首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(10):1833-1843
Abstract

A simple and rapid liquid chromatographic assay method using a fluorescence detector for quantitation of dihydroergotamine in plasma without extraction was developed. After precipitating the protein with acetonitrile, the supernatant liquid was directly injected for analysis. Chromatographic separation was achieved on C18 reversed phase column and the mobile phase was the isocratic mixture of methanol, acetonitrile and glycine buffer (0.5:3.5:6.0). With this eluting solvent the drug and its internal standard were well separated from the interference of the plasma sample. The average recovery of dihydroergotamine from 6 replicate samples of different concentrations (5-30 ng/ml) were 92.2 ± 3.37%. The minimum amount of dihydroergotamine detectable by this method was 2 ng/ml of sample.  相似文献   

2.
《Analytical letters》2012,45(2):135-160
Abstract

A rapid, sensitive and specific high pressure liquid chromatographic (HPLC) assay was developed for the determination of chlordiazepoxide and its metabolites from plasma. The assay involves extraction of chlordiazepoxide and its metabolites into diethyl ether from plasma buffered to pH 9. The overall recovery of chlordiazepoxide is 80 ± 5.0% (S.D.) and the sensitivity limit of detection is 50 to 100 ng/ml of plasma, using a 1 ml specimen. The assay was used in the determination of plasma levels of chlordiazepoxide and its metabolites in man following oral administration of chlordiazepoxide. HCl.

The chromatographic behavior of other clinically important benzodiazepines and their major metabolites is also reported.  相似文献   

3.
Abstract

A selective and sensitive method for the determination of piritramide in human plasma is described. After addition of 50 μl of 2 M ammonia and 20 μl of aqueous promethazine solution (100 ng/10 μ1) as an internal standard, 1 ml of plasma was extracted with 5 ml of toluene (extraction efficiency: 93.9 × 2.6%; mean × S. D.; n = 5). HPLC was performed with a phenyl hypersil NC-04 column, particle size 5 μm, 250 × 4 mm I. D.; mobile phase: 8 parts of acetonitrile and 2 parts of 10 mM potassium phosphate buffer (pH 3. 3). The flow rate was set to 2 ml/min and the column temperature was 22°C. The assay was linear in a concentration range of 3.75 ? 3000 ng/ml (r = 0.999), with a lower limit of detection of 3 ng/ml. The precision was determined using spiked plasma samples (15 ng/ml; 300 ng/ml), with coefficients of variation of 6.1 and 5.9% (intraday; n = 5) and 6.5 and 0.2% (interday; n = 3). In the range of 5.6 ? 1500 ng/ml, the accuracy of the assay was 2.82%. The method was used for the determination of piritramide plasma concentrations in patients receiving intra- or postoperative analgesia.  相似文献   

4.
Abstract

A high-performance liquid chromatographic method for the analyses of ciprofloxacin (BAY o 9867) (1-cyclopropyl-6-fluoro-1,4-dihydro-4-oxo-7-(1-piperazinyl)-3-quinoline carboxylic acid hydrochloride) in human serum, plasma and urine samples is described. Diluted serum, plasma, and urine samples are injected onto a RP-18 column without prior extraction or clean-up procedure. Ciprofloxacin is separated from the ballast by an eluent consisting of an 0.025M H3PO4 solution adjusted to pH=3 with tetrabutylammonium hydroxide and acetonitrile.

Ciprofloxacin is detected fluorimetrically giving a detection limit of 8ng/ml in plasma and serum and of 50ng/ml in urine. A statistical evaluation of the assay showed acceptable accuracy and precision for 10 to 500ng of BAY o 9867 per ml in serum and plasma and for 50ng to 600ng of BAY o 9867 per ml of diluted urine specimens. This method was used to monitor the concentrations of BAY o 9867 in serum, plasma and urine of volunteers after oral administration of ciprofloxacin.  相似文献   

5.
《Analytical letters》2012,45(13):2391-2400
Abstract

A simple and rapid high-performance liquid chromatographic (HPLC) method for the determination of amiodarone (AD) in plasma and tissues was developed. The method involved deproteinization of plasma or homogenized tissue with acetonitrile containing an internal standard (N-Cetylpyridinium chloride) followed by reversed phase chromatography using μ bondapack C18 column (10μm) with a mobile phase consisting of acetonitrile - methanol - sodium dihydrogen phosphate buffer (70:10:20%, v/v), the pH adjusted to 4.0 and pumped at flow rate of 1.0 ml/min. The column effluent was monitored at 242 nm. A linear relationship was obtained between peak height ratios (drug to internal standard) versus drug levels over the concentration range of 50–750 ng/ml. The detection limit of AD in plasma and tissues by this method was 20 ng/ml.  相似文献   

6.
Abstract

An easy to perform, specific, reproducible and sensitive high performance liquid chromatographic (HPLC) method to measure pyridostigmine concentration in human plasma was developed and validated. Sample clean-up consists of ion-pair extraction into dichloromethane in the presence of neostigmine as internal standard, followed by back extraction into an aqueous phase. Mean recovery of 110% (with a standard deviation of 10%) was determined for concentrations of 5 – 100 ng/ml. Chromatography on a 125·4 mm CN-propyl column using a mobile phase composed of 10% acetonitrile in 3.5×10?4M NaH2PO4 and UV detection at 270 nm, yields clean chromatograms without any interferences from endogenous plasma components. Using 1 ml plasma samples the method has a limit of detection (LD) of 3 ng/ml, with %CV (precision) and bias (accuracy) ≥ 10% for concentrations in the range of 0–100 ng/ml. The method is being used in human pharmacokinetic studies of oral dosage forms of pyridostigmine.  相似文献   

7.
Abstract

A rapid method for the simultaneous quantitation of the H2-receptor antagonist drugs cimetidine and ranitidine in human plasma by isocratic ion-pair reverse-phase HPLC is described. The method involves a simple organic extraction step of the alkalinized plasma containing added internal standard followed by back extraction of the extract with dilute acetic acid and subsequent analysis of the aqueous acidic phase on a reverse-phase (C18) column. The eluting solvent was acetonitrile-water (20:80 v/v) containing 0.005 mole/litre octanesulphonic acid and was monitored at 229 nm. The run time for the assay was 12.5 minutes, with a detection limit for cimetidine of 50 ng/m1/(0.2 μmole/1) and that for ranitidine was 20 ng/ml (0.06 umole/1).  相似文献   

8.
《Analytical letters》2012,45(8):1348-1365
Abstract

A rapid and specific liquid chromatography/tandem mass spectrometry method was described for the simultaneous determination of hydrochlorothiazide and valsartan in human plasma. After extracted from plasma using methanol, hydrochlorothiazide, valsartan and hydroflumethiazide, irbesartan, used as the internal standard, respectively, were chromatographically analyzed on a Phenomenex Kromasil C8 column with water and methanol (27:73, v/v) as the mobile phase. Selected reaction monitoring was specific for mass detection employing negative electrospray ionization. The calibration standards were linear over the concentration range (3.13–800 ng/ml for hydrochlorothiazide and 11.72–3000 ng/ml for valsartan). The method was found to be suitable for application to a pharmacokinetic study after oral administration of dispersible tablet containing 12.5 mg hydrochlorothiazide and 80 mg valsartan to 20 healthy volunteers.  相似文献   

9.
Abstract

A sensitive and specific reverse phase HPLC assay has been developed to measure the new antitumor agent arabinosyl-5-aza-cytosine (ara-AC) in biological fluids at concentrations as low as 50 ng/ml (0.2 μM). This assay also detects arabinosyl-N-formyl-guanylurea (AGU-CHO), the initial hydrolytic metabolite of ara-AC. 2′-Deoxy-5-azacytidine, an analogue with similar chemical stability, is used as an internal standard. Chromatographically interfering plasma ribosides are removed by solid phase extraction on a phenyl boronic acid cartridge. Separation of ara-AC, AGU-CHO and internal standard is then accomplished isocratically (1% CH3CN in 10 mM pH 6.8 phosphate buffer) on fully carbon loaded and end-capped C8 and C18 columns connected in tandem. The compounds of interest are detected by UV absorption at 240 nm and total analysis time is 20 min. This assay has been used to determine bolus dose plasma kinetics in male BDF1 mice given 200 mg/kg ara-AC as a tail vein injection. Plasma elimination of the ara-AC is triphasic with a terminal phase half-life of 52 min and the elimination of the AGU-CHO metabolite parallels that of the parent drug. Analysis of ara-AC in human plasma indicates that this method is suitable for determining drug disposition and pharmacokinetics in human subjects.  相似文献   

10.
《Analytical letters》2012,45(14):2689-2702
Abstract

A simple and rapid high-performance liquid chromatographic (HPLC) assay for the determination of the antimalarial drug arteether in plasma was developed and validated in this report. Perchloric acid was used in this method as a plasma protein precipitant and to attain an acidic medium suitable for the decomposition of arteether to a derivative possessing UV absorption. This derivative and the internal standard (progesterone) were separated from the plasma on a 10 μm μ-Bondapack C18 reversed-phase column at ambient temperature with a mobile phase composed of acetonitrile:water (60:40 v/v) and at a flow rate of 1.5 ml/min. The effluent was monitored at 254 nm with a UV detector. Linear relation between drug concentrations and peak height ratios of arteether derivative to the internal standard was achieved in the range of 0.25-10 μg/ml arteether with a detection limit of 50 ng/ml arteether in plasma. The within-day and between-days precisions were evaluated using 3 different concentrations of arteether. The values of the coefficients of variation were 1.35-1.68% and 1.65-2.82% for within-day and between-day, respectively. This method was applied to determine some pharmacokinetic parameters of arteether after intramuscular injection of 50 mg/kg arteether oily solution to rabbits.  相似文献   

11.
Abstract

This report describes a sensitive, selective and robust assay for bunaprolast and an active metabolite in canine and human plasma. Method development was complicated in that bunaprolast is quickly hydrolysed by esterases even in vitro, and the metabolite is rapidly oxidised in dilute aqueous solutions. Effective measures to stabilize analytes in biological matrices and during sample extraction are described.

The method involves the selective solid phase extraction of analytes with a close analogue as internal standard followed by reversed phase HPLC and fluorescence detection. The limit of quantification was typically less than 1 ng/ml, and the assay was linear over the range 1 - 1,000 ng/ml.  相似文献   

12.
Abstract

An HPLC instrument coupled with an electrochemical detector was used to determine ritodrine (erythro-p-hydroxy-α-[1-[(p-hydroxyphenethyl)-amino]ethyl] benzyl alcohol hydrochloride) at nanogram levels in serum. Extraction of ritodrine was accomplished using a multistep ethyl acetate procedure, and the mobile phase consisted of acetonitrile, ammonium acetate, glacial acetic acid, and a counterion. The stationary phase was a Biophase ODS 5 μm column at ambient temperature. Nalbuphine hydrochloride (Nubain®) was used as an internal standard to quantitate the ritodrine levels of pregnant patients receiving ritodrine. The procedure's linearity for both ritodrine standards and spiked plasma samples was demonstrated. The precision of the assay was found to be 3.4% at 20 ng/ml ritodrine. The minimum detectable concentration, with a signal-to-noise ratio of 6, was determined to be 0.31 ng per 50 μl injected, corresponding to a concentration of 0.6 ng/ml plasma. The sensitivity, precision, and reproducibility of the assay were all found to be acceptable for determining ritodrine in patient serum.  相似文献   

13.
Abstract

A sensitive and rapid assay has been developed for the determination of LY217332, a 3'-imidazolo[4,5-c]pyridinium cephalosporin, in plasma. The method utilizes cyano solid phase column extraction and HPLC with ultraviolet detection. The lower limit of detection is 5 ng/ml plasma and the relative standard deviation for precision and accuracy was 5% or less from 50–500 ng/ml. The method is applicable to the assay of ceftazidime, cephaloridine, cefpirome and BMY-28142 with minor modification of the mobile phase and the detection wavelength.  相似文献   

14.
《Analytical letters》2012,45(1):131-140
Abstract

A high performance liquid chromatographic method for quantitating matoclopramide in plasma is presented. Proteins ara precipitated from the plasma sample with acetonitri la containing the internal standard, procainamida. The treated samples ara than analyzad using an Ultrasphere Si column, an aqueous solution at pH 7 of 65% CH3CN and 5.0 mM (NH4)2HPO4 as a mobile phase, and a fluorescence detector. The retention times for drug and intarna1 standard ara 11.2 and 13.2 min, respectively. The caibration curve is Linear from 0.89 to 44.5 ng/ml. The detection limit is 0.89 ng/ml [signaL/hoisa = 31] for 0.2 ml plasma samples Pracision is measured by intraday and intarday coefficients o f variation, which are less than 10%. This method is currently being used for pharmacokinetic studies of methoclopramide.  相似文献   

15.
Abstract

A high performance liquid chromatographic [HPLC] method that involves the use of a silica gel column and an aqueous mobile phase for quantitation of chlorpheniramine in plasma and urine is presented. Alkalinized samples are cleaned by extraction with pentane [containing 1% CH3CN], and the extraction is followed by evaporating the solvent and reconstituting the residue in a small amount of mobile phase. An aliquot of this solution is analyzed by an HPLC system with an Ultrasphere Si Column, an aqueous mobile phase at pH 7 containing 60% CH3CN and 7.5 mM [NH4]2HPO4, and UV detection at 200 nm. Although the average recovery of extraction is 58% ± SD 10%, the detection limit for the method is 0.7 ng/ml in plasma and 100 ng/ml in urine [s/n = 3] for 0.5 ml samples. The coefficients of variation [CV] on the results of samples run to measure interday and intraday precision and the bias on control samples were all 10% or less. We have used the method in a bioavailability study of a controlled release formulation involving over 1000 samples.  相似文献   

16.
《Analytical letters》2012,45(7-8):539-550
Abstract

A sensitive, rapid, and specific high pressure liquid chromatographic (HPLC) assay was developed for the determination of salicylic (SA) and salicyluric (SU) acids in plasma and urine. The compounds are extracted into ethyl ether at acid pH, evaporated, and reconstituted prior to instrumental separation. Overall recovery of both compounds is 90 ± 5%, and the sensitivity limits are 150 ng of SU and 300 ng SA per ml of biological fluid. The assay was used for the determination of both compounds in plasma and urine of man following oral doses of 40 mg/kg of sodium salicylate.  相似文献   

17.
Abstract

A high performance liquid chromatographic method for quantitating pentamidine in plasma has been developed. Sample clean-up involved precipitating plasma with acetonitrile containing the internal standard, hexamidine. The supernatant was passed through a C8 Bond Elut column and eluted with a methanolic solution of sodium 1-heptanesulfonate. The eluate was then analyzed on an Altex C8 column with a mobile phase consisting of 45% CH8CN, 0.02% detramethylammonium chloride and 0.1% H3PO4. Using fluorescence detection (EX: 275 nm and EM: 340 nm), the detection limit was 1.25 ng/ml for 0.5 ml of plasma. The coefficients of variation for interday and intraday were around 10%.  相似文献   

18.
Abstract

Isocratic high-performance liquid chromatographic assay of pindolol with use of a microbore column was developed. the sample preparation involves extraction of alkalized plasma into ether and back extraction into 0.05 N H2SO4. Metoprolol was used as the internal standard. Chromatographic separation is performed on a microbore C18 (5 μm) column using acetonitrile-disodium hydrogenphosphate buffer (37:63) containing 20 mM sodium dodecyl sulfate as the mobile phase. the detection is achieved by using a fluorescence detector operated at the excitation and emission wavelengths of 260 and 310 nm, respectively. Acceptable reproducibility and accuracy data are presented over the concentration range normally encountered in human plasma samples. the lower detection limit is 2.5 ng/ml. This sensitivity has been found to be adequate for routine analysis of pindolol in human plasma samples, making the method applicable to pharmacokinetic studies and clinical trials.  相似文献   

19.
Abstract

A selective and sensitive HPLC method was developed for the analysis of ketoprofen in human plasma. The assay involves an extraction of the drug and the internal standard (piroxicam) into diethyl ether from acidified plasma and then back-extracted into a small volume of alkaline aqueous solution before injection onto the HPLC column. A microbore column (2 mm I.D. × 10 cm) packed with a C18 reversed-phase material (5 pm ODS Hypersil) was used. The chromatographic separation was accomplished with a mobile phase comprising a mixture of acetonitrile-methanol-water (15 :20 : 65, v/v) containing 10 mM Na2HP04 buffer, pH 4. The mobile phase was pumped at a flow rate of 0.5 dmin. The eluant was monitored at 258 nm. With this procedure coefficients of variation were less than 10%. The detectionlimit was 0.05 μg/ml (i.e., 50 ng/ml) of plasma. The highly sensitive nature of this method was applied successfully to the dewmination of ketoprofen in human plasma for phmacokinetic studies.  相似文献   

20.
Abstract

A rapid, sensitive and simple to operate HPLC method for the simultaneous determination of carbamazepine, carbamazepine 10,11-epoxide and 10,11-dihydro-10,11-trans-dihydroxycarbamazepine in plasma is described. The drug and its metabolites are extracted from plasma using commercially available reversed-phase octadecylsilane bonded-silica columns (Bond Elut C18, 2.8 ml capacity). Separation was achieved by reversed-phase chromatography, using a mobile phase consisting of acetonitrile - methanol - water (19:37:44) at a flow-rate of 1.8 ml/min in conjunction with a Waters Assoc. Nova-Pak C18 column. The analytical column, in Radial-Pak cartridge form, was used in combination with a Waters Assoc. Z-module RCSS and protected by a Waters Assoc. Guard-Pak precolumn module containing a Guard-Pak μBondapak C18 insert. Using ultraviolet detection at 214 nm, levels in the region of 50–100 ng/ml for CBZ and its metabolites can be measured with only 250 μl of plasma. The method has been used to determine steady-state concentrations of the drug and its metabolites in paediatric patients.  相似文献   