首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
A multiresidue method has been developed and validated for the simultaneous determination of organophosphorus insecticides and their toxic metabolites in sugarcane juice and refined sugar by gas chromatography with flame photometric detection. Limits of quantification of the method varied between 0.007 and 0.01 μg/g. Ethyl acetate based extraction followed by dispersive solid‐phase extraction cleanup with primary secondary amine yielded internationally acceptable recoveries of acephate, chlorpyrifos, dichlorvos, monocrotophos, malathion, malaoxon, phorate, phorate‐sulfoxide, phorate‐oxon, phorate‐sulfone, and quinalphos from selected matrices. The recoveries of target analytes from cane juice were 75.55 ± 0.5–102.57 ± 4.2, 77.45 ± 4.7–103.33 ± 3.3, and 80.55 ± 6.6–105.82 ± 9.8% at 0.01, 0.02, and 0.1 μg/g levels of fortification, respectively. The recoveries from cane sugar were 73.24 ± 3.5–104.47 ± 1.9, 75.23 ± 1.5–116.10 ± 3.7, and 70.75 ± 5.7–110.15 ± 2.7%, respectively at 0.01, 0.02, and 0.1 μg/g levels of fortification. Matrix effect and measurement uncertainty were within the permissible limit (less than 20%) as prescribed for pesticide residue analysis.  相似文献   

2.
In this study, a gas‐assisted dispersive liquid‐phase microextraction method using a deep eutectic solvent as the extraction solvent combined with gas chromatography and flame ionization detection was developed for the extraction and determination of some pesticide residues in vegetable and fruit juice samples. In this method, choline chloride and 4‐chlorophenol at a molar ratio of 1:2 were mixed. By heating and vortexing, a clear, water‐immiscible, and homogeneous liquid was formed. The obtained deep eutectic solvent was added to an aqueous solution of the analytes in a conical test tube. Air was bubbled into the aqueous solution and a cloudy solution was obtained. During this step, the analytes were extracted into the fine droplets of the extraction solvent. After centrifugation, an aliquot of the settled phase was injected into the separation system. Under the optimum extraction conditions, enrichment factors, and extraction recoveries were obtained in the ranges of 247–355 and 49–71%, respectively. The obtained values for the limits of detection and quantification were in the ranges of 0.24–1.4 and 0.71–4.2 μg/L, respectively. The proposed method is simple, fast, efficient, and inexpensive.  相似文献   

3.
This work is the first study on the extraction efficiency of self‐doped polyaniline that is immobilized on the graphene‐modified magnetic nanoparticles. The new material was used as a sorbent for the magnetic solid‐phase extraction of methyl‐, propyl‐, and butylparabens. The use of graphene provides a high surface area and prevents aggregation of the nanoparticles. The self‐doped polyaniline also provides multifunctionality, high extraction capacity, and chemical stability even in the basic medium. The parabens were acetylated for determination by gas chromatography with flame ionization detection. The effects of monomer ratio, extraction solvent, sorbent amount, sample volume, desorption solvent volume, adsorption and desorption times, and sample ionic strength were optimized. Preconcentration factors obtained were from 190 to 310. The detection limits of the method were <2.8 μg/L. Linear ranges of the method were 5–2000 μg/L for propyl and butyl parabens, and 10–2000 μg/L for methyl paraben. The method was applied for the determination of the parabens in cosmetic products and extraction recoveries were 89–101% with RSDs ≤7.9%.  相似文献   

4.
A procedure for multiresidue analysis was developed for the extraction and determination of 17 pesticides, including herbicides, fungicides, and insecticides, as well as certain degradation products, in vineyard soils from La Rioja region (Spain). Different solvents and mixtures were tested in spiked pesticide‐free soils, and pesticides were comparatively evaluated by gas chromatography with mass spectrometry and liquid chromatography with mass spectrometry. Recoveries >70%, with relative standard deviations <9%, were obtained when a mixture of methanol/acetone or a mixture of methanol/CaCl2 0.01 M for the most polar compounds was selected as the extraction solvent. Method validation was accomplished with acceptable linearity (r2 ≥ 0.987) within the concentration range of 0.005–1 μg/mL corresponding to 1.667–333.4 μg/kg and 0.835–167.1 μg/kg for liquid chromatography with mass spectrometry and gas chromatography with mass spectrometry, respectively, and detection limits <0.4 μg/kg for the compounds were studied. The extraction method was applied to 17 real vineyard soil samples, and terbuthylazine and its metabolite desethylterbuthylazine were the most ubiquitous compounds, as they were detected in the 100% of the soils analyzed. The presence of fungicides was also high, and the presence of insecticides was lower than other pesticides. The results confirm the usefulness of the optimized procedure for monitoring residues in vineyard soils.  相似文献   

5.
A new solid‐phase extraction (SPE) pretreatment method using a home‐made polyvinylpolypyrrolidone‐florisil (PVPP‐F) column was developed for the analysis of patulin in apple and hawthorn products in China. Fifty samples (25 apple juices, 12 apple jams, and 13 hawthorn juices) were prepared using the new method and then analyzed by high performance liquid chromatography with diode array detection (HPLC‐DAD) on an Agela Venusil MP C18 reversed‐phase column (4.6 mm × 250 mm, 5 μm). The cleanup results for all samples using home‐made PVPP‐F column were compared with those obtained using a MycoSep®228 AflaPat column. The correlation coefficient R (0.9998) fulfilled the requirement of linearity for patulin in the concentration range of 2.5–250 μg/kg. The limits of detection (LODs) and quantification (LOQs) of patulin were 3.99 and 9.64 μg/kg for PVPP‐F column, and 3.56 and 8.07 μg/kg for MycoSep®228 AflaPat column, respectively. Samples were spiked with patulin at levels ranging from 25 to 250 μg/kg, and recoveries using PVPP‐F and MycoSep®228 AflaPat columns were in the range of 81.9–100.9% and 86.4–103.9%, respectively. Naturally occurring patulin was found in 2 of 25 apple juice samples (8.0%) and 1 of 13 hawthorn juice samples (7.7%) at concentrations ranging from 12.26 to 36.81 μg/kg. The positive results were further confirmed by liquid chromatography electrospray ionization mass spectrometry (LC‐ESI‐MS).  相似文献   

6.
建立了果汁蔬菜中8种苯甲酰脲类(杀虫脲、氟苯脲、氟虫脲、氟啶脲、除虫脲、氟铃脲、灭幼脲、氟丙氧脲)农药残留量的液相色谱-电喷雾串联质谱(LC-ESI MS/MS)测定方法。样品用乙腈提取后无需净化,经盐析过滤并以水稀释(1∶1)后,经Waters Atlantis(d C18色谱柱分离,5 mmol/L乙酸铵水溶液和乙腈梯度洗脱,以电喷雾电离串联质谱在负离子多反应监测(MRM)模式下进行测定并确证,外标法定量。8种苯甲酰脲类农药在1.0~100μg/L范围内线性良好,相关系数为0.990 0~0.999 9。对8种农药在毛豆基质中3个添加水平下的回收率进行测定,平均回收率为92%~110%,相对标准偏差为5.5%~12%。方法的检出限(S/N=3)为0.04~0.42μg/kg,定量下限(S/N=10)为0.2~1.5μg/kg。  相似文献   

7.
胡贝贞  宋伟华  谢丽萍  邵铁锋 《色谱》2008,26(5):608-612
建立了含硫蔬菜(大葱、大蒜、蒜薹及韭菜等)中14种农药残留的气相色谱-负化学离子源质谱(GC-NCI/MS)检测方法。样品先采用微波加热处理除去大部分的含硫干扰物,然后用乙腈均质提取,提取液用凝胶渗透色谱(GPC)和N-丙基乙二胺(PSA)固相萃取小柱净化后用GC-NCI/MS在选择离子监测模式下测定。在50 μg/kg加标水平下回收率为49.2%~113.1%,相对标准偏差为1.42%~8.70%,检出限(以3倍信噪比计)为0.5~10.0 μg/kg。方法的选择性好,抗干扰能力强,能消除复杂基质带来的干扰,适合于含硫蔬菜中农药残留的确证分析。  相似文献   

8.
A new analytical method for the determination of organophosphorus pesticides in cereal samples was developed by combining dispersive SPE (d‐SPE) and salting‐out homogeneous liquid–liquid extraction (SHLLE). The pesticides were first extracted from cereal grains with acetonitrile, followed by d‐SPE cleanup. A 2 mL aliquot of the extract was then added to a centrifuge tube containing 9.2 mL water and 3.3 g NaCl for SHLLE. Analysis of the extract was carried out by gas chromatography coupled with flame photometric detection. The d‐SPE procedure effectively provides the necessary cleanup of the extract while SHLLE is used as an efficient concentration technique. Experimental parameters influencing the extraction efficiency including amounts of added water and salt were investigated. Recovery studies were carried out at three fortification levels, yielding recoveries in the range of 57.7–98.1% with the RSD from 3.7 to 10.9%. The reported limits of determination obtained from this study were 1 μg/kg, which is better than the conventional methods. In the analysis of 40 wheat and corn samples taken from Beijing suburbs, only two wheat samples have chlorpyrifos residue over the limits of determination.  相似文献   

9.
离心沉淀气相色谱法测定面粉中过氧化苯甲酰含量的研究   总被引:2,自引:0,他引:2  
建立了离心沉淀,气相色谱氢火焰离子化检测器测定面粉中过氧化苯甲酰含量的方法。考察了不同提取时间和采用不同工作曲线对过氧化苯甲酰测定的影响。试样在石油醚中被冰乙酸还原成苯甲酸,经HP-5(30m&#215;0.25mm&#215;0.25μm)毛细管气相色谱柱分离,氢火焰离子化检测器测定。方法的线性范围为0.005~0.08g/L(r=0.9992),检出限(S/N=3)为2mg/kg。在添标水平为0.06、0.18和0.30g/kg时的平均回收率为82.70%~89.46%,相对标准偏差为3.77%~6.93%。该方法仪器设备简单,测定结果灵敏、准确,适合面粉中过氧化苯甲酰的测定。  相似文献   

10.
A method based on direct immersion solid‐phase microextraction (DI‐SPME) coupled with high performance liquid chromatography combined with post‐column photochemically induced fluorimetry derivatization and fluorescence detection (HPLC‐PIF‐FD) was developed to extract three pyrethroid insecticides, i.e. cyfluthrin, cypermethrin, and flumethrin from water samples. A sol‐gel based coating fiber using 3‐(trimethoxysilyl propyl) amine as precursor was prepared and used for the extraction of the pyrethroids from groundwater samples. A post‐column photochemical reactor was designed and constructed for the derivatization of these environmentally important pollutants to increase their fluorescence sensitivity and determination in HPLC. The parameters affecting extraction process (extraction time and temperature, pH, salt addition, and co‐solvent) and desorption step (solvent, desorption time, and temperature) of the analytes from the sol‐gel‐based fiber, along with photochemical reaction conditions were investigated. The developed method proved to be relatively rapid, simple, and easy and offers high sensitivity and reproducibility. Linear dynamic ranges (LDR) for these insecticides were ranged between 0.25 to 50 μg/L. The regression coefficients were satisfactory (R2 > 0.984) for these pyrethroids. The limits of detection and limits of quantification varied between 0.09 and 0.35 μg/L and 0.25 and 1.00 μg/L, respectively. Relative standard deviation RSDs values varied between 4.41% and 6.20%. Relative recoveries obtained from analysis of Jajroud river water sample ranged between 94% and 104%.  相似文献   

11.
Solid‐phase extraction (SPE) in tandem with dispersive liquid–liquid microextraction (DLLME) has been developed for the determination of mononitrotoluenes (MNTs) in several aquatic samples using gas chromatography‐flame ionization (GC‐FID) detection system. In the hyphenated SPE‐DLLME, initially MNTs were extracted from a large volume of aqueous samples (100 mL) into a 500‐mg octadecyl silane (C18) sorbent. After the elution of analytes from the sorbent with acetonitrile, the obtained solution was put under the DLLME procedure, so that the extra preconcentration factors could be achieved. The parameters influencing the extraction efficiency such as breakthrough volume, type and volume of the elution solvent (disperser solvent) and extracting solvent, as well as the salt addition, were studied and optimized. The calibration curves were linear in the range of 0.5–500 μg/L and the limit of detection for all analytes was found to be 0.2 μg/L. The relative standard deviations (for 0.75 μg/L of MNTs) without internal standard varied from 2.0 to 6.4% (n=5). The relative recoveries of the well, river and sea water samples, spiked at the concentration level of 0.75 μg/L of the analytes, were in the range of 85–118%.  相似文献   

12.
In this research, a new solid‐phase microextraction fiber based on carbon ceramic composites with copper nanoparticles followed by gas chromatography with flame ionization detection was applied for the extraction and determination of some nitro explosive compounds in soil samples. The proposed method provides an overview of trends related to synthesis of solid‐phase microextraction sorbents and their applications in preconcentration and determination of nitro explosives. The sorbents were prepared by mixing of copper nanoparticles with a ceramic composite produced by mixture of methyltrimethoxysilane, graphite, methanol, and hydrochloric acid. The prepared sorbents were coated on copper wires by dip‐coating method. The prepared nanocomposites were evaluated statistically and provided better limits of detection than the pure carbon ceramic. The limit of detection of the proposed method was 0.6 μg/g with a linear response over the concentration range of 2–160 μg/g and square of correlation coefficient >0.992. The new proposed fiber has been demonstrated to be a suitable, inexpensive, and sensitive candidate for extraction of nitro explosive compounds in contaminated soil samples. The constructed fiber can be used more than 100 times without the need for surface generation.  相似文献   

13.
An ultrasound‐assisted, hybrid ionic liquid, dispersive liquid–liquid microextraction method coupled to high‐performance liquid chromatography with a variable‐wavelength detector was developed to detect ten insecticides, including diflubenzuron, triflumuron, hexaflumuron, flufenoxuron, lufenuron, diafenthiuron, transfluthrin, fenpropathrin, γ‐cyhalothrin and deltamethrin, in fruit juices. In this method, an appropriate extraction solvent was chosen based on the partition coefficient of the target compounds. A mixture of 1‐octyl‐2,3‐dimethylimidazolium bis(trifluoromethylsulfonyl)imide and 1‐hexyl‐3‐methylimidazolium bis(trifluoromethylsulfonyl)imide was used as the extractant. The extraction efficiency was screened using Plackett–Burman design and optimized using central composite design. Under the optimal conditions, good linearity was obtained for all the analytes in the pure water model and the fruit juice samples. In pure water, the recoveries of the ten insecticides ranged from 85.7 to 108.9%, with relative standard deviations for one day ranging from 1.24 to 2.64%. The limits of detection were in the range of 0.19–0.69 μg/L, and the enrichment factors were in the range of 123–160. The logarithm of the n‐octanol/water partition coefficient in this experiment is a useful reference to select a suitable extraction solvent, and the proposed technique was applied for the analysis of ten insecticides in fruit juice with satisfactory results.  相似文献   

14.
In the present study, a rapid, simple, and highly efficient sample preparation method based on air‐assisted liquid–liquid microextraction followed by gas chromatography with flame ionization detection was developed for the extraction, preconcentration, and determination of five triazole pesticides (penconazole, hexaconazole, diniconazole, tebuconazole, and triticonazole) in edible oils. Initially, the oil samples were diluted with hexane and a few microliter of a less soluble organic solvent (extraction solvent) in hexane was added. To form fine and dispersed extraction solvent droplets, the mixture of oil sample solution and extraction solvent is repeatedly aspirated and dispersed with a syringe. Under the optimum extraction conditions, the method showed low limits of detection and quantification between 2.2–6.1 and 7.3–20 μg/L, respectively. Enrichment factors and extraction recoveries were in the ranges of 71–96 and 71–96%, respectively. The relative standard deviations for the extraction of 100 and 250 μg/L of each pesticide were less than 5% for intraday (n = 6) and interday (n = 3) precisions. Finally edible oil samples were successfully analyzed using the proposed method, and hexaconazole was found in grape seed oil.  相似文献   

15.
Polyaniline nanofiber films were fabricated on the surface of stainless steel wire via a controllable and simple electrophoretic deposition route from a nonaqueous colloidal suspension consisting of polyaniline nanofibers. The prepared coating material was then characterized by field emission scanning electron microscopy equipped with energy dispersive spectroscopy and elemental mapping analysis. The fabricated polyaniline film-coated stainless steel wire was then utilized as an effective and novel sorbent phase for solid-phase microextraction of tamoxifen for subsequent gas chromatography/flame ionization detection of this anticancer drug. Parameters consisting of the temperature, extraction time, salt concentration, agitation speed, pH, temperature and time of desorption were studied and optimized using a one-at-a-time strategy. Under the optimum conditions, detection limit (S/N = 3), the limit of quantification (10/3 limit of detection), linear dynamic range, repeatability and reproducibility values of 0.51 μg L−1, 1.7 μg L−1, 2–1,130 μg L−1, 5.7% and 8.6% were attained, respectively. The prepared fiber can preserve 90% of its efficacy after 20 consecutive cycles, demonstrating the suitable thermal stability and cyclability of the proposed solid-phase microextraction coating material for the determination of tamoxifen by gas chromatography/flame ionization detection. The route was effectively utilized to determine tamoxifen in urine samples, with relative recoveries ranging from 89 to 106%.  相似文献   

16.
A novel nanostructured copper‐based solid‐phase microextraction fiber was developed and applied for determining the two most common types of phthalate environmental estrogens (dibutyl phthalate and diethylhexyl phthalate) in aqueous samples, coupled to gas chromatography with flame ionization detection. The copper film was coated onto a stainless‐steel wire via an electroless plating process, which involved a surface activation process to improve the surface properties of the fiber. Several parameters affecting extraction efficiency such as extraction time, extraction temperature, ionic strength, desorption temperature, and desorption time were optimized by a factor‐by‐factor procedure to obtain the highest extraction efficiency. The as‐established method showed wide linear ranges (0.05–250 μg/L). Precision of single fiber repeatability was <7.0%, and fiber‐to‐fiber repeatability was <10%. Limits of detection were 0.01 μg/L. The proposed method exhibited better or comparable extraction performance compared with commercial and other lab‐made fibers, and excellent thermal stability and durability. The proposed method was applied successfully for the determination of model analytes in plastic soaking water.  相似文献   

17.
A simple and reliable method of ultra high performance liquid chromatography coupled with photo‐diode array detection has been proposed for the simultaneous determination of deoxynivalenol and its acetylated derivatives in wheat flour and rice, especially focusing on the optimization of sample extraction, cleanup, and chromatographic separation conditions. Sample pretreatment consisted of a first step using a quick, easy, cheap, effective, rugged, and safe based extraction procedure and a subsequent cleanup step based on solid‐phase extraction. The method was extensively validated in wheat flour and rice, obtaining satisfactory analytical performance with good linearity (R2 ≥ 0.999), acceptable recoveries (80.0–104.4%), and repeatability (RSDs 1.3–10.7%). The limits of detection (21.7–57.4 μg/kg) and quantitation (72.3–191.4 μg/kg) for deoxynivalenols were lower than those usually permitted by various countries’ legislation in these food matrices. The method was applied to 34 wheat and rice samples. The results were further compared with results of ultra high performance liquid chromatography with electrospray ionization tandem mass spectrometry.  相似文献   

18.
以Na4EDTA为络合剂,以五氟苄基溴为衍生试剂,采用快速溶剂萃取仪萃取,同时实现土壤酸性除草剂的络合萃取在线衍生,并以气相色谱-质谱(NCI源)进行检测。对络合条件、衍生条件、萃取条件、离子源选择进行了优化。方法的回收率为75%~95%、相对标准偏差为6.7%~13%、检测限2.8~8.4μg/Kg。  相似文献   

19.
This work describes solid-phase extraction-ultra-performance liquid chromatography with electrospray ionization tandem spectrometry for determination of malachite green and metabolite leucomalachite green, crystal violet and metabolite leucocrystal violet, methylene blue and metabolites including azure A, azure B and azure C in aquatic products. Samples were extracted with acetonitrile and ammonium acetate buffer and purified by liquid extraction with dichloromethane, and then on MCAX solid-phase extraction cartridges. Then the extract was evaporated at 45°C by nitrogen blow. The residue was dissolved and separated by an Acquity BEH C18 column. The mobile phase was acetonitrile (A) and 5 mmol/L of ammonium acetate containing 0.1% formic acid (B). Analytes were confirmed and quantified using a tandem mass spectrometry system in multiple reaction mode with triple quadrupole analyzer using positive polarity mode. The limits of detection of malachite green, leucomalachite green, crystal violet and leucocrystal violet were 0.15 μg/kg, the limits of quantification were 0.50 μg/kg, and the average recoveries were more than 75% with spiked residues from 0.5 to 10 μg/kg. The relative standard deviations were less than 13%. The limits of detection of methylene blue, azure A, azure B and azure C were 0.3 μg/kg, the limits of quantification were 1.0 μg/kg, the average recoveries were more than 70% with spiked residues from 1.0 to 10 μg/kg and the relative standard deviations were less than 15%. The method has the merits of simplicity, sensitivity and rapidity, and can be used for simultaneous determination of the analytes in aquatic products.  相似文献   

20.
In this study, a simple, rapid and efficient method, homogeneous liquid‐liquid microextraction via flotation assistance (HLLME‐FA) combined with gas chromatography – flame ionization detection (GC‐FID), for the determination of chlorobenzenes (CBs) in water samples, has been described. In this research, a special extraction cell was designed to facilitate collection of the low‐density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added into the extraction cell which contained an appropriate mixture of extraction and homogeneous solvents. By using air flotation, the organic solvent was collected at the conical part of the designed cell. Parameters affecting extraction efficiency were investigated and optimized. Under the optimum conditions, the detection limits, the precisions and the linearity of the method were found in the range of 0.2 to 1.5 µg L‐1, 5.7–9.3% (RSD, n =5) and 0.5–200 µg L‐1, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号