首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract

2,3,4,6-Tetra-O-acetyl-D-glucopyranose (1) was successfully transformed to an anomeric mixture of 2,3,4,6-tetra-O-acetyl-1-O-(methylthio)thiocarbonyl-D-glucopyranose (2) by liquid - liquid and solid - liquid phase transfer methods. Similar anomeric free sugar derivatives bearing acetyl or benzoyl protective groups were also smoothly converted to the corresponding 1-O-(methylthio)thiocarbonyl derivatives. Thermal rearrangement of 1-O-(methylthio)thiocarbonylfuranose derivatives proceeded well to give 1-S-methylthiocarbonyl-1-thiofuranose derivatives.  相似文献   

2.
《Analytical letters》2012,45(10):1813-1823
Abstract

A reversed phase high-performance liquid chromatographic method was developed for the determination of atenolol in four oral 100 mg atenolol preparations.

An aliquot of the sample is dissolved in a mobile phase consisting of 0.0612 M potassium hydrogen phosphate - isopropanol-tetrahydrofuran (84:10:6) v/v). The pH was adjusted to 6.7 with phosphate buffer. Nicotinamide was used as internal standard and chromatographed on a Pinkerton column ISRP (GFF-S5–80) 5 μm, 150 × 4.6 mm i.d. The applied column is convenient for the assay at least 90 samples of atenolol without degrading column performance. The detection was performed at 272 nm. The retention time for atenolol was 5.07 min.

The proposed HPLC method was found to be suitable for the rapid and precise routine analysis of atenolol in tablets.  相似文献   

3.
The characteristics of host-guest complexation between tetrabutyl ether derivatives of p-sulfonatocalix[4]arene (SC4Bu) and methiocarb [3,5-dimethyl-4-(methylthio) phenyl methylcarbamate] were investigated by fluorescence spectrometry. Upon addition of methiocarb, the fluorescence intensity of SC4Bu was quenched regularly and a slight red shift was observed for the maximum emission peak. These results indicated that the SC4Bu-methiocarb complex was formed a 1:1 mole ratio. An association constant of 1.67×10(4) L mol(-1) was calculated by applying a deduced equation. The interaction mechanism of the inclusion complex was discussed. Based on the results, a novel spectrofluorimetric method was described for the determination of methiocarb with a detection limit at 0.05 μg mL(-1). This method is very simple and shows high sensitivity and selectivity. Moreover, the proposed method was successfully applied to the determination of methiocarb in water samples.  相似文献   

4.
Abstract

A simple and rapid reversed-phase high-performance liquid chromatographic procedure is described for the determination of nicotine in liquid formulations. Samples are diluted with methanol, and naphthalene is added as the internal standard. Peak height ratios obtained from injections of standard and sample filtrates are used for quanti-tation. An eluting solvent of 0.05M (NH4)2 HPO4 (pH 7.5) -methanol (40/60, v/v) at a flow of 2 mL/min gives retention times of 3.13 and 6.88 min respectively for nicotine and naphthalene. Sample analysis can be completed in approximately one hour by the method described as compared to 1.5 days required by the Official AOAC gravimetric method (6.176–6.177).  相似文献   

5.
《Analytical letters》2012,45(10):1833-1843
Abstract

A simple and rapid liquid chromatographic assay method using a fluorescence detector for quantitation of dihydroergotamine in plasma without extraction was developed. After precipitating the protein with acetonitrile, the supernatant liquid was directly injected for analysis. Chromatographic separation was achieved on C18 reversed phase column and the mobile phase was the isocratic mixture of methanol, acetonitrile and glycine buffer (0.5:3.5:6.0). With this eluting solvent the drug and its internal standard were well separated from the interference of the plasma sample. The average recovery of dihydroergotamine from 6 replicate samples of different concentrations (5-30 ng/ml) were 92.2 ± 3.37%. The minimum amount of dihydroergotamine detectable by this method was 2 ng/ml of sample.  相似文献   

6.
Abstract

A method is described for a one step acetonitrile precipitation of serum or plasma and subsequent analysis of pentobarbital by reverse phase HPLC. The results of using two internal standards, N,N-Diethyl-m-toluamide and 5-(p-Methylphenyl)-5-phenylhydantoin are compared. Internal standard is added to serum (as little as 25 μL) and vortex-mixed with acetonitrile followed by centrifugation. An aliquote of the supernatant is analyzed on a C18 reverse phase column eluted with metanol/0.05 M (NH4)2HPO4, pH 8/water (55/20/25, v/v/v). The effluent is monitored at 220 nm.  相似文献   

7.
Taking into account previously obtained biological results on some polyheterocyclic compounds (containing different heteroatoms) and in particular on several 8-amino-5-isopropyl-2,2-dimethyl-10-(methylthio)-1,4-dihydro-2H-pyrano[4’’,3’’:4’,5’]pyrido[3’,2’:4,5]thieno[3,2-d]pyrimidines Ia-v we have carried out the synthesis of twentyone 8-amino-5-isobutyl-2,2-dimethyl-10-(methylthio)-1,4-dihydro-2H-pyrano[4’’,3’’:4’,5’]pyrido[3’,2’:4,5]thieno[3,2-d]pyrimidines 6. Therefore we have slightly modified the structure of the previously studied I introducing at C-5 an isobutyl group instead of the previously examined isopropyl ones in order to see if this variation (changing a little the lipophilicity) will affect the biological activity. Furthermore thieno[3,2-d]pyrimidine-8-thione 7 and their S-alkylated 8 were synthesized. Finally by alkylation of 5-isobutyl-2,2-dimethyl-10-thioxo-1,4,10,11-tetrahydro-2H-pyrano[4'',3'':4',5']pyrido[3',2':4,5]thieno[3,2-d]pyrimidin-8(9H)-one 3 with alkyl dichlorides (bifunctional reagents) we realized the cyclization of a thiazole or thiazine ring on the [b] side of the pyrimidine ring with formation of the new condensed pentaheterocyclic systems: pyrano[4'',3'':4',5']pyrido[3',2':4,5]thieno[3,2-d][1,3]thiazolo[3,2-a]pyrimidin-8-one 11 and pyrano[4''',3''':4'',5'']pyrido[3'',2'':4',5']thieno[3',2':4,5]pyrimido[2,1-b][1,3]thiazin-8-one 12. It was found that some of the synthesized compounds showed interesting antimicrobial activity (by agar diffusion method) against some gram-positive and gram-negative bacilli strains.  相似文献   

8.
Abstract

An easy to perform, specific, reproducible and sensitive high performance liquid chromatographic (HPLC) method to measure pyridostigmine concentration in human plasma was developed and validated. Sample clean-up consists of ion-pair extraction into dichloromethane in the presence of neostigmine as internal standard, followed by back extraction into an aqueous phase. Mean recovery of 110% (with a standard deviation of 10%) was determined for concentrations of 5 – 100 ng/ml. Chromatography on a 125·4 mm CN-propyl column using a mobile phase composed of 10% acetonitrile in 3.5×10?4M NaH2PO4 and UV detection at 270 nm, yields clean chromatograms without any interferences from endogenous plasma components. Using 1 ml plasma samples the method has a limit of detection (LD) of 3 ng/ml, with %CV (precision) and bias (accuracy) ≥ 10% for concentrations in the range of 0–100 ng/ml. The method is being used in human pharmacokinetic studies of oral dosage forms of pyridostigmine.  相似文献   

9.
《Analytical letters》2012,45(8):601-613
Abstract

A rapid and selective method using high performance liquid chromatography with electrochemical detection is described for the determination of apomorphine in tablets. Tablet mixes were dissolved in a standard volume of mobile phase containing the internal standard, N-n-propylnorapomorphine. Separation was achieved on a μ-phenyl column using methanol-acetonitrile-0.05M KH2PO4 (5:15:80) as mobile phase. The eluted compounds were detected with a sandwich-type electrochemical detector employing a glassy carbon working electrode and operated at 0.5V. Satisfactory accuracy and precision were obtained during analyses of tablets containing apomorphine.  相似文献   

10.
《Analytical letters》2012,45(4):737-746
Abstract

A rapid, sensitive, and selective high‐performance liquid chromatography‐tandem mass spectrometric method (HPLC‐MS‐MS) for the determination of coumatetralyl in human serum using warfarin as an internal standard has been developed and validated. Coumatetralyl and the internal standard were extracted from the human serum samples by liquid‐liquid extraction with ethyl acetate, followed by separation on a XDB C18 reversed‐phase column (150 mm×2.1 mm i.d., 5 µm) using a mobile phase consisting of acetic acid‐ammonium acetate (5 mmol/L, pH=4.5)/methanol (20:80, v/v) at a constant flow rate of 0.40 mL/min. Coumatetralyl and the internal standard were ionized by negative ion pneumatically assisted electrospray and detected in the multiple‐reaction monitoring mode using precursor→product ion combinations at m/z 291→247 and 307→161, respectively. The calibration curve was linear (r2=0.9945) in the concentration range of 0.5~100.0 ng/mL, with a lower limit of quantification of 0.5 ng/mL in human serum. Intra‐ and inter‐day relative standard deviations were less than 6.3 and 11.0%, respectively. The mean extraction recovery was 87.9% for coumatetralyl and 90.1% for the internal standard. This method is found to be able to determine trace coumatetralyl in human serum and can be used for the diagnosis of poisoned human beings.  相似文献   

11.
A high-performance liquid chromatographic (HPLC) procedure was developed to separate all-trans-, 13-cis-, 11-cis- and 9-cis-retinal isomers. Two reversed-phase Vydac C18 columns in series were used with an isocratic solvent system of 0.1 M ammonium acetate-acetonitrile (40:60, v/v) as mobile phase and all-trans-9-(4-methoxy-2,3,6-trimethylphenyl)-3,7-dimethyl-2,4,6,8-no natetraene-1-ol (TMMP) as internal standard. Prior to HPLC, the retinal isomers were efficiently extracted in their original isomeric conformation using dichloromethane-n-hexane in the presence of formaldehyde. This technique is suitable for the assay of 11-cis- and all-trans-retinal isomers in retina.  相似文献   

12.
We have observed unusual thermal rearrangements of N-cyclohexylidene-4-methyl-1-(methylthio)penta-1,3-dien-1-amine to 4,4-dimethyl-2-(methylthio)-3,3a,4,4a,5,6,7,8-octahydrobenzo[4,1]cyclobuta-[1,2-b]pyrrole and 1-cyclohexyl-5-methylpyridine-2(1H)-thione.  相似文献   

13.
《Analytical letters》2012,45(17):2083-2089
Abstract

A high-performance liquid chromatographic procedure for the determination of pirenzepine dihydrochloride as a bulk material and in its tablet dosage form (GastrozepinR) is presented. Normal phase liquid chromatography has been performed on a Micro-pack Si-10 column using ammonium hydroxide (28–30% NH3) in methanol (0.75: 99.25% v/v) as mobile phase at a flow rate of 2 ml/min. Clobazam has been used as internal standard with retention times of 1.9 and 2.8 minutes for clobazam and pirenzepine dihydrochloride, respectively at 254 nm. Analytical calibration yields a linear relationship between 5 and 25 μg/ml, with correlation coefficient of 0.999. Tablets each labelled to contain 25 mg pirenzepine dihydrochloride give mean percentage found of 99.98 ± 0.4. A plot of logarithm of concentration against time for a solution in 6 N hydrochloric acid gives a straight line with a slope of - 0.197 day?1. The proposed method is, therefore, a stability indicating method.  相似文献   

14.
An improved high-performance liquid chromatographic method with UV detection at 313 nm has been developed for quantitation of ranitidine in 100 microliter of rat plasma over the range 25 to 1000 ng/ml. To each sample were added the internal standard (metiamide) and 2 M NaOH. After dichloromethane extraction, the nitrogen-dried extracts were reconstituted in the mobile phase of 0.01 M phosphate buffer-triethylamine-methanol-water (530:5:390:75 v/v). Chromatography on mu Bondapak C18 with quantitation by peak height ratios showed an analyte recovery of 97%; a limit of detection of 10 ng/ml; a precision of 1-10% and an accuracy of 1-5%. About 90 samples can be processed in 24 h.  相似文献   

15.
A method is described for the determination of oxantel and pyrantel pamoate in proprietary broad spectrum anthelmintic tablets. Quantitation is performed by using an octyl Spherisorb column with a mobile phase consisting of acetonitrile and water modified with butylamine. Carbaryl-(1-naphthyl methylcarbamate) is used as internal standard.  相似文献   

16.
Abstract

An isocratic high-performance liquid chromatography method for the determination of tetracycline and its related compounds is described. The method uses a reverse phase (C18) column, a modified acetonitrile/water mobile phase, and banzoic acid as the internal standard. Elution of all compounds of interest is complete within seven minutes. Results are presented for thirteen commercial capsule formulations and are compared with results by microbiological assay and thin-layer chromatographic methods.  相似文献   

17.
《Analytical letters》2012,45(7):1125-1131
Abstract

A simple and sensitive method has been developed for the determination of disopyramide employing reverse phase high performance liquid chromatography with UV detection. p-Chlorodisopyramide was used as an internal standard. The retention times of disopyramide and the internal standard at an elution rate of 1.8 ml/min were 6.28 and 8.78 min, respectively.  相似文献   

18.
Abstract

An expedient, eco-friendly and efficient procedure for the synthesis of novel 2-amino-3-nitro-4H-chromene derivatives has been developed through the reaction of various 2-hydroxybenzaldehydes and (E)-N-methyl-1-(methylthio)-2-nitroethenamine in the presence of the basic ionic liquid catalyst (choline hydroxide (ChOH)) at room temperature an aqueous medium. The advantageous of this method is a biodegradable and recyclable catalyst, mild, environmentally friendly and high products yields (83-96%) in short reaction times.  相似文献   

19.
Abstract

A simple and rapid reversed-phase liquid chromatographic method for the determination of alprazolam and a-hydroxyalprazolam in plasma is described. Flunictrazepam was used as internal standard. Plasma samples were buffered with sodium borate and extracted with dichloromethane /n-pentane 4:6 v/v for 60 sec on a vortex apparatus. Extraction solvent was evaporated to dryness and extraction residues were reconstituted in the mobile phase. Samples were chromatographed on a 5μ Lichrospher RP-18 column (25cm × 4mm i. d) using acetonitrile/water 40:60 v/v as the mobile phase. The column effluent was monitored at 230nm. The lower limit of detection was 1ng/ml for alprazolam and a-hydroxyalprazolam while the lower limit of quantification was 2ng/ml for both compounds. Peak height and plasma  相似文献   

20.
Abstract

A simple and rapid reverse-phase liquid chromatography method is described for quantification of quazepam in tablets. Quazepam is extracted with methanol. An aliquot (10 ul) of the diluted methanolic extract was injected into the chromatograph. Chromatographic separations were made on a Adsorbosphere C8 column (10 cm × 4.6 mm I. D.). Chromatograph was operated at ambient temperature with a mobile phase of 0.002 M phophate buffer (pH 4.0)-methanol (40:60) using a flow rate of 1.5 ml/min. Effluents were monitored at 265 nm. Retention times for diazepam (internal standard) and quazepam were 5.41 min and 8.67 min, respectively. Excellent day-to-day reproducibility of the slope of the standard curve and recovery data were obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号