1.
采用矩形前沿分析法对原位聚合的对-羟基苯甲酸印迹整体柱的热力学吸附等温线进行了测定. 印迹整体柱的吸附等温线是分别以乙腈、甲醇、 四氢呋喃和含有体积分数分别为1%, 3%, 5%和7%乙酸的乙腈为流动相以及在以甲醇为流动相时柱温分别为20, 40和50 ℃的条件下测定的. 吸附等温线表明, 印迹整体柱对模板分子的吸附能力比其结构类似物(邻-羟基苯甲酸)的吸附能力强. 用双Langmuir方程对不同条件下得到的实验数据进行拟合, 得到模板分子和邻-羟基苯甲酸在印迹整体柱各种吸附位点上的饱和吸附量和键合常数, 结果表明, 流动相中乙酸含量、有机溶剂的性质和柱温对模板分子容量因子的影响比对邻-羟基苯甲酸的大, 造成印迹聚合物的选择性随条件的变化而发生了明显的改变.  相似文献   

2.
The adsorption isotherms of butyl- and amylbenzene on silica monolithic columns were measured by frontal analysis. The external, internal and total porosities of these columns were determined by inverse size-exclusion chromatography. The adsorption isotherms are concave upward in the entire concentration range investigated. They were fitted to the anti-Langmuir model, an unusual model in liquid-solid and liquid-liquid phase equilibria. Band profiles under overloaded conditions were recorded. They were in good agreement with the profiles calculated using th,e lumped pore diffusion model of chromatography and these adsorption isotherms.  相似文献   

3.
Knowing the adsorption isotherms of the components of a mixture on the chromatographic system used to separate them is necessary for a better understanding of the separation process and for the optimization of the production rate and costs in preparative high-performance liquid chromatography (HPLC). Currently, adsorption isotherms are usually measured by frontal analysis, using conventional analytical columns. Unfortunately, this approach requires relatively large quantities of pure compounds, and hence is expensive, especially in the case of pure enantiomers. In this work, we investigated the possible use of packed micro-bore and capillary HPLC columns for the determination of adsorption isotherms of benzophenone, o-cresol and phenol in reversed-phase systems and of the enantiomers of mandelic acid on a Teicoplanin chiral stationary phase. We found a reasonable agreement between the isotherm coefficients of the model compounds determined on micro-columns and on conventional analytical columns packed with the same material. Both frontal analysis and perturbation techniques could be used for this determination. The consumption of pure compounds needed to determine the isotherms decreases proportionally to the second power of the decrease in the column inner diameter, i.e. 10 times for a micro-bore column (1 mm I.D.) and 100 times for capillary columns (0.32 mm I.D.) with respect to 3.3 mm I.D. conventional columns.  相似文献   

4.
The inverse method of isotherm determination consists in calculating the numerical values of the coefficients of an isotherm model that give a set of chromatographic profiles in best possible agreement with the set of experimental profiles available. This method was applied to determine the adsorption isotherms of the 1-indanol enantiomers on a cellulose tribenzoate chiral stationary phase. Both single-component and competitive isotherms were determined by using no more than one or two overloaded band profiles. The isotherms determined from the overloaded band profiles agreed extremely well with the isotherms determined by frontal analysis. Several isotherm models were used and tested. The best-fit isotherm was selected by means of statistical evaluation of the results. The results show that the adsorption is best characterized with a model describing heterogeneous adsorption with bimodal adsorption energy distribution.  相似文献   

5.
The frontal analysis technique was successfully applied to the determination of the adsorption isotherms of the imprinted polymer monolith prepared by a in-situ synthesis method using caffeic acid as the template, and methacrylic acid, ethyl glycol dimethacrylate and2,2-azobisisobutyronitrile as the functional monomer, cross-linker and initiator, respectively, with tetrahydrofuran-iso-octane (2:1, /) as a porogen. Adsorption isotherms of the monolith were measured at 25, 45 and 60°C using tetrahydrofuran containing 1, 3 and 5% acetic acid as mobile phase, respectively. The adsorption capacity of the monolith for the template was found to be much stronger than the other structurally related compounds. The column temperature significantly affected the adsorption capacity of the monolith. The acetic acid in the mobile phase showed some influence on the adsorption of the template on the stationary phase. The adsorption behavior of the template on the monolith is best described by the Freundlich isotherm. From the best coefficients of the Bi-Langmuir fit, the binding constant and saturation capacities of the molecularly imprinted polymer monolith were obtained.  相似文献   

6.
A simple frontal analysis method has been developed for the reliable measurement of excess adsorption isotherms of an organic component on reversed‐phase adsorbents in a series of programmed concentration steps. In the present method, a peak, which is produced by refractive index change in column eluate, is detected at 589 nm; it represents the elution volume of the boundary. The method is applied to the measurement of the excess adsorption isotherms of organic eluent components from water on commercially available reversed‐phase stationary phases. The results are in good agreement with the previously reported isotherms. We also measure the excess adsorption isotherms of organic eluent components from solutions containing electrolytes. There are not any interference peaks on the elution traces. The method is thus reliably applicable to the evaluation of the excess adsorption of organic eluent components in practical systems.  相似文献   

7.
分子印迹整体柱快速分离烟酰胺及烟酸   总被引:6,自引:0,他引:6  
李志伟  刘树彬  杨更亮  李保芝  陈义 《色谱》2005,23(6):622-625
以药物烟酰胺为模板分子,甲基丙烯酸为功能单体,乙二醇二甲基丙烯酸酯为交联剂,甲苯和正十二醇的混合溶液为致孔剂,采用原位聚合法制备了具有特定识别性能和分离能力的分子印迹聚合物,并将其作为高效液相色谱固定相,实现了模板分子与烟酸在2 min内的快速分离。在规格为50 mm×4.6 mm i.d.色谱柱上,以纯水为流动相(流速为7.0 mL/min)、操作温度为室温的色谱条件下,模板分子与烟酸的分离度达1.8。讨论了流动相中有机溶剂含量、醋酸及碱含量和流速对分离的影响。结果表明,原位聚合法制备的整体分子印迹聚合物在以纯水作流动相时对模板分子与其类似物有快速分离能力,这对于体内药物的分离富集研究具有很好的应用前景。  相似文献   

8.
The adsorption isotherms of acetonitrile, ethanol, 2-propanol, and THF were measured using frontal analysis on six columns packed with octadecyl RP stationary phase. The effect of the bonding density of the end-capped octadecyl bonded phase on the adsorption properties was measured. Adsorption isotherm data were collected from aqueous solutions of the four organic modifiers. The isotherm model for solvent adsorption was selected using two independent parameter estimation methods, the regression analysis and adsorption energy distribution. The fitted isotherm parameters were tested by modeling of overloaded elution bands with the aid of the equilibrium-dispersive model of chromatography. The surface heterogeneity estimations and the effect of the silanol groups on the adsorption of solvents were based on those data.  相似文献   

9.
Single component adsorption and desorption isotherms of phenol were measured on a high-efficiency Kromasil-C18 column (N = 15000 theoretical plates) with pure water as the mobile phase. Adsorption isotherm data were acquired by frontal analysis (FA) for seven plateau concentrations distributed over the whole accessible range of phenol concentration in pure water (5, 10, 15, 20, 25, 40, and 60 g/l). Desorption isotherm data were derived from the corresponding rear boundaries, using frontal analysis by characteristic points (FACP). A strong adsorption hysteresis was observed. The adsorption of phenol is apparently modeled by a S-shaped isotherm of the first kind while the desorption isotherm is described by a convex upward isotherm. The adsorption breakthrough curves could not be modeled correctly using the adsorption isotherm because of a strong dependence of the accessible free column volume on the phenol concentration in the mobile phase. It seems that retention in water depends on the extent to which the surface is wetted by the mobile phase, extent which is a function of the phenol concentration, and of the local pressure rate, which varies along the column, and on the initial state of the column. By contrast, the desorption profiles agree well with those calculated with the desorption isotherms using the ideal model, due to the high column efficiency. The isotherm model accounting best for the desorption isotherm data and the desorption profiles is the bi-Langmuir model. Its coefficients were calculated using appropriate weights in the fitting procedure. The evolution of the bi-Langmuir isotherm parameters with the initial equilibrium plateau concentration of phenol is discussed. The FACP results reported here are fully consistent with the adsorption data of phenol previously reported and measured by FA with various aqueous solutions of methanol as the mobile phase. They provide a general, empirical adsorption model of phenol that is valid between 0 and 65% of methanol in water.  相似文献   

10.
The adsorption behavior of proline under hydrophilic interaction chromatography conditions was investigated from six aqueous solutions of acetonitrile. Proline adsorption isotherms were recorded at each mobile phase composition by frontal analysis and inverse method. The BET model was found to be the best choice to describe the nonlinear behavior of proline adsorption under hydrophilic interaction chromatography conditions. The adsorption isotherm parameters were derived from two independent parameter estimation methods. The parameters derived from regression analysis of the frontal analysis data and from overloaded elution bands were found to be in good agreement with the excess isotherm of water. The mobile phase composition at which the maximum excess adsorption of water was observed corresponded to the maximum saturation capacity measured for proline.  相似文献   

11.
A new equation of competitive isotherms was derived in the framework of the ideal adsorbed solution (IAS) that predicts multisolute adsorption isotherms from single-solute isotherms. The IAS theory makes this new isotherm thermodynamically consistent, whatever the saturation capacities of these single-component isotherms. On a Kromasil-C(18) column, with methanol-water (80/20 v/v) as the mobile phase, the best single-solute adsorption isotherm of both toluene and ethylbenzene is the liquid-solid extended multilayer BET isotherm. Despite a significant difference between the monolayer capacities of toluene (370 g/l) and ethylbenzene (170 g/l), the experimental adsorption data fit very well to single-component isotherms exhibiting the same capacities (200 g/l). The new competitive model was used for the modeling of the elution band profiles of mixtures of the two compounds. Excellent agreement between experimental and calculated profiles was observed, suggesting that the behavior of the toluene-ethylbenzene adsorbed phase on the stationary phase is close to ideal. For example, the concentrations measured for the intermediate plateau obtained in frontal analysis differ by less than 2% from those predicted by the IAS model.  相似文献   

12.
With frontal analysis(FA),the dependence of adsorption isotherms of insulin on the composition of mobile phase in reversed phase liquid chromatography (RPLC) has been investigated,This is also a good example to employ the stoichiometric displacement theory (SDT) for ivestigating solute adsorption in physical chemistry.Six kinds of mobile phase in RPLC were employed to study the effects on the elution curves and adsorption isotherms of insulin.the key points of this paper are:(1) the stability of insulin due to delay time after preparing,the organic solvent concentration,the kind and the concentration of ion-pairing agent in mobile phase were found to affect both elution curve and adsorption isotherm very seriously.(2)To obtain a valid and comparable result,the composition of the mobile phase employed in FA must be as same as possible to that in usual RPLC of either analytical scale or preparative purpose.(3)Langmuir Equation and the SDT were employed to imitate these obtained adsorption isotherms.The expression for solute adsorption from solution of the SDT was found to have a better elucidation to the insulin adsorption from mobile phase in RPLC.  相似文献   

13.
The adsorption isotherms of phenol were acquired by frontal analysis on six different reversed phase adsorbents from five different organic solvent solutions. The end-capped octadecyl columns only differed in the bonding density of the C(18) ligands. The inverse method was used to confirm the estimated isotherm parameters derived from the frontal experiments. The effect of the bonding density of the end-capped octadecyl bonded phase on the adsorption properties of phenol from different mobile phase compositions was investigated. The adsorption behavior of phenol has changed from Langmuir type to BET type with the change of the organic modifier and the bonding density of the adsorbent.  相似文献   

14.
合成了一种新型奎宁-冠醚组合型手性固定相(QN-CR CSP)并用于氨基酸手性对映体的直接拆分,该固定相对12种氨基酸对映体有良好的手性拆分能力。基于氨基酸手性识别中离子交换和络合的协同作用,建立了一种新型的等温吸附模型。通过迎头特殊点洗脱法(FACP)测定色氨酸(Trp)在不同金属离子添加剂条件下的等温吸附线,验证了模型的合理性。流动相中的Li+、Na+、K+等金属离子与氨基酸竞争固定相中的冠醚络合位点,随着金属离子与冠醚的络合作用力和络合吸附平衡常数增大,固定相对Trp的手性拆分能力下降。该模型的建立对理解氨基酸在此类固定相中的手性保留行为以及固定相结构的进一步优化具有重要意义。  相似文献   

15.
Inverse liquid chromatography (ILC) has been used to determine experimental isotherms for the equilibrium adsorption of cyclohexanone onto a silica (61.8 m(2)/g) from hexane using the peak maximum (PM), elution by characteristic point (ECP), frontal analysis (FA), and frontal analysis by characteristic point (FACP) methods. Isotherms obtained using these four approaches gave good internal agreement, as well as being in good agreement with classically determined isotherms. Columns were successfully packed using a dry powder packing method with 9 microm diameter silica particles, and excellent intercolumn and instrument to instrument reproducibility was obtained for PM isotherms. The theoretical background to the PM, ECP, FA, and FACP methods, as well as the practical facets of isotherm determination using these methods, is outlined in this work.  相似文献   

16.
循环伏安法结合原位拉曼光谱的表征结果表明,烟酸在铁钝化膜层表面的吸附行为归因于其具有形成稳定膜层复合物的性能,烟酸将间隙离子FeⅡ转化为稳定的晶格离子FeⅢ,从而降低铁钝化膜的溶解性.旋转电极电化学晶体微天平的分析结果表明烟酸在活化态和钝化态铁表面的吸附行为遵循LangmuirFreundlich热力学规律,并由此计算出过程中的吸附常数、标准自由能和非均质分布常数.研究认为有机分子在钝化膜表面为化学型吸附,可导致钝化膜破坏的间隙离子被烟酸固定在八面体空位晶格中形成稳定晶型结构,并通过扫描电镜(SEM)和衰减全反射红外光谱(ATR FTIR)分析对结论进行了再次验证.  相似文献   

17.
18.
An enzyme inhibition biosensor, developed in our laboratory and previously used for the analysis of compounds with anticholinesterase activity (e.g. physostigmine, neostigmine, pyridostigmine nicotine and organophosphorus compounds) has now been tested for the analysis of another recently synthesized cholinesterase inhibitor, i.e. eptastigmine. In addition nicotinic acid and nicotinamide, although displaying weaker inhibition properties, were also tested in pharmaceutical products using the same inhibition enzyme sensor. The biosensor consisted of a hydrogen peroxide amperometric electrode coupled to a functionalised nylon membrane chemically bonding both the enzymes butyrylcholinesterase and choline oxidase; a butyrylcholine standard solution in glycine buffer acted as substrate. The response of the system to all the inhibitors considered was characterised completely and the analysis of several pharmaceutical formulations containing nicotinamide or nicotinic acid was also performed.  相似文献   

19.
Summary In this paper, we report and discuss the adsorption isotherms of hydro-organic mixtures and of compounds used as mobile phase in reversed phase and normal phase high performance liquid chromatography (RP-HPLC and NP-HPLC, respectively). This work is the first attempt to study the solid-liquid interface between two types of chromatographic silica surfaces and pure organic adsorbates from water and from organic eluents by HPLC. Frequently, among the dynamic techniques the method of choice for the measurement of an adsorption isotherm is frontal analysis. We suggest here the combination of the technique based on peak asymmetry calibration and peak profiles, which allows calculations directly from integration data. The group of systems studied permits the analysis of the intermolecular interactions on the silica surface. Particular attention was given to the system methanol-water and the measurement of the adsorption ofn-octanol from methanol on RP-silica was also carried out.  相似文献   

20.
Nicorandil [N-(2-hydroxyethyl)-nicotinamide nitrate NIC] is a novel kind of compound in the treatment of angina pectoris. NIC can be degraded easily in storage. The degradation products include N-(2-hydroxyethy) nicotinamide (HN), nitrate ion (NI), and ni…  相似文献   