首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Colorimetric peroxidase-coupled procedures for the determination of several cerebrospinal fluid (CSF) lipid classes are described. These methods were modified to increase the effectiveness of each cerebrospinal fluid lipid assay by using the sample as the primary diluent for a highly concentrated reagent in an inverse concentration technique. Direct enzymic assays for the determination of CSF cholesterol (free and total), choline phospholipids, and triglycerides were adapted from existing assays to require less than 0.5 ml of sample per assay. This made determinations of the several lipid analytes possible even when samples were from pediatric specimens. In a study model, 51 pediatric CSF samples were analyzed for these lipid constituents. Mean values and standard deviations were determined. Within and between-run studies were performed by sampling from a pool of cerebrospinal fluid specimens. Within-run coefficients of variation for the several proposed procedures were less than 3% while the between-run findings for all of the procedures were less than 5%.  相似文献   

2.
建立了气相色谱-负离子化学电离源质谱同时测定动物组织中氯霉素(CAP)、甲砜霉素(TAP)和氟甲砜霉素(FF)残留量的方法。样品用乙酸乙酯提取,正己烷分配去脂肪,再用Florisil柱进一步净化,甲苯作为反应介质,用N,O-双(三甲基硅基)三氟乙酰胺(BSTFA)-三甲基氯硅烷(TMCS)(体积比为99∶1)进行硅烷化处理,用间硝基氯霉素(m-CAP)作为内标进行测定。CAP的检测限可达到0.03 μg/kg,TAP和FF的检测限可达到0.2 μg/kg;上述3种药物的标准曲线的线性相关系数均大于0.99。CAP,FF和TAP的批内测定的精密度(以相对标准偏差表示)依次为5.5%,10.4%和8.8%;批间测定的精密度依次为7.4%,20.7%和19.1%。回收率为80.0%~111.5%,相对标准偏差为1.2%~15.4%。该方法前处理步骤简单,处理后杂质干扰少,灵敏度高,适用性强,可用于猪肉及禽类、水产品等多种动物组织中氯霉素类药物残留的检测。  相似文献   

3.
The aim of this work was to investigate the efficiency of various MWCNTs as SPE materials for the preconcentration of chlorophenols. The COOH-functionalized MWCNTs and MWCNTs were used as SPE sorbents. To evaluate the capability of MWCNTs for the preconcentration of chlorophenols from water samples, 2,4-chlorophenol, 4-chlorophenol, 2,4,6-chlorophenol, 2,6-chlorophenol, 3,4-chlorophenol, and 2-chlorophenol were used as model compounds. Chlorophenols were extracted with acetone, methanol, ethanol, and dichloromethane, and determined by gas chromatography–mass spectrometry. COOH-functionalized MWCNTs <8 nm were found to be the best sorbent for the tested chlorophenols. For COOH-functionalized MWCNTs <8 nm, the recovery rates for all chlorophenols were higher than 50% when acetone or ethanol was used as eluents. In the case of dichloromethane elution, recovery rates for chlorophenols were from 62.0% for 2,6-DCP to 116.8% for 2,4-DCP; only for 2,4,6-TCP was the recovery rate 30.6%. Similar percentage recoveries were achieved with methanol as the eluent.  相似文献   

4.
《Analytical letters》2012,45(8):1257-1274
Five novel ionic liquids based on quinoline and hexafluorophosphate, including one acidic ionic liquid and four neutral polyethylene glycol-based dicationic ionic liquids, were synthesized and used as extractants for the preconcentration of indigotin and indirubin from Indigowoad roots for the first time. The structures of the ionic liquids were characterized by spectral data. Their solubilities and viscosities were measured, and the latter were correlated with the Litovitz and Arrhenius equations. In the preconcentration of indigotin and indirubin, the type of ionic liquid, concentration of ionic liquid, solid-liquid ratio, temperature, and duration time on the preconcentration efficiency for indigotin and indirubin were investigated. Furthermore, high-performance liquid chromatography was used to determine indigotin and indirubin in Indigowoad roots. High selectivity and enhancement were obtained, and the method was validated for linearity, precision, repeatability, stability, recovery, and accuracy. The limits of detection were 0.0192 microgram per milliliter for indigotin and 0.0236 microgram per milliliter for indirubin, while the limits of quantification were 0.084 microgram per milliliter for indigotin and 0.040 microgram per milliliter for indirubin. This study provides a useful reference for the design and synthesis of task-specific ionic liquids, which may be applied for the separation of similar natural products.  相似文献   

5.
A new styryl dye were prepared, 2-[2-(4-dipropylamino-phenyl)-vinyl]-1,3,3-trimethyl-3H-indolium chloride (DPPTVI) chloride. Its infrared and Raman were measured. Quantum chemical calculations were computed for both the isolated and the solute cation. Optimized geometry, atomic net charges were calculated. The calculated vibrational frequencies were scaled to the experimental ones. Only 12 scale factors were used for the scaling of 174 vibrational modes. Based on these results, normal coordinate analysis were carried out for both the isolated and the solute cations. Infrared and Raman spectra were simulated. The results for the isolated and the solute cations were compared.  相似文献   

6.
High-performance thin-layer chromatography with diode array scanning (TLC-DAD) and high-performance column liquid chromatography with a diode array detector (HPLC-DAD) were used to screen water samples for pesticides. Atrazine, clofentezine, chlorfenvinphos, hexaflumuron, terbuthylazine, lenacyl, neburon, bitertanol, and metamitron were enriched from canal water samples by solid-phase extraction (SPE) on octadecyl silane (C18)/styrene-divinylbenzene-1, C18, C18 Polar Plus, and cyanopropyl (CN) cartridges. Recovery rates were high for all extraction materials except CN, for which values for all pesticides were lower. SPE was used for both preconcentration and fractionation of the analytes. Analytes were eluted by means of methanol and dichloromethane. Methanol eluates were analyzed by HPLC-DAD and dichloromethane eluates by TLC-DAD. The method was validated for precision, repeatability, and accuracy. Calibration graphs were linear between 0.1 and 50.0 microg/mL for all pesticides, and correlation coefficient (r) values were between 0.9994 and 1.000 as determined by HPLC-DAD. Calibration graphs were linear between 0.1 and 1.5 microg/spot for all pesticides, and r values were between 0.9899 and 0.9987 as determined by TLC-DAD. The limit of detection was between 0.04 and 0.23 microg/spot for TLC-DAD and 0.02 and 0.45 microg/mL for HPLC-DAD.  相似文献   

7.
建立了鳗鲡体中丙硫咪唑及其代谢物残留量测定方法。样品用乙腈提取,经正己烷净化后,液相色谱一荧光法测定,标准加入法定量。流动相为:甲醇、乙腈和乙酸铵,梯度洗脱。检测波长为:激发波长290nm,发射波长320nm,丙硫咪唑、2氨基丙硫咪唑砜、丙硫咪唑亚砜、丙硫咪唑砜检出限依次为:25、5、10、1μg/kg。回收率大于95%,相对标准偏差小于8%。  相似文献   

8.
Contactless conductivity detection is successfully demonstrated for the enantiomeric separation of basic drugs and amino acids in capillary electrophoresis (CE). Derivatization of the compounds or the addition of a visualization agent as for indirect optical detection schemes were not needed. Non-charged chiral selectors were employed, hydroxypropylated cyclodextrin (CD) for the more lipophilic basic drugs and 18-crown-6-tetracarboxylic acid (18C6H4) for the amino acids. Acidic buffer solutions based on lactic or citric acid were used. The detection limits were determined as 0.3 microM for pseudoephedrine as an example of a basic drug and were in the range from 2.5 to 20 microM for the amino acids.  相似文献   

9.
Martín Y 《The Analyst》2000,125(12):2230-2235
A method for the determination of three anabolic hormones (diethylstilbestrol, dienestrol and trenbolone) in calf urine is described. After enzymatic hydrolysis, the samples were cleaned up by C18 solid-phase extraction. Drugs were extracted with hexane and analyzed by isocratic elution on a Discovery RP-Amide C16 5 microns column with photodiode-array detection at 240 and 347 nm. Both retention time and UV spectra were used for identification. Detection limits for the HPLC system were calculated to be 0.3 ng injected for all analytes in the standard mixture. However, for urine samples these limits increased because of the presence of unidentified matrix components. After extraction from urine, the limits of detection for the whole analytical procedure were 5 and 10 ng injected for trenbolone and stilbenes, respectively. The average recoveries of the hormones from spiked samples were in the range 53.1-56.7% with RSD between 11.3 and 14.5% for the whole procedure in the concentration range 25-2.5 ng ml-1.  相似文献   

10.
Hydrophilic-hydrophobic IPN materials of poly(acrylic acid)-poly(styrene-co-acrylonitrile) were synthesized and the pervaporation characteristics of the IPN membranes were evaluated for the separation of ethanol/water mixture. Hydrophilic-hydrophobic IPN materials of polyurethane-polystyrene were synthesized and the blood compatibility of the IPN's were measured for the biomedical application. Dicyanate-engineering plastics semi-IPN's were prepared and the morphology and mechanical properties were evaluated for the high temperature composite matrix materials.  相似文献   

11.
介绍用X-射线荧光光谱仪测定钛铁中Si、Mn、P、Al含量的方法,通过试验确定了合适的研磨时间、压力和保压时间,用压片法制样,建立了各元素的工作曲线,各元素的测定范围分别为Si3.00%~6.00%,Mn1.00%~3.00%,P0.030%~0.070%,Al5.00%~9.00%。通过强度测量得到测定Si、Mn、P、Al的相对标准偏差分别为0.074%、0.308%、0.383%、0.040%,精密度满足测试要求。将该方法测定结果与化学法比对,准确度满足国家标准方法分析误差的要求。  相似文献   

12.
Force fields and vibrational wavenumbers were calculated for the molecules SO2X2 (X=F, Cl, Br) using DFT techniques. The previously available experimental data and assignments for SO2F2 and SO2Cl2 were compared with the theoretical results and revised, and new low temperature infrared and Raman data were obtained for SO2Cl2. These data were subsequently used in the definition of scaled quantum mechanics force fields for such molecules. Adjusted wavenumbers were also predicted for the still unknown SO2Br2. A comparison is made with results published for the VO2X2- anions.  相似文献   

13.
In this study a simple and fast miniaturized automated matrix solid-phase dispersion method for the sample preparation and quantitative extraction of pesticides was developed and evaluated. Only 25 mg of sample and 100 microl of organic solvent were used per analysis for this new miniaturized set-up. The extracts were subsequently analysed by GC-MS without any further purification. The method was optimized for oranges and tested for the determination of a variety of organophosphorus pesticides and a pyrethroid at concentration levels below the maximum residue levels set by the European Union and authorities in The Netherlands. The limits of detection were 4-90 microg/kg. The recoveries for pesticides in orange were 83-118% and the relative standard deviations for the total procedure were 10-13% (n=4) at the limit of quantification. The feasibility of the developed method for apple, pear and grapes was also studied. Equally good results were obtained, but for apple the washing step should be omitted.  相似文献   

14.
Two simple and accurate methods to determine atorvastatin calcium (ATO) and fenofibrate (FEN) in combined dosage forms were developed using second-derivative spectrophotometry and reversed-phase liquid chromatography (LC). ATO and FEN in combined preparations (tablets) were quantitated using the second-derivative responses at 245.64 nm for ATO and 289.56 nm for FEN in spectra of their solution in methanol. The calibration curves were linear [correlation coefficient (r) = 0.9992 for ATO and 0.9995 for FEN] in the concentration range of 3-15 microg/mL for ATO and FEN. In the LC method, analysis was performed on a Hypersil ODS-C18 column (250 mm x 4.6 mm id, 5 microm particle size) in the isocratic mode using the mobile phase methanol-water (90 + 10, v/v), adjusted to pH 5.5 with orthophosphoric acid, at a flow rate of 1 mL/min. Measurement was made at a wavelength of 246.72 nm. Both drugs were well resolved on the stationary phase, and the retention times were 1.95 min for ATO and 5.50 min for FEN. The calibration curves were linear (r = 0.9985 for ATO and 0.9976 for FEN) in the concentration range of 3-15 microg/mL for ATO and FEN. Both methods were validated, and the results were compared statistically. They were found to be accurate, precise, and specific. The methods were successfully applied to the estimation of ATO and FEN in combined tablet formulations.  相似文献   

15.
Planar chromatography with diode array scanning (TLC-DAD) and high-performance chromatography with diode array detection (HPLC-DAD) were used to screen water samples for pesticides. Pesticides were enriched from lake water samples by SPE on C18/SDB-1, C18, C18 Polar Plus and cyanopropyl (CN) cartridges. The recovery rates were high for all extraction materials except for all pesticides on CN cartridges, for which the values were lower. SPE was used not only for preconcentration of analytes but also for their fractionation. The analytes were eluted first with methanol and then with dichloromethane. Methanol eluates were analysed by HPLC-DAD, the dichloromethane eluates with TLC-DAD. The method was validated for precision, repeatability and accuracy. The calibration plots were linear between 0.1 and 50.0 microg/mL for all pesticides, the correlation coefficients, r, were between 0.9992 and 1.000 as determined by HPLC-DAD. In the TLC experiments, the best fit for the calibration lines was found when the calibration data were analysed using a second-degree polynomial regression. Calibration plots lay between 0.1 and 17 microg/spot for all pesticides, the correlation coefficients, r, were between 0.9974 and 0.9997 determined by TLC-DAD. The LOD was between 0.04 and 0.65 microg/spot (TLC-DAD) and between 0.02 and 3.68 microg/mL (HPLC-DAD).  相似文献   

16.
Fecal radiobioassay is a sensitive tool to estimate intake of radionuclides, especially for insoluble or poorly absorbed actinides. To increase efficiency and reduce turnaround time, improvements were introduced in the sample digestion step of a fecal bioassay method to rapidly detect Pu and Am. The acid- and microwave-digestion of the spiked fecal samples (5–10 g) were effectively completed in 1 h. The turnaround time for the sample analysis was minimized to 6 h. The average recoveries for Pu and Am were 35% and 60% for artificial fecal samples, respectively. Much better recoveries for Pu and Am were obtained for natural fecal samples. Observed relative biases for Pu and Am were marginally in the range of -0.25 to +0.50. The relative precision values for both radionuclides were, however, within the performance index of 0.4. This rapid fecal method is a potential candidate for an acceptable quantitative radiobioassay and screening method for the suspected Pu/Am exposures.  相似文献   

17.
《Microchemical Journal》2008,88(2):139-146
Solid-phase microextraction (SPME) and solid-phase extraction (SPE) procedures were coupling with microwave-assisted micellar extraction for organochlorine pesticides residues determination in seaweed samples. They were optimized, compared and discussed.Preliminary experiments were performed in order to study experimental conditions for the extraction of pesticides from spiked seaweed samples with microwave-assisted micellar extraction (MAME) using a non-ionic surfactant (Polyoxyethylene 10 Lauryl Ether). After that, SPME and SPE were used to clean-up and preconcentrate MAME extract prior the analysis by liquid chromatography with photodiode array (PDA) detection.Excellent results were obtained for both procedures. Average pesticide recoveries between 80.5 and 104.3% for MAME-SPME and between 73.9 and 111.5% for MAME-SPE were obtained. Relative standard deviations (RSDs) were lower than 10.3% and 5.3% respectively for all recoveries tested, and LOD between 138–348 ng g 1 for MAME-SPME and 2–38 ng g 1 for MAME-SPE were obtained. The method was validated using Soxhlet extraction procedure.Both methods were applied to analyse target organochlorine pesticides in several seaweed samples and results were compared. These results show the great possibilities of combining MAME-SPE-HPLC-UV for the analysis of seaweed samples, improving the selectivity and sensitivity in the determination of organochlorine pesticides analysis for this kind of samples.  相似文献   

18.
Two simple and accurate methods of analysis to determine pioglitazone hydrochloride (PIO) and mefformin hydrochloride (MET) in combined dosage forms were developed using second-derivative spectrophotometry and reversed-phase liquid chromatography (LC). PIO and MET in combined preparations (tablets) were quantified using the second-derivative responses at 227.55 nm for PIO and 257.25 nm for MET in spectra of their solutions in a mixture of methanol and acetonitrile (30 + 70). The calibration curves were linear [correlation coefficient (r) = 0.9984 for PIO and 0.9986 for MET] in the concentration range of 8-40 microg/mL for PIO and 4-12 microg/mL for MET. In the LC method, analysis was performed on a Hypersil ODS-C18 column with 5 microm particle size using the mobile phase acetonitrile-water-acetic acid (75 + 25 + 0.3), adjusted to pH 5.5 with liquor ammonia, at a flow rate of 0.5 mL/min. Measurement was made at a wavelength of 230 nm. Both the drugs were well resolved on the stationary phase, and the retention times were 8.5 min for PIO and 16.0 min for MET. The calibration curves were linear (r = 0.9933 for PIO and 0.9958 for MET) in the concentration range of 4-20 microg/mL for PIO and MET. Both methods were validated, and the results were compared statistically. They were found to be accurate, precise, and specific. The methods were successfully applied to the estimation of PIO and MET in combined tablet formulations.  相似文献   

19.
Low molecular weight alcohols including fusel oil were determined using diethyl ether extraction and capillary gas chromatography. Twelve kinds of alcohols were successfully resolved on the HP-FFAP (polyethylene glycol) capillary column. The diethyl ether extraction method was very useful for the analysis of alcohols in alcoholic beverages and biological samples with excellent cleanliness of the resulting chromatograms and high sensitivity compared to the direct injection method. Calibration graphs for all standard alcohols showed good linearity in the concentration range used, 0.001-2% (w/v) for all alcohols. Salting out effects were significant (p < 0.01) for the low molecular weight alcohols methanol, isopropanol, propanol, 2-butanol, n-butanol and ethanol, but not for the relatively high molecular weight alcohols amyl alcohol, isoamyl alcohol, and heptanol. The coefficients of variation of the relative molar responses were less than 5% for all of the alcohols. The limits of detection and quantitation were 1-5 and 10-60 microg/L for the diethyl ether extraction method, and 10-50 and 100-350 microg/L for the direct injection method, respectively. The retention times and relative retention times of standard alcohols were significantly shifted in the direct injection method when the injection volumes were changed, even with the same analysis conditions, but they were not influenced in the diethyl ether extraction method. The recoveries by the diethyl ether extraction method were greater than 95% for all samples and greater than 97% for biological samples.  相似文献   

20.
Miniaturized sample pretreatments for the analysis of phenolic metabolites in plasma, involving protein precipitation, enzymatic deconjugation, extraction procedures, and different derivatization reactions were systematically evaluated. The analyses were conducted by gas chromatography with mass spectrometry for the evaluation of 40 diet‐derived phenolic compounds. Enzyme purification was necessary for the phenolic deconjugation before extraction. Trimethylsilanization reagent and two different tetrabutylammonium salts for derivatization reactions were compared. The optimum reaction conditions were 50 μL of trimethylsilanization reagent at 90°C for 30 min, while tetrabutylammonium salts were associated with loss of sensitivity due to rapid activation of the inert gas chromatograph liner. Phenolic acids extractions from plasma were optimized. Optimal microextraction by packed sorbent performance was achieved using an octadecylsilyl packed bed and better recoveries for less polar compounds, such as methoxylated derivatives, were observed. Despite the low recovery for many analytes, repeatability using an automated extraction procedure in the gas chromatograph inlet was 2.5%. Instead, using liquid–liquid microextraction, better recoveries (80–110%) for all analytes were observed at the expense of repeatability (3.8–18.4%). The phenolic compounds in gerbil plasma samples, collected before and 4 h after the administration of a calafate extract, were analyzed with the optimized methodology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号