首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An alternative CE‐(indirect ultraviolet) method for the analysis of inorganic and organic anions in ethylene glycol‐based engine coolants is presented using a BGE with 4 mM pyromellitic acid and 3.4 mM 1,6‐hexamethylene diamine, pH 3. Baseline separation of six inorganic (e.g. nitrite, nitrate, and sulfate) and five organic anions (e.g. acetic and glycolic acid) was achieved. Quantification of 8 out of 11 specified anions was possible in stressed engine coolant samples after simple aqueous dilution. LODs between 0.8 and 15.1 mg/L with RSD values of peak areas between 2.6 and 11.9% were obtained. Some limitations due to matrix effects can be overcome with slight adaptations of the BGE. The flexibility of the method is vital regarding the increasing demands for the composition of engine coolants for pollution reduction.  相似文献   

2.
A portable capillary electrophoretic system with contactless conductivity detection was used for fingerprint analysis of postblast explosive residues from commercial organic and improvised inorganic explosives on various surfaces (sand, concrete, metal witness plates). Simple extraction methods were developed for each of the surfaces for subsequent simultaneous capillary electrophoretic analysis of anions and cations. Dual‐opposite end injection principle was used for fast (<4 min) separation of 10 common anions and cations from postblast residues using an optimized separation electrolyte composed of 20 mM MES, 20 mM l ‐histidine, 30 μM CTAB and 2 mM 18‐crown‐6. The concentrations of all ions obtained from the electropherograms were subjected to principal component analysis to classify the tested explosives on all tested surfaces, resulting in distinct cluster formations that could be used to verify (each) type of the explosive.  相似文献   

3.
R. Naidu  Z. L. Chen 《Chromatographia》2001,54(7-8):495-500
Summary Indirect UV detection in capillary zone electrophoresis (CZE) is frequently used for the determination of inorganic anions and carboxylic acids. However, there are few reports on direct UV detection of these solutes in real samples. This paper describes the use of direct UV detection of inorganic anions and organic acids in environmental samples using co-electroosmotic capillary zone electrophoresis (co-CZE) at 185 nm. The best separation and detection of the solutes was achieved using a fused silica capillary with an electrolyte containing 25 mM phosphate, 0.5 mM tetradecyltrimethylammonium bromide (TTAB) and 15% acetonitrile (v/v) at pH 6.0. Four common inorganic anions (Cl, NO2 , NO3 and SO4 2−) and 11 organic acids (oxalic, formic, fumaric, tartaric, malonic, malic, citric, succinic, maleic, acetic, and lactic acid), were determined simultaneously in 15 min. Linear calibration plots for the test solutes were obtained in the range 0.02–0.5 mM with detection limits ranging from 1–9 μM depending on the analyte. The proposed method was successfully used to determine inorganic anions and carboxylic acids in soil and plant tissue extracts with direct injection of the sample.  相似文献   

4.
A capillary electrophoretic method with UV detection for separation and quantitation of perfluorocarboxylic acids (PFCAs) from C6-PFCA to C12-PFCA has been developed. The optimization of measurement conditions included the choice of the most appropriate type and concentration of buffer in the background electrolyte (BGE), as well as the type and the content of an organic modifier. The optimal separation of investigated PFCAs was achieved with 50 mM phosphate buffer and 40% isopropanol in the BGE using direct UV detection. The optimum wavelength for direct UV detection was optimized at 190 nm. For indirect detection, several chromophores were studied. Five mM 3,5-Dinitrobenzoic acid (3,5-DNBA) in 20 mM phosphate buffer BGE and indirect UV detection at 280 nm gave the optimal detection and separation performance for the investigated PFCAs. The possibility of on-line preconcentration of solutes by stacking has been examined for indirect detection. The detection limits (LODs) determined for direct UV detection ranged from 2 microg/mL for C6-PFCA to 33 microg/mL for C12-PFCA. The LODs obtained for indirect UV detection were comparable to those obtained for direct UV detection.  相似文献   

5.
A novel capillary electrophoresis (CE) approach has been developed for the simultaneous rapid separation and identification of common environmental inorganic anions and cations from a single sample injection. The method utilised a sequential injection-capillary electrophoresis instrument (SI-CE) with capacitively-coupled contactless conductivity detection (C4D) constructed in-house from commercial-off-the-shelf components. Oppositely charged analytes from a single sample plug were simultaneously injected electrokinetically onto two separate capillaries for independent separation and detection. Injection was automated and may occur from a syringe or be directly coupled to an external source in a continuous manner. Software control enabled high sample throughput (17 runs per hour for the target analyte set) and the inclusion of an isolation valve allowed the separation capillaries to be flushed, increasing throughput by removing slow migrating species as well as improving repeatability. Various environmental and industrial samples (subjected only to filtering) were analysed in the laboratory with a 3 min analysis time which allowed the separation of 23 inorganic and small organic anions and cations. Finally, the system was applied to an extended automated analysis of Hobart Southern Water tap water for a period of 48 h. The overall repeatability of the migration times of a 14 analyte standard sample was less than 0.74% under laboratory conditions. LODs ranged from 5 to 61 μg L−1. The combination of automation, high confidence of peak identification, and low limits of detection make this a useful system for the simultaneous identification of a range of common inorganic anions and cations for discrete or continuous monitoring applications.  相似文献   

6.
Capillary ion electrophoresis–capacitively coupled contactless conductivity detection (CIE-C4D) with a polyvinyl alcohol chemically coated capillary (PVA capillary) was used to analyze inorganic cations (Na+, K+, NH4+, Mg2+, and Ca2+) commonly found in human saliva. The PVA capillary, which was made by our laboratory, minimized electro-osmotic flow in the wide pH range of the background electrolyte (BGE), and the PVA layer adsorbed to capillary wall did not affect the conductimetric background level. In this study, we determined an optimized BGE of 30 mM lactic acid/histidine plus 3 mM 18-crown-6 for the CIE-C4D system using the PVA capillary, which could simultaneously improve the separation of Mg2+ and Ca2+ from Na+ and that of K+ from NH4+. This system obtained highly reproducible separation of cations in human saliva samples within 8 min at 20 kV without deprotonation. The quantifiability of cations in human saliva samples on the CIE-C4D system was demonstrated through identification by ion chromatography with satisfactory results.  相似文献   

7.
Capillary zone electrophoresis (CZE) with indirect UV detection was developed for the simultaneous determination of inorganic anions and organic acids in environmental samples. Various aromatic acids (benzoic, phthalic, trimellitic, and pyromellitic acids) were evaluated as background electrolytes (BGEs) to give high resolution and detection sensitivity. Co-electroosmotic conditions such as the concentration of BGE, electrolyte pH, and EOF modifier were systematically investigated. Three inorganic anions and ten organic acids were determined simultaneously in 10 min using an electrolyte containing 10 mM phthalic acid, 0.5 mM myristyltrimethylammonium bromide (MTAB), and 5% methanol (MeOH) (v/v) at pH 5.60. Linear plots for the test solutes were obtained in the concentration range 0.01–1.0 mM with detection limits in the range 5–30 μM. The proposed method was successfully demonstrated for the determination of inorganic anions and organic acids in natural water, soil, and plant extracts after direct sample injection.  相似文献   

8.
Kubán P  Hauser PC 《Electrophoresis》2005,26(16):3169-3178
Quantitative total ionic analysis of alcoholic and nonalcoholic beverages was performed by microchip capillary electrophoresis with external contactless conductivity detection. An electrolyte solution consisting of 10.5 mM histidine, 50 mM acetic acid, and 2 mM 18-crown-6 at pH 4.1 was used for the determination of NH(4) (+), K(+), Ca(2+), Na(+), and Mg(2+). Fast analysis of Cl(-), NO(3) (-), and SO(4) (2-) was achieved in 20 mM 2-(N-morpholino)ethanesulfonic acid /histidine electrolyte solution at pH 6.0 and the simultaneous separation of up to 12 inorganic and organic anions was performed in a solution containing 10 mM His and 7 mM glutamic acid at pH 5.75. Limits of detection ranged from 90 to 250 mug/L for inorganic cations and anions, and from 200 to 2000 mug/L for organic anions and phosphate. Calibration curves showed linear dependencies over one to two orders of magnitude when the stacking effect was minimized by injecting standard solutions prepared in background electrolyte solutions. Total analysis times of 35 and 90 s were achieved for the determination of 5 inorganic cations and for the simultaneous determination of 12 inorganic and organic anions, respectively, which represents a considerable reduction of analysis time compared to conventional separation methods used in food analysis.  相似文献   

9.
Novel CE methods have been developed on portable instrumentation adapted to accommodate a capacitively coupled contactless conductivity detector for the separation and sensitive detection of inorganic anions and cations in post‐blast explosive residues from homemade inorganic explosive devices. The methods presented combine sensitivity and speed of analysis for the wide range of inorganic ions used in this study. Separate methods were employed for the separation of anions and cations. The anion separation method utilised a low conductivity 70 mM Tris/70 mM CHES aqueous electrolyte (pH 8.6) with a 90 cm capillary coated with hexadimethrine bromide to reverse the EOF. Fifteen anions could be baseline separated in 7 min with detection limits in the range 27–240 μg/L. A selection of ten anions deemed most important in this application could be separated in 45 s on a shorter capillary (30.6 cm) using the same electrolyte. The cation separation method was performed on a 73 cm length of fused‐silica capillary using an electrolyte system composed of 10 mM histidine and 50 mM acetic acid, at pH 4.2. The addition of the complexants, 1 mM hydroxyisobutyric acid and 0.7 mM 18‐crown‐6 ether, enhanced selectivity and allowed the separation of eleven inorganic cations in under 7 min with detection limits in the range 31–240 μg/L. The developed methods were successfully field tested on post‐blast residues obtained from the controlled detonation of homemade explosive devices. Results were verified using ion chromatographic analyses of the same samples.  相似文献   

10.
This study reports a reinvestigation of background electrolyte selection strategy for performance improvement in CE‐LIF of peptides and proteins. This strategy is based on the employment of high concentrations of organic species in BGE possessing high buffer capacity and low specific conductivity in order to ensure excellent stacking preconcentration and separation resolution of fluorescently tagged peptides and proteins. Unlike universal UV detection, the use of such BGEs at high concentrations does not lead to degradation of LIF detection signals at the working excitation and emission wavelengths. At the same buffer ionic strength, pH and electric field, an “inorganic‐species‐free” BGE (or ISF BGE) for CE‐LIF of fluorescently labeled beta amyloid peptide Aβ 1–42 (a model analyte) offered a signal intensity and peak efficiency at least three‐times higher than those obtained with a conventional BGE normally used for CE‐LIF, while producing an electric current twice lower. Good peak performance (in terms of height and shape) was maintained when using ISF BGEs even with samples prepared in high‐conductivity phosphate buffer saline matrix. The advantageous features of such BGEs used at high concentrations over conventional ones in terms of high separation resolution, improved signal intensities, tuning of EOF magnitudes and minimization of protein adsorption on an uncoated fused silica capillary are demonstrated using Alexa‐488‐labelled trypsin inhibitor. Such BGE selection approach was applied for investigation of separation performance for CE‐LIF of ovalbumin labelled with different fluorophores.  相似文献   

11.
A simple, rapid method using CE and microchip electrophoresis with C4D has been developed for the separation of four nonsteroidal anti-inflammatory drugs (NSAIDs) in the environmental sample. The investigated compounds were ibuprofen (IB), ketoprofen (KET), acetylsalicylic acid (ASA), and diclofenac sodium (DIC). In the present study, we applied for the first time microchip electrophoresis with C4D detection to the separation and detection of ASA, IB, DIC, and KET in the wastewater matrix. Under optimum conditions, the four NSAIDs compounds could be well separated in less than 1 min in a BGE composed of 20 mM His/15 mM Tris, pH 8.6, 2 mM hydroxypropyl-beta-cyclodextrin, and 10% methanol (v/v) at a separation voltage of 1000–1200 V. The proposed method showed excellent repeatability, good sensitivity (LODs ranging between 0.156 and 0.6 mg/L), low cost, high sample throughputs, portable instrumentation for mobile deployment, and extremely lower reagent and sample consumption. The developed method was applied to the analysis of pharmaceuticals in wastewater samples with satisfactory recoveries ranging from 62.5% to 118%.  相似文献   

12.
《Electrophoresis》2018,39(14):1802-1807
An improved method for the concurrent determination and separation of cations and anions by microchip electrophoresis with capacitively coupled contactless conductivity detection (ME‐C4D) is described. Two kinds of microchip structures were designed. The first microchip has a long bent separation channel. And for the defects of the first microchip, the second microchip with a Y‐type separation channel has been proposed. The background electrolyte (BGE) composed of 20 mm His/MES and 0.01 mm CTAB was optimized for inhibiting the electroosmotic flow (EOF). Due to the low electroosmotic flow, the cations and anions migrate in opposite directions and can be separated from each other. With the precisely controlled high‐voltage, cations and anions can be migrated in microchannels according to our requirements and sequentially detected by a C4D detector built in‐house. Samples containing K+, Na+, Li+, Cl, F and PO43− were analyzed simultaneously in a single run (within 140 s) by both methods. The reproducibility obtained by both methods remained below 5% for migration time and within 3.5–9.1% for peak areas. The proposed concurrent determination methods are inexpensive, simple, fast, ease of operation, high degree of integration.  相似文献   

13.
A new approach for simultaneous separation of small inorganic and organic anions and metal cations by capillary electrophoresis is demonstrated. Metal cations in the sample are transformed into their chelates with EDTA and are separated together with the anions using an anionic separation mode. Simultaneous separation of 19 common anions and cations was achieved in about 6 min with the electrolyte containing 5 mM K2CrO4, 3 mM boric acid, 35 microM cetyltrimethylammonium bromide and 12 microM EDTA at pH 8. Limits of detection (s/n = 3) were in the range from 4 ppb for Cl- up to 1250 ppb for Cu-EDTA and RSDs of peak areas ranged from 1.4% for Cl- up to 8.5% for Mn-EDTA chelate. The practical applicability of the method was demonstrated on the analysis of anions and cations in various water samples.  相似文献   

14.
The analysis of ionic content of exhaled breath condensate (EBC) from one single breath by CE with C4D is demonstrated for the first time. A miniature sampler made from a 2‐mL syringe and an aluminum cooling cylinder for collection of EBC was developed. Various parameters of the sampler that influence its collection efficiency, repeatability, and effect of respiratory patterns were studied in detail. Efficient procedures for the cleanup of the miniature sampler were also developed and resulted in significant improvement of sampling repeatability. Analysis of EBC was performed by CE‐C4D in a 60 mM MES/l ‐histidine BGE with 30 μM CTAB and 2 mM 18‐crown‐6 at pH 6 and excellent repeatability of migration times (RSD < 1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 12 inorganic anions, cations, and organic acids was obtained. It has been shown that the breathing pattern has a significant impact on the concentration of the analytes in the collected EBC. As the ventilatory pattern can be easily controlled during single exhalation, the developed collection system and method provides a highly reproducible and fast way of collecting EBC with applicability in point‐of‐care diagnostics.  相似文献   

15.
Basic operation principles of a lightweight, low power, low cost, portable ion chromatograph utilizing open tubular ion chromatography in capillary columns coated with multi-layer polymeric stationary phases are demonstrated. A minimalistic configuration of a portable IC instrument was developed that does not require any chromatographic eluent delivery system, nor sample injection device as it uses gravity-based eluent flow and hydrodynamic sample injection adopted from capillary electrophoresis. As a detection device, an inexpensive commercially available capacitance sensor is used that has been shown to be a suitable substitute for contactless conductivity detection in capillary separation systems. The built-in temperature sensor allows for baseline drift correction typically encountered in conductivity/capacitance measurements without thermostating device. The whole instrument does not require any power supply for its operation, except the detection and data acquisition part that is provided by a USB port of a Netbook computer. It is extremely lightweight, its total weight including the Netbook computer is less than 2.5 kg and it can be continuously operated for more than 8 h. Several parameters of the instrument, such as detection cell design, eluent delivery systems and data treatment were optimized as well as the composition of eluent for non-suppressed ion chromatographic analysis of common inorganic cations (Na+, NH4+, K+, Cs+, Ca2+, Mg2+, transition metals). Low conductivity eluents based on weakly complexing organic acids such as tartaric, oxalic or pyridine-2,6-dicarboxylic acids were used with contactless capacitance detection for simultaneous separation of mono- and divalent cations. Separation of Na+ and NH4+ cations was optimized by addition of 18-crown-6 to the eluent. The best separation of 6 metal cations commonly present in various environmental samples was accomplished in less than 30 min using a 1.75 mM pyridine-2,6-dicarboxylic acid and 3 mM 18-crown-6 eluent with excellent repeatability (below 2%) and detection limits in the low micromolar range. The analysis of field samples is demonstrated; the concentrations of common inorganic cations in river water, mineral water and snow samples were determined.  相似文献   

16.
Hopper KG  Leclair H  McCord BR 《Talanta》2005,67(2):304-312
A novel electrolyte has been developed for the simultaneous separation of cations and anions in low explosive residue by capillary electrophoresis. This electrolyte contains 15 mM α-hydroxyisobutyric acid (HIBA) as the buffer, 6 mM imidazole as the cation chromophore, 3 mM 1,3,6-naphthalenetrisulfonic acid (NTS) as the anion chromophore, 4 mM 18-crown-6 ether as a cation selectivity modifier, and 5% (v/v) acetonitrile as an organic modifier. The pH was adjusted to 6.5 using tetramethylammonium hydroxide (TMAOH), an electroosmotic flow modifier. The method was optimized by varying the concentrations of α-HIBA, imidazole, and 1,3,6-NTS at three different pH values. The results provided a simultaneous indirect photometric analysis of both anions and cations with detection limits ranging from 0.5 to 5 ppm for anions and from 10 to 15 ppm for cations with a total run time of under 7 min. The method was then applied to the analysis of Pyrodex® RS and black powder, as well as several smokeless powders. The results obtained were consistent with previously reported results for separate anion and cation analysis and provide a faster, more complete analysis of each sample in a single chromatographic run.  相似文献   

17.
Capillary zone electrophoresis with indirect UV detection was developed for the simultaneous analysis of inorganic anions and organic acids using a mixed solution of 2,6-pyridinedicarboxylic acid and cetyltrimethylammonium hydroxide as the background electrolyte (BGE). The parameters which influence the separation, such as indirect UV detection wavelength, BGE conditions, applied voltage and extraction conditions were investigated. Thirteen inorganic anions and organic acids were detected within 20 min. The calibration curves of each analyte were linear with correlation coefficients greater than 0.991. The relative standard deviations (= 10) of the peak areas ranged from 0.6% to 3.3%. The detection limits for these species ranged from 0.4 to 1.4 mg/L at a signal-to-noise ratio of 3. The recovery rate of each analyte was more than 80% under optimised extraction conditions, except for nitrite. The proposed method was applied towards the analysis of inorganic anions and organic acids in the atmospheric particulate matter using an Andersen sampler. The particle size of the particulate matter was determined, but not the size of the anions.  相似文献   

18.
Seventeen inorganic and organic anions, that normally are insufficiently separated via ion chromatography, were completely separated by the addition of an organic solvent to a solution of BGE combined with an adjustment of the apparent pH via CE in combination with indirect UV absorbance detection. Methanol, ethanol, and acetonitrile were examined for their utility in manipulating the selective separation of anions. Methanol and acetonitrile were better modifiers than ethanol at enhancing the resolution of anions comigrating in an aqueous solution of BGE. Methanol was selected as the modifier that provided the largest separation window that could achieve a complete separation of the target analytes. Via the use of methanol, manipulation of the selectivity between inorganic anions and that between inorganic and organic anions was enhanced, but the separation between organic anions remained difficult when only methanol was used. By varying the apparent pH of the BGE in the presence of 10% v/v methanol, however, the separation selectivity between organic anions was substantially improved. Eventually, 7 inorganic and 10 organic anions were simultaneously separated using BGE at a pH of 6.3 in the presence of 10% v/v methanol.  相似文献   

19.
This work focuses on the development of a CE method allowing, for the first time, the simultaneous separation of the underivatized first seven cellodextrin oligomers (glucose, cellobiose, cellotriose, cellotetraose, cellopentaose, cellohexaose, and celloheptaose), with a view to analyze the hydrolysates obtained after partial acid depolymerization of nitrocellulose, and eight carbohydrates (ribose, xylose, fructose, mannose, galactose, maltose, lactose, and sucrose), which might be potential interfering compounds in explosives samples. Separation was achieved with a highly alkaline BGE containing sodium chloride and direct mid‐UV‐absorbance detection was performed after photo‐oxidation in the detection window. EOF was reversed to speed up the analysis using a dynamic capillary coating by hexadimethrine bromide. A central composite design was carried out to determine the effects of BGE conductivity and sodium hydroxide concentration on resolutions between neighboring peaks, and analysis time. A desirability analysis on modeled responses was applied to maximize resolutions and to minimize analysis time. The simultaneous analysis in 20 min total runtime of the 15 carbohydrates plus internal reference (naphthalene sulfonate) was carried out at 25°C with a BGE composed of 77.4 mM NaOH and 183 mM NaCl to adjust the conductivity at the optimum value. Finally, the resolution robustness was checked. This new method should also be of interest to monitor food and nonfood crop products.  相似文献   

20.
A background electrolyte (BGE) containing a 100 mM concentration of an alkylammonium cation with ethyl, propyl or butyl groups provides an excellent medium for separation of anions by capillary electrophoresis (CE). Two major effects were noted. Use of one of a series of alkylammonium cations in the BGE at a selected pH provides a simple and effective way to vary and control electroosmotic flow (EOF) over a broad range. It is believed that the alkylammonium cations are coated onto the capillary surface through a reversible dynamic equilibrium. Secondly, alkylammonium cations modify the electrophoretic migration of sample anions and the electroosmotic migration of neutral organic analytes by association interaction. This selective interaction results in improved anion separations and permits the simultaneous separation of neutral analytes. The degree of association interaction varies with the bulk and hydrophobicity of the alkylammonium cations. Incorporation of an aliphatic amine salt of moderate molecular weight in the running electrolyte provides a valuable new way to vary the migration times of sample anions and to optimize their resolution. The interactions between alkylammonium cations and sample anions or neutral organics appear to take place entirely within the liquid phase and do not require a polymeric or micellar pseudo phase.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号