrically, at 331 or 425 nm as the iodide. Interference from co-extracted bismuth is eliminated by washing the extract with hydrochloric acid of the same acid concentration as the medium used for extraction. Interference from co-extracted molybdenum, which causes high results at 331 nm, is avoided by measuring the absorbance at 425 nm. The proposed methods are also applicable to high-purity copper metal and copper- and lead-base alloys. In the spectrophotometric iodide method, the importance of the preliminary oxidation of all of the antimony to antimony(V), to avoid the formation of an unreactive species, is shown.  相似文献   

2.
A scheme of analysis is presented for the determination of arsenic, antimony, bismuth, lead, selenium, tellurium and tin in steel by evolution of their volatile hydrides and subsequent atomic absorption spectrometry in an argon—hydrogen-entrained air flame. The method is rapid and applicable to a wide range of steels. Detection limits in steel of 1 p.p.m. for arsenic, antimony, bismuth, selenium and tellurium, 2 p.p.m. for tin and 7 p.p.m. for lead are reported. There is some interference in the determination of lead from copper and nickel, but the method could become a viable alternative to existing procedures in the determination of lead in steels of low alloy content, and in irons. Accuracy and precision data are presented.  相似文献   

3.
An atomic absorption spectrometric method is described for the determination of copper, zinc, and lead in geological materials. The sample is digested with HF—HCl—H2O2; the final solution for analysis is in 10 % (v/v) HCl. Copper and zinc are determined directly by aspirating the solution into an air—acetylene flame. A separate aliquot of the solution is used for determination of lead; lead is extracted into TOPO-MIBK from the acidic solution in the presence of iodide and ascorbic acid. For a 0.50-g sample, the limits of determination are 10–2000 p.p.m. for Cu and Zn, and 5–5000 p.p.m. for Pb. As much as 40 % Fe or Ca. and 10 % Al, Mg, or Mn in the sample do not interfere. The proposed method can be applied to the determination of copper, zinc, and lead in a wide range of geological materials including iron- and manganese-rich, calcareous and carbonate samples.  相似文献   

4.
An improved spectrophotometric method is proposed for the determination with iodide of trace amounts of bismuth in copper and cartridge brass. The sample is dissolved in nitric acid and the bismuth is separated from the copper by an ammoniacal precipitation in the presence of iron(III) hydroxide as a gathering agent. The hydroxide precipitate is dissolved in hydrochloric acid, sulfuric acid is added, the solution is evaporated to a few ml, hydrobromic acid is added to volatilize the antimony and tin, and the solution is evaporated to fumes of sulfuric acid. The bismuth iodide color is then developed with a composite potassium iodide—sodium hypophosphite reagent. Factors affecting the bismuth iodide color are investigated.  相似文献   

5.
复杂高铋物料中,铋、砷、锑、锡四元素含量高且共存时会影响铅的测定。特别是铋含量高时对铅的测定影响大。实验用EDTA—酒石酸联合掩蔽铋、砷、锑、锡,在稀硫酸介质中以硫酸钾为沉淀剂,使铅生成硫酸铅钾复盐沉淀而与铋、砷、锑、锡、铁、铜、锌、铝、钴、镍等干扰离子分离,沉淀以乙酸-乙酸钠浸取,二甲酚橙为指示剂,Na2EDTA滴定法测定铅。试验进一步优化了测定条件,确定最佳条件:硫酸(1 1)加入量为7mL、硫酸钾用量为5g、煮沸时为5min、沉淀陈化时间为2h、EDTA 50g/L 加入量为10mL、酒石酸用量为0.5g,铅的回收率99.70% ~100.65%。将实验方法应用于测定复杂高铋物料中铅,标样BY0111-1与给定值一致,相对标准偏差(n=11)RSD 0.20%~0.23%,满足生产测试要求。  相似文献   

6.
In lead-base alloys, copper can be determined by a single controlled-potential electrolysis if less than 1.5% of antimony is present, otherwise, the deposit must be dissolved and re-electrolyzed Iron tends to inhibit the co-deposition of antimony in tin-base alloys, copper and lead can be determined successively. The sample weight is 5 g; percentages as low as 0.2% can be determined.  相似文献   

7.
Tin-titanium alloys are becoming increasingly important; consequently a good method is needed for the determination of tin in this type of material. In this paper an accurate iodometric procedure is proposed for the determination. The sample is dissolved in sulfuric acid and the titanium oxidized with potassium permanganate. Tartaric acid is added and the tin precipitated with hydrogen, sulfide. The sulfide precipitate is dissolved in a mixture of sulfuric, perchloric and nitric acids and the solution evaporated to fumes of sulfuric acid. Water and hydrochloric acid are added, and the tin is reduced with lead and antimony trichloride and titrated with iodine. A study was made of the interfering elements that might be found in titanium alloys. The effect of antimony trichloride in reducing interference from copper was investigated. The method is recommended for titanium alloys containing 0.05 to 5.0 per cent. tin.  相似文献   

8.
A simple procedure is described for the determination of arsenic and antimony in electrolytic copper. The copper is digested with nitric acid and copper is separated from arsenic and antimony by passing an ammoniacal solution of the sample through a column of Chelex-100 resin. After digestion with sulphuric acid and reduction to arsenic(III) and antimony(III) with sodium sulphite in 7 M sulphuric acid at 80°C, both arsenic and antimony are deposited at-0.30V and their total is determined by anodic stripping; antimony is then selectively deposited at -0.05 V for anodic stripping. The lower limits of determination are 56 ng As and 28 ng Sb per gram of copper; relative standard deviations (n = 5) are in the ranges 6.1–15.0% for 5.5—0.5 ppm arsenic in copper and 4.1–6.8% for 2.6—0.6 ppm antimony.  相似文献   

9.
采用硝酸-盐酸溶解样品,在硫酸体系下加入氢溴酸,使得氢溴酸与试样中的砷、锑、锡等元素反应生成易挥发的溴化物,从而消除其干扰,滴定前用氟化氢氨掩蔽铁,在pH=3.0~4.0的范围采用碘量法测定废杂铜屑中的铜含量。用于测定金属样废杂铜屑中铜的含量,测定结果的相对标准偏差(RSD,n=7)为0.20%~0.25%,加标回收率在98.8%~101%,方法简单准确,能够满足日常检测需求。  相似文献   

10.
The polarographic behavior of uranium in hydroxylamine hydrochloride was investigated by differential oscillographic polarography. A procedure is presented for the determination of uranium in plutonium for concentrations of uranium greater than 10 p.p.m. Analyses of solutions containing 22 common impurities found in plutonium metal revealed that antimony, copper, and titanium cause significant interference. A reversible peak corresponding to a one-electron reduction was obtained with a peak potential of -0.167 V vs. Hg pool electrode. The diffusion coefficient is 0.51·10-5 cm2/sec and the diffusion current constant is 1.59 with an average relative standard deviation of 2.28%. The peak current of uranium can be affected by hydrochloric, nitric, perchloric, and sulfuric acids, depending on the acid concentration.  相似文献   

11.
Sargar BM  Anuse MA 《Talanta》2001,55(3):469-478
N-n-Octylaniline in xylene is used for extractive separation of tellurium(IV) from hydrochloric acid media. Tellurium(IV) is extracted quantitatively with the 3% reagent in xylene from 5.5 to 7.5 M hydrochloric acid. It is stripped from organic phase with 1:1 ammonia and estimated spectrophotometrically with pyrimidine-2-thiol (4'-bromoPTPT). The effects of metal ion, acids, reagent concentration, diluents and various foreign ions have been investigated. The log-log plots of distribution ratio (D(Te(IV))) versus N-n-octylaniline concentration indicate that the nature of extracted species is [(RR'NH(2)(+))(2) TeCl(6)(2-)](org). The method affords binary separation of tellurium(IV) from gold(III), selenium(IV), bismuth(III), copper(II), lead(II), antimony(III), germanium(IV) and is applicable to the analyses of synthetic mixture containing associated metal ions and alloy samples. The method is simple, selective, rapid and accurate.  相似文献   

12.
A simple procedure for the determination of selenium and tellurium in electrolytic copper is described. These two elements are first separated from copper by passing an ammoniacal solution of the sample through Chelex-100 resin. Voltammetric interferences from nitrite liberated during the dissolution of the metal sample in nitric acid and from arsenic and antimony present in the metal are eliminated by addition of hydrogen peroxide. Excess of peroxide is quickly decomposed by the copper(II) ions present. As little as 0.01 μg Se g-1 and 0.02 μg Te g-1 can be determined; relative standard deviations (n = 5) are in the ranges 1.4–3.7% for selenium concentrations of 7.3–0.6 ppm in copper and 1.6—3.1% for tellurium concentrations of 4.6—0.5 ppm.  相似文献   

13.
A sensitive spectrophotometric method is described for the determination of thallium in lead, cadmium, indium and zinc metals. Optimal conditions have been established for the extraction and determination of thallium. Thallium is extracted as its bromo complex with tri-n-octylamine and then converted to an iodo complex, the absorbance of which is measured at 400 nm. As little as 1 p.p.m. of thallium in lead, cadmium and zinc metals, and 2 p.p.m. of thallium in indium metal can be determined.  相似文献   

14.
A method has been derived for the selective extraction of antimony(V) from hydrochloric acid solution with ethyl acetate. The method can be employed for the rapid determination of antimony in antimonates of lead, tin, mercury, nickel and chromium and in type metal. Iron(III), cobalt(II) cadmium(II), and large amounts of copper(II) and tin(II) interfere with the extraction. For the analysis of type metal, tin must be oxidized to the tetravalent state.  相似文献   

15.
Traces of antimony, tin and arsenic in cadmium products were determined by pulse polarography. Arsenic was distilled, while antimony and tin were precipitated as hydroxides with manganese dioxide as carrier; some lead was coprecipitated with tin, hence these elements were further separated by distillation. In all cases quantitative recoveries were obtained. Antimony(III) was determined in a hydrochloric acid-sodium hypophosphite mixture, tin(IV) in a hydrochloric-hydrobromic acid mixture and arsenic(III) in sulphuric acid as supporting electrolytes; for arsenic(III), methylene blue had to be added. A sample weight of 10 g and an end volume of 10 ml allowed the determination down to about 0.004 p.p.m. antimony, 0.006 p.p.m. tin and 0.003 p.p.m. arsenic in cadmium. Several synthetic samples and commercially available cadmium products were analysed.  相似文献   

16.
试验研究了铜冶炼烟尘中铜含量的测定方法,试料用盐酸、氢氟酸、硝酸、高氯酸及硫酸分解,氢溴酸除去砷、锡、锑,硫酸除去硒的干扰。进一步对滴定条件和共存元素的干扰及消除进行了试验,最终确定了最佳条件。按照实验方法测定6个铜冶炼烟尘样品中铜量,结果的相对标准偏差为0.22%~0.65%,精密度高,准确度好。样品加标回收率在98.92%~100.38%之间, 适用于铜冶炼烟尘中铜含量为5.00 %~65.00 %的测定。  相似文献   

17.
建立了铅精矿中主量元素铅和次量元素铜的连续滴定分析方法。将铅滴定分析中经硫酸沉淀分离后的滤液,再经硫酸冒烟,用去离子水溶解后,通过滴定法对铅精矿中高含量铜进行分析。该方法铅精矿中铅的检出限为1.4 mg/g,铜的检出限为1.0 mg/g。对3个实际样品中铅、铜分别进行测定,测定结果的相对标准偏差均小于3.0%(n=7),铅的加标回收率为99.71%~100.19%,铜的加标回收率为99.33%~100.47%。该方法通过一次溶样,对铅精矿中的铅、铜连续进行滴定分析,方法快速、准确,适用于铅精矿中含量大于1.4%的铅和含量大于1.0%的铜的测定。  相似文献   

18.
A rapid and sensitive spectrophotometric method has been developed for the determination of bismuth in lead, copper and nickel metals, and in copper-base alloys. Optimal conditions have been established for the extraction and determination of bismuth. Bismuth is extracted with a benzene solution of tri-n-octylamine in the presence of hydrobromic acid and the absorbance of the extract (bromo-complex of bismuth) at 380 nm is measured. As little as 0.5 p.p.m. of bismuth in these metals and alloys can be determined.  相似文献   

19.
A method has been developed for the determination of copper, lead, cadmium and zinc in high purity uranium metal. Conditions are described for the separation of these elements from uranium(VI) and iron(III) by ion-exchange on cellulose phosphate and for their determination by square wave polarography using orthophosphoric acid as base electrolyte.The procedure has been shown to be applicable to metal containing less than 5 p.p.m, of each impurity and results are compared with those obtained by other methods.  相似文献   

20.
A new sensitive method for the extraction and spectrophotometric determination of antimony in the environment is described. The antimony forms a greenish yellow coloured complex with N-phenylbenzohydroxamic acid (PBHA) at 4 M HCl which is extracted from chloroform.

The Sb-PBHA complex is back extracted in 0.01 M NH4OH and then antimony is estimated with rhodamine B in 6 M HCl media. This bluish violet coloured complex is extractable in benzene. The maximum absorbance of the antimony rhodamine B complex is observed at 565 nm. The effects of acidity, reagent concentration and diverse ions are discussed. The method is applied to the trace determination of antimony in industrial effluents and natural resources.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号