首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study describes the synthesis and application of a magnetic amino‐functionalized hollow silica‐titania microsphere as a new sorbent for magnetic dispersive micro‐solid phase extraction of selected pesticides in coffee bean samples. The sorbent was fully characterized by Fourier‐transform infrared spectroscopy, field emission scanning electron microscopy, transition electron microscopy, energy‐dispersive X‐ray spectroscopy, and vibrating sample magnetometry techniques. Significant extraction parameters affecting the proposed method, such as extraction time, sorbent amount, sample solution pH, salt amount, and desorption conditions (desorption solvent and time) were investigated and optimized. All the figures of merits were validated in coffee bean samples under the matrix‐matched calibration method. Linear dynamic ranges were 5–250 µg/kg with the determination coefficients (R2) > 0.9980. The limits of detection for the pesticides of chlorpyrifos, malathion, hexaconazole, and atrazine were 1.42, 1.43, 1.35, and 1.33 µg/kg, respectively. Finally, the method was successfully applied for the determination of the pesticides in green and roasted coffee bean samples, and the obtained recoveries were in the range of 74–113% for spiked samples. The prepared sorbent could be used for the magnetic dispersive micro‐solid phase extraction of pesticides in the plant‐derived food matrix.  相似文献   

2.
A simple and efficient multiresidue method using dispersive solid phase extraction and liquid chromatography coupled with tandem mass spectrometry was developed for the targeted analysis of indaziflam and its five metabolites (indaziflam‐diaminotriazine, indaziflam‐carboxylic acid, indaziflam‐triazine indanone, indaziflam‐hydroxyethyl, and indaziflam‐olefin) in pitaya samples (including roots, plants, flowers, peels, pulp, and whole fruit). The analytes were extracted with acetonitrile, and the extracts were purified using multiwalled carbon nanotubes. The method was validated using pitaya samples spiked at 0.5, 5, and 50 µg/kg, and the average recoveries varied from 61.1 to 103.7% with relative standard deviations lower than 12.7% (= 5). This method exhibited sufficient linearity within the concentration range of 0.1–100 µg/L. The limits of detection and quantification were in the ranges of 0.001–0.1 and 0.003–0.3 µg/kg, respectively. The method was successfully applied to analyze pitaya samples in Nanning, and no indaziflam or its metabolites were detected in the samples analyzed.  相似文献   

3.
A rapid, specific and sensitive ultra‐performance liquid chromatography tandem mass spectrometry method was developed for the determination of fenofibric acid in human plasma. The method involves simple, one‐step liquid–liquid extraction procedure coupled with an Acquity UPLCTM BEH C18 column (50 × 2.1 mm, i.d., 1.7 µm) with isocratic elution at a flow‐rate of 0.2 mL/min and mefenamic acid was used as the internal standard. The Quattro Premier XE mass spectrometry was operated under the multiple reaction‐monitoring mode using the electrospray ionization technique. Using 250 µL plasma, the methods were validated over the concentration rang 0.05–7.129 µg/mL, with a lower limit of quantification of 0.05 µg/mL. The intra‐ and inter‐day precision and accuracy were within 9.3%. The recovery was 66.7% and 52.6% for fenofibric acid, and mefenamic acid, respectively. Total run time was 1.8 min only for each sample, which makes it possible to analyze more than 350 samples per day. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
A sensitive method of CZE‐ultraviolet (UV) detection based on the on‐line preconcentration strategy of field‐amplified sample injection (FASI) was developed for the simultaneous determination of five kinds of chlorophenols (CPs) namely 4‐chlorophenol (4‐CP), 2‐chlorophenol (2‐CP), 2,4‐dichlorophenol (2,4‐DCP), 2,4,6‐trichlorophenol (2,4,6‐TCP), and 2,6‐dichlorophenol (2,6‐DCP) in water samples. Several parameters affecting CZE and FASI conditions were systematically investigated. Under the optimal conditions, sensitivity enhancement factors for 4‐CP, 2‐CP, 2,4‐DCP, 2,4,6‐TCP, and 2,6‐DCP were 9, 27, 35, 43, and 43 folds, respectively, compared with the direct CZE, and the baseline separation was achieved within 5 min. Then, the developed FASI‐CZE‐UV method was applied to tap and lake water samples for the five CPs determination. The LODs (S/N = 3) were 0.0018–0.019 µg/mL and 0.0089–0.029 µg/mL in tap water and lake water, respectively. The values of LOQs in tap water (0.006–0.0074 µg/mL) were much lower than the maximum permissible concentrations of 2,4,6‐TCP, 2,4‐DCP, and 2‐CP in drinking water stipulated by World Health Organization (WHO) namely 0.3, 0.04, and 0.01 µg/mL, respectively, and thereby the method was suitable to detect the CPs according to WHO guidelines. Furthermore, the method attained high recoveries in the range of 83.0–119.0% at three spiking levels of five CPs in the two types of water samples, with relative standard deviations of 0.37–8.58%. The developed method was proved to be a simple, sensitive, highly automated, and efficient alternative to CPs determination in real water samples.  相似文献   

5.
In this study, a simple and accurate sample preparation method based on dispersive solid‐phase extraction and dispersive liquid‐liquid microextraction has been developed for the determination of seven novel succinate dehydrogenase inhibitor fungicides (isopyrazam, fluopyram, pydiflumetofen, boscalid, penthiopyrad, fluxapyroxad, and thifluzamide) in watermelon. The watermelon samples were extracted with acetonitrile, cleaned up by dispersive solid‐phase extraction procedure using primary secondary amine, extracted and concentrated by the dispersive liquid‐liquid microextraction procedure with 1,1,2,2‐tetrachloroethane, and then analyzed by ultra high performance liquid chromatography with tandem mass spectrometry. The main experimental factors affecting the performance of dispersive solid‐phase extraction and dispersive liquid‐liquid microextraction procedure on extraction efficiency were investigated. The proposed method had a good linearity in the range of 0.1–100 µg/kg with correlation coefficients (r) of 0.9979–0.9999. The limit of quantification of seven fungicides was 0.1 µg/kg in the method. The fortified recoveries of seven succinate dehydrogenase inhibitor fungicides at three levels ranged from 72.0 to 111.6% with relative standard deviations of 3.4–14.1% (n = 5). The proposed method was successfully used for the rapid determination of seven succinate dehydrogenase inhibitor fungicides in watermelon.  相似文献   

6.
A novel plate‐like nano‐sorbent based on copper/cobalt/chromium layered double hydroxide was synthesized by a simple coprecipitation method. The synthesized nanoparticels were introduced into a stainless steel cartridge using a dry packing method. Then, the packed cartridge was introduced as a novel on‐line “packed in‐tube” configuration and followed by high performance liquid chromatography for the determination of trace amounts of ?9‐tetrahydrocannabinol from biological samples and cannabis leaves. The as‐prepared sorbent exhibited long lifetime, good chemical stability, and high anion‐exchange capacity. Several important factors affecting the extraction efficiency, such as extraction and desorption times, pH of the sample solution and flow rates of the sample and eluent solutions, were investigated and optimized. Under optimized conditions, this method showed good linearity for ?9‐tetrahydrocannabinol in the ranges of 0.09–500, 0.3–500, and 0.4–500 µg/L with coefficients of determination of 0.9999, 0.9991, and 0.9994 in water, serum and plasma samples, respectively. The inter‐ and intra‐assay precisions (n = 3) were respectively in the ranges of 1.8–4.6% and 1.9–4.0% at three concentration levels of 10, 50, and 100 µg/L. The limits of detection were also in the range of 0.02–0.1 µg/L.  相似文献   

7.
A novel effervescent tablet‐assisted demulsified dispersive liquid–liquid microextraction based on the solidification of floating organic droplet was developed to determine methadone prior to gas chromatography with flame ionization detection and gas chromatography with mass spectrometry. In this method, a tablet composed of citric acid, sodium carbonate, and 1‐undecanol was utilized. The resulting effervescent tablet generated carbon dioxide in situ to disperse 1‐undecanol in the sample. Thus, the dispersive and extraction processes were performed in one synchronous step. An aliquot of acetonitrile as the demulsifier solvent was used for the separation of two phases instead of centrifugation. Under optimal conditions, the developed method was linear up to 50 000 µg/L with correlation coefficients higher than 0.99. Moreover, limits of detection and limits of the quantification were in the range of 3‐10  and 7‐30 µg/L in water and biological samples, respectively. Intra‐ and interday precisions (n = 6) of the spiked methadone at a concentration level of 50 µg/L were over ranges of 5.1‐6.8% and 5.7‐7.1%, respectively. The preconcentration factors and recovery values were obtained in the range of 140‐145 and 98.1 to 101.6% in real samples, respectively.  相似文献   

8.
In this work, a simple, fast, sensitive, and environmentally friendly method was developed for preconcentration and quantitative measurement of bisphenol A in water samples using gas chromatography with mass spectrometry. The preconcentration approach, namely biosorption‐based dispersive liquid‐liquid microextraction with extractant removal by magnetic nanoparticles was performed based on the formation of microdroplet of rhamnolipid biosurfactant throughout the aqueous samples, which accelerates the mass transfer process between the extraction solvent and sample solution. The process is then followed by the application of magnetic nanoparticles for easy retrieval of the analyte‐containing extraction solvent. Several important variables were optimized comprehensively including type of disperser solvent and desorption solvent, rhamnolipid concentration, volume of disperser solvent, amount of magnetic nanoparticles, extraction time, desorption time, ionic strength, and sample pH. Under the optimized microextraction and gas chromatography with mass spectrometry conditions, the method demonstrated good linearity over the range of 0.5–500 µg/L with a coefficient of determination of R= 0.9904, low limit of detection (0.15 µg/L) and limit of quantification (0.50 µg/L) of bisphenol A, good analyte recoveries (84–120%) and acceptable relative standard deviation (1.8–14.9%, = 6). The proposed method was successfully applied to three environmental water samples, and bisphenol A was detected in all samples.  相似文献   

9.
A modified quick, easy, cheap, effective, rugged and safe method was established for simultaneous determination of atropine, anisodamine, and scopolamine in goji berries by using ultra‐high‐performance liquid chromatography with tandem mass spectrometry. The graphene/hexagonal boron nitride hybrids were prepared and first applied as a cleanup adsorbent. Compared to classical cleanup adsorbent (C18), the graphene/hexagonal boron nitride hybrids as adsorbent had better extraction efficiency for the detection of analytes. Under the optimal conditions, the proposed analytical method achieved satisfactory linearity (R> 0.995), and obtained desirable recoveries ranged from 77.4 to 94.0% with the relative standard deviation of 1.2–6.1% at the concentration levels of 3.2–13.4 µg/kg. The limits of quantitation of atropine, anisodamine, and scopolamine were, respectively, 3.2, 4.6, and 4.5 µg/kg with linearity ranged from 3.2 to 25.4 µg/kg. The modified quick, easy, cheap, effective, rugged, and safe sample preparation with ultra‐high‐performance liquid chromatography and tandem mass spectrometry method was successfully applied to evaluate the safety of goji berries collected from 30 plant areas in China, suggesting its applicability and suitability for the routine analysis of three tropane alkaloids in goji berries.  相似文献   

10.
Fipronil is an insecticide that is not approved in the European Union in food. In 2017, fipronil was involved in a European health alert due to its presence in fresh hen eggs because of an illicit use in poultry farms, so reliable methods are needed to determine fipronil and its main metabolites in these matrixes. In this work, we report the first approach to the study of fipronil and two metabolites, fipronil-sulfone and fipronil-sulfide by CE. MEKC mode was employed using a solution of 50 mM ammonium perfluorooctanoate pH 9.0 with 10% (v/v) methanol as background electrolyte. The proposed method was combined with a simple sample treatment based on salting-out assisted LLE (SALLE) using acetonitrile as extraction solvent and ammonium sulfate as salt. The SALLE–MEKC–UV method allowed the simultaneous quantification of fipronil and fipronil-sulfone. Validation parameters yielded satisfactory results, with precision, expressed as relative SD, below 14% and recoveries higher than 83%. Limits of detection were 90 µg/kg for fipronil and 150 µg/kg for fipronil-sulfone, so in terms of sensitivity further studies of sample treatments allowing extra preconcentration or the use of more sensitive detection, such as MS, would be needed.  相似文献   

11.
In this study, the new and efficient three‐dimensional network porous aromatic frameworks materials called Silica‐PAFs‐a, Florisil‐PAFs‐a, Silica‐PAFs‐b, and Florisil‐PAFs‐b were first synthesized. The properties of materials were analyzed by five characterization methods. The materials were used as adsorbents in pipette‐tip solid‐phase extraction for the effective determination of carbendazim and thiabendazole in spinach sample. Meanwhile, the obtained materials were tested by static adsorption and dynamic adsorption. The result showed that the specific surface area of materials greatly increased after introducing three‐dimensional network porous aromatic frameworks. Microstructural modification exposed a large number of amino reactive groups that made them have a better adsorption amount for the two targets. The calibration graphs of carbendazim and thiabendazole in methanol were linear over 0.10–300.0 µg/mL, and the limits of detection and quantification were 0.00546 and 0.0182 µg/mL, and 0.00741 and 0.0247µg/mL respectively. A reliable analytical method was developed for recognition targets in spinach sample by Silica‐PAFs‐b with satisfactory extraction recoveries (96.25 and 100.51%). The proposed method using the material was applied for trace analysis of the carbendazim and thiabendazole residue.  相似文献   

12.
The present work reported a novel hydrophilic and selective solid‐phase microextraction fiber by improved multiple co‐polymerization method immobilization of tetracycline molecularly imprinted polymer on a stainless steel wire and directly coupled with high‐performance liquid chromatography for sensitive determination of trace tetracyclines residues in animal derived foods. The developed molecularly imprinted polymer coated solid‐phase microextraction fibers were characterized through scanning electron microscopy, Fourier transfer infrared spectroscopy, thermogravimetric analysis, and adsorption experiments, the fiber with cross‐linked and porous structure was observed and high thermal and chemical stability. The maximum adsorption capacity of this fiber with good selectivity reached 2.35 µg/mg in aqueous matrices, and showed good repeatability (relative standard deviation ≤ 6.6%, n = 5) and satisfying reproducibility between fiber to fiber (relative standard deviation ≤ 7.8%, n = 5). Under the optimized solid‐phase microextraction conditions, satisfactory linearity (5–1000 µg/L) and detection limits (0.38–0.72 µg/kg, S/N = 3) for all the tetracyclines were obtained. The practicality of this method was proved by adding tetracycline, oxytetracycline at three levels to milk, chicken, and fish samples with good recoveries of 77.3–104.4%.  相似文献   

13.
By synthesizing a molecular imprinted polymer as an efficient adsorbent, ciprofloxacin was micro‐extracted from seawater, human blood plasma and tablet samples by pipette‐tip micro solid phase extraction and determined spectrophotometrically. Response surface methodology was applied with central composite design to build a model based on factors affecting on microextraction of ciprofloxacin; including volume of eluent solvent, number of extraction cycles, number of elution cycles, and pH of sample. Other factors that affect extraction efficiency, such as type of eluent solvent, volume of sample, type, and amount of salt were optimized with one‐variable‐at‐a‐time method. Under optimum extraction condition, pH of sample solution was 7.0, volume of eluent solvent (methanol) was 200 µL, volume of sample solution was 10 mL, and the number of extraction and elution cycles was five and seven, respectively, amount of Na2SO4 (as salt) and MIP (as sorbent) were optimized at 150 and 2 mg, respectively. The linear range of the suggested method under optimum extraction factors was 5–150 µg/L with a limit of detection of 1.50 µg/L for the analyte. Reproducibility of the method (as relative standard deviation) was better than 7%.  相似文献   

14.
The herbicides in naked oat (Avena nuda L.) samples were extracted, separated, and determined by using ionic‐liquid‐based matrix solid‐phase dispersion‐solvent flotation coupled with high‐performance liquid chromatography. The experimental parameters were optimized and evaluated by a univariate method and orthogonal experiment. A good linear relationship was obtained in the range of 5–5000 µg/kg, and the linear correlation coefficient are between 0.9989~0.9993. The quantification limits for alachlor, metazachlor, propanil, acetochlor, pretilachlor, metolachlor, and butachlor are 5.03, 2.62, 2.73, 4.58, 7.28, 5.05, 5.78 µg/kg, respectively. The average recoveries of the acetanilide herbicides at spiked concentrations of 10, 100, and 500 µg/kg ranged from 92.1 to 104.7%, and relative standard deviations were equal to or lower than 2.9%.  相似文献   

15.
Three methods were developed and validated for determination of nemonoxacin in human feces and its major metabolite, nemonoxacin acyl‐β‐ d ‐glucuronide, in human urine and feces. Nemonoxacin was extracted by liquid–liquid extraction in feces homogenate samples and nemonoxacin acyl‐β‐ d ‐glucuronide by a solid‐phase extraction procedure for pretreatment of both urine and feces homogenate sample. Separation was performed on a C18 reversed‐phase column under isocratic elution with the mobile phase consisting of acetonitrile and 0.1% formic acid. Both analytes were determined by liquid chromatography–tandem mass spectrometry with positive electrospray ionization in selected reaction monitoring mode and gatifloxacin as the internal standard. The lower limit of quantitation (LLOQ) of nemonoxacin in feces was 0.12 µg/g and the calibration curve was linear in the concentration range of 0.12–48.00 µg/g. The LLOQ of the metabolite was 0.0010 µg/mL and 0.03 µg/g in urine and feces matrices, while the linear range was 0.0010–0.2000 µg/mL and 0.03–3.00 µg/g, respectively. Validation included selectivity, accuracy, precision, linearity, recovery, matrix effect, carryover, dilution integrity and stability, indicating that the methods can quantify the corresponding analytes with excellent reliability. The validated methods were successfully applied to an absolute bioavailability clinical study of nemonoxacin malate capsule. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
In this study, an effective speed‐regulated directly suspended droplet microextraction method was developed to condense pesticide residues from teas through dispersive solid‐phase extraction prior to analysis by gas chromatography with tandem mass spectrometry. The extractant was intentionally dispersed into the sample solution in the form of globules through high‐speed agitation. This procedure increases the contact area between the binary phases and shortens the distribution equilibrium time. The fine globules reassembled by decelerating stirring speed, the extractant could be taken out for gas chromatography with tandem mass spectrometry. Recovery studies were performed under optimized extraction conditions by using matrix blanks fortified with pesticides at three concentrations (10, 50, and 100 µg/kg). Over 87% of the recoveries for the analytes in four tea matrices were acceptable given their recovery ranges of 70–120% and relative standard deviations of ≤20%. The limits of quantification of most pesticides were lower than 10 µg/kg and thus satisfied the requirements for maximum residue levels prescribed by the European Community. A total of 38 tea samples from local markets were analyzed by using the proposed method. Results showed that chlorpyrifos was the most frequently detected pesticide in teas. The method is a potential choice for the routine monitoring of pesticide residues in complex matrices.  相似文献   

17.
A method for determining amitraz and 2,4‐dimethylaniline in honey was established by using ultra‐high‐performance liquid chromatoghaphy and Q Exactive after applying quick, easy, cheap, effective, rugged, and safe extracting process. A suitable extraction method was designed to extract the amitraz and 2,4‐dimethylaniline after a suitable amount of honey samples was dissolved. A Thermo Syncronis C18 column (100 × 2.1 mm, 1.7 μm) was used for chromatographic separation of the samples. Then the two compounds were quantitatively analyzed via a program of Q Exactive. The linearity of amitraz and 2,4‐dimethylaniline was good in the concentration range of 0.5–100 μg/L, and the correlation coefficient R2 was >0.99. The average recovery and relative standard deviation of each component were 81.3–90.0% and 5.1–7.2%. The 24‐ and 48‐h test results showed that the sample needed to be tested within 24 h. The limit of detection was 0.1 μg/kg for amitraz and 2,4‐dimethylaniline, whereas for both the limit of quantitation was 0.3 μg/kg.  相似文献   

18.
A rapid high‐performance liquid chromatographic method was developed and validated for determination of tetrahydropalmatine (THP), an active component of Rhizoma Corydalis, in rat plasma. The samples were prepared using protein precipitation and separated on an Agilent XDB‐C18 column (150 × 4.6 mm, 5 µm) with the mobile phase consisting of methanol–0.1% phosphate acid solution, adjusted with triethylamine to pH 5.5 (65:35). Good linearity was found within 0.10–10.00 µg/mL of THP in rat plasma sample. The intra‐ and inter‐day precision values were less than 10%. The developed method was successfully applied to assess the pharmacokinetics of THP in spontaneously hypertensive rats (SHR) and normotensive rats. After oral administration of a single dose of THP (60 mg/kg), the maximum plasma concentrations were 6.15 ± 2.1 and 7.54 ± 2.9 µg/mL for normotensive rats and SHR, respectively. The mean values of AUC0–∞ of THP in SHR were 81.44 ± 45.0 µg h/mL, significantly higher (p < 0.05) than in normotensive rats (44.06 ± 19.6 µg h/mL). The t1/2 and MRT in SHR were much longer than that in healthy Sprague–Dawley rats, indicating slow elimination of THP in SHR. The results indicated that there are some differences in pharmacokinetics of THP in SHR and Sprague–Dawley rats and it is very important to investigate the pharmacokinetic properties of drugs in pathological conditions. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
A simple, sensitive and rapid method has been developed for simultaneous separation and quantification of three different drugs: oxytocin (OT), norfloxacin (NOR) and diclofenac (DIC) sodium in milk samples using capillary electrophoresis (CE) with UV detection at 220 nm. Factors affecting the separation were pH, concentration of buffer and applied voltage. Separation was obtained in less than 9 min with sodium tetraborate buffer of pH 10.0 and applied voltage 30 kV. The separation was carried out from uncoated fused silica capillary with effective length of 50 cm with 75 µm i.d. The carrier electrolyte gave reproducible separation with calibration plots linear over 0.15–4.0 µg/mL for OT, 5–1000 µg/mL for NOR and 3–125 µg/mL for DIC. The lower limits of detection (LOD) were found to be 50 ng/mL for OT, and 1 µg/mL for NOR and DIC. The method was validated for the analysis of drugs in milk samples and pharmaceutical preparations with recovery of drugs within the range 96–100% with RSD 0.9–2.8%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
In this study, a hydrophilic deep eutectic solvent was synthesized as a carrier and disperser of magnetic nanoparticles based on ferrofluid and used to develop the dispersive micro‐solid‐phase extraction method. Ethylene glycol/tetramethylammonium chloride deep eutectic solvent and SiO2@Fe3O4 were used to provide the highly stable ferrofluid with strong sorbing properties without any additional stabilizer, which was employed to extract and determine morin in apple and grape juices, diluted and acidic extract of dried onion, and green tea infusion samples. The dispersibility of SiO2@Fe3O4 and prevention of its aggregation in the sample solution were improved using the deep eutectic solvent‐based ferrofluid. Also, it facilitated the fast injection of sorbent into the sample solution that led to an increase of the contact surface between the sorbent and analyte, and reduction of the extraction time and consumption of the sorbent. The important experimental parameters influencing the extraction efficiency of morin were examined. Under the optimal conditions, a linear calibration curve was obtained in the range of 3–500 µg/L with a determination coefficient of 0.9994. The limits of detection and quantification were of 0.91 and 2.98 µg/L, respectively. While an extraction recovery of 97.7% with relative standard deviation of 3.8% (interday) was obtained via three replicated measurements on a 30 µg/L of morin standard solution, the enrichment factor was 39.1. Finally, this method was successfully used to extract and preconcentrate morin in various samples, followed with their determination by high‐performance liquid chromatography with ultraviolet detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号