首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 524 毫秒
1.
《Electrophoresis》2018,39(17):2188-2194
This study describes the development of a new analytical method for the separation and detection of cocaine (COC) and its adulterants, or cutting agents, using microchip electrophoresis (ME) devices coupled with capacitively coupled contactless conductivity detection (C4D). All the experiments were carried out using a glass commercial ME device containing two pairs of integrated sensing electrodes. The running buffer composed of 20 mmol/L amino‐2‐(hydroxymethyl) propane‐1,3‐diol and 10 mmol/L 3,4‐dimethoxycinnamic acid provided the best separation conditions for COC and its adulterants with baseline resolution (R > 1.6), separation efficiencies ranging from (2.9 ± 0.1) to (3.2 ± 0.2) × 105 plates/m, and estimated LOD values between 40 and 150 μmol/L. The quantification of COC was successfully performed in four samples seized by the Brazilian Federal Police Department and all predicted values agree with values estimated by the reference method. Some other interfering species were detected in the seized samples during the screening procedure on ME–C4D devices. While lidocaine was detected in sample 3, the presence of levamisole was observed in samples 2 and 4. However, their concentrations were estimated to be below the LOQ. ME–C4D devices have proved to be quite efficient for the identification and quantification of COC with errors lower than 10% when compared to the data obtained by a reference method. The approach herein reported offers great potential to be used for on‐site COC screening in seized samples.  相似文献   

2.
This study describes the development of an analytical methodology based on the use of microchip electrophoresis (ME) devices integrated with capacitively coupled contactless conductivity detection (C4D) for the separation and detection of inorganic anions in post‐blast explosive residues. The best separation condition was achieved using a running buffer composed of 35 mmol/L lactic acid, 10 mmol/L histidine and 0.070 mmol/L cetyl(trimethyl ammonium) bromide. For C4D measurements, the highest sensitivity was obtained applying a 700 kHz sinusoidal wave with excitation voltage of 20 Vpp. The separation of Cl?, NO3?, NO2?, SO42?, ClO4? and ClO3? was performed within ca. 150 s with baseline resolution and efficiencies between 4.4 × 104 and 1.7 × 105 plates/m. The found limits of detection ranged between 2.5 and 9.5 μmol/L. Last, real samples of post‐blast explosive residues were analyzed on the ME‐C4D devices obtaining successfully the determination of Cl?, NO3? and SO42?. The achieved concentration values varied between 12.8–72.5 mg/L for Cl?, 1.7–293.1 mg/L for NO3? and 1.3–201.3 mg/L for SO42?. The data obtained using ME‐C4D devices were in good agreement with the concentrations found by ion chromatography. The approach reported herein has provided short analysis time, instrumental simplicity, good analytical performance and low cost. Furthermore, the ME‐C4D devices emerge as a powerful and portable analytical platform for on‐site analysis demonstrating to be a promising tool for the crime scene investigation.  相似文献   

3.
We present a new theoretical approach for calculating changes in the physico-chemical properties of BGEs for measurements by CZE due to the electrolysis in electrode vials (vessels). Electrolysis is an inevitable phenomenon in any measurement in CZE. Water electrolysis, which occurs in most measurements, can significantly alter the composition of the BGE in electrode vials and in the separation capillary and has a negative influence on the robustness and quality of separations. The ability to predict changes in the composition of the BGE is important for evaluation of the suitability of the BGEs for repeating electrophoretic runs. We compared theoretically calculated changes in the physico-chemical properties (pH, conductivity) with those measured using pH-microelectrode and contactless conductivity detection of the BGE after the electrophoretic run. We confirmed the validity of our theoretical approach with a common BGE composed of acid-base pair, where one constituent is fully dissociated while the second constituent is dissociated by only half, and with Good's buffer. As predicted by theoretical approach, the changes in the physico-chemical properties of the Good's buffer after the electrophoretic run were several times lower than in the case of a common BGE composed of a weak acid – strong base pair.  相似文献   

4.
Polyimide HPLC‐Chip devices containing poly(methylstyrene‐bis‐p‐vinylphenyl)ethane (MS/BVPE) stationary phase within the device channels and with wall attachment were prepared by thermally initiated free radical polymerization. The microfluidic devices were coupled to both UV and MS detectors. The potential of the MS/BVPE monolith as an alternative separation media within chip devices was investigated by side‐by‐side comparisons to particulate media within commercial devices. The chromatographic behavior of this stationary phase was comparable to particulate media for separations of proteins as the average peak width at half‐height was equal (6.2 s) for a separation within 8 min under gradient elution conditions. The ability to control the porosity characteristics of the MS/BVPE monolith with changes in polymerization time also extended its utility into small analyte (< 500 Da) applications, although more optimization is needed to match conventional RP media for these applications. The good mechanical stability of the MS/BVPE monolith within the microdevices enabled excellent run‐to‐run repeatability (%RSD retention time (? 0.16) and chip‐to‐chip reproducibility (%RSD retention time (1.4). The use of this material within enrichment channels also shows its potential value in more complex work flows.  相似文献   

5.
A multi‐functional separation column modified with 3‐[2‐(2‐aminoethylamino)ethylamino] propyl‐trimethoxysilane was developed for open tubular capillary electrochromatography. This functional hydrophilic triamine‐bonded open tubular column could generate both anodic and cathodic EOF. When the pH of the running buffer was below 5.3 (30% 3‐[2‐(2‐aminoethylamino)ethylamino] propyl‐trimethoxysilane, v/v), the anodic EOF was exhibited, which greatly prevented the undesired adsorptions of basic proteins on the capillary inner wall. Favorable separation of four basic proteins (viz. trypsin, ribonuclease A, lysozyme and cytochrome c) was successfully achieved at pH 3.5 of 10 mmol/L phosphate buffer. The column efficiencies of proteins were in the range from 87 000 to 110 000 plates/m, and the RSD values for migration time of four proteins were less than 1.2% (run‐to‐run, n=5). The ionic analytes were also separated efficiently in the co‐electroosmotic mode. The average efficiencies ranged from 81 000 to 190 000 plates/m for seven aromatic acids and 186 000–245 000 plates/m for four nucleoside monophosphates, respectively, and good capillary column repeatability was gained with RSD of the migration time not more than 3.0%. The triamine‐bonded open tubular capillary column is favorable to be an alternative functional medium for the further analysis of basic proteins and anionic analytes.  相似文献   

6.
Optimization based on central composite design (CCD) for enantioseparation of anisodamine (AN), atenolol (AT), and metoprolol (ME) in human urine was developed using a microfluidic chip‐CE device. Coupling the flexible and wide working range of microfluidic chip‐CE device to CCD for chiral separation of AN, AT, and ME in human urine, a total of 15 experiments is needed for the optimization procedure as compared to 75 experiments using the normal one variable at a time optimization. The optimum conditions obtained are found to be more robust as shown by the curvature effects of the interaction factors. The developed microfluidic chip‐CE‐ECL system with adjustable dilution ratios has been validated by satisfactory recoveries (89.5–99% for six enanotiomers) in urine sample analysis. The working range (0.3–600 μM), repeatability (3.1–4.9% RSD for peak height and 4.0–5.2% RSD for peak area), and detection limit (0.3–0.6 μM) of the method developed are found to meet the requirements for bedside monitoring of AN, AT, and ME in patients under critical conditions. In summary, the hyphenation of CCD with the microfluidic chip‐CE device is shown to offer a rapid means for optimizing the working conditions on simultaneous separation of three racemic drugs using the microfluidic chip‐CE device developed.  相似文献   

7.
This paper reports for the first time the use of colored toner to produce polyester toner (PT) ME devices. Colored PT devices were designed in drawing software and printed on a polyester film using a color laser printer with 3600 dpi resolution. The colored toner is composed of a copolymer mixture (styrene and acrylate), wax, silicon dioxide, and pigments. The presence of silica in the toner composition has enhanced the EOF magnitude and improved the analytical performance. For a pH range between 2 and 12, the EOF measured on a magenta PT chip, for example, ranged from 3.8 to 5.8 (× 10?4 cm2 V?1 s?1). Typical separations of inorganic cations (K+, Na+, and Li+) were used as model system to investigate the analytical feasibility of the proposed devices. The repeatability for the migration times of all analytes exhibited RSD values lower than 1% (n = 10). The separation efficiencies found on colored PT devices ranged from 10 000 to 49 000 plates/m, which means between 7 and 23% of the maximum theoretical efficiency on this microfluidic platform (1.85 × 105 plates/m). The improvements achieved on the proposed devices are associated with the small additional amount of silica on the toner composition as well as the printing of channels with smoother surfaces and better uniformity when compared to the conventional PT chips printed with monochromatic laser printers.  相似文献   

8.
林秀丽  李关宾  主沉浮  吴培  关亚风 《色谱》2001,19(2):109-111
 建立了一种以L 白氨酸为手性选择剂用毛细管区带电泳法快速分离 12种手性药物的方法。实验结果表明 ,手性对映体的分离度受L 白氨酸浓度和缓冲液 pH的影响。在含有 70mmol/LL 白氨酸 ,5 0mmol/L硼砂 (pH9.0 )的溶液中 ,12种手性药物在 11min之内得到了基线分离。  相似文献   

9.
Fung YS  Lau KM 《Electrophoresis》2003,24(18):3224-3232
To meet the need for a new and validated analytical method for simultaneous determination of inorganic and organic acid anions in beverage drinks, a capillary zone electrophoresis (CZE) procedure had been developed based on a new background electrolyte (BGE) system containing 3 mmol/L 1,3,5-benzenetricarboxylic acid (BTA), 15 mmol/L tris(hydroxymethyl)aminomethane and 1.5 mmol/L tetraethylenepentamine (TEPA) at pH 8.4. Baseline separation of anions commonly found in beverage drinks could be achieved in less than 14 min with indirect UV detection at 240 nm. Comigration problems for hydroxycarboxylic acids could be solved using TEPA as BGE additive. The results indicate excellent repeatability for migration time (RSD, 0.27-0.67%, n = 5) and good precision for both peak height (RSD, 3.2-4.2%, n = 5) and peak area (RSD, 3.1-4.5%, n = 5). Under the optimized conditions and using corrected peak area for quantitation, an excellent linear dynamic range (with correlation coefficient > 0.997 in a concentration range from 0.005 to 2.0 mmol/L) and low detection limit (1-4 micro mol/L) were obtained for all the anions investigated. The applicability and reliability of the CE procedure developed were established by parallel method determination using established ion chromatography procedure for the analysis of inorganic and organic acid anions in orange juice and wine samples. Our CZE procedure provided a sensitive and economic technique for simultaneous determination of inorganic and organic acid anions in orange juice, red and white wine samples.  相似文献   

10.
The usefulness of a noncovalent capillary coating consisting of two layers of oppositely charged polymers for the separation of peptides with capillary electrophoresis (CE) was studied. Capillaries were coated simply by subsequently flushing with solutions of 1% m/v Polybrene and 1% v/v poly(vinylsulfonate) (PVS) forming a bilayer, which showed to produce a strong and highly reproducible electroosmotic flow (EOF) at low pH. Using this coating in combination with a background electrolyte (BGE) containing sodium phosphate (pH 2.5) and 0.01% v/v PVS, initially broadened and overlapping peaks were obtained for some test peptides. By omitting the PVS from the BGE, the peak width and shape of the peptides improved resulting in baseline separation. A systematic study of the influence of the BGE composition showed that considerable further enhancement of the separation efficiency was achieved by increasing the ionic strength of the BGE. Using a BGE of 200 mM tris(hydroxymethyl)aminomethane (Tris)-phosphate (pH 2.5) plate numbers for the peptides were in the 300 000-600 000 range and the relative standard deviation of the peptide migration times was less then 0.3% (n = 5). The use of Tris-phosphate instead of sodium phosphate allowed the current to stay within acceptable limits when 30 kV was used as separation voltage. Overall, the bilayer coating showed a remarkable EOF repeatability, as well as long-term stability. Compared to bare fused-silica capillaries the intraday and interday repeatability of migration times was very favorable and coated capillaries could be used for over a month performing analyses with low and high ionic strength BGEs without any performance deterioration. The usefulness of the bilayer-coated capillaries for the analysis of positively charged peptides was demonstrated by the fast and efficient separation of various closely related enkephalins and the baseline separation of an isomeric peptide/peptoid couple exhibiting efficiencies of over 550 000 plates.  相似文献   

11.
[2‐(Methacryloyl)oxyethyl]trimethylammonium chloride was successfully polymerized by surface‐initiated atom transfer radical polymerization method on the inner surface of fused‐silica capillaries resulting in a covalently bound poly([2‐(methacryloyl)oxyethyl]trimethylammonium chloride) coating. The coated capillaries provided in capillary electrophoresis an excellent run‐to‐run repeatability, capillary‐to‐capillary and day‐to‐day reproducibility. The capillaries worked reliably over 1 month with EOF repeatability below 0.5%. The positively charged coated capillaries were successfully applied to the capillary electrophoretic separation of three standard proteins and five β‐blockers with the separation efficiencies ranging from 132 000 to 303 000 plates/m, and from 82 000 to 189 000 plates/m, respectively. In addition, challenging high‐ and low‐density lipoprotein particles could be separated. The hydrodynamic sizes of free polymer chains in buffers used in the capillary electrophoretic experiments were measured for the characterization of the coatings.  相似文献   

12.
The aim of the present study is the CE performance evaluation for the separation of 2‐arylpropionic acid nonsteroidal anti‐inflammatory drugs. In particular, the separation of indoprofen, carprofen, ketoprofen, ibuprofen, and flurbiprofen was obtained by supporting the BGE either with SDS or an amino acid ester‐based ionic liquid (AAIL). The performance of these additives was evaluated by comparing migration times, efficiencies and %RSD values. The addition of the AAIL into the BGE provided baseline separation within 10 min, while in the case of SDS, the analytes eluted within 23 min. The optimum conditions involve a BGE of 100 mM Tris/10 mM sodium tetraboratedecahydrate (pH 8) and 40 mM l ‐alanine tert butyl ester lactate or 10 mM SDS and a temperature of 35°C for AAIL and 20°C for SDS. The run‐to‐run reproducibility was evaluated by computing the %RSD values of the EOF and the analyte peaks. When the AAIL was used, an excellent reproducibility was obtained, since all %RSD values were below 1.3%. On the contrary, the addition of SDS resulted in much higher RSD values (2.1–11.7%). The efficiency values of all analyte peaks were above 102 000 for l ‐AlaC4Lac, in comparison to SDS, which provided efficiency values between 47000 and 76000. Finally, in an attempt to study the synergistic effect of SDS and AAIL, both additives were added into the BGE at concentrations of 10 and 40 mM, respectively. The results were similar to the ones obtained when SDS was used as the sole additive.  相似文献   

13.
Five non‐steroidal anti‐inflammatory drugs, naproxen, fenoprofen, ketoprofen, diclofenac and piroxicam, were separated and analyzed by electrokinetic supercharging in CZE. Three different setups of the ITP technique were assayed for the separation and preconcentration of these five non‐steroidal anti‐inflammatory drugs. For the setup that gave the best results, we evaluated the influence of different parameters on separation and preconcentration efficiency such as sample pH, concentration of the leading stacker, BGE composition, electrokinetic injection time, composition and hydrodynamic injection of the solvent plug and of the terminating stacker. In the selected setup, the BGE (10 mM Na2B4O7 + 50 mM NaCl in 10% of MeOH aqueous solution) contained the leading electrolyte while the terminating electrolyte, hydrodynamically injected after the sample (50 mbar×12 s), was 50 mM of CHES. Prior to sample injection at (700 s at −2 kV) a short plug of MeOH (50 mbar ×3 s) was hydrodynamically injected. The results show that this strategy enhanced detection sensitivity 2000‐fold compared with normal hydrodynamic injection, providing detection limits of 0.08 μg/L for standard samples with good repeatability (values of relative standard deviation, %RSD < 1.03%). Method validation with river water samples and human plasma demonstrated good linearity, with detection limits of 0.9 and 2 μg/L for river water samples and human plasma samples, respectively (as well as satisfactory precision in terms of repeatability and reproducibility).  相似文献   

14.
Two in‐line enrichment procedures (large volume sample stacking (LVSS) and field amplified sample injection (FASI)) have been evaluated for the CZE analysis of haloacetic acids (HAAs) in drinking water. For LVSS, separation on normal polarity using 20 mM acetic acid–ammonium acetate (pH 5.5) containing 20% ACN as BGE was required. For FASI, the optimum conditions were 25 s hydrodynamic injection (3.5 kPa) of a water plug followed by 25 s electrokinetic injection (?10 kV) of the sample, and 200 mM formic acid–ammonium formate buffer at pH 3.0 as BGE. For both FASI and LVSS methods, linear calibration curves (r2>0.992), limit of detection on standards prepared in Milli‐Q water (49.1–200 μg/L for LVSS and 4.2–48 μg/L for FASI), and both run‐to‐run and day‐to‐day precisions (RSD values up to 15.8% for concentration) were established. Due to the higher sensitive enhancement (up to 310‐fold) achieved with FASI‐CZE, this method was selected for the analysis of HAAs in drinking water. However, for an optimal FASI application sample salinity was removed by SPE using Oasis WAX cartridges. With SPE‐FASI‐CZE, method detection limits in the range 0.05–0.8 μg/L were obtained, with recoveries, in general, higher than 90% (around 65% for monochloroacetic and monobromoacetic acids). The applicability of the SPE‐FASI‐CZE method was evaluated by analyzing drinking tap water from Barcelona where seven HAAs were found at concentration levels between 3 and 13 μg/L.  相似文献   

15.
In this study, the applicability of a chiral ionic liquid (CIL) as the sole chiral selector in CE was investigated for the first time. In particular, five amino acid ester‐based CILs were synthesized and used as additives in the BGE in order to evaluate their chiral recognition ability. The performance of these CILs as the sole chiral selectors was evaluated by using 1,1′‐binaphthyl‐2,2‐diylhydrogenphosphate (BNP) as the analyte and by comparing the resolution values. Different parameters were examined, such as the alkyl group bulkiness and the configuration of the cation, the anion type of the CIL and its concentration, and the pH of the BGE, in order to optimize the separation of the enantiomers and to demonstrate the effect that each parameter has on the chiral‐recognition ability of the CIL. Baseline separation of BNP within 13 min was achieved by using a BGE of 100 mM Tris/10 mM sodium tetraboratedecahydrate (pH 8) and a chiral selector of 60 mM l ‐alanine tert butyl ester lactate. The run‐to‐run and batch‐to‐batch reproducibilities were also evaluated by computing the %RSD values of the EOF and the two enantiomer peaks. In both cases, very good reproducibilities were observed, since all %RSD values were below 1%.  相似文献   

16.
Fuentes HV  Woolley AT 《Lab on a chip》2007,7(11):1524-1531
Electrolysis-based micropumps integrated with microfluidic channels in micromachined glass substrates are presented. Photolithography combined with wet chemical etching and thermal bonding enabled the fabrication of multi-layer devices containing electrically actuated micropumps interfaced with sample and mobile phase reservoirs. A stationary phase was deposited on the microchannel walls by coating with 10% (w/w) chlorodimethyloctadecylsilane in toluene. Pressure-balanced injection was implemented by controlling the electrolysis time and voltage applied in the two independent micropumps. Current fluctuations in the micropumps due to the stochastic formation of bubbles on the electrode surfaces were determined to be the main cause of variation between separations. On-chip electrochemical pumping enabled the loading of pL samples with no dead volume between injection and separation. A mobile phase composed of 70% acetonitrile and 30% 50 mM acetate buffer (pH 5.45) was used for the chromatographic separation of three fluorescently labeled amino acids in <40 s with an efficiency of >3000 theoretical plates in a 2.5 cm-long channel. Our results demonstrate the potential of electrochemical micropumps integrated with microchannels to perform rapid chromatographic separations in a microfabricated platform. Importantly, these devices represent a significant step toward the development of miniaturized and fully integrated liquid chromatography systems.  相似文献   

17.
三角形法和四面体法优化选择毛细管区带电泳背景电解质   总被引:1,自引:1,他引:1  
孙国祥  宋文璟  林婷 《色谱》2008,26(2):232-236
建立了两种高效、快速的毛细管区带电泳背景电解质(BGE)的优化方法三角形优化法和四面体优化法。以色谱指纹图谱指数F和色谱指纹图谱相对指数Fr作为评价毛细管电泳分析系统的目标函数,以雪莲药材水提取液为样品,考察一定浓度的硼砂、硼酸、磷酸氢二钠和磷酸二氢钠溶液按三角形优化法和四面体优化法构成背景电解质时对样品的分离情况,通过添加有机改性剂和调节pH进行再优化。用三角形法优化出以50 mmol/L硼砂-含3%乙腈的150 mmol/L磷酸二氢钠(体积比为1∶1)作为BGE时分离效果最佳,用四面体法优化出以50 mmol/L硼砂-150 mmol/L磷酸二氢钠-200 mmol/L硼酸(体积比为1∶1∶2,用0.1 mol/L氢氧化钠调pH 8.55)作为BGE时分离效果最佳,分别获得28个和25个电泳峰。所建立的方法操作简捷,适用于中药材水提取液或醇提取液的毛细管区带电泳BGE的选择。  相似文献   

18.
Although paper‐based analysis is known for centuries, only during the last decade this simple substrate became an object of detailed microfluidic studies. In order to obtain optimum performance and separation of the analytes in a microfluidic channel, devices should be optimized, both in terms of architecture and paper properties. Enzyme immobilization methods can not only increase the storage stability but also have an impact on the flow in paper matrix, providing additional charges, and changing the porous structure of paper. Therefore it should be guaranteed that the method of choice will not obstruct the flux in the final device. Paper‐based device proposed in this study was composed of a bioactive channel, Pt working electrode, pencil drawn pseudo‐reference electrode, a buffer filled sponge providing the wicking solution and a stack of wicking pads to guarantee continuous flow. Based on our previous research we chose 4 methods of enzyme immobilization relying on different phenomena (adsorption, covalent linkage, layer‐by‐layer, capsules). Different channel architectures were also evaluated in order to achieve optimum time of the enzymatic reaction, separation of peaks and the time of measurement. Experimental results were compared with computer simulations. Final device could quantify glucose (2.0–10.0 mmol L?1) and uric acid (0.1–1.2 mmol L?1) in their clinical range with good repeatability.  相似文献   

19.
A method for the determination of ethambutol (EMB), a first‐line drug against tuberculosis, based on CE with capacitively coupled contactless conductivity detection is proposed. The separation of EMB and its main product of degradation were achieved in less than 3 min with a resolution of 2.0 using a BGE composed of 50 mmol/L histidine and 30 mmol/L MES, pH 6.30. By raising the pH to 8.03, the analysis time was reduced to 1.0 min, but with a significant loss of resolution (0.7). Using the best separation conditions, linearity of 0.9976 (R2, five data points), sensitivity of 1.26×10?4 V min μmol?1 L, and LOD and quantification of 23.5 and 78.3 μmol/L, respectively, were obtained. Recoveries at four levels of concentration ranged from 95 to 102% and the concentration range studied ranged from 100 to 500 μmol/L. The results obtained for the determination of EMB in pharmaceutical formulations were compared with those obtained by using CE with photometric detection.  相似文献   

20.
《Electrophoresis》2017,38(13-14):1764-1770
Gel electrophoresis is one of the most applied and standardized tools for separation and analysis of macromolecules and their fragments in academic research and in industry. In this work we present a novel approach for conducting on‐demand electrophoretic separations of DNA molecules in open microfluidic (OM) systems on planar polymer substrates. The approach combines advantages of slab gel, capillary‐ and chip‐based methods offering low consumable costs (<0.1$) circumventing cost‐intensive microfluidic chip fabrication, short process times (5 min per analysis) and high sensitivity (4 ng/μL dsDNA) combined with reasonable resolution (17 bases). The open microfluidic separation system comprises two opposing reservoirs of 2–4 μL in volume, a semi‐contact written gel line acting as separation channel interconnecting the reservoirs and sample injected into the line via non‐contact droplet dispensing and thus enabling the precise control of the injection plug and sample concentration. Evaporation is prevented by covering aqueous structures with PCR‐grade mineral oil while maintaining surface temperature at 15°C. The liquid gel line exhibits a semi‐circular cross section of adaptable width (∼200–600 μm) and height (∼30–80 μm) as well as a typical length of 15–55 mm. Layout of such liquid structures is adaptable on‐demand not requiring time consuming and repetitive fabrication steps. The approach was successfully demonstrated by the separation of a standard label‐free DNA ladder (100–1000 bp) at 100 V/cm via in‐line staining and laser induced fluorescent end‐point detection using an automated prototype.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号