首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The emergence of optofluidics has brought a high degree of tuneability and reconfigurability to optical devices. These possibilities are provided by characteristics of fluids including mobility, wide range of index modulation, and abrupt interfaces that can be easily reshaped. In this work, we created a new class of optofluidic waveguides, in which suspended mesoparticles were employed to greatly enhance the flexibility of the system. We demonstrated tuneable quasi single mode waveguides using spatially controllable mesoparticles in optofluidics. The coupling of waveguiding modes into the assembly of mesoparticles produces strong interactions and resonant conditions, which promote the transitions of the waveguiding modes. The modal response of the system depends on the distribution of packed particles above the polymeric rib waveguide which can be readily controlled under the appropriate combination of dielectrophoresis and hydrodynamic forces.  相似文献   

2.
Dielectrophoresis (DEP) is a non-destructive, accurate, and label-free cell manipulating technique and DEP applications have been found in various fields. Assessment of cell viability is one of the important applications and many investigations have been reported. In this paper, cell polarization and its modeling, some key parameters employed for living/dead cell separation, as well as electrode configurations are reviewed. Focus is given to the latest development of DEP devices employed for the assessment of cell viability. Experimentally determined factors for separating living/dead cells, such as the conductivity of suspending medium and the frequency of applied electric field, are summarized. The future directions and potential challenges in this field are also outlined.  相似文献   

3.
The addition of 1–20% (v/v) of methanol or acetonitrile as organic modifier to the mobile phase in a micellar electrokinetic capillary chromatographic (MECC) system, containing sodium dodecyl sulfate and a buffer, is shown to extend the elution range and thus increase the peak capacity of a given system. Although the net change in the elution range parameter, to/tmc, is essentially the same for both modifiers, the acetonitrile-modified system exhibits much faster elution times for the polar and non-polar test solutes employed in this study. Retention, as measured by the capacity factor, is generally decreased with the increase of an organic modifier, just as in conventional reversed phase chromatography. However, changes in selectivity as a function of the added modifiers are noted among polar and non-polar solutes as well. The efficiency of these MECC systems is increased with the addition of either organic modifier.  相似文献   

4.
A comparison of separations conducted in sodium dodecyl sulfate (SDS) and SDS modified with Brij 35 indicates that selectivity, in Micellar Electrokinetic Chromatography (MEKC), is governed by the composition of the micellar phase. Beyond selectivity optimization, resolution may be improved by increasing efficiency or decreasing electroosmotic flow. Of these approaches, increasing capillary length (to improve efficiency) should be a more time effective means of improving separation.  相似文献   

5.
Analytes concentration techniques are being developed with the appealing expectation to boost the performance of biosensors. One promising method lies in the use of electrokinetic forces. We present hereafter a new design for a microstructured plasmonic sensor which is obtained by conventional microfabrication techniques, and which can easily be adapted on a classical surface plasmon resonance imaging (SPRI) system without further significant modification. Dielectrophoretic trapping and electro‐osmotic displacement of the targets in the scanned fluid are performed through interdigitated 200 μm wide gold electrodes that also act as the SPR‐sensing substrate. We demonstrate the efficiency of our device's collection capabilities for objects of different sizes (200 nm and 1 μm PS beads, as well as 5–10 μm yeast cells). SPRI is relevant for the spatial analysis of the mass accumulation at the electrode surface. We demonstrate that our device overcomes the diffusion limit encountered in classical SPR sensors thanks to rapid collection capabilities (<1 min) and we show a consequent improvement of the detection limit, by a factor >300. This study of an original device combining SPRI and electrokinetic forces paves the way to the development of fully integrated active plasmonic sensors with direct applications in life sciences, electrochemistry, environmental monitoring and agri‐food industry.  相似文献   

6.
Insulator-based dielectrophoretic (iDEP) microdevices have been limited to work with Newtonian fluids. We report an experimental study of the fluid rheological effects on iDEP focusing and trapping of polystyrene particles in polyethylene oxide, xanthan gum, and polyacrylamide solutions through a constricted microchannel. Particle focusing and trapping in the mildly viscoelastic polyethylene oxide solution are slightly weaker than in the Newtonian buffer. They are, however, significantly improved in the strongly viscoelastic and shear thinning polyacrylamide solution. These observed particle focusing behaviors exhibit a similar trend with respect to electric field, consistent with a revised theoretical analysis for iDEP focusing in non-Newtonian fluids. No apparent focusing of particles is achieved in the xanthan gum solution, though the iDEP trapping can take place under a much larger electric field than the other fluids. This is attributed to the strong shear thinning-induced influences on both the electroosmotic flow and electrokinetic/dielectrophoretic motions.  相似文献   

7.
Presented here are the results from numerical simulations applying optical forces orthogonally to electroosmotically induced flow containing both molecular species and particles. Simulations were conducted using COMSOL v4.2a Multiphysics® software including the particle tracking module. The study addresses the application of optical forces to selectively remove particulates from a mixed sample stream that also includes molecular species in a pinched flow microfluidic device. This study explores the optimization of microfluidic cell geometry, magnitude of the applied direct current electric field, EOF rate, diffusion, and magnitude of the applied optical forces. The optimized equilibrium of these various contributing factors aids in the development of experimental conditions and geometry for future experimentation as well as directing experimental expectations, such as diffusional losses, separation resolution, and percent yield. The result of this work generated an optimized geometry with flow conditions leading to negligible diffusional losses of the molecular species while also being able to produce particle removal at near 100% levels. An analytical device, such as the one described herein with the capability to separate particulate and molecular species in a continuous, high‐throughput fashion would be valuable by minimizing sample preparation and integrating gross sample collection seamlessly into traditional analytical detection methods.  相似文献   

8.
Noninvasive and nondestructive techniques for monitoring and manipulating cells or biomolecules are essential for understanding biological processes. Optical methodologies have been used for the noninvasive and nondestructive monitoring of intracellular molecules and manipulation of cellular activities to elucidate the localization and interactions of these biomolecules. Since the pioneering work of Ashkin, optical trapping has been used to study cellular elasticity and mechanical characteristics of intracellular molecules. In recent years, there has been a substantial amount of research on the optical manipulation of nanometer-sized objects, including the manipulation of the assembly of nanomaterials and the enhancement of optical forces with optical resonance effects. In the study of biomolecular manipulation by optical forces, the functions and roles of biomolecules have been clarified by analyzing the changes in cellular functions induced by manipulation. In this review, we focus on recent studies on optical trapping for the manipulation of living cells or biomolecules and introduce techniques for the manipulation of cellular functions using optical forces.  相似文献   

9.
Microfluidic separation of particles and cells is crucial to lab-on-a-chip applications in the fields of science, engineering, and industry. The continuous-flow separation methods can be classified as active or passive depending on whether the force involved in the process is externally imposed or internally induced. The majority of current separations have been realized using only one of the active or passive methods. Such a single-mode process is usually limited to one-parameter separation, which often becomes less effective or even ineffective when dealing with real samples because of their inherent heterogeneity. Integrating two or more separation methods of either type has been demonstrated to offer several advantages like improved specificity, resolution, and throughput. This article reviews the recent advances of such multimode particle and cell separations in microfluidic devices, including the serial-mode prefocused separation, serial-mode multistage separation, and parallel-mode force-tuned separation.  相似文献   

10.
Microfluidic production of multicompartmental emulsion droplets and particles has received considerable attention of late. In particular, droplets having two physically and chemically distinct segments (so-called Janus droplets) and the anisotropic particles synthesized from these droplets, are becoming increasingly popular because of their novel and promising properties, which make them suitable for use in numerous applications, including for controlled drug release, display devices, and self-assembly. So far, a range of interesting anisotropies have been accorded to Janus droplets and particles via microfluidics; these span from chromatic, magnetic, and hydrophobic–hydrophilic characteristics to selective degradation properties. Here, we summarize and discuss the recent trends related to Janus droplets and particles produced through microfluidic processing. We also review the parallelization technologies being developed for scaling up microfluidic emulsification in the industry.  相似文献   

11.
Microfluidic device embedding electrodes realizes cell manipulation with the help of dielectrophoresis. Cell manipulation is an important technology for cell sorting and cell population purification. Till now, the theory of dielectrophoresis has been greatly developed. Microfluidic devices with various arrangements of electrodes have been reported from the beginning of the single non‐uniform electric field to the later multiple physical fields. This paper reviews the research status of microfluidic device embedding electrodes for cell manipulation based on dielectrophoresis. Firstly, the working principle of dielectrophoresis is explained. Next, cell manipulation approaches based on dielectrophoresis are introduced. Then, different types of electrode arrangements in the microfluidic device for cell manipulation are discussed, including planar, multilayered and microarray dot electrodes. Finally, the future development trend of the dielectrophoresis with the help of microfluidic devices is prospected. With the rapid development of microfluidic technology, in the near future, high precision, high throughput, high efficiency, multifunctional, portable, economical and practical microfluidic dielectrophoresis will be widely used in the fields of biology, medicine, agriculture and so on.  相似文献   

12.
Insulator-based dielectrophoresis (iDEP), an efficient technique with great potential for miniaturization, has been successfully applied for the manipulation of a wide variety of bioparticles. When iDEP is applied employing direct current (DC) electric fields, other electrokinetic transport mechanisms are present: electrophoresis and electroosmotic flow. In order to concentrate particles, iDEP has to overcome electrokinetics. This study presents the characterization of electrokinetic flow under the operating conditions employed with iDEP; in order to identify the optimal conditions for particle concentration employing DC-iDEP, microparticle image velocimetry (μPIV) was employed to measure the velocity of 1-μm-diameter inert polystyrene particles suspended inside a microchannel made from glass. Experiments were carried out by varying the properties of the suspending medium (conductivity from 25 to 100 μS/cm and pH from 6 to 9) and the strength of the applied electric field (50–300 V/cm); the velocities values obtained ranged from 100 to 700 μm/s. These showed that higher conductivity and lower pH values for the suspending medium produced the lowest electrokinetic flow, improving iDEP concentration of particles, which decreases voltage requirements. These ideal conditions for iDEP trapping (pH = 6 and σ m = 100 μS/cm) were tested experimentally and with the aid of mathematical modeling. The μPIV measurements allowed obtaining values for the electrokinetic mobilities of the particles and the zeta potential of the glass surface; these values were used with a mathematical model built with COMSOL Multiphysics software in order to predict the dielectrophoretic and electrokinetic forces exerted on the particles; the modeling results confirmed the μPIV findings. Experiments with iDEP were carried out employing the same microparticles and a glass microchannel that contained an array of cylindrical insulating structures. By applying DC electric fields across the insulating structures array, it was seen that the dielectrophoretic trapping was improved when the electrokinetic force was the lowest; as predicted by μPIV measurements and the mathematical model. The results of this study provide guidelines for the selection of optimal operating conditions for improving insulator-based dielectrophoretic separations and have the potential to be extended to bioparticle applications. Figure Comparison of experimental measurements and mathematical modeling of electrokinetic and dielectrophoretic effects on microparticles
Blanca H. Lapizco-EncinasEmail:
  相似文献   

13.
14.
The relative polarization behavior of micron and submicron polystyrene particles was investigated under direct current and very low frequency (<1 kHz) alternating current electric fields. Relative polarization of particles with respect to the suspending medium is expressed in terms of the Clausius–Mossotti factor, a parameter of crucial importance in dielectrophoretic‐based operations. Particle relative polarization was studied by employing insulator‐based dielectrophoretic (iDEP) devices. The effects of particle size, medium conductivity, and frequency (10–1000 Hz) of the applied electric potential on particle response were assessed through experiments and mathematical modeling with COMSOL Multiphysics®. Particles of different sizes (100–1000 nm diameters) were introduced into iDEP devices fabricated from polydimethylsiloxane (PDMS) and their dielectrophoretic responses under direct and alternating current electric fields were recorded and analyzed in the form of images and videos. The results illustrated that particle polarizability and dielectrophoretic response depend greatly on particle size and the frequency of the electric field. Small particles tend to exhibit positive DEP at higher frequencies (200–1000 Hz), while large particles exhibit negative DEP at lower frequencies (20–200 Hz). These differences in relative polarization can be used for the design of iDEP‐based separations and analysis of particle mixtures.  相似文献   

15.
This work presents a microfluidic device, which was patterned with (i) microstructures for hydrodynamic capture of single particles and cells, and (ii) multiplexing microelectrodes for selective release via negative dielectrophoretic (nDEP) forces and electrical impedance measurements of immobilized samples. Computational fluid dynamics (CFD) simulations were performed to investigate the fluidic profiles within the microchannels during the hydrodynamic capture of particles and evaluate the performance of single‐cell immobilization. Results showed uniform distributions of velocities and pressure differences across all eight trapping sites. The hydrodynamic net force and the nDEP force acting on a 6 μm sphere were calculated in a 3D model. Polystyrene beads with difference diameters (6, 8, and 10 μm) and budding yeast cells were employed to verify multiple functions of the microfluidic device, including reliable capture and selective nDEP‐release of particles or cells and sensitive electrical impedance measurements of immobilized samples. The size of immobilized beads and the number of captured yeast cells can be discriminated by analyzing impedance signals at 1 MHz. Results also demonstrated that yeast cells can be immobilized at single‐cell resolution by combining the hydrodynamic capture with impedance measurements and nDEP‐release of unwanted samples. Therefore, the microfluidic device integrated with multiplexing microelectrodes potentially offers a versatile, reliable, and precise platform for single‐cell analysis.  相似文献   

16.
The present communication illustrates the use of simple electrokinetic devices for the assessment of the zeta potential of submicron polystyrene particles. A combination of manual and automatic particle tracking was employed. This approach allows for characterizing particles in the same conditions and devices in which they can be separated, e.g. dielectrophoretic separations; making the resulting data readily applicable.  相似文献   

17.
Microfluidic devices with three-dimensional (3-D) arrays of microelectrodes embedded in microchannels have been developed to study dielectrophoretic forces acting on synthetic micro- and nanoparticles. In particular, so-called deflector structures were used to separate particles according to their size and to enable accumulation of a fraction of interest into a small sample volume for further analysis. Particle velocity within the microchannels was measured by video microscopy and the hydrodynamic friction forces exerted on deflected particles were determined according to Stokes law. These results lead to an absolute measure of the dielectrophoretic forces and allowed for a quantitative test of the underlying theory. In summary, the influence of channel height, particle size, buffer composition, electric field, strength and frequency on the dielectrophoretic force and the effectiveness of dielectrophoretic deflection structures were determined. For this purpose, microfluidic devices have been developed comprising pairs of electrodes extending into fluid channels on both top and bottom side of the microfluidic channels. Electrodes were aligned under angles varying from 0 to 75 degrees with respect to the direction of flow. Devices with channel height varying between 5 and 50 microm were manufactured. Fabrication involved a dedicated bonding technology using a mask aligner and UV-curing adhesive. Particles with radius ranging from 250 nm to 12 microm were injected into the channels using aqueous buffer solutions.  相似文献   

18.
19.
Dielectrophoretic (DEP) force is exerted when a neutral particle is polarized in a non-uniform electric field, and depends on the dielectric properties of the particle and the suspending medium. The integration of DEP and microfluidic systems offers numerous applications for the separation, trapping, assembling, transportation, and characterization of micro/nano particles. This article reviews the applications of DEP forces in microfluidic systems. It presents the theory of dielectrophoresis, different configurations, and the applications of such systems for particle manipulation and device fabrication.  相似文献   

20.
This paper reports rapid microfluidic electrokinetic concentration of deoxyribonucleic acid (DNA) with the Joule heating induced temperature gradient focusing (TGF) by using our proposed combined AC and DC electric field technique. A peak of 480-fold concentration enhancement of DNA sample is achieved within 40 s in a simple poly-dimethylsiloxane (PDMS) microfluidic channel of a sudden expansion in cross-section. Compared to a sole DC field, the introduction of an AC field can reduce DC field induced back-pressure and produce sufficient Joule heating effects, resulting in higher concentration enhancement. Within such microfluidic channel structure, negative charged DNA analytes can be concentrated at a location where the DNA electrophoretic motion is balanced with the bulk flow driven by DC electroosmosis under an appropriate temperature gradient field. A numerical model accounting for a combined AC and DC field and back-pressure driven flow effects is developed to describe the complex Joule heating induced TGF processes. The experimental observation of DNA concentration phenomena can be explained by the numerical model.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号