1.
Chemical speciation (extraction of elemental information and identification of molecular environment for an analyte in a complex sample) has been a long sought after goal for analytical chemists. Recently, because of successful developments in more sensitive element-specific detectors and gentle separation schemes, which preserve the true chemical information in a real sample, routine speciation experiments are becoming a common occurrence in the scientific literature. For many reasons, the combination of capillary electrophoresis (for separation of different chemical species) with inductively coupled plasma mass spectrometry (for element and isotope specific detection) has emerged as the method of choice for these analyses. In this article the basic principles of capillary electrophoresis inductively coupled plasma mass spectrometry are discussed. Design consideration for instrument interface, anticipated difficulties with speciation experiments and applications for specific matrices and analytes are also presented in this article.  相似文献   

2.
Species-specific (SS) isotope dilution analysis with gel electrophoresis (GE)-laser ablation (LA)-ICP-MS is a promising technique for the quantification of particular metal-binding proteins in biological samples. However, unavailable isotopically enriched spike and metal losses in GE separation are main limitations for SS-isotope dilution PAGE-LA-ICP-MS. In this study, we report for the first time the absolute quantification of transferrin (Tf) and albumin (Alb) in human serum by non-denaturing (native) GE combined with species-unspecific isotope dilution mass spectrometry (IDMS). In order to achieve a homogeneous distribution of both protein and isotope-enriched spike (simulated isotope equilibration), immersing the protein strips with 34S spike solution after gel electrophoresis was demonstrated to be an effective way of spike addition. Furthermore, effects of immersion time and 34S spike concentration were investigated to obtain optimal conditions of the post-electrophoresis isotope dilution method. The relative mass of spike and ablated sample (msp/msam) in IDMS equation was calculated by standard Tf and Alb proteins, which could be applied to the quantification of Tf and Alb in ERM-DA470k/IFCC for method confirmation. The results were in agreement with the certified value with good precision and small uncertainty (1.5–3%). In this method, species-specific spike protein is not necessary and the integrity of the heteroatom-protein could be maintained in sample preparation process. Moreover, the application of species-unspecific isotope dilution GE-LA-ICP-MS has the potential to offer reliable, direct and simultaneous quantification of proteins after conventional 1D and 2D gel electrophoretic separations.  相似文献   

3.
We report a simple and highly sensitive method for the simultaneous detection of trace zinc dimethyldithiocarbamate and zinc ethylenebisdithiocarbamate by capillary electrophoresis with inductively coupled plasma mass spectrometry. Zinc dimethyldithiocarbamate and zinc ethylenebisdithiocarbamate were chelated with trans‐1,2‐diaminocyclohexane‐N,N,N′,N′‐tetraacetic acid to form a macromolecule complex. Then, these two compounds were separated by α‐cyclodextrin‐modified capillary electrophoresis within 12 min at a separation voltage of 15 kV and measured by inductively coupled plasma mass spectrometry. The developed method is sensitive with detection limit of 1.9 and 3.0 ng Zn/mL for zinc dimethyldithiocarbamate and zinc ethylenebisdithiocarbamate, respectively. By means of ultrasound‐assisted extraction methods, zinc dimethyldithiocarbamate and zinc ethylenebisdithiocarbamate spiked into cabbage leaves were successfully extracted and determined with a relative standard deviation (= 5) ≤ 6% and a recovery of 95–107%.  相似文献   

4.
This paper describes a simple procedure for the direct analysis and determination of multiple elements in dried blood samples on a filter membrane using laser ablation coupled with inductively coupled plasma mass spectrometry (LA-ICP-MS). With this technique, we simultaneously quantified 13 elements in whole blood: Be, Mn, Co, Ni, Tl, Bi, Sb, Pb, Cu, Zn, Ba, Mg, and Cd. The measured accuracies was in agreement with the Seronorm CRM certified values, except for Mn, Zn, Ba and Cd, which presented absolute differences higher than the expanded uncertainty for these elements. The within-run precision was less than 5.7% (relative standard deviation, RSD), except for the analyses of Be, and Mn (8.6% and 11.1%, respectively). The reproducibility (between-run precision) was calculated in terms of the RSD obtained for 12 analyses (i.e., four replicates of each sample in three analytical runs). Apart from Be, Mn, and Zn, the reproducibilities of all the elements listed above ranged between 4.0% and 8.5%. In contrast, for Cd, the concentration obtained was significantly different from the certified value; analyses of this element exhibited low reproducibility. Applying the matrix-matched calibration method, the accuracy for Cd measured was in agreement with both SRM966 and BCR 635; thus, matrix-matched calibration is a practical means of overcoming matrix-enhancement effects for the quantification of Cd. Sample throughput (ca. 5 min per sample) made it possible to rapidly screen a larger number of samples relative to other techniques that require time-consuming sample preparation steps (e.g., removal of a portion of the solid sample or digestion).  相似文献   

5.
Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) have been applied as the most important inorganic mass spectrometric techniques having multielemental capability for the characterization of solid samples in materials science. ICP-MS is used for the sensitive determination of trace and ultratrace elements in digested solutions of solid samples or of process chemicals (ultrapure water, acids and organic solutions) for the semiconductor industry with detection limits down to sub-picogram per liter levels. Whereas ICP-MS on solid samples (e.g. high-purity ceramics) sometimes requires time-consuming sample preparation for its application in materials science, and the risk of contamination is a serious drawback, a fast, direct determination of trace elements in solid materials without any sample preparation by LA-ICP-MS is possible. The detection limits for the direct analysis of solid samples by LA-ICP-MS have been determined for many elements down to the nanogram per gram range. A deterioration of detection limits was observed for elements where interferences with polyatomic ions occur. The inherent interference problem can often be solved by applying a double-focusing sector field mass spectrometer at higher mass resolution or by collision-induced reactions of polyatomic ions with a collision gas using an ICP-MS fitted with collision cell. The main problem of LA-ICP-MS is quantification if no suitable standard reference materials with a similar matrix composition are available. The calibration problem in LA-ICP-MS can be solved using on-line solution-based calibration, and different procedures, such as external calibration and standard addition, have been discussed with respect to their application in materials science. The application of isotope dilution in solution-based calibration for trace metal determination in small amounts of noble metals has been developed as a new calibration strategy. This review discusses new analytical developments and possible applications of ICP-MS and LA-ICP-MS for the quantitative determination of trace elements and in surface analysis for materials science.  相似文献   

6.
Hui-Fang Hsieh 《Talanta》2009,79(2):183-240
This work describes a simple procedure for blood lead level determination. The proposed method requires little sample pretreatment and subsequent direct analysis of a dried blood spot on a filter membrane using laser ablation coupled with inductively coupled plasma mass spectrometry (LA-ICP-MS). In general, LA-ICP-MS studies are somewhat limited by the lack of matrix-matched standards for calibration purposes. Here we describe aqueous standard calibration and matrix-matched calibration methods. This method was validated by analysis of the reference materials. With the matrix-matched calibration method, the recovery ranged from 97.8% to 112.8%, while the aqueous standard calibration method ranged 90.4% to 122.4%. The lower detection limit was estimated as 0.1 ng mL−1. The determination precision, expressed as the relative standard deviation (RSD), was not worse than 10% for all results. A sample throughput of approximately 5 min per sample made it possible to rapidly screen a large number of samples.  相似文献   

7.
In this work we present a novel approach for in vitro studies of cisplatin interactions with 8-mer oligonucleotides. The approach is based on the recently developed coupling of continuous elution gel electrophoresis (GE) to an inductively coupled plasma-sector field mass spectrometer (ICP-SFMS) with the aim of monitoring the interaction process between this cytostatic drug and the nucleotides. In contrast to existing methods, the electrophoretic separation conditions used here allow both the determination of the reaction kinetics in more detail as well as the observation of dominant intermediates. Two different nucleotides sequences have been investigated for comparison purposes, one containing two adjacent guanines (5'-TCCGGTCC-3') and one with a combination of thymine and guanine (5'-TCCTGTCC-3'), respectively. In order to gain further structural information, MALDI-TOF MS measurements have been performed after fraction collection. This allows for identification of the intermediates and the final products and confirms the stepwise coordination of cisplatin via monoadduct to bisadduct formation. Furthermore, the ICP-MS results were quantitatively evaluated in order to calculate the kinetics of the entire process.  相似文献   

8.
We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6–21% for pressed pellets and 3–21% for fused solids were obtained from n = 3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches.  相似文献   

9.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for quantitative imaging of toxic and essential elements in thin sections (thickness of 30 or 40 μm) of tobacco plant tissues. Two-dimensional images of Mg, Fe, Mn, Zn, Cu, Cd, Rh, Pt and Pb in leaves, shoots and roots of tobacco were produced. Sections of the plant tissues (fixed onto glass slides) were scanned by a focused beam of a Nd:YAG laser in a laser ablation chamber. The ablated material was transported with argon as carrier gas to the ICP ion source at a quadrupole ICP-MS instrument. Ion intensities of the investigated elements were measured together with 13C+, 33S+ and 34S+ within the entire plant tissue section. Matrix matching standards (prepared using powder of dried tobacco leaves) were used to constitute calibration curves, whereas the regression coefficient of the attained calibration curves was typically 0.99. The variability of LA-ICP-MS process, sample heterogeneity and water content in the sample were corrected by using 13C+ as internal standard. Quantitative imaging of the selected elements revealed their inhomogeneous distribution in leaves, shoots and roots.  相似文献   

10.
We have analyzed phosphorus in an enzymatically digested DNA molecule using capillary electrophoresis (CE) hyphenated with inductively coupled plasma mass spectrometry (ICP-MS). The DNA concentration was quantified by the phosphorus value obtained in the CE-ICP-MS analysis. The CE-ICP-MS measurement, for which the interface device AIF-01 equipped three layered nebulizer was adopted, was achieved with limited μL/min nebulizing without loss of sample in the vaporizing chamber. The samples of nucleotides and free phosphate were separated well in the CE-ICP-MS measurement, and the calibration curve (0.1-10μg/mL) of the phosphorus showed a linear (R(2)=0.999) increase in intensity. After digestion of the 100-bp double-strand DNA sample to deoxyribonucleotide-5'-monophosphates (dNMPs) by phosphodiesterase-I, phosphorus was detected by CE-ICP-MS without further purification steps. In this study, we applied two calculation schemes of DNA analysis using a dNMP concentration obtained from CE-ICP-MS. Comparative CE-ICP-MS analysis with DNA digested to dNMPs showed that the assay gave an equal value obtained from the total DNA quantification using fluorescence detection. The detection limits of the DNA sample obtained from these species and phosphorus in nucleotides using CE-ICP-MS were 3.1-26ng/mL. These LOD values were equal to the conventional fluorescence determination of DNA.  相似文献   

11.
On‐line coupling of LC and ICP‐MS has been used for fractionation and detection of species of Cu, Fe, I, Se and Zn in human serum. It has been shown that anion exchange chromatography provided better separation capability (both intra‐ and inter‐element) than size‐exclusion chromatography. The mobile phases for ion exchange chromatography consisted of Tris–HNO3 buffer and ammonium salt (nitrate, acetate or formate). Formate was found to be the best mobile phase counter ion, enabling good chromatographic separation, and is acceptable for mass spectrometry too. The quantitative evaluation of element concentrations adhering to individual fractions was performed by the peak area normalization method. The repeatability of results ranged from 3 to 15% (depending on the element concentration level) and represented the main part of the result uncertainty. The accuracy of Cu and Zn fraction determinations was confirmed by comparison with the isotope dilution technique. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

12.
Yang G  Xu X  Wang W  Xu L  Chen G  Fu F 《Electrophoresis》2008,29(13):2862-2868
In this work, a novel and high-efficiency interface has been developed in coupling CE with inductively coupled plasma MS (ICPMS). The interface completely avoids laminar flow in CE capillary caused by the suction of nebulizer, and can be easily and stably operated at room temperature with high analyte transport efficiency to ICPMS. The new interface has a liquid dead volume smaller than 5 nL, which was much smaller than those (65-2500 microL) reported previously for other interfaces. All above features led to a higher sensitivity and a better electrophoretic resolution for CE-ICPMS coupled with this new interface. With the help of this new interface, we have successfully separated and determined five species of arsenic, As(III), As(V), monomethylarsonic acid, dimethylarsinic acid and p-aminophenylarsonic acid using CE-ICPMS within 11 min with a detection limit of 0.046-0.075 ng/mL and an RSD of 2-6% (n=6).  相似文献   

13.
Capillary electrophoresis dynamic reaction cell™ inductively coupled plasma mass spectrometry (CE-DRC-ICP-MS) for the determination of sulfur-containing amino acids is described. The sulfur-containing amino acids studied include l-cysteine, l-cystine, dl-homocystine and l-methionine. The species studied were well separated using a 70 cm length×75 μm i.d. fused silica capillary while the applied voltage was set at +22 kV and a 10 mmol l−1 disodium tetraborate buffer (pH 9.8) containing 0.1 mmol l−1 EDTA and 0.5 mmol l−1 Triton X-100 was used as the electrophoretic buffer. The sulfur-selective electropherogram was determined at m/z 48 as by using its reaction with O2 in the reaction cell. The method avoided the effect of polyatomic isobaric interferences at m/z 32 caused by and on by detecting as the oxide ion at m/z 48, which is less interfered. The detection limit of various species studied was in the range of 0.047-0.058 μg S ml−1, which corresponded to the absolute detection limit of 1.3-1.6 pg S based on the injection volume of 27 nl. We determined the concentrations of selected sulfur-containing amino acids in urine and nutritive complement samples. The recovery was in the range of 92-128% for various species.  相似文献   

14.
Laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS) is well established as a sensitive trace and ultratrace analytical technique with multielement capability for bioimaging of metals and studying metallomics in biological and medical tissue. Metals and metalloproteins play a key role in the metabolism and formation of metal‐containing deposits in the brain but also in the liver. In various diseases, analysis of metals and metalloproteins is essential for understanding the underlying cellular processes. LA–ICP–MS imaging (LA–ICP–MSI) combined with other complementary imaging techniques is a sophisticated tool for investigating the regional and cellular distribution of metals and related metal‐containing biomolecules. On the basis of successful routine techniques for the elemental bioimaging of cryosections by LA–ICP–MSI with a spatial resolution between 200 and ~10 µm, the further development used online laser microdissection ICP–MSI to study the metal distribution in small biological sample sections (at the cellular level from 10 µm to the submicrometer range). The use of mass spectrometric imaging of metals and also nonmetals is demonstrated on a series of biological specimens. This article discusses the state of the art of bioimaging of metals in thin biological tissue sections by LA–ICP–MSI with spatial resolution at the micrometer scale, future developments and prospects for quantitative imaging techniques of metals in the nanometer range. In addition, combining quantitative elemental imaging by LA/laser microdissection–ICP–MSI with biomolecular imaging by matrix‐assisted laser desorption/ionization–MSI will be challenging for future life science research. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
Nanoliter high‐performance liquid chromatography shows low consumption of solvents and samples, offering one of the best choices for arsenic speciation in precious samples in combination with inuctively coupled plasma mass spectrometry. A systematic investigation on coupling nanoliter high‐performance liquid chromatography to inductively coupled plasma mass spectrometry from instrument design to injected sample volume and mobile phase was performed in this study. Nanoflow mobile phase was delivered by flow splitting using a conventional high‐pressure pump with reuse of mobile phase waste. Dead volume was minimized to 60 nL for the sheathless interface based on the previously developed nanonebulizer. Capillary columns for nanoliter high‐performance liquid chromatography were found to be sensitive to sample loading volume. An apparent difference was also found between the mobile phases for nanoliter and conventional high‐performance liquid chromatography. Baseline separation of arsenite, arsenate, monomethylarsenic, and dimethylarsenic was achieved within 11 min on a 15 cm C18 capillary column and within 12 min on a 25 cm strong anion exchange column. Detection limits of 0.9–1.8 μg/L were obtained with precisions variable in the range of 1.6–4.2%. A good agreement between determined and certified values of a certified reference material of human urine (GBW 09115) validated its accuracy along with good recoveries (87–102%).  相似文献   

16.
The multianalyte immunoassay approach is currently attracting increasing attention due to its high sample throughput, short assay time, low sample consumption and reduced overall cost per assay. This paper reviews progress in the field of multianalyte immunoassays using inductively coupled plasma mass spectrometry, as well as applications of this approach in different fields. Examples related to the combination of protein microarray technology with the multitag approach of the immunoassay ICP-MS method and to the use of ICP-MS in the field of imaging are described. A novel strategy that involves tagging antibodies for ICP-MS detection in sensitive multitag bioassays is also presented. Finally, the outlook for this promising technique is discussed.  相似文献   

17.
A laser ablation setup including outer chamber, sample tube, sample holder and transport tubing was modelled and optimized using advanced computational fluid dynamics techniques. The different components of the setup were coupled and the whole device was modelled at once. The mass transport efficiency and transit times of near infrared femtosecond (fs) laser generated brass aerosols in pure argon and helium–argon mixtures were calculated at experimentally optimized conditions and a transient signal was constructed. The use of helium or argon did not influence the mass transport efficiency, but the signal structure changed. The signal fine structure was retrieved and experimentally validated. Bimodal peak structures were observed that seemed to originate from turbulent effects in the tubing connecting a Y-connector and the injector.  相似文献   

18.
Coedo AG  Padilla I  Dorado MT 《Talanta》2005,67(1):136-143
Element determination in solid waste products from the steel industry usually involves the time-consuming step of preparing a solution of the solid. Laser ablation (LA) inductively coupled plasma mass spectrometry (ICP-MS) has been applied to the analysis of Cr, Ni, Cu, As, Cd and Sn, elements of importance from the point of view of their impact on the environment, in electric arc furnace flue dust (EAFD). A simple method of sample preparation as pressed pellets using a mixture of cellulose and paraffin as binder material was applied. Calibration standards were prepared spiking multielement solution standards to a 1:1 ZnO + Fe2O3 synthetic matrix. The wet powder was dried and mechanically homogenised. Quantitative analysis were based on external calibration using a set of matrix matched calibration standards with Rh as a internal standard. Results obtained using only one-point for calibration without matrix matched, needing less time for standardization and data processing, are also presented. Data are calculated for flue dust reference materials: CRM 876-1 (EAFD), AG-6203 (EAFD), AG-6201 (cupola dust) and AG-SX3705 (coke ashes), and for two representative electrical arc furnace flue dusts samples from Spanish steelmaking companies: MS-1 and MS-2. For the reference materials, an acceptable agreement with certificate values was achieved, and the results for the MS samples matched with those obtained from conventional nebulization solutions (CN). The analytical precision was found to be better than 7% R.S.D. both within a single pellet and between several pellets of the same sample for all the elements.  相似文献   

19.
A quadrupole inductively coupled plasma mass spectrometer was evaluated for use in the detection of phosphorus. The influences of nitric acid and methanol (simulating the composition of a sample solution after nitric acid digestion) on phosphorus determination were studied using two different measuring methods at different plasma conditions: detection of phosphorus ions at m/z 31 and detection of phosphorus oxide ions at m/z 47. The existence of polyatomic interferences at m/z 31 and 47 was explored. Nitric acid and methanol are shown to be the sources of polyatomic ions and therefore cause poorer detection limits. Better detection limits were achieved in such matrices when phosphorus was detected as 31P+. The presence of methanol improves the system sensitivity towards phosphorus sevenfold; however, this positive effect is hindered by the high background signal due to carbon-based polyatomic ions. For samples with an organic matrix an appropriate mineralization procedure should be applied (high excess of nitric acid and high temperature) to quantitatively oxidize organic compounds to carbon dioxide, which is easily removed from the sample, in order to achieve correct results.  相似文献   

20.
建立了测定煤矸石中微量锗和镓的电感耦合等离子体质谱法。煤矸石试样经高温灰化,用硝酸-氢氟酸-高氯酸-磷酸分解,以电感耦合等离子体质谱法测定其中的锗和镓。通过在线三通加入内标元素铑,消除非质谱干扰;通过选择干扰元素的异质同位素进行定量测定,采用数学公式在线校正,消除质谱干扰。与分光光度法进行比对,锗、镓测定结果的相对偏差为-0.63%~0.28%。克服了常规化学分析方法步骤繁琐、耗时长、工作量大的不足。该法测定结果的相对标准偏差小于3%(n=6),加标回收率为97.4%~102.5%。该方法具有检出限低、快速、简便、线性范围宽、多元素同时测定等优点,分析误差满足化学分析法的要求,可用于煤矸石中锗和镓的测定。  相似文献   