首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid, sensitive, and reliable method for the determination of nifedipine in human plasma is described. Using a single-step solvent extraction and capillary gas chromatography combined with electron capture detection, an assay sensitivity of 2 ng/ml is achieved routinely using 0.5 ml of plasma. Intact nifedipine is quantitated and separated from its nitroso- and nitropyridine-derivatives. The suitability of the assay for pharmacokinetic studies is illustrated.  相似文献   

2.
The Saccharomyces strains uvarum, montuliensis, bayanus, capensis and florentinus were grown in liquid media prepared from a 1% aqueous glucose solution to which 0.05% of ammonium sulfate or urea were added as the only nitrogen supply. The amino acids exuded during incubation were isolated by cation exchange and derivatized as the corresponding N,O-heptafluorobutyryl isopropyl esters. Separation was achieved on a highly deactivated glass capillary column coated with OV-101. A characteristic amino acid profile was obtained for each of the species studied, allowing the construction of a chemotaxonomic tree, on the basis of present or absent acids.  相似文献   

3.
Summary As a follow-up to our previous publication (see ref. [1]) dealing with the experimental system and the fundamental relationships of multi-chromatography („polarity tuning”), the present paper deals with the operation, characteristics and performance of the experimental set-up, and presents experimental verification on the validity of the basic relationships. The possibilities of influencing and adjusting the range in which the capacity factor is changed by the proper selection of column parameters are outlined and the observed changes in the retention index demonstrated. Ways to optimize the relative retentivity to achieve the best possible resolution of multi-component mixtures is illustrated. Finally, the possibility of combining temperature-programmed operation with selectivity tuning in a multi-chromatography system is demonstrated. Continuation of a report based on the papers presented at the 37th Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy (Atlantic City, NJ, March 10–14, 1986), and at the Seventh International Symposium on Capillary Chromatography (Gifu, Japan, May 11–14, 1986). Part I: ref. [1].  相似文献   

4.
5.
An HETP equation for the capillary column is developed that takes into account the dependence of gaseous diffusion on pressure, the compressibility of the mobile phase, together with the unique relationship between mobile phase velocity, and the resistance to mass transfer in the stationary phase. The equation is used to develop a procedure for column optimization and expressions are derived that allow the optimum column radius and optimum column length to be calculated for a given fixed inlet pressure. It is shown that fast, simple separations are optimally achieved using relatively short small diameter columns. Conversely, optimum performance for the separation of complex mixtures requiring higher efficiencies requires the use of long columns with relatively large diameters.  相似文献   

6.
Cryogenic trapping of solutes leads to narrowing of the chromatographic band. By placing the trap at the end of a capillary column, it is possible to study the effectiveness of the trap in terms of producing a sharpened elution profile. The trap may be heated by supplementary heating, but here convective heating from the GC oven is employed simply by turning off the cryogenic coolant. It is estimated that it takes about 50 s for the trap to heat up sufficiently to allow trapped solute to be remobilized, although this depends upon the oven temperature and thermal mass of the trap. It can also be shown that the more volatile solutes mobilize faster from the trap in this particular mode of operation. The recovery of trapped components shows that there is essentially quantitative trapping, and the solutes are trapped just at the leading edge of the trap.  相似文献   

7.
Summary Using a two-step liquid chromatographic separation on normalphase cartridges, crude extracts of diesel particulate matter can be separated without time-consuming sample handling into special fractions which mainly contain slightly-polar oxygenated polycyclic aromatic hydrocarbons (oxy-PAH) and nitrated polycyclic aromatic hydrocarbons (nitro-PAH). Subsequent analysis was by fused-silica capillary gas chromatography on a SE54 column along with flame-ionisation (GC/FID) and positive-ion electron-impact mass spectrometric detection (GC/MS) respectively. A number of individual oxy-PAH belonging to four different chemical classes (ketones, quinones, anhydrides and aldehydes) and several individual nitro-PAH were characterized by their retention times and mass spectra. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

8.
A system for automatic analysis of volatile compounds by purge-and-cold-trapping/capillary gas chromatography is described. It is suitable for analysis of volatile compounds in a wide variety of samples, such as water, food products and environmental samples. Possibilities and limitations of the system are evaluated in relation to several parameters. The efficiency of different types of cryogenic trap (open tubular, coated, packed) is also investigated; it depends on purge-flow rate, temperature of trapping, and total purge volume. Examples of the analysis of volatile compounds in foods and water are given.  相似文献   

9.
A series of computer-constructed van Deemter curves that permits evaluation of a number of variables in capillary gas chromatography is presented. The graphs permit the comparison of inter-related parameters, including the choice of carrier gas (hydrogen vs helium vs nitrogen), column length (10-100 m), column diameter (0.20, 0.25, 0.32, 0.4 mm), solute partition ratios (0-10), and liquid phase film thickness (0.1, 0.25, 0.5, 1.0 μm). The curves are evaluated, both in terms of the relative magnitude of the optimum average linear carrier gas velocity, and in terms of the significance of the sharpness of the curve.  相似文献   

10.
Fluorinated analogs of compounds typical of those found in metabolic and other biological studies are detected with high selectivity using a gas chromatograph/microwave-induced plasma detector (GC-MIPD), which permits fluorine-selective detection by monitoring the emission at 685.6 nm. Using the described atmospheric pressure helium-sustained plasma detector, the minimum detectable level, fluorine selectivity (relative to carbon), and linear dynamic range of this GC-MIPD system were determined to be 4.8 pg-F/s, 1060, and 5000, respectively. The utility of this GC-MIPD system for the selective detection of organofluorine compounds is demonstrated by its application in the analysis of the metabolic fate of a fluorinated substrate administered to a mixture of wheat germ phosphatase and potato apyrase, as well as by analysis of synthetic mixtures.  相似文献   

11.
12.
Two-dimensional gas chromatography with two capillary columns of different polarity (SP 2100 and OV 225) is used for pesticide residue analysis in food samples. By means of “live chromatography” applying pneumatic switching technique according to Deans, unequivocal identification of 57 organophosphorus pesticides in food samples is achieved at trace concentrations. The instrument is equipped with only one injection port and one flame photometric detector. On-line data processing is very helpful, especially in calibration and checking the system's reliability with the multitude of test compounds. The complete pesticide residue analysis including clean-up of about six food samples can be completed by one person in 8 hours.  相似文献   

13.
14.
The analysis time for a given resolution is a complex function of stationary phase selectivity, column radius, and thickness of the stationary phase film. Variation of these parameters has a large effect not only on analysis time, but also on the column inlet pressure and other instrumental requirements. The minimum amount that can be reliably detected as well as the maximum sample capacity of a column are strongly related to the selected column dimensions.  相似文献   

15.
The characterization of heavy petroleum fractions is essential for the design and improvement of cracking plants converting heavy feedstock into valuable “white” products. Conventional simulated distillation methods using packed columns are unsuitable for this purposes, being limited to boiling points up to about 600°C. The method presented is able to cover a boiling points interval ranging from about 150°C up to around 800°C. It employs a short, nonpolar, highly thermostable capillary column routinely operated at temperatures around 430°C. The analytical system is based on a high temperature versions of a fully automatic, capillary dedicated gas chromatograph. The experimental data demonstrate that cold on-column injection is the sole sampling system suitable for such heavy compounds. The conversion of the retention times into boiling points, based on the use of low molecular weight polyethylenes, is extremely reliable, as demonstrated by the excellent retention time reproducibilities. The lower part (up to 550–600°C TBP) of the boiling point distribution curves of heavy petroleum fractions obtained on capillary columns fits well with the corresponding distribution curves based on packed column data. For the petroleum fractions fully eluted from the column the quantitative results obtained either using internal standards or by direct processing of the elution curves are in excellent agreement (less than 0.3 weight% differences). The method has been applied to the determination of the true boiling points corresponding to short path vacuum distillation (DISTACT) cut points over 300°C.  相似文献   

16.
Mesomorphic biphenylcarboxylate esters were coupled via flexible aliphatic hydrocarbon spacers to a polysiloxane backbone. The influence of spacer length, percent mesomorphic substitution, and crosslinking of the stationary phase on liquid-crystalline transition temperatures and on chromatographic performance was investigated. Unique selectivity and good efficiency over a wide temperature range for gum and cross-linked liquid-crystalline phases were demonstrated by the separation of various isomeric polycyclic aromatic compounds.  相似文献   

17.
18.
19.
The elution profiles observed with overloaded capillary columns are well described by a four-parameter theoretical model derived from the basic mass balance equations which relies on an expansion of the partition isotherm to the second term and takes the sorption effect into account. The reliability of the model is demonstrated by the fact that the peak leaning coefficient obtained from a least squares fit of the model to the experimental peak is in good agreement with that obtained from the variation of peak height with retention time at peak maximum. The coefficeint of apparent axial dispersion is independent of sample size and can be used to characterize the plate height at zero concentration of an overloaded capillary column.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号