首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In the present study, for the first time electromembrane extraction followed by high‐performance liquid chromatography coupled with ultraviolet detection was developed and validated for the determination of tartrazine in some food samples. The parameters influencing electromembrane extraction were evaluated and optimized. The membrane consists of 1‐octanol immobilized in the pores of a hollow fiber. As a driving force, a 30 V electrical field was applied to make the analyte migrate from sample solution with pH 3, through the supported liquid membrane into an acceptor solution with pH 10. Best preconcentration (enrichment factor >21) was obtained in extraction duration of 15 min. Effects of some solid nano‐sorbents like carbon nanotubes and molecularly imprinted polymers on membrane performance and electromembrane extraction efficiency were evaluated. The method provided the linearity in the range 25–1000 ng/mL for tartrazine (R2 > 0.9996) with repeatability range (RSD) between 3.8 and 8.5% (n = 3). The limits of detection and quantitation were 7.5 and 25 ng/mL, respectively. Finally, the method was applied to the determination and quantification of tartrazine from some food samples with relative recoveries in the range between 90 and 98%.  相似文献   

2.
In this study, the application of a mixture of organic solvents as a supported liquid membrane for improving the efficiency of the electromembrane extraction procedure was investigated. The extraction process was followed by high‐performance liquid chromatography analysis of two model drugs (verapamil and riluzole). In this research, four organic solvents, including 1‐heptanol, 1‐octanol, 2‐nitrophenyl octyl ether, and 2‐ethyl hexanol, were selected as model solvents and different binary mixtures (v/v 2:1, 1:1 and 1:2) were used as the supported liquid membrane. The mixture of 2‐ethyl hexanol and 1‐otanol (v/v, 2:1) improved the extraction efficiency of model drugs by 1.5 to 12 times. It was found that extraction efficiency is greatly influenced by the level of electric current. In this study, for various mixtures of organic solvents, the electric current fluctuated between 50 and 2500 μA, and the highest extraction efficiencies were obtained with low and stable electric currents. Finally, the optimized extraction condition was validated and applied for the determination of model drugs in urine and wastewater samples.  相似文献   

3.
A novel eco‐friendly and effective electromembrane extraction method combining high‐performance liquid chromatography with UV detection was developed for the enrichment and determination of capecitabine. Tragacanth‐silver nanoparticles conjugated gel was prepared by dissolving the tragacanth powder in synthesized silver nanoparticles solution and was used as a green membrane in electromembrane extraction. The porosity and presence of silver nanoparticles in the gel were characterized by field emission scanning electron microscopy. This new electromembrane extraction approach uses neither organic solvent nor carrier agents to extract the target analyte. The best electromembrane extraction efficiency was obtained by using 4.0 mm membrane gel thickness containing 2.5% w/v of tragacanth gum, donor phase pH = 5.0, acceptor phase pH = 3.0, applied voltage 50 V, extraction time 20 min, and agitation rate 500 rpm. During method validation under the optimized conditions, good linearity dynamic range between 1 and 500 ng/mL with the coefficient of determination (R2) = 0.998 was obtained. Limit of detection and Limit of quantitation were estimated to be 0.84 and 1.0 ng/mL, respectively. Finally, the applicability of this method in real samples was confirmed by an acceptable performance in extraction and determination of capecitabine in human plasma samples.  相似文献   

4.
Application of hollow fiber-based electromembrane extraction was studied for extraction and quantification of phenytoin from exhaled breath condensate (EBC). Phenytoin is extracted from EBC through a supported liquid membrane consisting of 1-octanol impregnated in the walls of a hollow fiber, and into an alkaline aqueous acceptor solution inside the lumen of the fiber. Under the obtained conditions of electromembrane extraction, that is, the extraction time of 15 min, stirring speed of 750 rpm, donor phase pH at 11.0, acceptor pH at 13.0, and an applied voltage of 15 V across the supported liquid membrane, an enrichment factor of 102-fold correspond to extraction percent of 25.5% was achieved. Good linearity was obtained over the concentration range of 0.001–0.10 µg/mL (r2 = 0.9992). Limits of detection and quantitation were 0.001 and 0.003 µg/mL, respectively. The proposed method was successfully applied to determine phenytoin from EBC samples of patients receiving the drug. No interfering peaks were detected that indicating excellent selectivity of the method. The intra- and interday precisions (RSDs) were less than 14%.  相似文献   

5.
A possibility of a combination of supported liquid membrane (SLM) and solid-phase extraction (SPE) for the determination of atrazine at microgram level in different type of fruit juices is presented. In comparison to SPE extraction from juice samples, the application of SLM-SPE enrichment provides much cleaner extracts and the possibility of lowering the limit of detection as low as 30 microg/l. However, it was also shown that by appropriate manipulation of SLM extraction conditions mainly flow-rate of donor phase and volume ratio between donor and acceptor phase, the level of detection can be further decreased to 10 microg/l. The results suggest that the application of SLM extraction prior to SPE is an alternative method for atrazine enrichment from complicated liquid matrices and could be used as routine method for the clean-up of such samples.  相似文献   

6.
In the present study, for the first time electromembrane extraction followed by high performance liquid chromatography coupled with ultraviolet detection was optimized and validated for quantification of four gonadotropin‐releasing hormone agonist anticancer peptides (alarelin, leuprolide, buserelin and triptorelin) in biological and aqueous samples. The parameters influencing electromigration were investigated and optimized. The membrane consists 95% of 1‐octanol and 5% di‐(2‐ethylhexyl)‐phosphate immobilized in the pores of a hollow fiber. A 20 V electrical field was applied to make the analytes migrate from sample solution with pH 7.0, through the supported liquid membrane into an acidic acceptor solution with pH 1.0 which was located inside the lumen of hollow fiber. Extraction recoveries in the range of 49 and 71% within 15 min extraction time were obtained in different biological matrices which resulted in preconcentration factors in the range of 82–118 and satisfactory repeatability (7.1 < RSD% < 19.8). The method offers good linearity (2.0–1000 ng/mL) with estimation of regression coefficient higher than 0.998. The procedure allows very low detection and quantitation limits of 0.2 and 0.6 ng/mL, respectively. Finally, it was applied to determination and quantification of peptides in human plasma and wastewater samples and satisfactory results were yielded.  相似文献   

7.
A simple electromembrane extraction (EME) procedure combined with ion chromatography (IC) was developed to quantify inorganic anions in different pure water samples and water miscible organic solvents. The parameters affecting extraction performance, such as supported liquid membrane (SLM) solvent, extraction time, pH of donor and acceptor solutions, and extraction voltage were optimized. The optimized EME conditions were as follows: 1‐heptanol was used as the SLM solvent, the extraction time was 10 min, pHs of the acceptor and donor solutions were 10 and 7, respectively, and the extraction voltage was 15 V. The mobile phase used for IC was a combination of 1.8 mM sodium carbonate and 1.7 mM sodium bicarbonate. Under these optimized conditions, all anions had enrichment factors ranging from 67 to 117 with RSDs between 7.3 and 13.5% (n = 5). Good linearity values ranging from 2 to 1200 ng/mL with coefficients of determination (R2) between 0.987 and 0.999 were obtained. The LODs of the EME‐IC method ranged from 0.6 to 7.5 ng/mL. The developed method was applied to different samples to evaluate the feasibility of the method for real applications.  相似文献   

8.
The simultaneous extraction of acidic and basic drugs from biological samples is a significant challenge for sample preparation. A novel and efficient method named dual hollow fibre electromembrane extraction combined with CE was applied for the simultaneous extraction and preconcentration of acidic and basic drugs in a single step. Under applied potential of 40 V during the extraction, ibuprofen as an acidic drug and thebaine as a basic drug migrated from a 4 mL aqueous sample solution at neutral pH into 20 μL of each basic (pH 12.5) and acidic (pH 2.0) acceptor phase, respectively; 1‐octanol and 2‐nitrophenyl octyl ether were immobilised in the pores of anodic and cathodic hollow fibres as supported liquid membranes, respectively. A Box–Behnken design and the response surface methodology were used for the optimisation of different parameters on the extraction efficiency. Under the optimised conditions, the enrichment factors were between 150 and 170 and also the LODs ranged from 3 to 7 ng/mL in different samples. The method was reproducible so that intra‐ and inter‐day RSDs% (n = 5) were less than 5.9%. Finally, the method was successfully applied for the simultaneous extraction and determination of acidic and basic drugs from plasma and urine samples.  相似文献   

9.
In this study, ionic liquid (IL) supported magnetic dispersive solid‐phase microextraction was developed and a systematic investigation was conducted on imidazolium ILs for their extraction performance. This nano‐based pretreatment procedure was then applied for the determination of acaricides in fruit juice samples for the first time. A feature of this technique is that the commonly laborious chemical modification of magnetic nanoparticles (MNPs) was skillfully circumvented. Because of the combination of ILs, dispersive liquid–liquid microextraction, and dispersive MNP solid‐phase microextraction, the extraction efficiency can be significantly improved using commercial MNPs. Parameters of the extraction method were investigated by one‐factor‐at‐a‐time approach. The optimal experimental conditions were as follows: emulsification for 2 min by sonication with the addition of 50 μL [C6MIM][NTf2] in the dispersive liquid–liquid microextraction step and vortexing for 90 s after adding 40 mg spherical barium ferrite nanoparticles (20 nm). The desorption time was 2 min. Good linearity (0.5–500 ng/mL) and detection limits within the range of 0.05–0.53 ng/mL were achieved. The application of the proposed method was demonstrated by the analysis of real fruit juice samples, in which recoveries between 85.1 and 99.6% were obtained.  相似文献   

10.
In this work, carbon‐nanotube‐assisted electromembrane extraction in the two‐phase mode combined with GC was developed for the preconcentration and determination of basic drugs in body fluids. The multiwalled carbon nanotubes dispersed in organic solvent are held in the pores of the porous fiber wall by capillary forces and sonification. The membrane with immobilized carbon nanotubes acts as a sorbent and provides an additional pathway for analyte transport. This study demonstrates that the immobilization of carbon nanotubes in the supported liquid membrane is an excellent approach to enhance the performance of the extraction. Optimization of the variables affecting this method was carried out in order to achieve the best extraction efficiency. Optimal extractions were accomplished with octanol as the extraction solvent, 50 V as the driving force and pH 7.4 in the sample solution with the whole assembly agitated at 1000 rpm for 20 min. Under the optimized extraction conditions, the proposed technique provided good linearity (R2 > 0.9990), repeatability (3.5–3.8%), low LODs (1.5 ng/mL), good preconcentration factors (292–316) and high recoveries (80–87%). Finally, this method was successfully used for the determination of tramadol and methadone in different body fluids including plasma and urine samples.  相似文献   

11.
Graphene‐based pipette tip solid‐phase extraction was combined with ultra‐high performance liquid chromatography and tandem mass spectrometry for the determination of carbamate pesticide residues in fruit juice samples. Four milligrams of graphene was used as sorbent material to pack a 1000 μL pipette tip for the extraction of pirimicarb, propoxur, isoprocarb, fenobucarb, and diethofencarb from 3 mL of fruit juice sample. The whole extraction process was finished in 12 min, and the volume of eluent used was only 1.5 mL. Under the optimized conditions, good linear relationship (R > 0.999) and lower limits of detection (0.0022–0.033 ng/mL) were achieved. The recoveries at three spiked levels ranged from 80.90 to 124.60% with relative standard deviations less than 4.88%. Compared with commercially available sorbents including propylsulfonic acid silica, graphitized carbon black, and C18, graphene was superior in extraction efficiency. The proposed method is simple, rapid, sensitive, selective, and solvent saving.  相似文献   

12.
In the present study, graphene oxide reinforced two‐phase electromembrane extraction (EME) coupled with gas chromatography was applied for the determination of methamphetamine as a model analyte in biological samples. The presence of graphene oxide in the hollow fiber wall can increase the effective surface area, interactions with analyte and polarity of support liquid membrane that leads to an enhancement in the analyte migration. To investigate the influence of the presence of graphene oxide in the support liquid membrane on the extraction efficiency, a comparative study was performed between graphene oxide and graphene oxide/EME methods. The extraction parameters such as type of organic solvent, pH of the donor phase, stirring speed, time, voltage, salt addition and the concentration of graphene oxide were optimized. Under the optimum conditions, the proposed microextraction technique provided low limit of detection (2.4 ng/mL), high preconcentration factor (195–198) and high relative recovery (95–98.5%). Finally, the method was successfully employed for the determination of methamphetamine in urine and hair samples.  相似文献   

13.
In this paper, for the first time, surfactant‐assisted electromembrane extraction coupled with capillary electrophoresis with UV detector was introduced for the extraction of acidic drugs from biological fluids. In this technique, in the presence of the nonionic surfactant in the donor phase, tendency of analyte ions into the supported liquid membrane (SLM) was increased. Naproxen and diclofenac were selected as model acidic drugs. In order to obtain the best extraction efficiency, several factors influencing the extraction efficiency were investigated. Optimal extractions were accomplished with 1‐octanol as the SLM, 15 Volt dc potential as the driving force, pH 12 in acceptor solution, and 0.2 mmol/L Triton X‐100 with pH 7.4 in donor solution. Equilibrium extraction conditions were obtained after 15 min of operation where the whole assembly agitated at 1000 rpm. Under the optimized conditions, preconcentration factors in the range of 176–184 and recoveries in the range of 88–92% were obtained. The applied method offers acceptable linearity with correlation coefficients higher than 0.9992. Limits of detection of 1.51 ng/mL and 2.42 ng/mL were obtained for naproxen and diclofenac, respectively. Finally, the developed method was successfully applied for the determination of naproxen and diclofenac in different matrices including plasma and urine samples.  相似文献   

14.
Surfactant‐assisted electromembrane extraction coupled with cyclodextrin‐modified capillary electrophoresis was developed for the separation and determination of Tranylcypromine enantiomers in biological samples. This combination would provide a new strategy for selective and sensitive determination of target analytes. The addition of surfactant in the donor solution improved the analyte transport into the lumen of hollow fiber that resulted in an enhancement in the analytes migration into acceptor solution. Optimization of the variables, affecting proposed method, was carried out and best results were achieved with a 175 V potential as driving force of the electromembrane extraction, 2‐nitrophenyloctylether as the supported liquid membrane, donor solution containing 0.2 mM Triton X‐100 with pH 3 and 0.1 M HCl for acceptor solution. Then, the extract was analyzed using cyclodextrin‐modified capillary electrophoresis method for separation of Tranylcypromine enantiomers. The best results were obtained with a phosphate running buffer (100 mM, pH 2.0) containing 7% w/v hydroxypropyl‐α‐cyclodextrin. Under the optimum conditions, a low limit of detection (3.03 ng/mL), good linearity (R2 > 0.9953), and relative standard deviations below 4.0% (n = 5) were obtained. Finally, this procedure was applied to determine the concentration of Tranylcypromine enantiomers in urine samples with satisfactory results.  相似文献   

15.
In this study, electromembrane extraction from a flowing sample solution, termed as continuous‐flow electromembrane extraction, was developed and compared with conventional procedures for the determination of four basic drugs in real samples. Experimental parameters affecting the extraction efficiency were further studied and optimized. Under optimum conditions, linearity of continuous‐flow procedure was within 8.0–500 ng/mL, while it was wider for conventional procedures (2.0–500 ng/mL). Moreover, repeatability (percentage relative standard deviation) was found to range between 5.6 and 10.4% (n  = 3) for the continuous‐flow procedure, with a better repeatability than that of conventional procedures (2.3–5.5% (n  = 3)). Also, for the continuous‐flow procedure, the estimated detection limit (signal‐to‐noise ratio = 3) was less than 2.4 ng/mL and extraction recoveries were within 8–10%, while the corresponding figures for conventional procedures were less than 0.6 ng/mL and 42–60%, respectively. Thus, the results showed that both continuous flow and conventional procedures were applicable for the extraction of model compounds. However, the conventional procedure was more convenient to use, and thus it was applied to determine sample drugs in real urine and wastewater samples.  相似文献   

16.
In the present work, pulsed electromembrane extraction (PEME) was performed for the first time, as a new concept of electrically enhanced microextraction method, for extraction and quantification of histidine, phenylalanine and tryptophan in different matrices. PEME offers an alternative to conventional electromembrane extraction (EME), which faces problems such as serious instabilities in the analysis of real samples with high concentration levels of ions. In these samples, increasing of the ion transportation across the liquid membrane results in Joule heating during the extraction process which may follow by punctuation of the organic membrane, increasing of the current level and bubble formation due to electrolysis reactions. A mixture of 2-nitrophenyl octyl ether (NPOE), di-(2-ethylhexyl) phosphate (DEHP) and tris-(2-ethylhexyl) phosphate (TEHP) was immobilized in the pores of hollow fiber as the organic liquid membrane. Other effective parameters such as extraction time, ion balance and pulse frequency were optimized using the experimental design. Extraction recoveries in the range of 7.1–21.6% and satisfactory repeatability (2.1 < CV% < 4.5) were obtained. Limits of detection were 5, 10 and 30 ng mL−1 for tryptophan, phenylalanine and histidine, respectively. The method offers acceptable linearity with correlation coefficients higher than 0.9979. Furthermore, the figures of merit of PEME are compared with the results from conventional electromembrane extraction (EME), which proves the advantages of the proposed technique. The method was applied to the determination and quantification of amino acids in foods and biological samples. Also, two-way PEME was employed as a novel approach for highly selective extraction of tryptophan as a model analyte to introduce an interesting ability of the proposed technique.  相似文献   

17.
For the first time, electromembrane extraction combined with liquid chromatography and tandem mass spectrometry was applied for the determination of urinary benzene, toluene, ethylbenzene, and xylene metabolites. S‐Phenylmercapturic acid, hippuric acid, phenylglyoxylic acid, and methylhippuric acid isomers were extracted from human urine through a supported liquid membrane consisting of 1‐octanol into an alkaline acceptor solution filling the inside of a hollow fiber by application of an electric field. Various extraction factors were investigated and optimized using response surface methodology, the statistical method. The optimum conditions were established to be 300 V applied voltage, 15 min extraction time, 1500 rpm stirring speed, and 5 mM ammonium acetate (pH 10.2) acceptor solution. The method was validated with respect to selectivity, linearity, accuracy, precision, limit of detection, limit of quantification, recovery, and reproducibility. The results showed good linearity (r2 > 0.995), precision, and accuracy. The extract recoveries were 52.8–79.0%. Finally, we applied this method to real samples and successfully measured benzene, toluene, ethylbenzene, and xylene metabolites.  相似文献   

18.
An analytical protocol that includes solid‐phase purification and extraction is successfully developed for the determination of trace neonicotinoid pesticides in tea infusion. The method consists of a purification on amino‐functionalized mesoporous silica SBA‐15 followed by a solid‐phase extraction based on graphene oxide before ultra high performance liquid chromatography with tandem mass spectrometry analysis. Parameters that significantly affected the extraction of the neonicotinoids onto graphene oxide, such as the amount of adsorbent, extraction time, pH, elution solvent, etc. were optimized. The amino‐functionalized mesoporous silica SBA‐15 has been proved to be an efficient adsorbent for removal of polyphenols especially catechins from tea infusion. Graphene oxide exhibits a very rapid adsorption rate (within 10 min) and high adsorption capacities for neonicotinoids at low initial concentration (0.01–0.5 mg/L). The analysis method gave a good determination coefficient (r2 > 0.99) for each pesticide and high recoveries in the range of 72.2–95.0%. Powder X‐ray diffraction, Raman spectroscopy, transmission electron microscopy, and UV‐vis spectroscopy were utilized to identify the structure and morphology of graphene oxide. The adsorption driving force of neonicotinoids on graphene oxide mainly depends on π–π electron donor–acceptor interaction and electrostatic interaction.  相似文献   

19.
A new robust method of electromembrane‐surrounded solid‐phase microextraction coupled to ion mobility mass spectrometry was applied for nonsteroidal anti‐inflammatory drugs determination in complex matrices. This is the first time that a graphene/polyaniline composite coating is applied in electromembrane‐surrounded solid‐phase microextraction method. The homemade graphene/polyaniline composite is characterized by a high electrical conductivity and thermal stability. The variables affecting electromembrane‐surrounded solid‐phase microextraction, including extraction time; applied voltage and pH were optimized through chemometric methods, central composite design, and response surface methodology. Under the optimized conditions, limits of detection of 0.04 and 0.05 ng/mL were obtained for mefenamic acid and ibuprofen, respectively. The feasibility of electromembrane‐surrounded solid‐phase microextraction followed by ion mobility mass spectrometry was successfully confirmed by the extraction and determination of low levels of ibuprofen and mefenamic acid in human urine and plasma samples and satisfactory results were obtained.  相似文献   

20.
Electromembrane extraction using a polypropylene hollow fiber impregnated with 1‐ethyl‐2‐nitrobenzene was evaluated for the extraction and preconcentration of the fungicides thiabendazole and carbendazim from water samples before capillary electrophoresis analysis. The composition of the supported liquid membrane, the HCl concentration in the acceptor solution, and the stirring rate (of the donor solution) were optimized using the one‐variable‐at‐a‐time method. In contrast, a face‐centered central composition design was used for optimization of voltage, extraction time, and concentration of HCl in the donor solution. After optimization, electromembrane extraction provided enrichment factors of 50 and 26 for thiabendazole and carbendazim that allowed us to achieve limits of detection of 1.1 and 2.3 μg/L, respectively. Repeatability (intraday precision) expressed as the relative standard deviation varied from 2.5 to 2.8%, while the interday precision ranged from 3.1 to 3.3%. The proposed method was applied for analysis of samples of tap and river water, and acceptable precision and accuracy were attained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号