首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 18 毫秒
1.
Immobilized polysaccharide-based chiral stationary phases (CSPs) are gaining importance in the resolution of racemic compounds due to their stable nature on working with normal solvents and those prohibited for use with coated phases (tetrahydrofuran, chloroform, dichloromethane, acetone, 1,4-dioxane, ethyl acetate, and certain other ethers). This review discusses the use of immobilized polysaccharide CSPs in the chiral resolution of various racemates by liquid chromatography. The discussion includes immobilization methodologies, enantioselectivities, efficiencies, and a comparison of chiral recognition capabilities of coated vs. immobilized CSPs. Some applications of immobilized CSPs to the chiral resolution of racemic compounds are also presented.  相似文献   

2.
Jun He  Meiling Qi 《中国化学快报》2019,30(7):1415-1418
The new type of triptycene-based stationary phases with alkylated benzimidazolium cations shows high selectivity towards aromatic isomers.  相似文献   

3.
4.
Summary Stabilization of polar and apolar stationary phases with nanosized particles has been demonstrated for gas chromatographic capillary columns. Mixtures of small amounts of (2–10%) of solid particles and liquids form gels, which preserve the stability of the films of stationary phases on the column walls. The stabilization effect of polar and apolar particles has been studied by determining some rheological properties of gels (flow curves, temperature dependence of yield stress values) and validated by gas chromatographic measurements using the most polar and apolar stationary phases. Dedicated to the memory of late Dr. Gábor Alexander, who was the inventor of this film stabilization method, and took active part in the early experiments.  相似文献   

5.
To improve selectivity, chemical stability, and separation efficiency of chromatography, many past papers reported on nanoparticles (NPs) being used as stationary phases in chromatography. This article covers applications of NPs, including carbon nanotubes, fullerenes, gold NPs, silica NPs, zirconia NPs, and titanium-oxide NPs, as stationary phases in gas chromatography, high-performance liquid chromatography, capillary electrophoresis and capillary electrochromatography.We discuss the advantages and the disadvantages of nanomaterials as stationary phases compared to other materials, including traditional stationary phases. We also discuss future possibilities for developing nanomaterial-based stationary phases.  相似文献   

6.
Berthod A  Nair UB  Bagwill C  Armstrong DW 《Talanta》1996,43(10):1767-1782
In this work, synthetic and natural chiral selectors were combined to form two different chiral stationary phases (CSPs). These were made by bonding R- or S-(1-naphthylethyl) carbamate (R-NEC or S-NEC)-derivatized vancomycin molecules to a silica gel support. The two CSPs were evaluated using a set of 60 enantiomeric pairs. The results were compared to the ones obtained with the commercial underivatized vancomycin CSP. Three Chromatographic modes were used: (i) the normal-phase mode using a nonpolar mobile phase with different ratios of hexane and ethanol; (ii) the reversed-phase mode with hydro-organic mobile phases; and (iii) the polar aprotic organic mode with nonaqueous acetonitrile plus small amounts of methanol and an acid and/or base to control retention and selectivity. It is shown that the polarity of the underivatized vancomycin phase is higher than that of the two R- and S-NEC-derivatized CSPs. In the pH range 4-7, there is no ionization change of the chiral selector for the three CSPs. 43% of the studied compounds were resolved by the NEC-derivatized phases when they could not be resolved by the vancomycin CSP. However, the enantiorecognition for 12% of the compounds on the native vancomycin CSP was lost upon NEC derivatization. 45% of the studied compounds were resolved by the NEC-derivatized and native CSPs. The NEC derivatization procedure may block some useful active sites on the vancomycin molecule. Also, the R- and S-NEC moieties are chiral themselves and can contribute additional interaction sites not available on the native vancomycin molecule.  相似文献   

7.
This review covers the recent development of stationary phases for chip-based gas chromatography (GC). Portable systems for rapid and reliable analysis are urgently needed. One way to achieve this is to miniaturize the entire analysis. Because the column is the central component of the GC system and determines the feasibility and quality of separation, this review focuses on stationary phases reported in the literature and their use in different fields during the last two decades, with emphasis on different methods for introducing the stationary phase into the GC column.  相似文献   

8.
Four para-substituted cholesterol cinnamates were synthesized and evaluated for utility as gas chromatograph (GC) liquid crystal stationary phases. The capability of the phases to separate olefinic geometrical isomers was found to be dependent on the position of the olefinic bond. When unsaturation occurred at positions four carbons or greater from the terminal methyl of the compounds investigated, the relative ability of the phases to separate geometrical isomers was p-Cl > p-Me > cholesterol cinnamate > p-MeO derivative > p-NO2. When unsaturation occurred at positions four carbons or less from the terminal methyl the relative ability of the para-derivatives of cholesterol cinnamate to separate geometrical isomers was reversed.  相似文献   

9.
Organic monolithic stationary phases were synthesized in fused-silica capillaries. They were prepared by in situ polymerization under UV irradiation of various alkyl acrylates, 1,3-butanediol diacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid in a ternary porogenic solvent. The resulting stationary phases were tested in CEC. The influence of UV irradiation energy on the resulting separative performances of the monoliths was studied. It was thus demonstrated that the use of hexyl acrylate rather than butyl acrylate and lauryl methacrylate gives highly efficient monoliths (more than 300 000 plates per meter) with optimized EOF. It was also confirmed that the mobile phase ionic strength may affect significantly the separation efficiency. The influence of the nature of the mobile phase organic modifier (ACN or methanol) on EOF, retention, efficiency, and selectivity was studied and differences were observed. Finally, the performances of monolithic stationary phases developed and optimized for CEC separations were evaluated in nanoLC.  相似文献   

10.
Summary Packings and stationary phases applied to high resolution separations of proteins, enzymes, and nucleic acids must satisfy a series of distinct criteria that are different from those usually required by HPLC of low molecular weight non-biologically active analytes. These requirements have been met through substantial improvements in classical gel media together with novel developments in silica supports, and have led to a family of products with tailor-made and reproducible properties. Supports consisting of cross-linked organic gels, and inorganic materials (mostly silicas) are now available with graduated particle sizes, pore sizes, porosities and surface areas as well as non-porous beads. A whole range of stationary phases, such as reversed phase, hydrophobic interaction, ion exchanger and affinity packings, were designed for application as chemical sensors for biopolymer recognition in adsorptive chromatography. The phase systems are operated in the gradient mode, giving high resolution and high peak capacities. In addition, aqueous liquid-liquid partitioning systems have been developed for the fractionation of proteins and nucleic acids. Size exclusion media complete the set of HPLC variants enabling a discrimination of proteins according to their size and shape in an isocratic elution mode. Basically, protein purification and isolation is a multistage process where-by the HPLC variants are combined in a logistic sequence, utilizing the different selectivities of the phase systems and thus maximising resolution, speed and throughput.  相似文献   

11.
Summary Two crown ethers, di(tert-butylbenzo)-propyl-15-crown-5 polysiloxane (PSO-DTB-15C5) and dibenzo-propyl-15-crown-5 polysiloxane (PSO-DB-15C5) have been synthesized and coated onto fused-silica capillary columns. The chromatographic characteristics, including column efficiency, polarity, phase transition temperature, operating temperature range and selectivity, were studied.Excellent selectivity was obtained for the separation of polar position isomers, especially phenol and dinitrotoluene isomers. The separation mechanism is discussed.  相似文献   

12.
Quinine carbamate-type weak chiral anion-exchange selectors (SOs) and the respective chiral stationary phases (CSPs) have been used for the direct liquid chromatographic enantiomer separation of a wide range of chiral acids. In the present work, we demonstrate that these CSPs can also be extended to chiral discrimination of a set of neutral polar potential NMDA (N-methyl-D-aspartic acid) and/or AMPA (alpha-amino-3-hydroxy-5-methyl-4-isoxazole propionic acid) antagonist imidazo-quinazoline-dione derivatives (selectands, SAs) using acetonitrile and methanol containing hydro-organic and buffered mobile phases. The influence of mobile phase composition, column temperature and structure variation of the SAs and SOs on retention and enantioselectivity was systematically investigated to gain insight into the overall chiral recognition mechanism. As was expected for the reversed-phase mode, acetonitrile has a stronger eluotropic effect compared to methanol. Except for two analytes, the acetonitrile containing mobile phases provided baseline resolution (R(S)) of the enantiomers with R(S) values ranging between 1.68 and 2.76. Using methanol as the organic modifier enhanced the enantioselectivity. The enthalpic and entropic terms for the SO-SA association were calculated from the linear van't Hoff plots. Data reveal that the enantiomer separations are predominantly enthalpically driven.  相似文献   

13.
14.
Liquid-crystalline stationary phases for gas chromatography   总被引:1,自引:0,他引:1  
Physico-chemical properties of new liquid-crystalline stationary phases (LCSPs) for gas chromatography are reviewed. The mechanism of chromatographic separation on liquid-crystalline stationary phases is discussed and examples of analyses of complex mixtures of organic compounds using capillary and packed columns are given.  相似文献   

15.
For the first time, a systematic overview deals with the advantages and disadvantages of several stationary phases (polar and non‐polar) and gas chromatographic detectors (flame ionization detector, nitrogen–phosphorus detector and MS) for the determination of 27 amines (aliphatic and aromatic amines and N‐nitrosamines) in water samples. To increase sensitivity (250 mL of sample was eluted with 150 μL of solvent) and matrix elimination, an automatic SPE system was employed prior to GC determination. The best results in terms of resolution and retention times were achieved using a column coated with 5% phenyl‐dimethylpolysiloxane (DB‐5). Capacity factor (k) values for the 27 amines increased with the rise in the polarity of the stationary phase, ranging from 3.0–27.7 and 2.2–14.4 for polar (polyethylene glycol) and non‐polar (DB‐5) columns, respectively. The detection limits of the method were 0.9–9 μg/L for flame ionization detector, 8–95 ng/L for nitrogen–phosphorus detector and 0.2–6.3 ng/L for MS. The precision was similar for the three detectors (RSD, 3.7–6.0%). The GC‐MS method was applied with a high degree of accuracy and precision to determine amines in real samples including tap, river, pond, well, swimming pool and wastewaters.  相似文献   

16.
Chiral stationary phases (CSP) for LC had a major impact on pharmaceutical R&D when they first became commercially available in the 1980s. Even although the use of CSP in pharmaceutical R&D is now very much a mature area, there is still scope for using CSP more effectively to bring about efficiencies. One such instance is the possibility of combining the chiral LC test for the level of a trace enantiomeric impurity in a chiral drug substance and the LC test for related substances into one test. It was envisaged that this could be achieved by carrying out reversed-phase LC on an ODS silica/CSP coupled column system. In evaluating Chiralpak QD-AX, Cyclobond I 2000 DNP and Whelk-O1 CSP using a polar organic - aqueous mobile phase it was found that the Whelk-O1 CSP had good achiral selectivity, the required match of retentivity with the ODS silica material, ACE 5 C18 and also exhibited an encouraging degree of enantioselectivity in the reversed-phase mode. Following consideration of the selectivity of the ACE 5 C18 and Whelk-O1 phases it became apparent that it might be possible to achieve the desired goal of achieving both the enantiomeric impurity and related substances separations in one system by using the Whelk-O1 CSP on its own. This was subsequently demonstrated to be the case using S-naproxen, laevokalim and S-flurbiprofen as illustrative examples.  相似文献   

17.
18.
Chiral metal-organic framework coated open tubular columns are used in the high-resolution gas chromatographic separation of chiral compounds. The columns have excellent selectivity and also possess good recognition ability toward a wide range of organic compounds such as alkanes, alcohols, and isomers.  相似文献   

19.
Summary Enantiomers of several sulfoxides and some selenoxides can be easily separated by using a new chiral stationary phase (CSP-DACH-DNB) containing the 3,5-dinitrobenzoyl derivative of R,R-(-)1,2-diamino-cyclohexane as selector, covalently bonded to the siliceous matrix. The easy operative conditions and the high enantioselectivity values (α) allow a direct transfer of the analytical separations to a semi-preparative and preparative scale.  相似文献   

20.
The chiral recognition capabilities of three macrocyclic glycopeptide chiral selectors, namely teicoplanin (Chirobiotic T), its aglycone (Chirobiotic TAG) and ristocetin (Chirobiotic R), were evaluated with supercritical and subcritical fluid mobile phases. A set of 111 chiral compounds including heterocycles, analgesics (nonsteroidal antiinflamatory compounds), beta-blockers, sulfoxides, N-protected amino acids and native amino acids was separated on the three chiral stationary phases (CSPs). All separations were done with an outlet pressure regulated at 100 bar, 31 degrees C and at 4 ml/min. Various amounts of methanol ranging from 7 to 67% (v/v) were added to the carbon dioxide along with small amounts (0.1 to 0.5%, v/v) of triethylamine and/or trifluoroacetic acid. The Chirobiotic TAG CSP was the most effective closely followed by the Chirobiotic T column. Both columns were able to separate, partially or fully, 92% of the enantiomers of the compound set. The ristocetin chiral selector could partially or baseline resolve only 60% of the enantiomers tested. All separations were done in less than 15 min and 70% were done in less than 4 min. The speed of the separations is the main advantage of the use of SFC compared to normal-phase HPLC. In addition, SFC is advantageous for preparative separations with easy solute recovery and solvent disposal.  相似文献   