首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary A reversed-phase HPLC method has been developed suitable for a reliable quality control of pharmaceutical and dietary formulations containing the synthetic sweeteners aspartame and saccharin. The proposed method is able to separate acesulfame, aspartame and saccharin, and their impurities such as 5-benzyl-3,6-dioxo-2-piperazineacetic acid (the major degradation product of aspartame) and 4-sulphamoylbenzoic acid,o- andp-toluenesulphonamides (the synthesis impurities of saccharin). A convenient solid-phase extraction (SPE) procedure using C-18 sorbent, was also developed for the determination of potential saccharin impurities.  相似文献   

2.
《Analytical letters》2012,45(17):3195-3207
Abstract

The use of square‐wave voltammetry in conjunction with a cathodically pretreated boron‐doped diamond electrode for the analytical determination of aspartame in dietary products is described. In this determination, the samples were analyzed without previous treatment in a 0.5 mol l?1 H2SO4 solution. A single oxidation peak at a potential of 1.6 V vs. Ag/AgCl (3.0 mol l?1 KCl) with the characteristics of an irreversible reaction was obtained. The analytical curve was linear in the aspartame concentration range 9.9×10?6 to 5.2×10?5 mol l?1 with a detection limit of 2.3×10?7 mol l?1. The relative standard deviation (n=5) obtained was smaller than 0.2% for the 1.0×10?4 mol l?1 aspartame solution. The proposed method was applied with success to the determination of aspartame in several dietary products and the results were similar to those obtained using an HPLC method at 95% confidence level.  相似文献   

3.
《Analytical letters》2012,45(7):1333-1347
Abstract

A multianalyte flow‐through sensor is proposed for the simultaneous determination of aspartame (AS) and acesulfame‐K (AK) in tabletop sweeteners. The procedure is based on the transient retention of AK in the ion exchanger Sephadex DEAE A‐25 placed in the flow‐through cell of a monochannel flow injection analysis (FIA) set‐up using pH 2.70 ortophosphoric acid/sodium dihydrogen phosphate buffer 0.06 M as carrier. In these conditions AS is very weakly retained, which makes it possible to measure the intrinsic ultraviolet (UV) absorbance of first AS and then AK after desorption by the carrier itself. The applicable concentration range, the detection limit, and the relative standard deviation were the following: for AS, from 10 to 100 µg mL?1; 5.65 µg mL?1; 3.4% (at 50 µg mL?1); and for AK, between 40 and 100 µg mL?1; 11.9 µg mL?1 and 1.61% (at 50 µg mL?1). The method was applied and validated satisfactorily for the determination of AS and AK blends in tabletop sweeteners. The results were compared against an HPLC reference method.  相似文献   

4.
Molecularly imprinted polymers selective for aspartame have been prepared using N-[2-ammonium-ethyl-piperazinium) maleimidopropane sulfonate copolymer bearing zwitterionic centres along the backbone via a surface-confined grafting procedure. Aspartame, a dipeptide, is commonly used as an artificial sweetener. Polymerisation on the surface was propagated by means of Michael addition reaction on amino-grafted silica surface. Electrostatic interactions along with complementary H-bonding and other hydrophobic interactions inducing additional synergetic effect between the template (aspartame) and the imprinted surface led to the formation of imprinted sites. The MIP was able to selectively and specifically take up aspartame from aqueous solution and certain pharmaceutical samples quantitatively. Hence, a facile, specific and selective technique using surface-grafted specific molecular contours developed for specific and selective uptake of aspartame in the presence of various interferrants, in different kinds of matrices is presented.  相似文献   

5.
A gelatin membrane with carboxyl esterase and alcohol oxidase was subsequently integrated onto the surface of a graphite epoxy composite electrode (GECE). The developed biosensors showed linearity in the range of 2.5–400 μM for aspartame and 2.5–25 μM for ethanol with response times of 170 and 70 s for each analyte, respectively. The resulting bienzyme biosensor was used for aspartame detection in diet coke samples and ethanol detection in beer and wine samples. From the obtained results, it can be concluded that the developed biosensor is a selective, practical and economic tool for aspartame and ethanol detection in real samples.  相似文献   

6.
反相高效液相色谱法同时测定发酵乳中的蛋白糖和氨基酸   总被引:2,自引:0,他引:2  
张文悦  孙雪雁  佘琼群  张遐耘 《色谱》1998,16(6):539-540
介绍了同时测定发酵乳中蛋白糖和氨基酸的HPLC方法。样品经甲醇除去蛋白,异硫氰酸苯衍生,RP-HPLC法测定。蛋白糖回收率为94.2%~98.7%,精密度以相对标准偏差表示为2.15%~3.74%。  相似文献   

7.
Abstract

Analytical method of diketopiperazine (5-Benzyl-3, 6-dioxo 2 piperazineacetic Acid: DKP), a major degradation product of aspartame (AMP), in soft drinks was developed by means of high performance liquid chromatography (HPLC). A sample was purified using Bond Elut SCX connected to Bond Elut C8 with 20% acetonitrile as the eluent. A Nucleosil 5-C18 column was employed for the HPLC with 10 mM potassium dihydrogenphosphate and acetonitrile (85+15, v/v) adjusted pH to 4.0 as the mobile phase. The calibration curve was rectilinear in the range of 0.5 to 10.0 μg/ml for DKP. The average recoveries were 99.8% and 96.0% for DKP added to soft drinks at the level of 10 μ g/ml and 2.5 μ g/ml, respectively. The DKP was found in six commercial samples in the range of 9.5 to 26.0 μ g/ml.  相似文献   

8.
Aspartame is a widely used sweetener,the long-term safety of which has been controversial ever since it was accepted for human consumption.It is unstable and can produce some harmful degradation products under certain storage conditions.A high-performance liquid chromatography/tandem mass spectrometry method was developed for the simultaneous analysis of aspartame and its four degradation products,including aspartic acid,phenylalanine,aspartyl-phenylalanine and 5-benzyl-3,6-dioxo-2-piperazieacetic acid in water and in diet soft drinks.Aspartame and its four degradation products were quantified by a matrix matched external standard calibration curve with excellent correlation coefficients.The limits of detection were 0.16–5.8 mg/L,which exhibited higher sensitivity than common methods.This method was rapid,sensitive,specific and capable of eliminating matrix interferences.It was also applied to the study of the degradation of aspartame at various pH and temperatures.The results indicated that aspartame was partly degraded under strong acidic or basic conditions and the extent of degradation increased with increasing temperature.  相似文献   

9.
A sensor of aspartame (l-aspartyl-l-phenylalanine methyl ester) is prepared by chemical immobilization of l-aspartase on an ammonia-selective electrode. Semi logarithmic response (E vs. log C) was observed in the 1 × 10?3?1 × 10?2 M range with a slope of ?30 mV/decade. The sensor is stable for more than eight days. The probe is successfully used for the assay of aspartame in commercially available sweeteners.  相似文献   

10.
Procedures have been developed for the preparation of aspartyl containing dipeptides P-L-Asp-AA2 (P=Boc, Cbz and Moz; AA2=Phe-R or Ala-R; R=OH, OBzl and OTMB) using papain as a catalyst. The pH dependent of esterase activity by papain catalyzed hydrolysis have been studied. The papain catalyzing reaction can be reacted in aqueous solution, buffer solution or cosolvent system in a thermodynamically controlled approach. A procedure for the conversion of the artificial sweetner precursor P-Asp-Phe-OH to the aspartame is studied also.  相似文献   

11.
《Analytical letters》2012,45(5):767-778
Abstract

A specific and sensitive high‐performance liquid chromatographic method was developed for the determination of metoclopramide in canine plasma. The procedure involves fast liquid–liquid extraction and analysis on an octadecyl silane (ODS) column. A preliminary pharmacokinetic study was performed by applying the developed method to a single oral administration of metoclopramide (MCP) to a dog. The validation method yielded good results regarding linearity, precision, accuracy, and specificity. The procedure is suitable for separation and quantification of MCP in canine plasma, enough to quantify 0.2 ng/ml when 0.5 ml of plasma is used. This assay procedure might be useful for the pharmacokinetic study of MCP in dogs.  相似文献   

12.
A flow injection analysis (FIA) biosensor system was developed for the determination of the artificial sweetener aspartame (l-aspartyl-l-phenylalanine methyl ester). The system consisted of an enzyme column of pronase immobilized on activated arylamine glass beads and al-amino acid oxidase electrode connected in series. The dipeptide bond of aspartame was cleaved by immobilized pronase to release phenylalanine, which was in turn monitored by the enzyme electrode that usedl-amino acid oxidase, immobilized on a preactivated nylon membrane in combination with an amperometric electrode (platinum vs silver/silver chloride, 700 mV). The response of the FIA biosensor was linear up to 1 mM aspartame with a lower detection limit of 25 μM and had good reproducibility (rsd 0.3%). The FIA biosensor was stable for at least 30 h of continuous use atT r .Each assay takes 4 min giving a sample throughput of 15 h?1 When applied to aspartame in dietary food products the results obtained agreed well with those reported by the product manufacturers.  相似文献   

13.
《Analytical letters》2012,45(8):1567-1575
ABSTRACT.

A rapid first derivative spectrophotometric method for simultaneous determination of two synthetic dyes, erytrosine (E 127) and sunset yellow (E 110), in a mixture is proposed. The procedure does not require any separation step. The method was applied for determining the two compounds in a pharmaceutical syrup. Good linearity, accuracy, precision and selectivity were found, and the method is proposed for routine quality control purposes.  相似文献   

14.
Summary.  A simple and rapid derivative spectrophotometric assay procedure is described for the analysis of caffeine (1), acetaminophen (2), and propyphenazone (3) in tablet formulations. The concentration range of application is 5.0–25.0 μg·cm−3 for 2 and 3 and 1.0–5.0 μg·cm−3 for 1. The method involves the extraction of the drugs from tablets with 0.1 N H2SO4, filtration, appropriate dilution, and measurement of the fourth derivative absorbance values at zero crossing wavelengths of 230.0, 263.2, and 256.6 nm for 1, 2, and 3. As a reference method, a reversed phase HPLC procedure was developed. Commercially available tablets were analyzed; statistical comparison of the results with those obtained from the reference method showed good agreement. The derivative spectrophotometric method has the advantage of being simple, rapid, inexpensive, and easy to perform. Received April 18, 2001. Accepted (revised) June 5, 2001  相似文献   

15.
Abstract

A simple and selective high performance liquid chromatography (HPLC) method has been developed for the quantitation of R-836 (an investigational oral bronchodilator) in human plasma and urine, dog plasma and urine, and rat plasma. The method consists of reversed-phase HPLC with ultraviolet detection. Sample preparation involved a one-step protein precipitation procedure and was performed both manually and by a Zymate robotic system. Precision and accuracy results showed excellent reproducibility; results using the robotic procedure were slightly better than the manual procedure. The robotic procedure was capable of preparing the samples with minimal operator handling.  相似文献   

16.
 A simple and rapid derivative spectrophotometric assay procedure is described for the analysis of caffeine (1), acetaminophen (2), and propyphenazone (3) in tablet formulations. The concentration range of application is 5.0–25.0 μg·cm−3 for 2 and 3 and 1.0–5.0 μg·cm−3 for 1. The method involves the extraction of the drugs from tablets with 0.1 N H2SO4, filtration, appropriate dilution, and measurement of the fourth derivative absorbance values at zero crossing wavelengths of 230.0, 263.2, and 256.6 nm for 1, 2, and 3. As a reference method, a reversed phase HPLC procedure was developed. Commercially available tablets were analyzed; statistical comparison of the results with those obtained from the reference method showed good agreement. The derivative spectrophotometric method has the advantage of being simple, rapid, inexpensive, and easy to perform.  相似文献   

17.
《Analytical letters》2012,45(15):2787-2796
Abstract

The study presents the method for simultaneous determination of selenium and arsenic in human urine by atomic fluorescence spectrometry (AFS). According to the procedure developed, a sample is first digested in the microwave system, then chemically treated in the flow through a hydride generation system, and finally exposed to measurements in a double‐channel atomic fluorescence spectrometer. It has been revealed that selenium and arsenic can be accurately determined with detection limit of 0.13 and 0.16 µg/L and repeatability (RSD) of 1.0 and 1.2%, respectively. The urine samples taken from a control group and from persons subjected to a special diet were analyzed. The obtained results proved that the method developed was capable of controlling reliably even slight changes of both elements in a wide range of their concentrations, and, as such, that it can be recommended to be used for clinical and toxicological purposes.  相似文献   

18.
《Analytical letters》2012,45(6):1163-1179
Abstract

A reverse phase HPLC procedure is described for the determination of chloramphenicol and its hydrolytic product, 2-amino-1-(4-nitrophenyl)-propane-1,3-diol. The method was validated for reproducibility, linearity and recovery for both components. It was successfully applied to monitor post-marketing stability of ten batches of chloramphenicol ophthalmic solutions stored at room temperature. As compared to the BP method using solvent extraction and UV measurements, for the determination of chloramphenicol and its hydrolytic product in chloramphenicol eye drops, the suggested procedure was found to be relatively more accurate, precise and less time-consuming.  相似文献   

19.
《Analytical letters》2012,45(12):1023-1037
Abstract

A simple procedure for the determination of low levels of total cyanide in effluent samples has been developed. After distillation of the cyanide from the sample, as hydrocyanic acid, the cyanide is determined with coulometrically generated iodine using a biamperometric end point detection system. As little as 0.06mg/l total cyanide can be measured using the procedure. The method obviates the need for calibration curves and does not require special reagents.

Silver (I) was determined to be an effective catalyst for the decomposition of bound cyanides in the distillation procedure.  相似文献   

20.
Three stochastic sensors based on nanodiamond (nDP) paste modified with α, β, and γ‐cyclodextrin were designed and characterized for pattern recognition of aspartame, acesulfame K and sodium cyclamate in beverages, ketchup, and biological fluids. The linear concentration ranges obtained for acesulfame K (between 1.00×10?10 mol L?1and 1.00×10?3 mol L?1), for aspartame (between 1.00×10?12 mol L?1 and 1.00×10?3 mol L?1) and for sodium cyclamate (between 4.97×10?12 mol L?1 and 4.97×10?3 mol L?1) allow their assay in biological fluids, beverages and ketchup. The lowest limits of quantification were obtained using the stochastic sensor based on γ‐CD/nDP: for acesulfame K 1.00×10?10 mol L?1, for aspartame 1.00×10?12 mol L?1 and for sodium cyclamate 4.97×10?12 mol L?1. All three stochastic sensors revealed very high values of sensitivities. The proposed method was reliable for qualitative and quantitative assay of aspartame, acesulfame K and sodium cyclamate in beverages, ketchup, and in biological fluids such as urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号