首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The mixed-mode separation of a selection of anionic and cationic pharmaceutically related compounds is studied using ion-exchange columns and eluents consisting of ionic salts (potassium hydroxide or methanesulfonic acid) and an organic modifier (methanol). All separations were performed using commercially available ion-exchange columns and an ion chromatography instrument modified to allow introduction of methanol into the eluent without introducing compatibility problems with the eluent generation system. Isocratic retention prediction was undertaken over the two-dimensional space defined by the concentration of the competing ion and the percentage of organic modifier in the eluent. Various empirical models describing the observed relationships between analyte retention and both the competing ion concentration and the percentage of methanol were evaluated, with the resultant model being capable of describing the separation, including peak width, over the entire experimental space based on six initial experiments. Average errors in retention time and peak width were less than 6% and 27%, respectively, for runs taken from both inside and outside of the experimental space. Separations performed under methanol gradient conditions (while holding the competing ion concentration constant) were also modelled. The observed effect on retention of varying the methanol composition differed between analytes with several analytes exhibiting increased retention with increased percentage methanol in the eluent. An empirical model was derived based on integration of the observed tR vs. %methanol plot for each analyte. A combination of the isocratic and gradient models allowed for the prediction of retention time using multi-step methanol gradient profiles with average errors in predicted retention times being less than 4% over 30 different 2- and 3-step gradient profiles for anions and less than 6% over 14 different 2- and 3-step gradient profiles for cations. A modified peak compression model was used to estimate peak widths under these conditions. This provided adequate width prediction with the average error between observed and predicted peak widths being less than 15% for 40 1-, 2- and 3-step gradients for anions and less than 13% over 14 1-, 2- and 3-step gradients for cations.  相似文献   

2.
Summary A new method for prediction of gas chromatographic retention times and peak half widths is based on the renewal theory. The only requirements are the heats of vaporization of the compounds to be separated and one calibration measurement. With this data, retention times and peak half widths can be predicted for isothermal as well as temperature-programmed gas chromatography. For the separation of non-polar substances on non-polar stationary phases the prediction error for retention times is approx. 1–2%. First simulations of polar molecules and polar stationary phases indicate that this method is also applicable in these cases but some extension will be required.  相似文献   

3.
Optimization of separations in gas chromatography is often a time-consuming task. However, computer simulations of chromatographic experiments may greatly reduce the time required. In this study, the finite element method was used to predict the retention times and peak widths of three analytes eluting from each of four columns during chromatographic separations with two temperature programs. The data acquired were displayed in predicted chromatograms that were then compared to experimentally acquired chromatograms. The differences between the predicted and measured retention times were typically less than 0.1%, although the experimental peak widths were typically 10% larger than expected from the idealized calculations. Input data for the retention and peak dispersion calculations were obtained from isothermal experiments, and converted to thermodynamic parameters.  相似文献   

4.
This is the third part of a three‐part series of papers. In Part I, we presented a method for determining the actual effective geometry of a reference column as well as the thermodynamic‐based parameters of a set of probe compounds in an in‐house mixture. Part II introduced an approach for estimating the actual effective geometry of a target column by collecting retention data of the same mixture of probe compounds on the target column and using their thermodynamic parameters, acquired on the reference column, as a bridge between both systems. Part III, presented here, demonstrates the retention time transfer and prediction from the reference column to the target column using experimental data for a separate mixture of compounds. To predict the retention time of a new compound, we first estimate its thermodynamic‐based parameters on the reference column (using geometric parameters determined previously). The compound's retention time on a second column (of previously determined geometry) is then predicted. The models and the associated optimization algorithms were tested using simulated and experimental data. The accuracy of predicted retention times shows that the proposed approach is simple, fast, and accurate for retention time transfer and prediction between gas chromatography columns.  相似文献   

5.
A method combining gas chromatography with quadrupole time‐of‐flight mass spectrometry has been developed for the simultaneous analysis of multiple pesticide residues in tobacco leaf. The retention index and high accurate masses of ions from the first‐stage and the second‐stage mass spectra of each pesticide were collected for qualitation and quantification. A total of 115 pesticides were evaluated. The extract from organic tobacco leaf was used as a model matrix. The limit of detection was <10 ng/mL, and the limit of quantification was in the range of 1–20 ng/mL for 95% of the tested pesticides. The correlation coefficients were >0.9900 for all tested pesticides. At three concentrations (10, 50, and 100 ng/mL), most compounds presented satisfactory recoveries ranging from 70 to 120% and good precision <20%. Finally, three tobacco leaf samples collected from a local market were analyzed. A total of three pesticides were found, including dimethachlon, triadimenol, and flumetralin. Each pesticide was confirmed by the presence of three ions at the expected retention index and mass. In conclusion, gas chromatography with quadrupole time‐of‐flight mass spectrometry appears to be one of the most efficient tools for the analysis of pesticide residues in tobacco leaf.  相似文献   

6.
Thermodynamic modeling of retention times in gas chromatography depends on the accurate estimation of thermodynamic parameters. Previous research has used manual injections of samples with coinjection of a dead time marker to obtain accurate measurements of the retention factor of analytes. Ideally this process would be automated. Herein an approach is presented by which thermodynamic parameters can be estimated both autonomously and accurately. This method also allows for a consistent estimation of thermodynamic parameters regardless of factors such as data system delays and the nature of the void time marker employed. Ignoring these factors can lead to significant errors in the prediction of retention times when using thermodynamic models.  相似文献   

7.
Implementation of a data reduction and visualization method for use with high-speed gas chromatography and time-of-flight mass spectrometry (GC-TOFMS) is reported. The method, called the “2D m/z cluster method” facilitates analyte detection, deconvolution, and identification, by accurately measuring peak widths and retention times using a fast TOFMS sampling frequency (500 Hz). Characteristics and requirements for high speed GC are taken into consideration: fast separations with narrow peak widths and high peak capacity, rapid data collection rate, and effective peak deconvolution. Transitioning from standard GC (10–60+ minute separations) to fast GC (1–10 min separations) required consideration of how to properly analyze the data. This report validates use of the 2D m/z cluster method with newly developed GC technology that produces ultra-fast separations (∼1 min) with narrow analyte peak widths. Low thermal mass gas chromatography (LTM-GC) operated at a heating rate of 250 °C/min coupled to a LECO Pegasus III TOFMS analyzed a 115 component test mixture in 120 s with peak widths-at-base, wb (4σ), of 350 ms (average) to produce a separation with a high peak capacity, nc ∼ 340 (at unit resolution Rs = 1). The 2D m/z cluster method is shown to separate overlapped analytes to a limiting Rs ∼ 0.03, so the effective peak capacity was increased nearly 30-fold to nc ∼10,000 in the 120 s separation. The method, when coupled with LTM-GC-TOFMS, is demonstrated to provide unambiguous peak rank (i.e. the number of analytes per overlapped peak in the total ion current (TIC)), by visualizing locations of pure and chromatographically overlapped m/z. Hence, peak deconvolution and identification using MCR-ALS (multivariate curve resolution – alternating least squares) is demonstrated.  相似文献   

8.
The retention behavior of components analyzed by chromatography varies with instrumental settings. Being able to predict how changes in these settings alter the elution pattern is useful, both with regards to component identification, as well as with regards to optimization of the chromatographic system. In this work, it is shown how experimental designs can be used for this purpose. Different experimental designs for response surface modeling of the separation of fatty acid methyl esters (FAME) as function of chromatographic conditions in GC have been evaluated. Full factorial, central composite, Doehlert and Box-Behnken designs were applied. A mixture of 38 FAMEs was separated on a polar cyanopropyl substituted polysilphenylene-siloxane phase capillary column. The temperature gradient, the start temperature of the gradient, and the carrier gas velocity were varied in the experiments. The modeled responses, as functions of chromatographic conditions, were retention time, retention indices, peak widths, separation efficiency and resolution between selected peak pairs. The designs that allowed inclusion of quadratic terms among the predictors performed significantly better than factorial design. Box-Behnken design provided the best results for prediction of retention, but the differences between the central composite, Doehlert and Box-Behnken designs were small. Retention indices could be modeled with much better accuracy than retention times. However, because the errors of predicted tR of closely eluting peaks were highly correlated, models of resolution (Rs) that were based on retention time had errors in the same range as corresponding models based on ECL.  相似文献   

9.
In gas chromatography (GC) reproducible retention times are in many cases highly favorable or in some cases even required. In one-dimensional GC, retention time shifts can be eliminated or minimized using a procedure called retention time locking (RTL). This procedure is based on adjusting the (constant) column head pressure. Unfortunately, this RTL procedure cannot be used in comprehensive two-dimensional gas chromatography (GC × GC) given the fact that peaks will shift in both dimensions. Adjusting the column head pressure in GC × GC will only minimize or eliminate the primary retention time shifts. In this paper, a fast and easy to perform, two-step retention time locking procedure for two-dimensional gas chromatography (2D-RTL) is proposed and its feasibility is demonstrated. This 2D-RTL procedure involves adjustment of the column head pressure or constant column flow, followed by the adjustment of the so-called effective secondary column length. The secondary column length is increased or decreased, simply by moving it stepwise through the modulator. It is demonstrated that retention time shifts in both the primary- and secondary-dimension, which may occur after e.g. replacing the column set, can be minimized to less than half peak base width. The proposed 2D-RTL procedure is used successfully for approximately 1 year in our laboratory.  相似文献   

10.
The present research is based on the concept of using a 10 m × 0.1 mm id column for cryogenic‐modulation fast comprehensive two‐dimensional gas chromatography with quadrupole mass spectrometry. Specifically, an 8.9 m × 0.1 mm id low‐polarity column was used as the first dimension, and a 1.1 m × 0.1 mm id medium‐polarity column was used as the second dimension. The main scope of the investigation was to develop a high peak‐capacity method, with an analysis time of approximately 10 min. Various aspects related to method optimization are discussed, as well as separation parameters such as peak capacity (in each dimension, and as a total value), first‐dimension sample capacity, peak widths, modulation ratio, sensitivity enhancement, and number of spectra per peak. The fast approach was evaluated in applications involving a mixture of cosmetic allergens and a sample of perfume. The approach proposed enables high‐resolution separations in a short time (across the C8–C23 alkane range), as well as a considerable reduction of the consumption of gases for modulation cooling and heating.  相似文献   

11.
The purpose of this work was to test the applicability of the current theory to predict the peak retention time and the peak width in the combined pH/organic modifier gradient reversed phase high performance liquid chromatography (RP HPLC). A series of 38 isocratic measurements have been conducted for a wide range of pH and methanol contents for ketoprofen (weak acid) and papaverine (weak base). It served to find the model describing dependence of retention factor and the height equivalent of a theoretical plate (HETP) on pH and organic modifier content. The information gathered in the isocratic mode was used to simulate retention times and peak widths for 30 various methanol gradients, 25 pH gradients, and 3 combined pH/methanol gradients. The simulations were compared with the experimental data. We also proposed a simplified version of this model that was parameterized based on 12 initial organic modifier gradients carried out for different pHs and for the 20 min and 60 min gradient development times. The full and the simplified model described the experimental data very well. In conclusion, the proposed modeling approach allowed predicting analyte retention times and peak width for various pH and organic modifier changes. Its simplified version required only 12 initial experiments and seems to be very promising in the optimization RP HPLC separations for complex samples and for conditions providing peak compression.  相似文献   

12.
We describe a liquid chromatography method development approach for the separation of intact proteins using hydrophobic interaction chromatography. First, protein retention was determined as function of the salt concentration by isocratic measurements and modeled using linear regression. The error between measured and predicted retention factors was studied while varying gradient time (between 15 and 120 min) and gradient starting conditions, and ranged between 2 and 15%. To reduce the time needed to develop optimized gradient methods for hydrophobic interaction chromatography separations, retention‐time estimations were also assessed based on two gradient scouting runs, resulting in significantly improved retention‐time predictions (average error < 2.5%) when varying gradient time. When starting the scouting gradient at lower salt concentrations (stronger eluent), retention time prediction became inaccurate in contrast to predictions based on isocratic runs. Application of three scouting runs and a nonlinear model, incorporating the effects of gradient duration and mobile‐phase composition at the start of the gradient, provides accurate results (improved fitting compared to the linear solvent‐strength model) with an average error of 1.0% and maximum deviation of –8.3%. Finally, gradient scouting runs and retention‐time modeling have been applied for the optimization of a critical‐pair protein isoform separation encountered in a biotechnological sample.  相似文献   

13.
The transfer of thermodynamic parameters governing retention of a molecule in gas chromatography from a reference column to a target column is a difficult problem. Successful transfer demands a mechanism whereby the column geometries of both columns can be determined with high accuracy. This is the second part in a series of three papers. In Part I of this work we introduced a new approach to determine the actual effective geometry of a reference column and thermodynamic‐based parameters of a suite of compounds on the column. Part II, presented here, illustrates the rapid estimation of the effective inner diameter (or length) and the effective phase ratio of a target column. The estimation model based on the principle of least squares; a fast Quasi‐Newton optimization algorithm was developed to provide adequate computational speed. The model and optimization algorithm were tested and validated using simulated and experimental data. This study, together with the work in Parts I and III, demonstrates a method that improves the transferability of thermodynamic models of gas chromatography retention between gas chromatography columns.  相似文献   

14.
The models proposed by many authors for the prediction of retention times and temperatures, peak widths, retention indices and separation numbers in programmed temperature and pressure gas chromatography by starting from preliminary measurements of the retention in isothermal and isobaric conditions are reviewed. Several articles showing the correlation between retention data and thermodynamic parameters and the determination of the optimum programming rate are reported. The columns of different polarity used for the experimental measurement and the main equations, mathematical models and calculation procedures are listed. An empirical approach was used in the early models, followed by the application of thermodynamic considerations, iterative calculation procedures and statistical methods, based on increased computing power now available. Multiple column arrangements, simultaneous temperature and pressure programming, applications of two-dimensional and fast chromatography are summarised.  相似文献   

15.
Fifteen liquid chromatographic experiments were investigated using a whole‐column detection (WCD) system and a conventional post‐column UV/Vis detector. The peak widths obtained from chromatograms were found dependent on the retention factor; the larger the retention factor was the greater the peak width. However, the on‐column spatial peak widths were dependent on the locations where they were measured in the column. The peak widths monitored at 17 cm from the column inlet were found essentially the same no matter what their retention factors were. In addition, a linear relationship was found between the chromatographic peak width and the reciprocal of the average linear rate of the solute migration. The peak widths on chromatograms did not reflect how they appeared in the column; instead, the widths were determined by the solute speed passing the detector.  相似文献   

16.
The preparative scale isolation of multiple components from an essential oil matrix is described using multidimensional gas chromatography (prep-MDGC) which allows their further characterisation by mass spectrometry and nuclear magnetic resonance (NMR) spectroscopy. Menthol, linalyl acetate, carvone and geraniol were isolated individually, and were also collected in various combinations. It was demonstrated to be possible to collect multiple selected components from numerous repeat injections of the sample, to permit increased mass recovery from an external cryotrap collection device. Peak retention times remained reproducible (<0.3 s) over the repeated injections and switching events. This methodology may be utilised to confirm peak identity or to produce unique mixed-component reference standards, for instance to allow their identification in other samples using GC/MS, or identify them in comprehensive two-dimensional gas chromatography (GC × GC) analysis.  相似文献   

17.
Comprehensive two‐dimensional gas chromatography is a technique that is becoming more widespread within the analytical community, especially in the separation of complex mixtures. Modulation in comprehensive two‐dimensional gas chromatography can be achieved by manipulating temperature or flow and offers many advantages such as increased separation power, but one underutilized advantage is increased detectability due to the reduction of peak width from the use of a modulator. A flow modulator was used to selectively target analytes for increased detectability with a standard flame ionization detector operated at 100 Hz, without the need for cryogens or advanced modulation software. By the collection of the entire peak volume followed by peak transfer rather than further separation, an increase of 12 times in peak height and detectability was realized for the analytes tested using an internal loop modulator configuration. An external loop flow modulator configuration allowed for more volatile analytes (with k < 5), and demonstrated an analyte detectability enhancement factor of at least 6. The collection loop size can be readily increased with an external loop configuration to accommodate for these naturally broader peaks. This novel flow modulated targeted signal enhancement approach was applied to industrially significant analyses like the analysis of methanol in a hydrocarbon streams. Methanol was detected at 7 ppb with a conventional flame ionization detector and without the need for pre‐concentration.  相似文献   

18.
For the direct determination of axial dispersion in size exclusion chromatography a simple method is presented which makes use of the measured and ideal peak widths. The peak width can be defined in two ways: either absolute as the difference of successive points of inflection or relative as the ratio of these points. If the absolute peak width is invariant for the number, molar mass and hyper distribution then this distribution can unambiguously be classified as Poissonian. The relative peak width for such distributions is strictly determined by the experimental parameters. It is demonstrated that axial dispersion only leads to an additive increase in the peak variances for peaks with a relative peak width smaller than 1.25. Thus, it is possible to determine directly the axial dispersion of an experimental size exclusion chromatography set‐up by the use of Poisson distributions prepared by quenched instationary polymerization techniques or any other technique leading to ideal Poisson distributions.  相似文献   

19.
A miniaturized, flexible, and low‐cost capillary ion chromatography system has been developed for anion analysis in water. The ion chromatography has an open platform, modular design, and allows for ease of modification. The assembled platform weighs ca. 0.6 kg and is 25 × 25 cm in size. Isocratic separation of common anions (F, Cl, NO2, Br, and NO3) could be achieved in under 15 min using sodium benzoate eluent at a flow rate of 3 μL/min, a packed capillary column (0.150 × 150 mm) containing Waters IC‐Pak 10 μm anion exchange resin, and light‐emitting diode based indirect UV detection. Several low UV light‐emitting diodes were assessed in terms of sensitivity, including a new 235 nm light‐emitting diode, however, the highest sensitivity was demonstrated using a 255 nm light‐emitting diode. Linear calibration ranges applicable to typical natural water analysis were obtained. For retention time and peak area repeatability, relative standard deviation values ranged from 0.60–0.95 and 1.95–3.53%, respectively. Several water samples were analysed and accuracy (recovery) was demonstrated through analysis of a prepared mixed anion standard. Relative errors of –0.36, –1.25, –0.80, and –0.76% were obtained for fluoride, chloride, nitrite, and nitrate, respectively.  相似文献   

20.
In this work a fast gas chromatography set‐up with on‐column injection was optimized and evaluated with a model mixture of C8–C28 n‐alkanes. Usual injection volumes when using narrow‐bore (e. g., 0.1 mm i.d.) analytical columns are ca. 0.1 μL. The presented configuration allows introduction of 10–30‐fold larger sample volumes without any distortion of peak shapes. In the set‐up a normal‐bore retention gap (1 m×0.32 mm i. d.) was coupled to a narrow‐bore (4.8 m×0.1 mm i. d.×0.4 μm film thickness) analytical column using a low dead volume column connector. The effects of the experimental conditions such as inlet pressure, sample volume, initial injection temperature, and oven temperature on a peak focusing are discussed. H‐u curves for helium and hydrogen are used to compare their suitability for high speed gas chromatography and to show the dependence of separation efficiency on the carrier gas velocity at high inlet pressures. In the fast gas chromatography system a baseline separation of C10–C28 n‐alkanes was achieved in less than 3 minutes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号