首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Abstract

A simple, rapid and specific HPLC method has been developed to determine acetazolamide concentrations in human plasma. The assay procedure requires only 250 μl of sample with direct injection of the organic supernatant after protein precipitation with acetonitrile. Chlorothiazide was used as an internal standard. A reversed-phase C18 μBondapak column was employed for the chromatographic separation. The eluent was monitored at 265 nm using a UV variable wavelength detector. The retention times for acetazolamide (ACZ) and chlorothiazide (CTZ) were 6 and 8 min respectively. A linear relationship (r).995) was obtained over the 1-20 μg/ml concentration range. The limit of sensitivity for ACZ was 0.5 μg/ml, with greater than 85% recovery of ACZ and internal standard. The method was applied to human plasma samples obtained after administration of a 250 mg acetazolamide tablet.  相似文献   

2.
《Analytical letters》2012,45(10):1833-1843
Abstract

A simple and rapid liquid chromatographic assay method using a fluorescence detector for quantitation of dihydroergotamine in plasma without extraction was developed. After precipitating the protein with acetonitrile, the supernatant liquid was directly injected for analysis. Chromatographic separation was achieved on C18 reversed phase column and the mobile phase was the isocratic mixture of methanol, acetonitrile and glycine buffer (0.5:3.5:6.0). With this eluting solvent the drug and its internal standard were well separated from the interference of the plasma sample. The average recovery of dihydroergotamine from 6 replicate samples of different concentrations (5-30 ng/ml) were 92.2 ± 3.37%. The minimum amount of dihydroergotamine detectable by this method was 2 ng/ml of sample.  相似文献   

3.
Abstract

Methods for the quantitative determination of NAPROXEN and its main metabolite in plasma and urine are described. The separation is based on reversed phase liquid chromatography with LiChrosorb RP 8 (5 μm) as the support and methanol/phosphate buffer pH 7 as mobile phase, in some cases with addition of tetrabutyl ammonium ion as ion-pairing agent to improve the chromatographic selectivity. With UV-detector and a simple filter fluorometer an extraction-evaporation procedure is used for both plasma and urine determinations, while the high selectivity and sensitivity of a sophisticated fluorescence detector permits the direct injection of diluted samples on to the column. Use of an internal standard improves the within-run precision (srel%), which for plasma determinations of NAPROXEN are - with UV-detection, 0.2 – 1.7% (range 10 – 40 μg/ml), with filter fluorometer, 2.4 – 5.9% (range 12 – 58 μg/ml), and with fluorescence detector, 0.8 – 4.1% (range 5 – 20 μg/ml).  相似文献   

4.
《Analytical letters》2012,45(6):1125-1135
Abstract

A HPLC method has been developed to determine the concentrations of SAZ-VII-23 (3-benzoyl-7-isopropyl-3,7-diazabicyclo[3.3.1]nonane HClO4), a novel antiarrhythmic agent, in dog plasma and urine. Plasma treated with acetonitrile and alkalinized urine were extracted with chloroform- propanol (9:1). An aliquot was injected on to HPLC system using a C6 reversed-phase column and acetonitrile-methanol-37.5 mM phosphate buffer, pH 6.8 (28.5:28.5:43 v/v) containing 4.0 mM triethylamine as mobile phase. Detection wavelength was 255 nm. The linear range were 0.04–8 μg/ml, and the lower limit of quantitation was 0.04 μg/ml in plasma and urine, respectively. The method was applied to determine plasma and urine concentrations and preliminary pharmacokinetic profiles of SAZ-VII-23 in a dog.  相似文献   

5.
Abstract

A rapid, sensitive, and specific determination of enoxacin and its principal metabolite, oxo-enoxacin, in plasma and urine is described. the method, which employs the structurally related compound ciprof loxac in as internal standard, involves a protein precipitation step for plasma and solid-phase extraction for urine. Liquid chromatographic analysis is carried out on a C-18 bonded silica column; the mobile phase consists of 0.1 M citric-acid/acetonitrile employing ammonium perchlorate and tetrabutyl-ammonium hydroxide as ion-pairing agents. Quantitation is performed by UV-detection at 340 nm.

The analytical method was validated by examining the performance characteristics specificity, linearity, precision, accuracy, sensitivity, and recovery. Enoxacin calibration curves were linear between 0.02 and 3.2 μg/ml of plasma and from 0.5 to 125 μg/ml of urine. Limits of quantitation in plasma and urine were 0.01 and 0.5 μg/ml, respectively. For oxo-enoxacin, linear of calibration curves were obtained i n the range 0.05 to 1.6 μg/ml (plasma) and 1 to 50 μg/ml (urine); the respective quantitation limits were approximately 0.02 and 1 μg/ml.

The present assay procedure has been applied to monitoring plasma and urine concentrations in several pharmacokinetic studies in humans and different animal species.  相似文献   

6.
Abstract

A rapid, sensitive and simple to operate HPLC method for the simultaneous determination of carbamazepine, carbamazepine 10,11-epoxide and 10,11-dihydro-10,11-trans-dihydroxycarbamazepine in plasma is described. The drug and its metabolites are extracted from plasma using commercially available reversed-phase octadecylsilane bonded-silica columns (Bond Elut C18, 2.8 ml capacity). Separation was achieved by reversed-phase chromatography, using a mobile phase consisting of acetonitrile - methanol - water (19:37:44) at a flow-rate of 1.8 ml/min in conjunction with a Waters Assoc. Nova-Pak C18 column. The analytical column, in Radial-Pak cartridge form, was used in combination with a Waters Assoc. Z-module RCSS and protected by a Waters Assoc. Guard-Pak precolumn module containing a Guard-Pak μBondapak C18 insert. Using ultraviolet detection at 214 nm, levels in the region of 50–100 ng/ml for CBZ and its metabolites can be measured with only 250 μl of plasma. The method has been used to determine steady-state concentrations of the drug and its metabolites in paediatric patients.  相似文献   

7.
Summary A procedure for the rapid, quantitative isolation of amiodarone and its main metabolite (desethylamiodarone) from plasma with SEP-PAK silica cartridges is described together with a sensitive high performance liquid chromatographic assay for the quantitative determination of the drugs.The recovery of amiodarone and its metabolite was greater than 80% over an investigated range of 0.1–5g/ml of plasma and the limit of quantitation by the assay was 50 ng/ml of plasma.The column extraction of amiodarone and its metabolite coupled with the chromatographic versatility of the method make it suited for either detailed pharmacokinetic studies and routine plasma analysis of amiodarone.  相似文献   

8.
《Analytical letters》2012,45(13):1063-1071
Abstract

A rapid, specific and sensitive reversed-phase liquid chromatographic (LC) assay for the quantitative determination of indomethacin in serum without extraction was developed. Chromatographic separation using flunixin meglumine as the internal standard was achieved on octadecylsilane-coated particles with a mobile phase of 0.15 M acetate buffer pH 3.0 (50% v/v), acetonitrile (30% v/v) and methanol (20% v/v). The recovery of indomethacin from serum samples in the concentration range of 0.1-25 μg/ml was 95.5 ± 5.8% and as little as 100 ng/ml of indomethacin in serum samples can be quantitated by this procedure. A serum level versus time profile of dog with intravenously administered indomethacin demonstrated the applicability of the assay.  相似文献   

9.
《Analytical letters》2012,45(11):1345-1355
Abstract

A sensitive and reliable liquid chromatographic assay procedure for the quantitation of oxamniquine in plasma or urine was developed. Chromatographic separation was achieved on a reversed-phase phenyl colum using U.V. Detection at 254 nm. The eluting solvent was the mixture of 0.05 M acetate buffer pH 5 and acetonitrile (3:7). With this mobile phase the drug and its external standard were well separated from the interference of the blank samples. The average recovery of oxamniquine from 3 or more replicate dog plasma samples of different concentration (0.125 ? 4.00 μg/ml) was 95.5% and its coefficient of variation was 4.17%. The reproducibility of the assay was confirmed by the analysis of variance test for the slopes of the three standard plots obtained from plasma samples at three different occasions (F=4.2, p > 0.01). The detection limit for plasma samples was approximately 20 ng/ml. The method was applied to measure the plasma level vs, time profile of this drug following a single bolus intravenous dose of 16 mg/kg to a dog.  相似文献   

10.
Abstract

A simple and sensitive high-performance liquid chromatographic method for quantitation of clopamide in human plasma has been developed. the assay uses a reversed-phase C18 microbore column (2 mm I.D. × 100 mm) packed with 5 μm ODS Hypersil. the chromatographic separation was achieved by using an isocratic mobile phase comprising acetonitrile-10 mM phosphate buffer pH 4 (17:83, v/v) at a flow rate of 0.5 ml/min. the eluant was monitored by a UV detector operating at 241 nm. the assay was based on an organic extraction before chromatographic separation. to 1 ml plasma sample, 100 μl of the internal standard, methylparaben (300 ng/ml), and 8 ml of diethyl ether were added. the samples were shaken and centrifuged, the organic layer was then transferred to a tapered centrifuge tube and evaporated to dryness. the residue was reconstituted and injected onto the HPLC column. the inter-and intra-assay coefficients of variation were found to be less than 10%. the lowest limit of detection for clopamide in plasma was 5 ng/ml. the method is sensitive, specific and allows for routine analysis in the pharmacokinetic studies.  相似文献   

11.
Abstract

An automated HPLC method for the quantitative determination of the anti-inflammatory compound CGS 5391B in blood plasma was devised and tested. The method provides quantitation in the concentration range of 1 to 200 μg/ml of drug in plasma, with an average recovery of 96.6±6.0%.  相似文献   

12.
Abstract

A high performance liquid chromatographic (HPLC) technique has been developed for the determination of bupropion hydrocloride (Bup) in human plasma, using a reversed-phase method, with UV detection at 250 nm.

The internal standard 5-(P-methylphenyl)-5-phenylhydantoin (MPPH), was used as an aid to quantitation. The plasma was deprotemized with acetonitrile and the clear supernatant was directly injected in the chromatographic system. The lower limit of quantitation was 5.0 ng/ml using only 100 μl of plasma sample.

Linear regression analysis for the calibration plots obtained on five different days over a two-week period for the the two ranges used (10–250 ng/ml and 250–2000 ng/ml) in plasma indicated excellent linearity and reproducibility. The mean recovery of spiked Bup in plasma samples over the concentrations studied was found 96.5 ± 3.14%.

The method revealed that more than 30% of Bup was lost when the supernatant was stored at room temperature for 24 hrs.  相似文献   

13.
Abstract

A rapid, simple and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of antipyrine in small volume (50 μl) of plasma samples. Aminopyrine was employed as the internal standard. The sample preparation is a direct plasma protein precipitation procedure so is less tedious and rapid. The assay employs a column packed with a C18 reversed-phase material (5 μm Nucleosil) with an isocratic mixture of acetonitrile and water (25:75, v/v) as the mobile phase. The eluant was detected at 254 nm. The assay achieves the level of sensitivity (0.5 μg/ml) and accuracy required to obtain meaningful data about the single-dose pharmacokinetics of antipyrine in guinea pig and rat. The method gave high reproducibility with coefficients of variation less than 5%.  相似文献   

14.
Abstract

A reversed-phase high pressure liquid chromatographic procedure has been developed for the quantitation of the concentration of six different tricyclic antidepressants in the plasma of patients undergoing routine drug therapy. Plasma samples were extracted into a 97:3 hexane:isoamyl alcohol solution and then extracted back into dilute acid. A Supelcosil C-8 column with 5 micron packing was employed in combination with an acetonitrile/ phosphate buffer/diethylamine mobile phase. At an optimized mobile phase pH of 7.22, baseline separation of all six tricyclic antidepressants plus the internal standard was achieved within 8 minutes. UV detection at 254 nm resulted in limits of detection of 2.5 μg/L for each drug. The potential interferences from 13 different benzodiazepines and neuroleptics was investigated. Five of the 13 parent drugs and three metabolites were found to interfere with this tricyclic antidepressant assay.  相似文献   

15.
《Analytical letters》2012,45(17-18):1433-1447
Abstract

A simple, specific, rapid and sensitive method for the analysis of mecillinam in plasma and urine using high pressure liquid chromatography is described. The assay is performed by direct injection of a plasma protein free supernatant or a dilution of urine. A μBondapak phenyl column with an eluting solvent of 16% CH3CN-0.2% H3PO4 was used, with UV detection of the effluent at 220 nm. Desacetyl-cephalothin was used as the internal standard and quantitation was based on peak height ratio of mecillinam to that of the internal standard. The lowest concentration detectable without extraction was 0.25 μg/ml for plasma and 8.9 μg/ml for urine. No interference from plasma and urine was noted.  相似文献   

16.
Abstract

Meclofenamic acid is extracted to dichloromethane together with the internal standard diclofenac sodium. After evaporation of the organic solvent the residue is dissolved in the chromatographic eluent and analyzed by liquid chromatography. The acids are separated on a column packed with Spherisorb ODS with methanol - phosphate buffer as the eluent and detected at 280 nm. A possible metabolite of meclofenamic acid was also detected in the chromatograms. The detection limit for meclofenamic acid in plasma was 0.361 μmol/L (0.107 μg/ml) for 1.5 ml sample size. The conditions of quantitative extraction of meclofenamic acid and diclofenac to dichloromethane are given.  相似文献   

17.
《Analytical letters》2012,45(10):1611-1634
Abstract

A selective and sensitive reversed-phase liquid chromatographic method with electrochemical detection for the analysis of doxorubicin, daunorubicin and some of their metabolites in plasma is reported. A mobile phase consisting of acetonitrile-phosphate buffer solution-tetrahydrofuran (25–71,5–3,5) flowing at 1 ml/min through a Lichrocart RP 18 column was employed. The influence of various parameters on the separation (solvent composition, pH, tetrahydrofuran content) has been examined. An extraction of anthracyclines from plasma was performed using chloroform-ethanol mixture (4: 1) with high extraction efficiency; reproducible results were attained by working with a 1 M phosphate buffer which ensured a real buffering of the plasma samples. The sensitivity of amperometric detection makes this method suitable for analyzing small amounts of the parent drugs and their metabolites. The precision was better than 4% in the range 0.2 to 5 μg/ml plasma.  相似文献   

18.
Abstract

A new procedure of pre-concentration on Tenax GC followed by high performance liquid chromatography analysis has been developed for the quantitative determination of acenocoumarin in human plasma. The recovery of acenocoumarin was greater than 90% over a concentration range of 0.10 to 1.00 μg/ml and the limit of quantitation by the assay was 10 ng/ml of plasma. This method allows quantitative determinations in patients under acenocoumarin therapy and can be used as a routine clinical monitoring.  相似文献   

19.
Abstract

A simplified method is described for extracting and purifying 25-hydroxycholecalciferol and 25-hydroxyergocalciferol from serum for quantitation by high-pressure liquid chromatography. The method involves extracting and purifying these metabolites from serum (1–10 ml) with a reverse-phase octadecylsilane bonded silica cartridge (Sep-Pak C18). This method is faster than a previously described method involving extraction with dichloromethane and purification by Sephadex LH-20 chromatography. The correlation between the two methods was excellent (r2 = 0.96, p≤0.0001). The coefficient of variation for the new method is 4.3%. The new method allows measurement of 25-hydroxyergocalciferol from human serum since both 25-hydroxycholecalciferol and 25-hydroxyergocalciferol are extracted equally. This allows the use of [3H] 25-hydroxycholecalciferol to monitor the recovery of both the D2 and the D3 forms of the metabolite.  相似文献   

20.
Abstract

Ibuprofen is a non-steroidal anti-inflammatory drug, widely used in arthritis and other disorders. We describe a high pressure liquid chromatographic (HPLC) method for the analysis of ibuprofen in plasma, using an automated solid phase extraction technique (the Varian AASPR). In this method ibuprofen was extracted from 0.5 ml of plasma by application to a C2 extraction cartridge followed by “on line” elution with the HPLC mobile phase (55% acetonitrile / 45% 0.02 H phosphate buffer; pH 3.0), at a flow rate of 1.5 ml/min. The analytical column was a Nucleosil C18 column and the fluorescence detector was set at 253 nm (excitation wavelength) and 300 nm (emission wavelength). Chromatography was complete in less than 10 mins and the limit of detection was 1.3 /μg/ml. The method is linear through the range of 1.0 to 100.0 /μg/ml with a mean correlation coefficient of 0.9964. Absolute recovery of ibuprofen from the spiked plasma samples ranged from 77.8% to 86.5%. The method was shown to be precise within 11% C.V. and accurate to within 8% over the concentration range studied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号