首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Silk fibers were carbonized to develop a biomass carbon material as an adsorbent for solid‐phase microextraction. The surface structure of the carbonized silk fibers was characterized by scanning electron microscopy, and the graphitization degree was determined by Raman spectrometry. After carbonization under high temperature, the orderliness and structural regularity of carbon atoms on silk fibers were promoted. Extraction tube packed with carbonized silk fibers was prepared for in‐tube solid‐phase microextraction. Coupled with high performance liquid chromatography, it exhibited good extraction performance for hydrophobic polycyclic aromatic hydrocarbons. Main parameters including sampling volume, sampling rate, methanol content in sample, and desorption time were systematically investigated. Under the optimum conditions, the analysis method was established and it exhibited wide linear range (0.016–20 μg/L) with good linearity (correlation coefficient ≥ 0.9947), low limits of detection (0.005–0.050 μg/L), and high enrichment factors (1189–2775). Relative standard deviations (n = 3) for intraday (≤3.3%) and interday (≤9.6%) tests indicated that the extraction material had satisfactory repeatability. Finally, the analytical method was successfully applied to detect trace polycyclic aromatic hydrocarbons in real water samples, demonstrating its satisfactory practicability.  相似文献   

2.
Nano‐molybdenum trioxide was prepared from nano‐molybdenum disulfide by simple firing in muffle furnace. Nano‐molybdenum trioxide was used as the extraction coating on the stainless steel wire. Four wires were filled in a polyetheretherketone tube to get an extraction tube. The tube was connected to the six‐port valve of a high performance liquid chromatograph, and the online analysis system was constructed. Extraction selectivity of the tube for different types of compounds, including polycyclic aromatic hydrocarbons, plasticizers, estrogens, anilines and neonicotinoids, was studied. Good enrichment ability for polycyclic aromatic hydrocarbons, but the extraction efficiency of others was not satisfactory. Using eight polycyclic aromatic hydrocarbons as the targets, an analytical method was established after optimizing main factors such as sampling volume, sampling rate, methanol content, and desorption time. The established method exhibited wide linear range to 0.016–20.00 μg/L and low limits of detection to 0.005 μg/L, and the enrichment factors can be up to 2443. The method was applied to the detection of trace polycyclic aromatic hydrocarbons in tap water and river water, and a good recovery was obtained. The tube showed good durability and chemical stability, and it still remained good extraction effect after more than 140 run.  相似文献   

3.
Triazine‐based organic polymers@SiO2 nanospheres were prepared and applied as an extraction coating onto stainless steel wires and the wires were filled into polyetheretherketone tube for in‐tube solid‐phase microextraction. Taking polycyclic aromatic hydrocarbons as targets, main factors affecting extraction performance of the tube were investigated through coupling to high performance liquid chromatography. Under the optimum conditions, an online analytical method for polycyclic aromatic hydrocarbons was established with large linear ranges (0.010‐20 µg/L), low limits of detection (0.003‐0.010 µg/L), high enrichment factors (533‐2954), and good repeatability (relative standard deviations <1.7% for intraday test, <5.0% for interday test). The analysis method was successfully applied to the detection of trace targets in real water samples and the relative recoveries ranged from 82.9 to 119.9%, which demonstrated the applicability of extraction tube in sample preparation.  相似文献   

4.
Natural cotton fiber was applied as a green extraction material for in‐tube solid‐phase microextraction. Cotton fibers were characterized by scanning electron microscope. A bundle of cotton fibers (685 mg, 20 cm) was directly packed into a polyetheretherketone tube (i.d. 0.75 mm) to get the extraction device. It was connected into high performance liquid chromatography, building an online extraction and dectection system. Through the online analysis system, several polycyclic aromatic hydrocarbons were used as the targets to evaluate the extraction performace of the device. In order to get high extraction efficiency and sensitivity, the extraction and desorption conditions were optimized. Under the optimum conditions, the sensitive analysis method was established, and provided low limits of detection of 0.02 and 0.05 μg/L, good linearity ranges of 0.06–15 and 0.16–15 μg/L, as well as high enrichment factors of 176–1868. The method was applied to the online determination of trace polycyclic aromatic hydrocarbons in snow water and river water, and the relative recoveries corresponding to 2 and 5 μg/L were in the range of 80–116%. The repeatability of extraction and preparation of the device was investigated and the relative standard deviations (n = 3) were less than 3.6 and 5.2%.  相似文献   

5.
A bonding method was developed for coating molybdenum oxides onto a steel wire substrate, which was used as a solid‐phase microextraction fiber, was coupled with gas chromatography. Based on the characterization, it is found that the as‐prepared molybdenum oxides material contained a nanobelt structure with a uniform size and good dispersibility. In addition, there were a large number of small protrusions on the surface of the nanobelts. These characteristics provided a large specific surface area for extraction. Molybdenum oxides exhibited a high extraction selectivity for polycyclic aromatic hydrocarbons owing to its moderate coordination. After the optimization of the factors, method detection limits of < 1.25 μg/L were achieved, and the calibration curves were linear within the range of 2–600 μg/L. In addition, repeatability was demonstrated, and the relative standard deviation < 6.4%. The molybdenum oxides coating had a high scratch resistance, which could effectively prevent coating wear and failure. Combined with the high thermal and chemical stability, the service life of the coating was improved and could be used 150 times without a significant reduction in the extraction performance. Finally, the as‐prepared fiber had a comparable extraction capacity and higher partition coefficients that those of commercial polyacrylate fibers.  相似文献   

6.
A solid‐phase microextraction with carbon nanospheres coated fiber coupled with gas chromatographic detection was established for the determination of eight polycyclic aromatic hydrocarbons (naphthalene, biphenyl, acenaphthene, fluorine, phenanthrene, anthracene, fluoranthene, and pyrene) in water and soil samples. The experimental parameters (extraction temperature, extraction time, stirring rate, headspace volume, salt content, and desorption temperature) which affect the extraction efficiency were studied. Under the optimized conditions, good linearity between the peak areas and the concentrations of the analytes was achieved in the concentration range of 0.5‐300 ng/mL for water samples, and in the concentration range of 6.0‐2700 ng/g for soil samples. The detection limits for the analytes were in the range of 0.12‐0.45 ng/mL for water samples, and in the range of 1.53‐2.70 ng/g for soil samples. The method recoveries of the polycyclic aromatic hydrocarbons for spiked water samples were 80.10‐120.1% with relative standard deviations less than 13.9%. The method recoveries of the analytes for spiked soil samples were 80.40‐119.6% with relative standard deviations less than 14.4%. The fiber was reused over 100 times without a significant loss of extraction efficiency.  相似文献   

7.
Ionic liquids have been widely used in different fields by advantage of their specific properties. In this work, 1‐methyl‐3‐(3‐trimethoxysilyl propyl)imidazolium chloride was prepared and chemically bonded onto basalt fibers for in‐tube solid‐phase microextraction. Through combining in‐tube extraction device with high‐performance liquid chromatography equipped with a diode array detector, an online enrichment and analysis method for eight polycyclic aromatic hydrocarbons was established under the optimum conditions. A good enrichment factor (52–814), good linearity (0.10–15 and 0.20–15 μg/L), low limits of detection (0.03–0.05 μg/L), and low limits of quantitation (0.10–0.20 μg/L) were achieved using a sample volume of 50 mL. Analysis method was applied to the real samples including the groundwater and wastewater from a chemical industry park, some target analytes were detected and the relative recoveries were in the range of 80.4–116.8%.  相似文献   

8.
A mesoporous silica was functionalized by carbon nanotubes to enhance the extraction performance. The mesoporous material was coated on stainless steel wires, and three wires were inserted inside of a polyetheretherketone tube for in‐tube solid‐phase microextraction. The tube was coupled to high‐performance liquid chromatography with diode array detection to obtain online analytical system, then its extraction performance was evaluated using eight polycyclic aromatic hydrocarbons as the targets. In order to good sensitivity and accuracy, four conditions were optimized such as sampling volume, sampling rate, methanol content in the sample, and desorption time. Under the optimum conditions, an online analytical method was established and exhibited low limits of detection from 0.005 to 0.050 µg/L, wide linear range of 0.016‐20.00 µg/L with acceptable correlation coefficients in 0.9921‐0.9999, as well as large enrichment factors in the range of 311‐2412. The method was successfully applied to determine trace polycyclic aromatic hydrocarbons in some real water samples including, two kinds of bottled water, tap water, and river water, a few polycyclic aromatic hydrocarbons were detected but none quantified in these samples.  相似文献   

9.
Although an efficient and stable fiber coating is essential for the development of solid‐phase microextraction technique, it remains a challenging prospect. Herein, an inorganic nanocomposite material Ag2S@ZnS was prepared and used as a coating for fibers to detect polycyclic aromatic hydrocarbons in water samples in combination with a GC with flame ionization detector. Compared with a single ZnS material, the Ag2S@ZnS composite shows many uneven nano‐protrusions on the surface of the microspheres. In conjunction with the relatively scattered microstructure of the coating and the effective anion‐π interaction formed between ZnS and the hydrocarbons, it has a large specific surface area, fast diffusion of the target molecule on its surface, and appropriate adsorption of the target molecules; therefore, it exhibits good extraction efficiency for the hydrocarbons. Under optimal conditions, the proposed analytical method exhibits superior performance with good linearity (0.01–500 µg/L) and low limits of detection (0.001–0.200 µg/L). Combined with high thermal, chemical, and mechanical stability, the service life of the coating was improved and could be used 200 times without a significant reduction in the extraction performance, and at least 2000 extraction–desorption cycles can be achieved. Satisfactory results were also obtained for the real samples.  相似文献   

10.
A novel, low‐cost and effective in‐needle solid‐phase microextraction device was developed for the enrichment of trace polycyclic aromatic hydrocarbons in water samples. The in‐needle solid‐phase microextraction device could be easily assembled by inserting hydrofluoric acid‐etched wires, which were used as adsorbent, into a 22‐gauge needle tube within spring supporters. Compared with the commercial solid‐phase microextraction fiber, the developed device has higher efficiency for the extraction of polycyclic aromatic hydrocarbons with four to six rings from water samples using the optimized extraction conditions. With gas chromatography equipped with a flame ionization detector, the limits of detection for the polycyclic aromatic hydrocarbons with four to six rings ranged from 0.0020 to 0.0067 ng/mL. The relative standard deviations for one needle and needle‐to‐needle extractions were in the range of 5.2–9.9% (n = 5) and 3.4–12.3% (n = 5), respectively. The spiked recoveries of the polycyclic aromatic hydrocarbons in tap water samples ranged from 73.2 to 95.4%. This in‐needle solid‐phase microextraction device could be a good field sampler because of the low sample loss over a long storage time.  相似文献   

11.
A solid‐phase microextraction coupled with gas chromatography and mass spectrometry method has been developed for the determination of ten nitrated polycyclic aromatic hydrocarbons in water samples. Five different kinds of commerical fibers were used to compare the extraction efficiency, including 65 μm polydimethylsiloxane/divinylbenzene, 100 μm polydimethylsiloxane, 30 μm polydimethylsiloxane, 7 μm polydimethylsiloxane, and 85 μm polyacrylate fibers. Five factors were also selected to optimize conditions, including extraction temperature, time, stirring speed, salt concentration, and headspace volume. Taguchi design was applied to design the experiments and obtain the best parameters. The results show that 65 μm polydimethylsiloxane/divinylbenzene fiber directly immersed into aqueous solution for 35 min at 55°C with a constant stirring rate of 1150 rpm were the optimal conditions. Under these conditions, the limits of quantification were 0.007–0.063 μg/L, and the relative standard deviation based on six replicates ranged from 2.8 to 9.5%. The spiked recoveries ranged from 69.1 to 110.1%. Intra‐ and inter day relative standard deviations at three concentration levels were less than 12%, and the recoveries were 66.4–111.5%. The proposed method is reliable for analyzing nitrated polycyclic aromatic hydrocarbons in different water samples.  相似文献   

12.
Polydopamine was coated onto cotton fibers as the adsorbent to improve the extraction efficiency. Polydopamine‐coated cotton fibers were placed into a polyetheretherketone tube for in‐tube solid‐phase microextraction. To develop an online analysis system, the extraction tube was connected with high‐performance liquid chromatography. The tube was evaluated with five estrogenic analytes, and the extraction and desorption conditions were optimized to get high extraction efficiency. Under the optimum conditions, the enrichment factors of five analytes were 143–1745. An online analysis method was established, it had large linear ranges (0.10–40 and 0.16–40 μg/L), low limits of detection (0.03, 0.05 μg/L) and satisfactory repeatability (≤3.2%). The analysis method was applied to detect targets in the real samples like as hot water in new plastic cup and tap water. The relative recoveries spiked at 1 and 5 μg/L in these samples were investigated and the results were in the range of 83.7–109%.  相似文献   

13.
Silicon carbide has excellent properties, such as corrosion resistance, high strength, oxidation resistance, high temperature, and so on. Based on these properties, silicon carbide was coated on stainless‐steel wire and used as a solid‐phase microextraction coating, and polycyclic aromatic hydrocarbons were employed as model analytes. Using gas chromatography, some important factors that affect the extraction efficiency were optimized one by one, and an analytical method was established. The analytical method showed wide linear ranges (0.1–30, 0.03–30, and 0.01–30 μg/L) with satisfactory correlation coefficients (0.9922–0.9966) and low detection limits (0.003–0.03 μg/L). To investigate the practical application of the method, rainwater and cigarette ash aqueous solution were collected as real samples for extraction and detection. The results indicate that silicon carbide has excellent application in the field of solid‐phase microextraction.  相似文献   

14.
We attempt to introduce animal bone waste as a coating material with an organic−inorganic structure for the fabrication of a coiled solid‐phase microextraction fiber for the first time. The coiled fiber was simply prepared with the use of copper wire and coated with bone waste suspension through the dip‐coating method. The bone waste coating was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and X‐ray diffraction analysis. It was applied as new type of solid‐phase microextraction fiber for preconcentration of polycyclic aromatic hydrocarbons before determination by high‐performance liquid chromatography with UV detection. A wide linear range 0.01–99.0 μg/L and limits of detection in the range 3.0–11.1 ng/L were obtained at optimized conditions. The bone waste coated coiled solid‐phase microextraction fiber has promise in sample preparation techniques because it is cost effective, available, stable in aqueous and organic solutions, environmentally friendly, and easy to fabricate and operate.  相似文献   

15.
Stainless‐steel wires coated with mesoporous titanium oxide were placed into a polyether ether ketone tube for in‐tube solid‐phase microextraction, and the coating sorbent was characterized by X‐ray diffraction and scanning electron microscopy. It was combined with high‐performance liquid chromatography to build an online system. Using eight polycyclic aromatic hydrocarbons as the analytes, some conditions including sample flow rate, sample volume, organic solvent content, and desorption time were investigated. Under optimum conditions, an online analysis method was established and provided good linearity (0.03–30 μg/L), low detection limits (0.01–0.10 μg/L), and high enrichment factors (77.6–678). The method was applied to determine target analytes in river water and water sample of coal ash, and the recoveries are in the range of 80.6–106.6 and 80.9–103.5%, respectively. Compared with estrogens and plasticizers, extraction coating shows better extraction efficiency for polycyclic aromatic hydrocarbons.  相似文献   

16.
Basalt fibers were functionalized with gold nanoparticles and characterized by scanning electron microscopy and energy‐dispersive X‐ray spectroscopy. An in‐tube solid‐phase microextraction device was developed by packing the functionalized basalt fibers in a polyether ether ketone tube. The device was connected into high performance liquid chromatography equipment with a diode array detector to build online enrichment and analysis system. Eight polycyclic aromatic hydrocarbons were used as model analytes, important factors including sampling rate, sampling volume, organic solvent content in sample, and desorption time were investigated. Linear range (0.01–20 μg/L), detection limits (0.003–0.015 μg/L), and enrichment factors (130–1628) were given by the online analysis method. Relative standard deviations (= 5) of extraction repeatability on one tube and tube‐to‐tube repeatability were less than 5.2 and 14.7%, respectively. The analysis method was applied to detect polycyclic aromatic hydrocarbons in environmental water samples, and relative recoveries ranged from 87 to 128%.  相似文献   

17.
A method for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil samples using ultrasonic‐assisted extraction with internal surrogates combined with solid‐phase microextraction and GC‐MS has been developed. Five kinds of commercial solid‐phase microextraction fibers, 100 μm PDMS, 30 μm PDMS, 65 μm PDMS/DVB, 50 μm DVB/CAR/PDMS and 85 μm PA, were compared to choose the optimal SPME fiber for extraction of PAHs. One hundred micrometers of PDMS fiber was found to be more suitable for the determination of PAHs due to its wider linear range, better repeatability, lower detection and more satisfactory efficacy than the other fibers. Under the recommended conditions, 100 μm PDMS fiber could provide low nanogram level detection limits with correlation coefficient greater than 0.98. The method was also applied to determine PAHs in a spiked soil sample, obtaining recoveries higher than 79.3%. A field study with naturally contaminated samples from local contaminated sites was carried out. The proposed method was found to be a reliable, inexpensive and simple preparation method for quantitative determination of 16 PAHs in soil samples.  相似文献   

18.
In this study, a novel technique is proposed for preparation of an efficient and unbreakable metal‐wire‐supported solid‐phase microextraction fiber. A sol–gel film was deposited on electrophoretically deposited carbon nanotubes on a stainless‐steel wire. The applicability of the fiber was evaluated through the extraction of some aromatic pollutants as model compounds from the headspace of aqueous samples in combination with gas chromatography and mass spectrometry. The parameters affecting the structure and extraction efficiency of the fiber (including the type of solvent, time, and potential for electrophoretic deposition) and the parameters affecting the extraction efficiency (such as coating type, salt content, extraction temperature, and time) were investigated. The results showed that the film thickness will be increased by increasing the potential and time duration. Finally, the characterization of the deposited film was accomplished by scanning electron microscopy and thermogravimetric analysis. After the optimization of the extraction parameters, the limit of detection of less than 20 pg/mL was achieved, and the calibration curves were all linear (r 2 ≥ 0.9737), in the range from 50 to 500 pg/mL. The solid‐phase microextraction fiber has a high mechanical strength; good stability and long service life, making it potentially applicable in the extraction of trace polycyclic aromatic hydrocarbons from aqueous samples.  相似文献   

19.
A novel design of hollow‐fiber liquid‐phase microextraction containing multiwalled carbon nanotubes as a solid sorbent, which is immobilized in the pore and lumen of hollow fiber by the sol–gel technique, was developed for the pre‐concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples. The proposed method utilized both solid‐ and liquid‐phase microextraction media. Parameters that affect the extraction of polycyclic aromatic hydrocarbons were optimized in two successive steps as follows. Firstly, a methodology based on a quarter factorial design was used to choose the significant variables. Then, these significant factors were optimized utilizing central composite design. Under the optimized condition (extraction time = 25 min, amount of multiwalled carbon nanotubes = 78 mg, sample volume = 8 mL, and desorption time = 5 min), the calibration curves showed high linearity (R 2 = 0.99) in the range of 0.01–500 ng/mL and the limits of detection were in the range of 0.007–1.47 ng/mL. The obtained extraction recoveries for 10 ng/mL of polycyclic aromatic hydrocarbons standard solution were in the range of 85–92%. Replicating the experiment under these conditions five times gave relative standard deviations lower than 6%. Finally, the method was successfully applied for pre‐concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples.  相似文献   

20.
This article introduces a simple, rapid, and reliable solid‐phase microextraction (SPME) method coupled with GC‐MS for the quantitative determination of 16 polycyclic aromatic hydrocarbons in water. In this study, the Taguchi experimental design was used to optimize extraction conditions of polycyclic aromatic hydrocarbons using SPME method to obtain highly enriched analytes. Consequently, quantitative determination of polycyclic aromatic hydrocarbons in water was achieved by GC‐MS technique. The selected parameters affecting enrichment of polycyclic aromatic hydrocarbons were sample extraction time, stirring speed, temperature, ionic strength, and pH. The study revealed that optimal operating conditions were found to be 90‐min extraction time, 1400 rpm stirring speed, and 60°C sample temperature. The effect of ionic strength and pH were shown to be insignificant. Optimized conditions were also reevaluated by placing the 16 polycyclic aromatic hydrocarbons into several subgroups based on their molecular weight. The extraction efficiency of polycyclic aromatic hydrocarbons with low molecular weight was shown to be a function of only the extracting temperature. Satisfactory results were obtained for linearity (0.983–0.999), detection limits (2.67–18.02 ng/L), accuracy (71.2–99.3%), and precision (4.3–13.5%). The optimum conditions reported by other design approaches were evaluated and generalized optimum conditions were suggested.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号