1.
A rapid magnetoimmunosensor for the simultaneous determination of two cardiac biomarkers, amino‐terminal pro‐B‐type natriuretic peptide (NT‐proBNP) and C‐reactive protein (CRP), in human serum is described. Specific capture antibodies were covalently immobilized onto carboxylic acid‐modified magnetic beads. The quantification of NT‐proBNP and CRP was performed by using indirect competitive and sandwich configurations, respectively, and horseradish peroxidase‐labeled tracers. The use of dual screen‐printed carbon electrodes allowed the achievement of simultaneous independent amperometric readout for each cardiac biomarker. The developed methodology showed very low limits of detection (0.47 ng mL?1). An international standard for CRP serum spiked with NT‐proBNP was analyzed to evaluate the usefulness of the magnetoimmunosensor.  相似文献   

2.
Quantitating ultra‐low concentrations of protein biomarkers is critical for early disease diagnosis and treatment. However, most current point‐of‐care (POC) assays are limited in sensitivity. Herein, we introduce an ultra‐sensitive and facile microbubbling assay for the quantification of protein biomarkers with a digital‐readout method that requires only a smartphone camera. We used machine learning to develop a smartphone application for automated image analysis to facilitate accurate and robust counting. Using this method, post‐prostatectomy surveillance of prostate specific antigen (PSA) can be achieved with a detection limit (LOD) of 2.1 fm (0.060 pg mL?1), and early pregnancy detection using βhCG can be achieved with a of 0.034 mIU mL?1 (2.84 pg mL?1). This work provides the proof‐of‐principle of the microbubbling assay with a digital readout as an ultra‐sensitive technology with minimal requirement for power and accessories, facilitating future POC applications.  相似文献   

3.
In this study, we report the development of a sensitive label‐free impedimetric sensor based on molecularly imprinted polymer (MIP) as biomimetic receptor coupled with screen‐printed electrodes (SPEs) for the detection of vascular endothelial growth factor (VEGF). Firstly, electropolymerization of o‐phenylenediamine (o‐PD) in the presence of VEGF molecule by cyclic voltammetry was performed onto graphite screen‐printed electrodes. The solvent extraction of the target was then carried out. The MIP based sensor was characterized by electrochemical techniques and scanning electron microscopy (SEM). Using optimized experimental conditions, the single‐use MIP‐based sensor showed a good analytical performance for VEGF detection from 20 to 200 pg mL?1 with limit of detection of 0.08 pg mL?1. Finally, the developed MIP‐based sensor in human serum samples was also tested.  相似文献   

4.
A strategy for a fast (ca. 20 min), specific, electrochemical immunoassay for the cardiac biomarker creatine kinase (CK) and the human cytokine interleukin 10 (IL10) has been developed in this paper. The polyaniline modified gold surface formed from electrochemical reduction of diazonium salt supplies a solid substrate to link the activated carboxylic acid groups from the antibodies, which were labelled with ferrocene. The direct electrochemistry of ferrocene allows the analysis of protein markers with good sensitivity. The creatine kinase sensor demonstrates limit of detection of 0.5 pg mL?1 in a physiological Krebs‐Henseleit solution. The anti‐IL10 antibody retained fluorescence activity after further coupling to ferrocene and covalent immobilization on to a gold electrode, showing a linear detection range for IL‐10 from 0.001 ng mL?1 to 50 ng mL?1 in PBS. We attribute the high sensitivity to the well‐controlled modified surface which results in end–on antibodies that can specifically capture the antigen with ease.  相似文献   

5.
The present work describes the first electrochemical investigation and a simple, rapid and modification‐free electroanalytical methodology for quantification of hordenine (a potent phenylethylamine alkaloid) using a boron‐doped diamond electrode. At optimized square‐wave voltammetric parameters, the observed oxidation peak current in 0.1 M HClO4 at +1.33 V (vs. Ag/AgCl) increased linearly from 5.0 to 100 μg mL?1 (3.0×10?5–6.1×10?4 M), with detection limit of 1.3 μg mL?1 (7.8×10?6 M). The applicability of the developed method was tested with the determination of hordenine in the commercial dietary supplement formulations.  相似文献   

6.
A novel electrochemical magnetoimmunosensor for fast and ultrasensitive detection of H9N2 avian influenza virus particles (H9N2 AIV) was designed based on the combination of high‐efficiency immunomagnetic separation, enzyme catalytic amplification, and the biotin–streptavidin system. The reusable, homemade magneto Au electrode (M‐AuE) was designed and used for the direct sensing. Immunocomplex‐coated magnetic beads (IMBs) were easily accumulated on the surface of the M‐AuE to obtain the catalytically reduced electrochemical signal of H2O2 after the immunoreaction. The transducer was regenerated through a simple washing procedure, which made it possible to detect all the samples on a single electrode with higher reproducibility. The magnetic‐bead‐based electrochemical immunosensor showed better analytical performance than the planar‐electrode‐based immunosensor with the same sandwich construction. Amounts as low as 10 pg mL?1 H9N2 AIV could be detected even in samples of chicken dung. This electrochemical magnetoimmunosensor not only provides a simple platform for the detection of the virus with high sensitivity, selectivity, and reproducibility but also shows great potential in the early diagnosis of diseases.  相似文献   

7.
Highly sensitive spectrofluorimetric method was developed and validated for the determination of gabapentin in pure and pharmaceutical preparations. The method was based on nucleophilic substitution reaction of gabapentin with 4‐fluoro‐7‐nitrobenzofurazan (NBD‐F) in an alkaline medium (pH 9.5) to form a highly fluorescent derivative that was measured at 521 nm after excitation at 458 nm. The factors affecting the reaction was carefully studied and optimized. The method was successfully validated for linearity, limit of detection, limit of quantification, accuracy, precision, robustness and specificity. Under the optimized conditions, linear relationship with good correlation coefficient (0.9998) was found between the relative fluorescence intensity and gabapentin concentration in the range of 10–100 ng·mL?1. The limit of detection and limit of quantification were 0.43 and 1.30 ng·mL?1, respectively. The proposed method was successfully applied to the determination of gabapentin in its pharmaceutical capsules. The results obtained by the proposed method were comparable with those obtained by the official method. Statistical comparison by t‐ and F‐ tests revealed that there was no significant difference between the results of the two methods with respect to mean values and standard deviations at the 95% confidence level.  相似文献   

8.
A sensitive electrochemical immunosensor was developed for detecting fumonisin B1 (FB1) in corn using the single‐walled carbon nanotubes/chitosan. The detection mechanism of immunosensor was based on an indirect competitive binding to a fixed amount of anti‐FB1 between free FB1 and FB1‐bovine serum albumin, which was conjugated on covalently functionalized nanotubes/chitosan laid on the glass carbon electrode. The anti‐rabbit immunoglobulin G secondary antibody labeled with alkaline phosphatase was then bound to the electrode surface through reactisubstrate α‐naphthyl phosphate, which produced electrochemical signal. Under optimized conditions, this method could detect FB1 from 0.01 to 1000 ng mL?1 with a detection limit of 2 pg mL?1. This is well below the detection limit required from European Union legislation, 2–4 mg L?1. Moreover, good recoveries were obtained for the detection of spiked corn samples and actual corn samples. As the method has good sensitivity and recovery for detecting FB1, it is a practical detection method.  相似文献   

9.
A novel and highly sensitive electrochemical immunosensor was developed for the detection of protein biomarker tumor necrosis factor‐alpha (TNF‐α) based on immobilization of TNF‐α‐antibody (anti‐TNF‐α) onto robust nanocomposite containing gold nanoparticles (AuNP), multiwalled carbon nanotubes (MWCNTs) and ionic liquid (1‐buthyl‐3‐methylimidazolium bis (trifluoromethyl sulfonyl)imide). Functionalized MWCNT‐gold nanoparticle was produced by one‐step synthesis based on the direct redox reaction. The electrochemical properties of nanocomposite were characterized by electrochemical impedance spectroscopy and cyclic voltammetry. The anti‐TNF‐α was immobilized or entrapped in the nanocomposite and used in a sandwich type complex immunoassay with anti‐TNF‐α labeled with horseradish peroxidase as secondary antibody. Under optimum conditions, the immunosensor could detect TNF‐α in a linear range from 6.0 to 100 pg mL?1 with a low detection limit of 2.0 pg mL?1. The simple fabrication method, high sensitivity, good reproducibility, stability, as well as acceptable accuracy for TNF‐α detection in human serum samples are the main advantages of this immunosensor, which might have broad applications in protein diagnostics and bioassay.  相似文献   

10.
A novel strategy is developed for the fabrication of graphene–CdS (G–CdS) nanocomposites by in situ growth of CdS nanoparticles onto simultaneously reduced graphite oxide, which is noncovalently functionalized by sodium 1‐pyrene sulfonate through strong π–π stacking interactions. Subsequently, cobalt 2,9,16,23‐tetraaminophthalocyanine (CoTAPc) is self‐assembled on the G–CdS nanocomposites through electrostatic interactions to produce phthalocyanine‐sensitized G–CdS nanocomposites. The photoactive superstructure enhances the photocurrent generation capability, and presents an efficient photoelectrochemical immunosensing platform for the ultrasensitive detection of the prostate‐specific antigen (PSA). The quantitative measurement of PSA is based on the decrease in the photocurrent intensity of the phthalocyanine‐sensitized G–CdS nanocomposites, which results from an increase in the steric hindrance due to the formation of the immunocomplex. A linear relationship between the photocurrent decrease and the PSA concentration is obtained in the wide range from 1 pg mL?1 to 5 μg mL?1 with a detection limit of 0.63 pg mL?1. The proposed sensor shows high sensitivity, stability, reproducibility, and can become a promising platform for other biomolecular detection.  相似文献   

11.
A sensitive detection of extremely toxic phenylpyrazole insecticide, ‘Fipronil’ is presented. Currently, the advancement of approaches for the detection of insecticides at low concentrations with less time is important for environmental safety assurance. Considering this fact, an effort has been made to develop an electrospun CoZnO nanofiber (NF) based label‐free electrochemical system for the detection of fipronil. The CoZnO NF were characterized using different techniques including field emission scanning electron microscopy (FE‐SEM), Energy Dispersive X‐Ray Analysis (EDX), X‐ray diffraction (XRD), Fourier‐transform infrared spectroscopy (FTIR), and Raman Spectroscopy. Based on the experimental results, the proposed platform displayed a linear response for fipronil in the attogram/mL range despite the multiple interfering agents. The sensitivity of the device was found to be 3.99 KΩ (g/ml)?1 cm?2. Limit of detection (LOD) and limit of quantification (LOQ) were calculated and found to be 112 ag mL?1 and 340 ag mL?1 respectively. Further, this proposed sensor will be implemented in the fields for the rapid and proficient detection of the real samples.  相似文献   

12.
Calmodulin (CaM) is an important intracellular calcium‐binding protein. It plays a critical role in a variety of biological and biochemical processes. In this paper, a new electrochemical immunosensing protocol for sensitive detection of CaM was developed by using gold‐silver‐graphene (AuAgGP) hybrid nanomaterials as protein immobilization matrices and gold nanorods (GNRs) as enhanced electrochemical labels. Electrode was first modified with thionine‐chitosan film to provide an immobilization support for gold‐silver‐graphene hybrid nanomaterials. The hybrid materials formed an effective matrix for binding of CaM with high density and improved the electrochemical responses as well. Gold nanorods were prepared for the fabrication of enhanced labels (HRP‐Ab2‐GNRs), which provided a large capacity for HRP‐Ab2 immobilization and a facile pathway for electron transfer. With two‐step immunoassay format, the HRP‐Ab2‐GNRs labels were introduced onto the electrode surface, and produced electrochemical responses by catalytic reaction of HRP toward enzyme substrate of hydrogen peroxide (H2O2) in the presence of thionine. The proposed immunosensor showed an excellent analytical performance for the detection of CaM ranging from 50 pg mL?1 to 200 ng mL?1 with a detection limit of 18 pg mL?1. The immunosensor has also been successfully applied to the CaM analysis in two cancer cells (HepG2 and MCF‐7) with high sensitivity, which has shown great potency for improving clinic diagnosis and treatment for cancer study.  相似文献   

13.
《Analytical letters》2012,45(1):46-55
Abstract

A Chemiluminescence Enzyme‐Linked Immuno‐Sorbent Assay (CL‐ELISA) for determination and quantification of the fungicide thiram in honeybees was developed in an indirect competitive format. The assay was optimized by determining: the optimal coating conjugate concentration and anti‐thiram antiserum dilution, the effect of the incubation time on the competitive step, the tolerance to organic solvents. The IC50 and the limit of detection (LOD) values were 60 ng mL?1 and 9 ng mL?1, respectively, similar to those of colorimetric ELISA with a calibration range of 9–15,000 ng mL?1. Cross reactivity of some related compounds such as some dithiocarbamates, a thiocarbamate, the ethylenethiourea and the tetramethylthiourea were tested. The assay was then applied to honeybees sample extracts obtained by using the liquid‐liquid extraction or the graphitized carbon‐based solid phase extraction.

The calibration curves in honeybee extracts from liquid‐liquid procedure gave an IC50 of 141 ng mL?1 and a LOD of 17 ng mL?1. In case of extracts obtained by SPE these values were 139 ng mL?1 and 15 ng mL?1, respectively. The average recovery value from honeybee extracts spiked with 75 ng mL?1 of thiram was 72% for SPE, higher than for liquid‐liquid extraction (60%). On the opposite, when the honeybees were directly spiked with 2 and 10 ppm the average recovery was higher for liquid‐liquid extraction (54%), than for SPE (31%). Finally, the assay was applied to honeybee samples collected during monitoring activities in Italy and Russia.  相似文献   

14.
Novel luminescence‐functionalized metal–organic frameworks (MOFs) with superior electrogenerated chemiluminescence (ECL) properties were synthesized based on zinc ions as the central ions and tris(4,4′‐dicarboxylicacid‐2,2′‐bipyridyl)ruthenium(II) dichloride ([Ru(dcbpy)3]2+) as the ligands. For potential applications, the synthesized MOFs were used to fabricate a “signal‐on” ECL immunosensor for the detection of N‐terminal pro‐B‐type natriuretic peptide (NT‐proBNP). As expected, enhanced ECL signals were obtained through a simple fabrication strategy because luminescence‐functionalized MOFs not only effectively increased the loading of [Ru(dcbpy)3]2+, but also served as a loading platform in the ECL immunosensor. Furthermore, the proposed ECL immunosensor had a wide linear range from 5 pg mL?1 to 25 ng mL?1 and a relatively low detection limit of 1.67 pg mL?1 (signal/noise=3). The results indicated that luminescence‐functionalized MOFs provided a novel amplification strategy in the construction of ECL immunosensors and might have great prospects for application in bioanalysis.  相似文献   

15.
α‐Synuclein (α‐SYN) is a very important neuronal protein that is associated with Parkinson’s disease. In this paper, we utilized Au‐doped TiO2 nanotube arrays to design a photoelectrochemical immunosensor for the detection of α‐SYN. The highly ordered TiO2 nanotubes were fabricated by using an electrochemical anodization technique on pure Ti foil. After that, a photoelectrochemical deposition method was exploited to modify the resulting nanotubes with Au nanoparticles, which have been demonstrated to facilitate the improvement of photocurrent responses. Moreover, the Au‐doped TiO2 nanotubes formed effective antibody immobilization arrays and immobilized primary antibodies (Ab1) with high stability and bioactivity to bind target α‐SYN. The enhanced sensitivity was obtained by using {Ab2‐Au‐GOx} bioconjugates, which featured secondary antibody (Ab2) and glucose oxidase (GOx) labels linked to Au nanoparticles for signal amplification. The GOx enzyme immobilized on the prepared immunosensor could catalyze glucose in the detection solution to produce H2O2, which acted as a sacrificial electron donor to scavenge the photogenerated holes in the valence band of TiO2 nanotubes upon irradiation of the other side of the Ti foil and led to a prompt photocurrent. The photocurrents were proportional to the α‐SYN concentrations, and the linear range of the developed immunosensor was from 50 pg mL?1 to 100 ng mL?1 with a detection limit of 34 pg mL?1. The proposed method showed high sensitivity, stability, reproducibility, and could become a promising technique for protein detection.  相似文献   

16.
Cystic echinococcosis (CE) or hydatid disease is a parasitic infection caused by Echinococcus granulosus. Early serodiagnosis and continuous monitoring of the disease is very important for medical treatment. Here, we report the detecting of both echinococcus antigen and antibody for the diagnosis of hydatid disease using square wave voltammetry (SWV)‐based immunosensors. The gold electrodes were functionalized using cysteamine/phenylene diisothiocyanate linkers and used for the immunosensors fabrication. The hydatid antigen and antibody immunosensors were constructed by the immobilization of either purified rabbit polyclonal antibody or recombinant antigen B (AgB), respectively on the functionalized gold electrodes surfaces. The detection in both cases was achieved by following the change in the SWV reduction peak current of the ferro/ferricyanide redox couple upon antibody or antigen binding. These immunosensors enabled the detection of echinococcus antigen and antibody within a concentration range of 1 pg.mL?1 to 1 μg.mL?1 with detection limits of 0.4 pg.mL?1 and 0.3 pg.mL?1, respectively. A preliminary application of the developed immunosensor was performed in spiked serum sample showing good recovery percentages ranging from 102 to 110 % for both hydatid antibody and antigen detection. This easy‐to‐use, sensitive, and low cost quantitative method holds great promise for the early diagnosis of hydatid disease and thus, better managements and treatment outcomes.  相似文献   

17.
The present work describes the individual, selective and simultaneous quantification of acetaminophen (ACP) and tramadol hydrochloride (TRA) using a modification‐free boron‐doped diamond (BDD) electrode. Cyclic voltammetric measurements revealed that the profile of the binary mixtures of ACP and TRA were manifested by two irreversible oxidation peaks at about +1.04 V (for ACP) and +1.61 V (for TRA) in Britton‐Robinson (BR) buffer pH 3.0. TRA oxidation peak was significantly improved in the presence of anionic surfactant, sodium dodecyl sulfate (SDS), while ACP signal did not change. By employing square‐wave stripping mode in BR buffer pH 3.0 containing 8×10?4 mol L?1 SDS after 30 s accumulation under open‐circuit voltage, the BDD electrode could be used for quantification of ACP and TRA simultaneously in the ranges 1.0–70 μg mL?1 (6.6×10?6–4.6×10?4 mol L?1) and 1.0–70 μg mL?1 (3.3×10?6–2.3×10?4 mol L?1), with detection limits of 0.11 μg mL?1 (7.3×10?7 mol L?1) and 0.13 μg mL?1 (4.3×10?7 mol L?1), respectively. The practical applicability of the proposed approach was tested for the individual and simultaneous quantification of ACP and/or TRA in the pharmaceutical dosage forms.  相似文献   

18.
《Electroanalysis》2006,18(9):931-934
A flow injection analysis (FIA) method for the determination of paracetamol in pharmaceutical drugs using a gold electrode modified with a self‐assembled monolayer (SAM) of 3‐mercaptopropionic acid is described. At optimized experimental conditions the dynamic concentration range was 0.15 to 15.0 mg L?1 with a detection limit of 0.2 μg mL?1 (S/N=3). The repeatability of current responses for injections of 10 μmol L?1 paracetamol was evaluated to be 3.2% (n=30) and the analytical frequency was 180 h?1. The lifetime of the modified electrode was found to be 15 days. The results obtained by using the proposed amperometric method for paracetamol determination in four different drug samples compared well with those found by spectrophotometry.  相似文献   

19.
A sensitive method is proposed for the preconcentration and quantification of the herbicide Prometrine (PROM) at a liquid‐liquid interface employing square‐wave voltammetry. The preconcentration stage was based on liquid‐liquid extraction methodology and the PROM quantification was carried out from the peak current of square‐wave voltammograms. Under the experimental conditions employed, linear calibration curves in the concentration range 1.0×10?6 M–5.0×10?5 M, with detection limit equal to 1.5×10?6 M were obtained without pretreatment of the samples. This linear range, as well as detection limit could be extended towards lower concentrations when a pretreatment procedure was employed. In this way, linearity of calibration curves between 8.0×10?8 M and 2.4×10?7 M and detection limit of 1.0×10?7 M, were observed. On the other hand, the standard addition method was also used as an alternative and an appropriated quantification technique for this system. A linear concentration range between 1.0×10?6 M and 2.7×10?5 M, with a correlation coefficient of 0.997, was obtained. This procedure has also a promising application in the separation of herbicides from other interferents, present in real samples, previous to their quantification.  相似文献   

20.
A approach was successfully employed for constructing a solid‐state electrochemiluminescence (ECL) immunosensor by layer‐by‐layer self‐assembly of multiwall carbon nanotubes (MWCNTs)‐Nafion composite film, Ru(bpy)32+/nano‐Pt aggregates (Ru‐PtNPs) and Pt nanoparticles (PtNPs). The influence of Pt nanoparticles on the ECL intensity was quantitatively evaluated by calculating the electroactive surface area of different electrodes with or without PtNPs to immobilize Ru(bpy)32+. The principle of ECL detection for target α‐fetoprotein antigen (AFP) was based on the increment of resistance after immunoreaction, which led to a decrease in ECL intensity. The linear response range was 0.01–10 ng mL?1 with the detection limit of 3.3 pg mL?1. The immunosensor exhibited advantages of simple preparation and operation, high sensitivity and good selectivity.  相似文献   