Time-of-flight (TOF) instruments have recently gained popularity in quantitative analyses. Normally, TOF mass spectrometers are used for accurate mass measurements for empirical formula verification. However, over the past decade, they have been used quantitatively as well. Because of the fast separations and narrow peaks that result from gas chromatography separations, scanning mass spectrometers are not ideal detectors. TOF mass spectrometers, however, have the ability to collect spectra at a faster rate. Two-dimensional gas chromatography has also been introduced to further resolve peaks from complex matrices. Two-dimensional gas chromatography results in a faster separation as well as narrower peaks. This paper reviews the methods currently in the literature for the quantitation of compounds using one- and two-dimensional gas chromatography and TOF mass spectrometry detection. 相似文献
2.
Calbiani F Careri M Elviri L Mangia A Zagnoni I 《Journal of mass spectrometry : JMS》2006,41(3):289-294
Liquid chromatography (LC) with high-resolution mass spectrometry (HRMS) represents a powerful technique for the identification and/or confirmation of small molecules, i.e. drugs, metabolites or contaminants, in different matrices. However, reliability of analyte identification by HRMS is being challenged by the uncertainty that affects the exact mass measurement. This parameter, characterized by accuracy and precision, is influenced by sample matrix and interferent compounds so that questions about how to develop and validate reliable LC-HRMS-based methods are being raised. Experimental approaches for studying the effects of various key factors influencing mass accuracy on low-molecular weight compounds (MW < 150 Da) when using a quadrupole-time-of-flight (QTOF) mass analyzer were described. Biogenic amines in human plasma were considered for the purpose and the effects of peak shape, ion abundance, resolution and data processing on accurate mass measurements of the analytes were evaluated. In addition, the influence of the matrix on the uncertainty associated with their identification and quantitation is discussed. A critical evaluation on the calculation of the limits of detection was carried out, considering the uncertainty associated with exact mass measurement of HRMS-based methods. The minimum concentration level of the analytes that was able to provide a statistical error lower than 5 ppm in terms of precision was 10 times higher than those calculated with S/N = 3, thus suggesting the importance of considering both components of exact mass measurement uncertainty in the evaluation of the limit of detection. 相似文献
3.
The glucuronide conjugates of ketobemidone, norketobemidone and hydroxymethoxyketobemidone were identified in human urine post-intravenous administration of Ketogan Novum. The human urine was extracted on a mixed-mode solid-phase micro-column before analysis with liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF-MS) and tandem MS (MS/MS). Accurate mass and collision-induced dissociation product ion spectra were used for identification of the glucuronide conjugates. Two different TOF mass spectrometers were used and the accurate mass measurements were performed on three separate days with each instrument. The accuracy of the mass measurements was better than 2.1 ppm for two out of three conjugates and the inter-day relative standard deviation was within +/-0.00049%. The MS/MS fragmentation patterns of the conjugates were in accordance with those of the synthetic aglycones and included peaks originating from the [M + H](+) ion of the respective aglycone. 相似文献
4.
A study of the fragmentation pathways of several classes of drugs of abuse (cannabinoids, ketamine, amphetamine and amphetamine-type stimulants (ATS), cocaine and opiates) and their related substances has been made. The knowledge of the fragmentation is highly useful for specific fragment selection or for recognition of related compounds when developing MS-based analytical methods for the trace-level determination of these compounds in complex matrices. In this work, accurate-mass spectra of selected compounds were obtained using liquid chromatography coupled to quadrupole time-of-flight mass spectrometry, performing both MS/MS and MS(E) experiments. As regards fragmentation behavior, the mass spectra of both approaches were quite similar and were useful to study the fragmentation of the drugs investigated. Accurate-mass spectra of 37 drugs of abuse and related compounds, including metabolites and deuterated analogues, were studied in this work, and structures of fragment ions were proposed. The accurate-mass data obtained allowed to confirm structures and fragmentation pathways previously proposed based on nominal mass measurements, although new insights and structure proposals were achieved in some particular cases, especially for amphetamine and ATS, 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THC-COOH) and opiates. 相似文献
5.
Over the last decade, time-of-flight (TOF) instruments have increasingly been used as quantitation tools. In addition, because of their high resolving power, they can be used for verification of empirical formulas. Historically, TOF instruments have had limited quantitation capabilities because of their narrow dynamic range. However, recent advances have improved these limitations. This review covers the rationale for using TOF for LC detection, and describes the many methods currently in the literature for the quantitation of pharmaceuticals, environmental pollutants, explosives and many phytochemicals. 相似文献
6.
Many pesticide transformation products (TPs) can reach environmental waters as a consequence of their normally having a higher polarity than their parent pesticides. This makes the development of analytical methodology for reliable identification and subsequent quantification at the sub-microgram per liter levels necessary, as required under current legislation. In this paper we report the photodegradation of several pesticides frequently detected in environmental waters from the Spanish Mediterranean region using the high-resolution and exact-mass capabilities of hybrid quadrupole time-of-flight mass spectrometry (QTOF MS) hyphenated to liquid chromatography (LC). Once the main photodegradation/hydrolysis products formed in aqueous media were identified, analytical methodology for their simultaneous quantification and reliable identification in real water samples was developed using on-line solid-phase extraction (SPE)-LC-tandem MS with a triple-quadrupole (QqQ) analyzer. The methodology was validated in both ground and surface water samples spiked at the limit of quantification (LOQ) and 10 x LOQ levels, i.e. 50 and 500 ng/l, obtaining satisfactory recoveries and precision for all compounds. Subsequent analysis of ground and surface water samples resulted in the detection of a number of TPs higher than parent pesticides. Additionally, several soil-interstitial water samples collected from the unsaturated zone were analyzed to explore the degradation/transformation of some pesticides in the field using experimental plots equipped with lisimeters. Several TPs were found in these samples, with most of them having also been detected in ground and surface water from the same area. This paper illustrates the extraordinary potential of LC-MS(/MS) with QTOF and QqQ analyzers for qualitative/structural and quantitative analysis, respectively, offering analytical chemists one of the most powerful tools available at present to investigate the presence of pesticide TPs in water. 相似文献
7.
An automated, accurate and reliable way of acquiring and processing flow injection data for exact mass measurement using a bench-top electrospray ionization time-of-flight (ESI-TOF) mass spectrometer is described. Using Visual Basic programs, individual scans were selected objectively with restrictions on ion counts per second for both the compound of interest and the mass reference peaks. The selected "good scans" were then subjected to two different data-processing schemes ("combine-then-center" and "center-then-average"), and the results were compared at various ion count limit settings. It was found that, in general, the average of mass values from individual scans is more accurate than the centroid mass value of the combined (same) scans. In order to acquire a large number of good scans in one injection (to increase the sampling size for statistically valid averaging), an on-line dilution chamber was added to slow down the typically rapid mass chromatographic peak decay in flow-injection analysis. This simple addition worked well in automation without the need for manual sample dilution. In addition, by dissolving the reference compound directly into the mobile phase, manual syringe filling can be eliminated. Twenty-seven samples were analyzed with the new acquisition and process routines in positive electrospray ionization mode. For the best method found, the percentage of samples with RMS error less than 5 ppm was 100% with repetitive injection data (6 injections per sample), and 95% with single injection data. Afterwards, 31 other test samples were run (with MW ranging from 310 to 3493 Da, 21 samples in ESI+ and 10 in ESI- mode) and processed with similar parameters and 100% of them were mass-calculated to RMS error less than 5 ppm also. 相似文献
8.
Matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) time-of-flight mass spectrometry (TOFMS) play an essential role in the analysis of biological molecules, not only peptides and proteins, but also DNA and RNA. Tandem mass spectrometry used for sequence analysis has been a major focus of technological developments in mass spectrometry, but accurate mass measurements by high-resolution TOFMS are equally important. This paper describes the role that high mass measurement accuracy can play in DNA composition assignment and discusses the influence of several parameters on mass measurement accuracy in both MALDI and ESI mass spectra. Five oligonucleotides (5-13mers) were used to test the resolving power and mass measurement accuracy obtained with MALDI and ESI instruments with reflectron TOF mass analyzers. The results from the experimental studies and additional theoretical calculations provide a basis to predict the practical utility of high-resolution TOFMS for the analysis of larger oligonucleotides. 相似文献
9.
Joonas Nurmi Jukka Pellinen Anna‐Lea Rantalainen 《Journal of mass spectrometry : JMS》2012,47(3):303-312
Emerging contaminants from wastewater effluent samples were analysed, using posttarget and nontarget analysis techniques. The samples were analysed with an ultra performance liquid chromatograph‐time‐of‐flight mass spectrometer (UPLC‐TOF‐MS), and the resulting data were processed with commercial deconvolution software. The method works well for posttarget analysis with prior information about the retention times of the compounds of interest. With positive polarity, 63 of 66 compounds and with negative polarity, 18 of 20 compounds were correctly identified in a spiked sample, while two compounds of a total of 88 fell out of the mass range. Furthermore, a four‐stage process for identification was developed for the posttarget analysis lacking the retention time data. In the process, the number of candidate compounds was reduced by using the accurate mass of selected compounds in two steps (stages 1 and 2), structure–property relationships (stage 3) and isotope patterns of the analytes (stage 4). The process developed was validated by analysing wastewater samples spiked with 88 compounds. This procedure can be used to gain a preliminary indication of the presence of certain analytes in the samples. Nontarget analysis was tested by applying a theoretical mass spectra library for a wastewater sample spiked with six pharmaceuticals. The results showed a high number of false identifications. In addition, manual processing of the data was considered laborious and ineffective. Finally, the posttarget analysis was applied to a real wastewater sample. The analysis revealed the presence of six compounds that were afterwards confirmed with standard compounds as being correct. Three psycholeptics (nordiazepam, oxazepam and temazepam) could be tentatively identified, using the identification process developed. Posttarget analysis with UPLC‐TOF‐MS proved to be a promising method for analysing wastewater samples, while we concluded that the software for nontarget analysis will need improvement before it can be used in environmental analytical work with LC‐TOF‐MS systems. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
10.
This paper gives an overview of the potentials of liquid chromatography-hybrid quadrupole time-of-flight mass spectrometry (LC-QqTOF) in the environmental analysis. Examples of applications of QqTOF instruments for target analysis of pharmaceuticals and pesticides are presented and discussed, as well as applications aimed on the identification of unknown compounds present in environmental waters or on the elucidation of structures of biodegradation and photodegradation products. Specific issues such as uncertainty of mass measurement and quantitative performances are discussed in details. 相似文献
11.
《Journal of mass spectrometry : JMS》2017,52(6):378-396
This study reports an applicable analytical strategy of comprehensive identification and structure characterization of target components from Gelsemium elegans by using high‐performance liquid chromatography quadrupole time‐of‐flight mass spectrometry (LC‐QqTOF MS) based on the use of accurate mass databases combined with MS/MS spectra. The databases created included accurate masses and elemental compositions of 204 components from Gelsemium and their structural data. The accurate MS and MS/MS spectra were acquired through data‐dependent auto MS/MS mode followed by an extraction of the potential compounds from the LC‐QqTOF MS raw data of the sample. The same was matched using the databases to search for targeted components in the sample. The structures for detected components were tentatively characterized by manually interpreting the accurate MS/MS spectra for the first time. A total of 57 components have been successfully detected and structurally characterized from the crude extracts of G. elegans , but has failed to differentiate some isomers. This analytical strategy is generic and efficient, avoids isolation and purification procedures, enables a comprehensive structure characterization of target components of Gelsemium and would be widely applicable for complicated mixtures that are derived from Gelsemium preparations. Copyright © 2017 John Wiley & Sons, Ltd. 相似文献
12.
Mariosimone Zoccali Barbara Giocastro Peter Q. Tranchida Luigi Mondello 《Journal of separation science》2019,42(3):691-697
The present research is based on the use of a recently developed comprehensive two‐dimensional gas chromatography thermal modulator, which is defined as solid‐state modulator. The transfer device was installed on top of a single gas chromatography oven, while benchtop low‐resolution time‐of‐flight mass spectrometry was used to monitor the compounds exiting the second analytical column. The solid‐state modulator was first described by Luong et al. in 2016, and it is a moving modulator that does not require heating and cooling gases to generate comprehensive two‐dimensional gas chromatography data. The accumulation and remobilization steps occur on a trapping capillary, this being subjected to thermoelectric cooling and micathermic heating. In this study, the effects of the gas linear velocity on the modulation performance were evaluated by using two different uncoated trapping capillaries, viz., 0.8 m × 0.25 mm id and 0.8 m × 0.20 mm id. Solid‐state modulator applications were carried out on a standard solution containing n‐alkanes (C9, C10, C12), and on a sample of diesel fuel. The results indicated that the type of trapping capillary and gas velocity have a profound effect on modulation efficiency. 相似文献
13.
Portolés T Pitarch E López FJ Sancho JV Hernández F 《Journal of mass spectrometry : JMS》2007,42(9):1175-1185
The potential of gas chromatography coupled to time-of-flight mass spectrometry (GC-TOF MS) for the screening of organic pollutants in water was explored. After a conventional SPE step with C(18) cartridges, the comparison of spectra with available libraries together with an evaluation of the mass accuracy was the first approach used for the screening and confirmation of target analytes. However, at low analyte concentrations (i.e. below 0.1 microg/l), this procedure was not feasible and the use of the application manager TargetLynx was evaluated. This application allows the selection of up to five representative ions per analyte, measured with high mass accuracy, and their intensity ratio evaluation. Ion selection, extraction mass window and concentration levels were found to be the critical parameters. The reference compound used as 'lock mass' was also found to affect to the quality of information obtained in some particular cases.Full spectral acquisition data generated by the TOF MS analyzer allowed investigation of the presence of several analytes in samples in a post-target style, without the need of reanalyze the water samples.Finally, a methodical approach was established for the reliable screening and confirmation of organic pollutants (PAHs, pesticides, octyl/nonyl phenols) in real-world samples, which led to satisfactory results of approximately 0.1 microg/l. 相似文献
14.
Greaves J 《Journal of mass spectrometry : JMS》2002,37(8):777-785
Open access mass spectrometry now provides the opportunity to move this spectroscopic method to the beginning of the analytical chain, a place formerly the exclusive province of NMR and TLC. To date this transition has been occurring in industrial settings but there has been less change in the academic environment. This paper provides one blueprint for setting up such a facility, primarily in support of organic synthesis but also for the use of biological scientists. The open access format used at UCI utilizes four instruments: an ESI-TOFMS system used in the flow injection mode, two GC/MS systems (one in EI and one in CI) and a MALDI-TOFMS system. The first three instruments have autosamplers and open access software whereas the MALDI system has a fully automated plate handling interface. This level of automation allows access to the instruments by a user community of more than 100 users, day or night. The decisions made in setting up these instruments were based on a 'keep it simple' philosophy, given the fact that the primary type of data of interest is the molecular mass of the analyte and that data are required for a very wide range of structures. 相似文献
15.
Flix Hernndez Tania Portols Elena Pitarch Francisco J. Lpez 《Journal of mass spectrometry : JMS》2009,44(1):1-11
The potential of gas chromatography‐time‐of‐flight mass spectrometry (GC‐TOF MS) for screening anthropogenic organic contaminants in human breast adipose tissues has been investigated. Initially a target screening was performed for a list of 125 compounds which included persistent halogen pollutants [organochlorine (OC) pesticides, polychlorinated biphenylss (PCBs), polybrominated diphenyl ethers (PBDEs)], polyaromatic hydrocarbons (PAHs), alkylphenols, and a notable number of pesticides from the different fungicide, herbicide and insecticide families. Searching for target pollutants was done by evaluating the presence of up to five representative ions for every analyte, all measured at accurate mass (20‐mDa mass window). The experimental ion abundance ratios were then compared to those of reference standards for confirmation. Sample treatment consisted of an extraction with hexane and subsequent normal‐phase (NP) High performance liquid chromatography (HPLC) or SPE cleanup. The fat‐free LC fractions were then investigated by GC‐TOF MS. Full‐spectral acquisition and accurate mass data generated by GC‐TOF MS also allowed the investigation of nontarget compounds using appropriate processing software to manage MS data. Identification was initially based on library fit using commercial nominal mass libraries. This was followed by comparing the experimental accurate masses of the most relevant ions with the theoretical exact masses with calculations made using the elemental composition calculator included in the software. The application of both target and nontarget approaches to around 40 real samples allowed the detection and confirmation of several target pollutants including p,p′‐DDE, hexachlorobenzene (HCB), and some polychlorinated biphenyls (PCBs) and polyaromatic hydrocarbons (PAHs). Several nontarget compounds that could be considered anthropogenic pollutants were also detected. These included 3,5‐di‐tert‐butyl‐4‐hydroxy‐toluene (BHT) and its metabolite 3,5‐di‐tert‐butyl‐4‐hydroxybenzaldehyde (BHT‐CHO), dibenzylamine, N‐butyl benzenesulfonamide (N‐BBSA), some naphthalene‐related compounds and several PCBs isomers not included in the target list. As some of the compounds detected are xenoestrogens, the methodology developed in this paper could be useful in human breast cancer research. Copyright © 2008 John Wiley & Sons, Ltd. 相似文献
16.
T. Portolés J. V. Sancho F. Hernández A. Newton P. Hancock 《Journal of mass spectrometry : JMS》2010,45(8):926-936
The potential applications of a new atmospheric pressure source for GC‐MS analysis have been investigated in this work. A list of around 100 GC‐amenable pesticides, which includes organochlorine, organophosphorus and organonitrogenated compounds, has been used to evaluate their behavior in the new source. Favoring the major formation of the molecular ion in the source has been the main goal due to the wide‐scope screening possibilities that this fact brings in comparison with the traditional, highly fragmented electron ionization spectra. Thus, the addition of water as modifier has been tested as a way to promote the generation of protonated molecules. Pesticides investigated have been classified into six groups according to their ionization/fragmentation behavior. Four of them are characterized by the abundant formation of the protonated molecule in the atmospheric pressure source, mostly being the base peak of the spectrum. These results show that wide‐scope screening could be easily performed with this source by investigating the presence of the protonated molecule ion, MH+. The developed procedure has been applied to pesticide screening in different food samples (nectarine, orange and spinach) and it has allowed the presence of several pesticides to be confirmed such as chlorpyriphos ethyl, deltamethrin and endosulfan sulfate. The availability of a quadrupole time‐of‐flight instrument made it feasible to perform additional MS/MS experiments for both standards and samples to go further in the confirmation of the identity of the detected compounds. Results shown in this paper have been obtained using a prototype source which exhibits promising features that could be applied to other analytical problems apart from those illustrated in this work. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
17.
T. Rodríguez‐Cabo M. Paganini I. Carpinteiro L. Fontenla I. Rodríguez M. C. Pietrogrande R. Cela 《Journal of mass spectrometry : JMS》2013,48(2):216-226
Liquid chromatography (LC) combined with tandem mass spectrometry (MS/MS), based on the use of a hybrid quadrupole‐time‐of‐flight mass analyzer, was used to investigate the reactivity of nine fungicides in free chlorine‐containing water samples. Three of the selected compounds (fenhexamid, FEN; pyrimethanil, PYR; and cyprodinil, CYP) displayed a poor stability in presence of moderate chlorine levels; thus, the effects of different parameters on their half‐lives (t1/2) were evaluated. Sample pH, bromide traces, and the water matrix affected their relative stabilities. Despite such variations, the three fungicides are degraded at significant rates not only in ultrapure, but also in surface water spiked with chlorine levels up to 2 µg ml?1, and when mixed with chlorinated tap water, generating several transformation products (TPs). The time‐course of precursor species and their TPs was followed in the LC‐MS mode, using the information contained in accurate, full scan mass spectra (MS) to propose the empirical formulae of TPs. Thereafter, their ion product scan (MS/MS) spectra were considered to set their chemical structures; allowing, in some cases, to distinguish between isomeric TPs. The reaction pathway of FEN, the less stable fungicide, involved just an electrophilic substitution of hydrogen per chlorine, or bromine, and cleavage of the molecule to render an amide. PYR and CYP shared common reaction routes consisting of halogenation, hydroxylation, and condensation processes leading to complex mixtures of TPs, which were relatively stable to further transformations. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
18.
《Journal of mass spectrometry : JMS》2017,52(2):69-77
The identification and further quantification of 2‐chloro‐triarylimidazole (o‐Cl‐TAI) and its dimer (o‐DCl‐HABI) in sludge from a sewage treatment plant (STP) is reported for the first time. Liquid chromatography (LC) quadrupole time‐of‐flight (QTOF) mass spectrometry (MS) was used as analytical technique during screening and determination steps. Pollutants were identified following a post‐run search strategy, applying the chlorine mass filter, and characterized by their accurate MS and product ion scan spectra. Finally, their identities were confirmed with authentic standards. The species (o‐Cl‐TAI) has been rated as potentially genotoxic and carcinogenic for mice and rats. Effects of sample preparation in the stability and the extraction efficiency of both compounds are discussed. Under final conditions, they were extracted from freeze‐dried samples (0.5 g of sludge or biosolids dispersed with 2 g of C18 and packed into a polypropylene syringe) with 20 ml of methanol, which also flowed through a clean‐up layer of Florisil and PSA sorbents (0.5 g each). This method attained quantitative extraction yields and limits of quantification between 4 and 10 ng/g. The pollutants o‐Cl‐TAI and o‐DCl‐HABI were ubiquitous in sludge and biosolids obtained in consecutive years from the investigated STP. Their concentrations varied from 0.02 to more than 13 μg/g (freeze‐dried sample). Copyright © 2016 John Wiley & Sons, Ltd. 相似文献
19.
A liquid chromatography coupled with electrospray ionization time-of-flight mass spectrometry (LC-ESI-TOF-MS) method has been developed to evaluate the quality of three formulas of compound Danshen preparations (CDPs), through a simultaneous determination of 22 marker constituents (nine major phenolic acids, eight major saponins and five major diterpenoids). Optimum separations were obtained with a Zorbax C(18) column, using a gradient elution with 0.1% aqueous formic acid and acetonitrile. Limits of detection and quantification were in ranges of 1.58-10.10 and 4.85-28.56 ng/mL. All calibration curves showed good linear regression (r(2 ) > 0.9900) within the test range, and the recoveries were between 78.4 and 103.1% for all analytes. The assay was successfully utilized to analyze the 22 marker components in 26 samples. The overall results demonstrated that this method is sensitive, accurate and reliable for the quality control of CDPs. 相似文献
20.
《Journal of separation science》2018,41(1):163-179
Gas chromatography coupled to high‐resolution mass spectrometry is a powerful analytical method that combines excellent separation power of gas chromatography with improved identification based on an accurate mass measurement. These features designate gas chromatography with high‐resolution mass spectrometry as the first choice for identification and structure elucidation of unknown volatile and semi‐volatile organic compounds. Gas chromatography with high‐resolution mass spectrometry quantitative analyses was previously focused on the determination of dioxins and related compounds using magnetic sector type analyzers, a standing requirement of many international standards. The introduction of a quadrupole high‐resolution time‐of‐flight mass analyzer broadened interest in this method and novel applications were developed, especially for multi‐target screening purposes. This review is focused on the development and the most interesting applications of gas chromatography coupled to high‐resolution mass spectrometry towards analysis of environmental matrices, biological fluids, and food safety since 2010. The main attention is paid to various approaches and applications of gas chromatography coupled to high‐resolution mass spectrometry for non‐target screening to identify contaminants and to characterize the chemical composition of environmental, food, and biological samples. The most interesting quantitative applications, where a significant contribution of gas chromatography with high‐resolution mass spectrometry over the currently used methods is expected, will be discussed as well. 相似文献