首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Abstract

A sensitive HPLC method with minimal sample preparation and good reproducibility for the determination of furosemide in plasma and urine is described. Acidified plasma samples were extracted using CH2Cl2 containing desmethylnaproxen as internal standard (IS). Fresh urine samples were incubated with β-gluc-uronidase for 15 minutes and then treated with CH3CN containing IS.

Chromatography was performed on a C18 column with 10 mcl sample injection, Mobile phases were: a) for plasma: 0.01 M NaH2PO4, pH 3.5 - CH3OH (65:35), and b) for urine: acetic acid, pH 3.5 - CHS3OH (60:40) at 3 ml/min and fluorescence detection at Ex 235/Em 389 nm. The plasma standard curve was linear from 0.01 to 15.0 mcg/ml and the urine from 0.5 to 200.0 mcg/ml. The within run CV's were 3,2% at 0.74 mcg/ml plasma and 2.0% at 10.7 mcg/ml urine. Recovery from plasma was 69.9% at 2.0 mcg/ml and 98.6% from urine at 5.0 mcg/ml. The stability of furosemide and its glucuronide were studied. Both methods have been applied to the analysis of plasma and urine samples obtained from human volunteers.  相似文献   

2.
《Analytical letters》2012,45(2):323-335
ABSTRACT

A new radiofrequency capacitively coupled plasma source (r.f.CCP) was used for Cd determination in dust samples by atomic emission spectrometry. The plasma torch consists of a molybdenum tube electrode and one or two ring electrodes situated outside the quartz tube. Plasma was operated at 27.12 MHz, at low power (275 W) and low gas consumption (0.4 1 min? argon flow). The choice of the optimum operating conditions for Cd determination in dust samples dissolved in acids and pneumatically nebulized is presented. The results obtained in such samples were compared with those obtained by flame atomic absorption spectrometry (FAAS). The matrix effect of NaCl and CaCl2 on Cd emission was also studied depending of the plasma coupling system. The true limit of detection for Cd in dust sample by r.f.CCP-AES is 3 μg g?1. Concentration of Cd higher than 10 μg g?1 can be determined by the proposed method with a relative standard deviation within the range 5 - 10%. The recovery is 100 ± 10%.  相似文献   

3.
Abstract

A high performance liquid chromatographic (HPLC) technique has been developed for the determination of bupropion hydrocloride (Bup) in human plasma, using a reversed-phase method, with UV detection at 250 nm.

The internal standard 5-(P-methylphenyl)-5-phenylhydantoin (MPPH), was used as an aid to quantitation. The plasma was deprotemized with acetonitrile and the clear supernatant was directly injected in the chromatographic system. The lower limit of quantitation was 5.0 ng/ml using only 100 μl of plasma sample.

Linear regression analysis for the calibration plots obtained on five different days over a two-week period for the the two ranges used (10–250 ng/ml and 250–2000 ng/ml) in plasma indicated excellent linearity and reproducibility. The mean recovery of spiked Bup in plasma samples over the concentrations studied was found 96.5 ± 3.14%.

The method revealed that more than 30% of Bup was lost when the supernatant was stored at room temperature for 24 hrs.  相似文献   

4.
《Analytical letters》2012,45(9):1483-1485
Abstract

Arrhythmic patients treated with quinidine have been found to ingest caffeine from various sources. Caffeine interferes with the quantitation of quinidine in plasma samples. This method for determination of quinidine in plasma is based on high performance isocratic liquid chromatography with the use of a C-18 bonded reverse phase column at room temperature. Unlike some liquid chromatographic procedures for quinidine, caffeine does not interfere. Quinidine is extracted from alkalinized plasma into benzene. The benzene layer is removed and evaporated to dryness under nitrogen at 50 C. The residue is reconstituted with methanol and injected into the column. The mobile phase is 30/70 (v/v) mixture of methanol/0.4% glacial acetic acid. Analysis can be completed within 10 minutes. The procedure is sensitive (0.5mg/L) and is well reproducible (CV= 3.5% for a 2 mg/L concentration in plasma).  相似文献   

5.
Abstract

A reversed-phase high-performance liquid chromatographic procedure was developed to analyze 75 μ/m1 volumes of chinchilla middle ear effusion and plasma for amoxicillin. The small sample volumes were dictated by the chinchilla model we use to study otitis media and our need to collect multiple samples over an 8-h dosing interval. Amoxicillin was separated on an octylsilane column using methanol-10 mM sodium dihydrogen phosphate-acetonitrile, (88:10:2, v/v), pH 3. Amoxicillin and the internal standard were detected at 230 nm. Middle ear effusion and plasma samples were precipitated with perchloric acid and neutralized prior to injecting 6 μ onto the column. The limit of quantitation in plasma and middle ear effusion was 0.5 μ/m1 (coefficient of variation 14.8% and 18.2%, respectively), and 99% of amoxicillin was recovered.  相似文献   

6.
Abstract

Following the stabilization of the plasma samples with HClO4 and EDTA, the samples could be directly analyzed by HPLC using electrochemical detection and reversed-phase columns. The accuracy and precision of the method was evaluated using plasma samples spiked with ascorbic acid (10 μg/ml) and the results were also compared to the classical colorimetric procedure. Dehydroascorbic (5 μg/ml) was determined in plasma samples using UV detection following derivatization at room temperature for 45 minutes with o-phenylenediamine.  相似文献   

7.
Abstract

Norepinephrine and epinephrine were isolated from human plasma at picogram levels by solid phase extraction (SPE), on a proprietary weak cation exchange silica based packing. Plasma samples were spiked with catecholamines at two concentrations to simulate body response to varying levels of stress. Recoveries of norepinephrine and epinephrine at both concentrations exceeded 95%.

An analysis of catecholamines by ion pair high-performance liquid chromatography with amperometric detection is described.  相似文献   

8.
Abstract

A quantitative high pressure liquid chromatographic (HPLC) assay has been developed for the determination of isoniazid (INH) and acetylisoniazid (ACINH) in human plasma. Plasma samples were taken from a patient after oral administration of INH (with proven tuberculosis infection). A C18 reversed phase radial compression column was used to separate INH and ACINH from other plasma components. The analysis takes 10 minutes per sample and the lower limit of detection for each compound is 0.10 ug/ml plasma.  相似文献   

9.
Abstract

A high performance liquid chromatographic [HPLC] method that involves the use of a silica gel column and an aqueous mobile phase for quantitation of chlorpheniramine in plasma and urine is presented. Alkalinized samples are cleaned by extraction with pentane [containing 1% CH3CN], and the extraction is followed by evaporating the solvent and reconstituting the residue in a small amount of mobile phase. An aliquot of this solution is analyzed by an HPLC system with an Ultrasphere Si Column, an aqueous mobile phase at pH 7 containing 60% CH3CN and 7.5 mM [NH4]2HPO4, and UV detection at 200 nm. Although the average recovery of extraction is 58% ± SD 10%, the detection limit for the method is 0.7 ng/ml in plasma and 100 ng/ml in urine [s/n = 3] for 0.5 ml samples. The coefficients of variation [CV] on the results of samples run to measure interday and intraday precision and the bias on control samples were all 10% or less. We have used the method in a bioavailability study of a controlled release formulation involving over 1000 samples.  相似文献   

10.
Abstract

A liquid chromatographic method is described for the determination of the new fluoroquinolone Ro 23–6240 and its N-demethyl and N-oxide metabolites in plasma and urine. The three substances were extracted from aqueous solution with dichloromethane/isopropanol containing sodium dodecyl sulphate. After evaporation and reconstitution, samples were analysed on a reversed-phase column using ion pair chromatography and fluorescence detection. The limit of quantification was 10–20 ng/ml (RSD 4%) using a 0.5 ml plasma sample, and the inter assay precision was 3–10% over the concentration range 50 ng/ml to 20 μg/ml. Recovery from plasma was 81% (RSD 10%) over the range 10 ng/ml to 5 μg/ml. The method has been applied successfully to the analysis of several thousand samples from human pharmacokinetic studies. Care has to be taken to avoid exposure of samples to direct sunlight, and the use of opaque vessels for sample storage and handling is recommended.  相似文献   

11.
Abstract

A sensitive, reliable and specific high performance liquid chromatographic procedure has been developed for the quantitation of cyproheptadine in plasma or urine. After extraction of the drug with ethyl acetate from alkalinized samples, the organic extract was evaporated to dryness, reconstituted with acetonitrile and chromatographed using a C8 reversed-phase analytical column with UV detection at 254 nm. The average recoveries of cyproheptadine from spiked plasma and urine samples in the concentrations ranging from 0.2 – 3 mcg/ml were 95.7 and 100.3%, respectively and their respective CV was 4.1 and 3.9%. Regression analyses for the calibration plots for plasma and urine standards obtained on three different days for the drug concentrations between 0.2 – 3 mcg/ml indicated excellent linearity (r > 0.999) and reproducibility (CV < 2.0%, p > 0.01). The limit of sensitivity was 50 ng/ml for both plasma and urine samples. The method was applied to monitor the plasma concentration versus time profile of cyproheptadine following a single bolus IV dose of 1 mg/kg in a dog.

Urine samples taken from a human subject for the duration of 24 hours following a single oral dose of 8 mg showed that the cumulative amount excreted in urine as cyproheptadine was approximately 1% of the dose.  相似文献   

12.
Abstract

Objectives: The objective of this study was the investigation of age- and sex-associations in a set of blood plasma metabolites in healthy male and female subjects.

Methods: A comparison study design with male and female subjects of various ages was used. Metabolic profiling was performed using electrospray ionization tandem mass spectrometry that yielded 186 metabolite concentrations for each study participant. The key age-related metabolites were identified using an integrative analysis of absolute concentrations, metabolite ratios and the differential correlation of pairwise metabolite concentrations. All of the age-associated metabolites were adjusted prior to the analysis to account for differences in Body Mass Index (BMI).

Results: A total of 236 plasma samples from 140 female and 96 male subjects aged 20 to 82 years-old were collected and analyzed in the study. 13 and 14 age-associated metabolites (|r|?>?0.33 and p < 6.6×10?5), 438 and 337 age-associated metabolite ratios (|r|?>?0.37 and p < 3.5×10?6), and 5 and 10 core metabolites were discovered in the female and male groups, respectively. 80% of the metabolites displaying associations with age belonged to sphingolipids and phosphatidylcholines, and the two sexes shared less than 50% of the age-associated metabolites.

Conclusion: The study found that changes in metabolite concentrations, metabolite ratios and differential correlations were age and sex-specific.  相似文献   

13.
Abstract

An easy to perform, specific, reproducible and sensitive high performance liquid chromatographic (HPLC) method to measure pyridostigmine concentration in human plasma was developed and validated. Sample clean-up consists of ion-pair extraction into dichloromethane in the presence of neostigmine as internal standard, followed by back extraction into an aqueous phase. Mean recovery of 110% (with a standard deviation of 10%) was determined for concentrations of 5 – 100 ng/ml. Chromatography on a 125·4 mm CN-propyl column using a mobile phase composed of 10% acetonitrile in 3.5×10?4M NaH2PO4 and UV detection at 270 nm, yields clean chromatograms without any interferences from endogenous plasma components. Using 1 ml plasma samples the method has a limit of detection (LD) of 3 ng/ml, with %CV (precision) and bias (accuracy) ≥ 10% for concentrations in the range of 0–100 ng/ml. The method is being used in human pharmacokinetic studies of oral dosage forms of pyridostigmine.  相似文献   

14.
《Analytical letters》2012,45(11):1345-1355
Abstract

A sensitive and reliable liquid chromatographic assay procedure for the quantitation of oxamniquine in plasma or urine was developed. Chromatographic separation was achieved on a reversed-phase phenyl colum using U.V. Detection at 254 nm. The eluting solvent was the mixture of 0.05 M acetate buffer pH 5 and acetonitrile (3:7). With this mobile phase the drug and its external standard were well separated from the interference of the blank samples. The average recovery of oxamniquine from 3 or more replicate dog plasma samples of different concentration (0.125 ? 4.00 μg/ml) was 95.5% and its coefficient of variation was 4.17%. The reproducibility of the assay was confirmed by the analysis of variance test for the slopes of the three standard plots obtained from plasma samples at three different occasions (F=4.2, p > 0.01). The detection limit for plasma samples was approximately 20 ng/ml. The method was applied to measure the plasma level vs, time profile of this drug following a single bolus intravenous dose of 16 mg/kg to a dog.  相似文献   

15.
Abstract

A sensitive and selective HPLC assay has been developed for the analysis of a new antihypertensive agent in human plasma. The drug and internal standard were isolated from plasma by liquid-liquid extraction. Separation was accomplished on unmodified silica gel with a mobile phase of 60:40 acetonitrile:10 mM dibasic ammonium phosphate. Detection was by UV absorbance at 291 nm. The method is linear over a range of 20 to 4000 ng/ml. Relative error of calibration and control standards ranged from ?1.5 to 5.0% and precision, as indicated by relative standard deviation, ranged from 0.8 to 5.2%. The method has been successfully used for analysis of plasma samples from human volunteers following oral administration of PD 78,799.  相似文献   

16.
Abstract

A simple, rapid and sensitive assay, capable of quantitating quinine (Q) in human plasma samples is reported. The assay uses a reversed-phase C18 HPLC column packed with 5 μ ODS Hypersil. The chromatographic separation was accomplished with an isocratic mobile phase comprising acetonitrile-aqueous phosphate buffer pH 2 (50:50, v/v) containing 25 mM sodium dodecyl sulfate and 3 mM tetrabutylammonium bromide at a flow rate of 0.5 ml/min. The eluant was monitored by a fluorescence detector (excitation wavelength at 350 nm and emission wavelength at 450 nm). The assay was based on a simple plasma protein precipitation technique. To 200 μ of plasma sample, 400 μ of internal standard (cinchocaine 30 μ/ml in methanol) was added. After brief vortexing and centrifugation, the clear supernatant was injected onto the HPLC column. The inter- and intra-assay coefficients of variation were found to be less than 10%. The lowest limit of detection for Q in plasma was 18 ng/ml.  相似文献   

17.
《Analytical letters》2012,45(1):131-140
Abstract

A high performance liquid chromatographic method for quantitating matoclopramide in plasma is presented. Proteins ara precipitated from the plasma sample with acetonitri la containing the internal standard, procainamida. The treated samples ara than analyzad using an Ultrasphere Si column, an aqueous solution at pH 7 of 65% CH3CN and 5.0 mM (NH4)2HPO4 as a mobile phase, and a fluorescence detector. The retention times for drug and intarna1 standard ara 11.2 and 13.2 min, respectively. The caibration curve is Linear from 0.89 to 44.5 ng/ml. The detection limit is 0.89 ng/ml [signaL/hoisa = 31] for 0.2 ml plasma samples Pracision is measured by intraday and intarday coefficients o f variation, which are less than 10%. This method is currently being used for pharmacokinetic studies of methoclopramide.  相似文献   

18.
Abstract

A reliable, highly reproducible, accurate and time-efficient high performance liquid chromatographic (HPLC) method to measure atenolol concentration in human plasma was developed and validated. Sample clean-up consists of simple and efficient liquid-liquid extraction (mean recovery 103%) which allows a high sample throughput. Chromatography on a CN-propyl column yields symmetrical and well resolved peaks for atenolol and for the internal standard (metoprolol) without any interference from endogenous plasma components. Using 1 ml plasma samples the method has a limit of detection of 12.6 ng/ml (calculated at a 99.9% confidence level) with %CV (precision) ≥ 8.8% and bias (accuracy) ≥ 3.8% for concentrations in the range of 10 – 1000 ng/ml. We now routinely use this method in human pharmacokinetic studies of atenolol dosage forms.  相似文献   

19.
Abstract

Extracted aquatic fulvic acid samples (HO10FA) from a brown lake Hohloh in the Black Forest (Germany) were ozonated at two different ozone doses and then chlorinated. In connection with liquid chromatography and further detection systems (UV and DOC) on gel matrix, a combined system (gel chromatograpy) was used for a detailed characterization of ozonated and post-chlorinated fulvic acid samples. The gel chromatographic characterization showed a slight decrease in DOC (14%) and SAC254 (36%) at the end of 20 min ozonation whereas the low ozonation time (5 min) caused increases in DOC (6%) and SAC254 (56%).  相似文献   

20.
Abstract

A reversed-phase, isocratic HPLC method has been developed for the quantitation of desipramine in human plasma. the method involved the use of cloimpramine as an internal standard. the chromatographic separation was accomplished with a mobile phase comprising acetonitrile-aqueous solution (60:40. v/v) containing 10 mM disodium hydrogenphosphate and 80 mM sodium dodecyl sulfate adjusted to pH 2. the mobile phase was pumped at a flow rate of 0.5 ml/min. the column used was a microbore column (2 mm I.D. × 100 mm) packed with a C18 reversed-phase material (5μm ODS Hypersil). Plasma samples were extracted at basic pH with diethyl ether followed by back-extraction into 0.1 N sulfuric acid. Using UV detection at 250 nm, the lower limit of sensitivity was 10 ng/ml. the inter- and intra-assay coefficients of variation were found to be less than 10%. the assay procedure was applied to a long term oral dosing study in patients to monitor the plasma concentration of desipramine.  相似文献   