首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An immobilized pH gradient was directly constructed on the inner wall of a microfluidic chip channel by photoimmobilizing focused carrier ampholytes onto the wall. A mixture of carbonic anhydrase, myoglobin, and trypsin inhibitor was successfully isoelectric‐focused and separated with good linearity between the pI values of proteins and the location of the focused bands. Furthermore, coating methods for the resistance of protein nonselective adsorption and simultaneously for pH gradient photocoupling were screened. The PEG‐silane coating method was found to be better than the cross‐linked polyacrylamide coating and aminosilane modification methods. Finally, based on the open tubular column mode of carrier ampholytes’ immobilization and effective antiadsorption coating, the immobilized pH gradient was reused and the chip was recycled for the first time. By virtue of its remarkable features including simplicity, convenience, high efficiency of protein enrichment and separation, and potential for coupling site‐selective IEF with other analytical or separation techniques, this novel method promises to be useful in several applications related with zwitterionic biomolecules.  相似文献   

2.
3.
《Electrophoresis》2017,38(24):3147-3154
Antimicrobial peptides (AMPs) are usually small and cationic biomolecules with broad‐spectrum antimicrobial activities against pathogens. Purifying them from complex samples is essential to study their physiochemical properties. In this work, free‐flow zone electrophoresis (FFZE) was utilized to purify AMPs from yeast fermentation broth. Meanwhile, gel filtration chromatography (GFC) was conducted for comparison. The separation efficiency was evaluated by SDS‐PAGE analysis of the fractions from both methods. Our results demonstrated as follows: (i) FFZE had more than 30‐fold higher processing capacity as compared with GFC; (ii) FFZE could achieve 87% purity and 89% recovery rate while in GFC these parameters were about 93 and 82%, respectively; (iii) the former had ∼2‐fold dilution but the latter had ∼13‐fold dilution. Furthermore, Tricine‐SDS‐PAGE, Native‐PAGE, and gel IEF were carried out to characterize the purified AMPs. We found that two peptides existed as a pair with the molecular mass of ∼5.5 and 7.0 kDa, while the same pI 7.8. These two peptides were proved to have the antimicrobial activity through the standardized agar diffusion method. Therefore, FFZE could be used to continuously purify AMPs with high bioactivity, which will lead to its wide application in the clinical and pharmaceutical fields.  相似文献   

4.
We report a microfluidic paper based analytical device implementing ion concentration polarization (ICP) for rapid pre-concentration of Escherichia coli in water. The fabricated device consists of a paper channel with a Nafion® membrane and in-built micro wire electrodes to supply electric voltage to induce the ICP effect. E. coli cells were stained with SYTO 9 and fluorescence was used as a sensing method. The device achieved high concentration factor up to 2 × 105 within minutes. The effect of total ion concentration, on ICP and fluorescence intensity was studied. The reported device and method are suitable and effective for detection of E. coli during ballast water quality monitoring, coastal water quality monitoring where high salinity water is present.  相似文献   

5.
A novel microfluidic method of continually detecting and counting beads‐labeled cells from a cell mixture without fluorescence labeling was presented in this paper. The detection system is composed of a microfluidic chip (with a permanent magnet inserted along the channel), a signal amplification circuit, and a LabView® based data acquisition device. The microfluidic chip can be functionally divided into separation zone and detection zone. By flowing the pre‐labeled sample solution, the target cells will be sequentially separated at the separation zone by the permanent magnet and detected and counted at the detection zone by a microfluidic resistive pulse sensor. Experiments of positive separation and detection of T‐lymphocytes and negative separation and detection of cancer cells from the whole blood samples were carried out to demonstrate the effectiveness of this method. The methodology of utilizing size difference between magnetic beads and cell‐magnetic beads complex for beads‐labeled cell detection is simple, automatic, and particularly suitable for beads‐based immunoassay without using fluorescence labeling.  相似文献   

6.
Zhang L  Yin X 《Electrophoresis》2007,28(8):1281-1288
A simple and powerful microfluidic array chip-based electrophoresis system, which is composed of a 3-D microfluidic array chip, a microvacuum pump-based negative pressure sampling device, a high-voltage supply and an LIF detector, was developed. The 3-D microfluidic array chip was fabricated with three glass plates, in which a common sample waste bus (SW(bus)) was etched in the bottom layer plate to avoid intersecting with the separation channel array. The negative pressure sampling device consists of a microvacuum air pump, a buffer vessel, a 3-way electromagnet valve, and a vacuum gauge. In the sample loading step, all the six samples and buffer solutions were drawn from their reservoirs across the injection intersections through the SW(bus) toward the common sample waste reservoir (SW(T)) by negative pressure. Only 0.5 s was required to obtain six pinched sample plugs at the channel crossings. By switching the three-way electromagnetic valve to release the vacuum in the reservoir SW(T), six sample plugs were simultaneously injected into the separation channels by EOF and electrophoretic separation was activated. Parallel separations of different analytes are presented on the 3-D array chip by using the newly developed sampling device.  相似文献   

7.
Fibroblasts and tumor cells have been involved in the process of cancer development, progression and therapy. Here, we present a simple microfluidic device which enables to study the interaction between fibroblasts and tumor cells by indirect contact co‐culture. The device is composed of multiple cell culture chambers which are connected by a parallel of cell migration regions, and it enables to realize different types of cells to communicate each other on the single device. In this work, human embryonic lung fibroblasts cells were observed to exhibit obvious migration towards tumor cells instead of normal epithelial cells on the co‐culture device. Moreover, transdifferentiation of human embryonic lung fibroblast cells was recognized by the specific expression of α‐smooth musle actin, indicating the effect of tumor cells on the behavior of fibroblasts. Furthermore, multiple types of cell co‐culture can be demonstrated on the single device which enables to mimic the complicated microenviroment in vivo. The device is simple and easy to operate, which enables to realize real‐time observation of cell migration after external stimulus. This microfluidic device allows for the characterization of various cellular events on a single device sequentially, faciliating the better understanding of interaction between heterotypic cells in a more complex microenvironment.  相似文献   

8.
Shiddiky MJ  Park DS  Shim YB 《Electrophoresis》2005,26(24):4656-4663
A simple and fast method for electrochemical detection of amplified fragments by PCR was successfully developed using CE in a microfluidic device with a modified screen-printed carbon electrode (SPCE). The surfaces of the SPCE were modified with poly-5,2'-5',2'-terthiophene-3'-carboxylic acid, which improves the analysis performance by lowering the detection potential, enhancing the S/N characteristics, and avoiding electrode poisoning. DNA fragments amplified by PCR were separated within 210 s in a 75.5 mm-long coated-separation channel at a separation field strength of -200 V/cm. To minimize the sample adsorption into the inner surface of the capillary wall, which disturbs the separation, a dynamically coated capillary with an acrylamide solution was used. Furthermore, the analysis procedure was simplified and rendered reproducible by using 0.50% w/v hydroxyethylcellulose as a separation matrix in a coated channel. The reproducibility of the analysis employing the coated channel yielded RSD of 4.3% for the peak areas and 1.4% for the migration times in eight repetitive measurements at a modified electrode, compared with 21.3 and 9.4% for a bare electrode. The sensitivity of the assay was 18.74 pAs/(pg/microL) with a detection limit of 584.31 +/- 1.3 fg/microL.  相似文献   

9.
A novel microfluidic paper‐based analytical device (μPAD) utilizing a nitrocellulose (NC) membrane to detect IgG antibodies through a colorimetric analysis is described. The μPAD was constructed using layered polyethylene terephthalate (PET) and pressure‐sensitive adhesives (PSA). The biotin labeled Goat Anti‐Mouse IgG antibody was spotted and dried on the NC channel prior to subjecting it to a series of wash solutions (Tris‐tween), increasing concentrations of alkaline phosphatase conjugated to streptavidin (Strep‐ALP), and para‐nitrophenyl phosphate (p‐NPP) realizing a vibrant yellow color. The reaction proceeds for 10 min before applying the p‐NPP stop solution. The device was then dried, scanned, and analyzed yielding a linear range of inverse yellow color intensities versus Strep‐ALP concentrations. The development of this simple μPAD should further facilitate the use of NC in colorimetric assays to detect and quantitate antibodies.  相似文献   

10.
MaiLuoNing injection is a traditional Chinese medicine that used clinically since the 1950s in China. However, anaphylactic reactions, through the potentiation of mast cell degranulation, have been reported. In the present study, a rat basophilic leukemia‐2H3 cell membrane chromatography coupled with high‐performance liquid chromatography and electrospray ionization‐ion trap‐time of flight‐mass spectrometry method was established for screening, analyzing, and identifying the potential anaphylactic components of MaiLuoNing injection. Harpagoside, a potential degranulator of rat basophilic leukemia‐2H3 cells, was retained in rat basophilic leukemia‐2H3 cell membrane chromatography. We aimed to evaluate the retained components to determine which of those were capable of inducing degranulation of basophilic leukemia cells. A β‐hexosaminidase assay revealed that harpagoside can induce rat basophilic leukemia‐2H3 cell degranulation in a dose‐dependent manner. BLBA/c mice also exhibit passive cutaneous anaphylaxis in response to harpagoside. These results indicate that rat basophilic leukemia‐2H3 cell membrane chromatography coupled with high‐performance liquid chromatography and electrospray ionization ion trap time‐of‐flight mass spectrometry is effective in screening for the anaphylactic components of MaiLuoNing injection.  相似文献   

11.
We performed on‐plate enzyme and inhibition assays of glucose 6‐phosphate dehydrogenase using thin‐layer chromatography. The assays were accomplished based on different retardation factors of the substrates, enzyme, and products. All the necessary steps were integrated on‐plate in one developing process, including substrate/enzyme mixing, reaction starting, and quenching as well as product separation. In order to quantitatively measure the enzyme reaction, the developed plate was then densitometrically evaluated to determine the peak area of the product. Rapid and high‐throughput assays were achieved by loading different substrate spots and/or enzyme (and inhibition) spots in different tracks on the plate. The on‐plate enzyme assay could be finished in a developing time of only 4 min, with good track‐to‐track and plate‐to‐plate repeatability. Moreover, we determined the Km values of the enzyme reaction and Ki values of the inhibition (Pb2+ Cd2+ and Cu2+ as inhibitors), as well as the corresponding kinetics using the on‐plate assay. Taken together, our method expanded the application of thin‐layer chromatography in enzyme assays, and it could be potentially used in research fields for rapid and quantitative measurement of enzyme activity and inhibition.  相似文献   

12.
《Electrophoresis》2017,38(7):953-976
Microfluidics has emerged following the quest for scale reduction inherent to micro‐ and nanotechnologies. By definition, microfluidics manipulates fluids in small channels with dimensions of tens to hundreds of micrometers. Recently, microfluidics has been greatly developed and its influence extends not only the domains of chemical synthesis, bioanalysis, and medical researches but also optics and information technology. In this review article, we will shortly discuss an enlightening analogy between electrons transport in electronics and fluids transport in microfluidic channels. This analogy helps to master transport and sorting. We will present some complex microfluidic devices showing that the analogy is going a long way off toward more complex components with impressive similarities between electronics and microfluidics. We will in particular explore the vast manifold of fluidic operations with passive and active fluidic components, respectively, as well as the associated mechanisms and corresponding applications. Finally, some relevant applications and an outlook will be cited and presented.  相似文献   

13.
《Electrophoresis》2018,39(17):2181-2187
A nanoporous poly‐(styrene sulfonate) (poly‐SS) membrane was developed for fast and selective ion transport in a microfluidic chip. The poly‐SS membrane can be photopolymerized in‐situ at arbitrary location of a microchannel, enabling integrated fluidics design in the microfluidic chip. The membrane is characterized by a low hydraulic resistance and a high surface charge to maximize the electroosmotic flow and charge selectivity. The membrane characteristics were investigated by charge‐selective electropreconcentration method. Experimental results show membranes with various percentages of poly‐SS are able to concentrate anions (fluorescein and TRITC‐labeled BSA). The anion‐selective electropreconcentration process is stable and 26‐times faster than previously reported poly‐AMPS (2‐acrylamido‐2‐methyl‐1‐propanesulfonic acid) based system. The electropreconcentration was also demonstrated to depend on the sample valency and buffer concentration.  相似文献   

14.
15.
We established a two‐dimensional strong cation exchange/reversed‐phase liquid chromatography protocol to isolate and purify isoquinoline alkaloids from Corydalis impatiens. Isoquinoline alkaloids were first enriched from a C. impatiens extract in which liposoluble components were removed using a medium‐pressure chromatographic tower containing middle chromatogram isolated gel. A strong cation exchange column was employed to separate and obtain 30 fractions. We chose fractions 22–29 for reversed‐phase liquid chromatography purification using characteristic isoquinoline alkaloid ultraviolet absorption spectra. Several isoquinoline alkaloid fractions (22–29) were further separated, and those of low resolution were isolated via two‐dimensional liquid chromatography in the orthogonal plane. A total of eight novel isoquinoline alkaloids with characteristic ultraviolet spectra were obtained from C. impatiens. We thus demonstrate the benefits of off‐line two‐dimensional strong cation exchange/reversed‐phase liquid chromatography to isolate isoquinoline alkaloids from C. impatiens.  相似文献   

16.
Huangqi (Astragali Radix), a traditional Chinese herb, is widely used in clinical therapy in China. In addition, an anti‐allergic effect of constituents in Huangqi has been reported in the scientific literature. In the present study, cell membrane chromatography coupled online with UHPLC‐ESI‐MS/MS method was developed to screen, analyze and identify the anti‐allergic components of Huangqi. The Laboratory of Allergic Disease 2 (LAD2) cell was used to establish cell membrane chromatography, which was combined with UHPLC‐ESI‐MS/MS. The coupled system was then used to screen anti‐allergic components from Huangqi. Effects of active components were verified by histamine release assay. A component retained on the LAD2 cell membrane chromatography was identified as formononetin. Bioactivity of formononetin was investigated by histamine release assay in LAD2 cells, and it was found that formononetin could inhibit histamine release in a dose‐dependent manner from 1 to 100 μm . The LAD2 cell membrane chromatography online with UHPLC‐ESI‐MS/MS method is an effective technique for screening the anti‐allergic components of Huangqi.  相似文献   

17.
Real‐time nuclear magnetic resonance (NMR) spectroscopy measurements carried out with a bench‐top system installed next to the reactor inside the fume hood of the chemistry laboratory are presented. To test the system for on‐line monitoring, a transfer hydrogenation reaction was studied by continuously pumping the reaction mixture from the reactor to the magnet and back in a closed loop. In addition to improving the time resolution provided by standard sampling methods, the use of such a flow setup eliminates the need for sample preparation. Owing to the progress in terms of field homogeneity and sensitivity now available with compact NMR spectrometers, small molecules dissolved at concentrations on the order of 1 mmol L?1 can be characterized in single‐scan measurements with 1 Hz resolution. Owing to the reduced field strength of compact low‐field systems compared to that of conventional high‐field magnets, the overlap in the spectrum of different NMR signals is a typical situation. The data processing required to obtain concentrations in the presence of signal overlap are discussed in detail, methods such as plain integration and line‐fitting approaches are compared, and the accuracy of each method is determined. The kinetic rates measured for different catalytic concentrations show good agreement with those obtained with gas chromatography as a reference analytical method. Finally, as the measurements are performed under continuous flow conditions, the experimental setup and the flow parameters are optimized to maximize time resolution and signal‐to‐noise ratio.  相似文献   

18.
19.
Copper(II)‐ion imprinted silica gel (Cu‐IISG) sorbent was synthesized by surface imprinting technique and was employed as a selective solid‐phase extraction material for on‐line preconcentration and separation, then coupled with atomic absorption spectrometry (AAS) determination of Cu(II). The higher selectivity coefficient of Cu‐IISG for Cu(II) in the presence of competitive ions such as Fe(III), Ni(II) and Zn(II) was above 411, which was 35 times of NISG. The static adsorption capacity and dynamic adsorption capacity were 41.11 mg g?1 and 16.20 mg g?1, respectively. The Cu‐IISG offered a fast kinetics for the adsorption and desorption of Cu(II), which can be used for on‐line preconcentration and detection. Two certified reference materials of GBW07301a sediment and GBW07401 soil were analyzed and the determined values were in a good agreement with the certified values. The developed method was also successfully applied to the determination of trace copper in tea leaf with satisfactory results (recovery between 96.3% and 102.3%).  相似文献   

20.
A simple, environmentally friendly, and efficient method, based on hollow‐fiber‐supported liquid membrane microextraction, followed by high‐performance liquid chromatography has been developed for the extraction and determination of amlodipine (AML) and atorvastatin (ATO) in water and urine samples. The AML in two‐phase hollow‐fiber liquid microextraction is extracted from 24.0 mL of the aqueous sample into an organic phase with microliter volume located inside the pores and lumen of a polypropylene hollow fiber as acceptor phase, but the ATO in three‐phase hollow‐fiber liquid microextraction is extracted from aqueous donor phase to organic phase and then back‐extracted to the aqueous acceptor phase, which can be directly injected into the high‐performance liquid chromatograph for analysis. The preconcentration factors in a range of 34–135 were obtained under the optimum conditions. The calibration curves were linear (R2 ≥ 0.990) in the concentration range of 2.0–200 μg/L for AML and 5.0–200 μg/L for ATO. The limits of detection for AML and ATO were 0.5 and 2.0 μg/L, respectively. Tap water and human urine samples were successfully analyzed for the existence of AML and ATO using the proposed methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号