首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
We describe the development and testing of a setup that allows for DEP field‐flow fractionation (DEP‐FFF) of irreversibly electroporated, reversibly electroporated, and nonelectroporated cells based on their different polarizabilities. We first optimized the channel and electrode dimensions, flow rate, and electric field parameters for efficient DEP‐FFF separation of moderately heat‐treated CHO cells (50°C for 15 min) from untreated ones, with the former used as a uniform and stable model of electroporated cells. We then used CHO cells exposed to electric field pulses with amplitudes from 1200 to 2800 V/cm, yielding six groups containing various fractions of nonporated, reversibly porated, and irreversibly porated cells, testing their fractionation in the chamber. DEP‐FFF at 65 kHz resulted in distinctive flow rates for nonporated and each of the porated cell groups. At lower frequencies, the efficiency of fractionation deteriorated, while at higher frequencies the separation of individual elution profiles was further improved, but at the cost of cell flow rate slowdown in all the cell groups, implying undesired transition from negative into positive DEP, where the cells are pulled toward the electrodes. Our results demonstrate that fractionation of irreversibly electroporated, reversibly electroporated, and nonelectroporated cells is feasible at a properly selected frequency.  相似文献   

3.
Microfluidic device embedding electrodes realizes cell manipulation with the help of dielectrophoresis. Cell manipulation is an important technology for cell sorting and cell population purification. Till now, the theory of dielectrophoresis has been greatly developed. Microfluidic devices with various arrangements of electrodes have been reported from the beginning of the single non‐uniform electric field to the later multiple physical fields. This paper reviews the research status of microfluidic device embedding electrodes for cell manipulation based on dielectrophoresis. Firstly, the working principle of dielectrophoresis is explained. Next, cell manipulation approaches based on dielectrophoresis are introduced. Then, different types of electrode arrangements in the microfluidic device for cell manipulation are discussed, including planar, multilayered and microarray dot electrodes. Finally, the future development trend of the dielectrophoresis with the help of microfluidic devices is prospected. With the rapid development of microfluidic technology, in the near future, high precision, high throughput, high efficiency, multifunctional, portable, economical and practical microfluidic dielectrophoresis will be widely used in the fields of biology, medicine, agriculture and so on.  相似文献   

4.
Insulator‐based dielectrophoresis (iDEP) is a well‐known technique that harnesses electric fields for separating, moving, and trapping biological particle samples. Recent work has shown that utilizing DC‐biased AC electric fields can enhance the performance of iDEP devices. In this study, an iDEP device with 3D varying insulating structures analyzed in combination with DC biased AC fields is presented for the first time. Using our unique reactive ion etch lag, the mold for the 3D microfluidic chip is created with a photolithographic mask. The 3D iDEP devices, whose largest dimensions are 1 cm long, 0.18 cm wide, and 90 μm deep are then rapidly fabricated by curing a PDMS polymer in the glass mold. The 3D nature of the insulating microstructures allows for high trapping efficiency at potentials as low as 200 Vpp. In this work, separation of Escherichia coli from 1 μm beads and selective trapping of live Staphylococcus aureus cells from dead S. aureus cells is demonstrated. This is the first reported use of DC‐biased AC fields to selectively trap bacteria in 3D iDEP microfluidic device and to efficiently separate particles where selectivity of DC iDEP is limited.  相似文献   

5.
Cell rotation is widely required in various fields as an important technique for single cell manipulation. Usually, the electro‐rotational manipulation of single cells by dielectrophoresis technologies requires at least three electrodes to generate rotating electric fields which induce cells to rotate. Here, we present a novel microfluidic chip capable of rotating single cell using only two planar electrodes by taking polarized cells as the extra electrodes with phase‐shifted signal. To demonstrate this idea, we configured two parallel and planar electrodes as basic dielectrophoresis elements and placed trenches above these electrodes to attract cells, which were in turn polarized to be electrodes. Through simulation, we confirmed the functional structure of the device works well to generate proper rotating electric fields for cell rotation. Through experiment, we successfully demonstrated controlled electro‐rotation of HeLa and HepaRG cells. The novel electro‐rotation mechanism not only simplifies the micro‐device structure but also reduces the complexity of single cell rotation operation which will be a benefit to the potential users.  相似文献   

6.
This paper demonstrates the utilization of 3D semispherical shaped microelectrodes for dielectrophoretic manipulation of yeast cells. The semispherical microelectrodes are capable of producing strong electric field gradients, and in turn dielectrophoretic forces across a large area of channel cross‐section. The semispherical shape of microelectrodes avoids the formation of undesired sharp electric fields along the structure and also minimizes the disturbance of the streamlines of nearby passing fluid. The advantage of semispherical microelectrodes over the planar microelectrodes is demonstrated in a series of numerical simulations and proof‐of‐concept experiments aimed toward immobilization of viable yeast cells.  相似文献   

7.
Monocyte heterogeneity and its prevalence are revealed as indicator of several human diseases ranking from cardiovascular diseases to rheumatoid arthritis, chronic kidney diseases, autoimmune multiple sclerosis, and stroke injuries. When monocytes and macrophages are characterized and isolated with preserved genetic, phenotypic and functional properties, they can be used as label‐free biomarkers for precise diagnostics and treatment of various diseases. Here, the dielectrophoretic responses of the monocytes and macrophages were examined. We present 3D carbon‐electrode dielectrophoresis (carbon‐DEP) as a separation tool for U937 monocytes and U937 monocyte‐differentiated macrophages. The carbon‐electrodes advanced the usability and throughput of DEP separation, presented wider electrochemical stability. Using the 3D carbon‐DEP chip, we first identified the selective positive and negative DEP responses and specific crossover frequencies of monocytes and macrophages as their signatures for separation. The crossover frequency of monocytes and macrophages was 17 and 30 kHz, respectively. Next, we separated monocyte and macrophage subpopulations using their specific dielectrophoretic responses. Afterward, we used a fluorescence‐activated cell sorter to confirm our results. Finally, we enriched 70% of monocyte cells from the mixed cell population, in other words, concentration of monocyte cells to macrophage cells was five times increased, using the 30‐kHz, 10‐Vpp electric field and 1 μL/min flow rate.  相似文献   

8.
In this paper, we successfully separated malignant human breast cancer epithelial cells (MCF 7) from healthy breast cells (MCF 10A) and analyzed the main parameters that influence the separation efficiency with an advanced dielectrophoresis (DEP)-activated cell sorter (DACS). Using the efficient DACS, the malignant cancer cells (MCF 7) were isolated successfully by noninvasive methods from normal cells with similar cell size distributions (MCF 10A), depending on differences between their material properties such as conductivity and permittivity, because our system was able to discern the subtle differences in the properties by generating continuously changed electrical field gradients. In order to evaluate the separation performance without considering size variations, the cells collected from each outlet were divided into size-dependent groups and counted statistically. Following that, the quantitative relative ratio of numbers between MCF 7 and MCF 10A cells in each size-dependent group separated by the DEP were compared according to applied frequencies in the range 48, 51, and 53 MHz with an applied amplitude of 8 Vpp. Finally, under the applied voltage of 48 MHz–8 Vpp and a flow rate of 290 μm/s, MCF 7 and MCF 10A cells were separated with a maximum efficiency of 86.67% and 98.73% respectively. Therefore, our suggested system shows it can be used for detection and separation of cancerous epithelial cells from noncancerous cells in clinical applications.  相似文献   

9.
Review of cell and particle trapping in microfluidic systems   总被引:2,自引:0,他引:2  
The ability to obtain ideal conditions for well-defined chemical microenvironments and controlled temporal chemical and/or thermal variations holds promise of high-resolution cell response studies, cell-cell interactions or e.g. proliferation conditions for stem cells. It is a major motivation for the rapid increase of lab-on-a-chip based cell biology research. In view of this, new chip-integrated technologies are at an increasing rate being presented to the research community as potential tools to offer spatial control and manipulation of cells in microfluidic systems. This is becoming a key area of interest in the emerging lab-on-a-chip based cell biology research field. This review focuses on the different technical approaches presented to enable trapping of particles and cells in microfluidic system.  相似文献   

10.
We report on a facile method to stabilize colloidal self‐assembled (CSA) nanoparticles packed in microchannels for high speed size‐based separation of proteins. Silica nanoparticles, self‐assembled in a network of microfluidic channels, were stabilized with a methacrylate polymer prepared in situ through photopolymerization. The entrapment conditions were investigated to minimize the effect of the polymer matrix on the structure of the packing and the separation properties of the CSA beds. SEM shows that the methacrylate matrix links the nanoparticles at specific sphere–sphere contact points, improving the stability of the CSA structure at high electric fields (up to at least 1800 V/cm), allowing fast and efficient separation. The %RSD of the protein migration times varied between 0.3 and 0.5% (n = 4, in 1 day) and <0.83% over a period of 7 days (n = 28 runs) in a single device, at high field strength. The overall %RSD of protein migration times from chip‐to‐chip across a single fabrication run was 4.3% (n = 3) and between fabrication runs was 11% (n = 35), with 87% fabrication yield, demonstrating reproducible packing and entrapment behavior. The optimized entrapped CSA beds demonstrated better separation performance (plate height, H ~ 200 nm) than similarly prepared on‐chip CSA beds without the polymer entrapment. Polymer‐entrapped CSA beds also exhibited superior protein resolving power: the minimum resolvable molecular weight difference of proteins in the polymer‐entrapped CSA bed is 0.6 kDa versus ~9 kDa for the native silica CSA bed (i.e. without polymer entrapment).  相似文献   

11.
An oligoamide‐ended poly(ethylene glycol) (PEG) with a PEG weight‐average molecular weight of 5000 (PEG‐5000‐oligoamide), with 3,5‐bis‐[2‐(5‐acetylamino‐2‐isobutoxy‐benzoylamino)‐acetylamino]‐benzoyl as the oligoamide, was synthesized. PEG‐5000‐oligoamide aggregated in chloroform or toluene via hydrogen‐bonding interactions among the oligoamide strands as a core and PEG, which was soluble in the solvents, as a shell. When a chloroform solution of PEG‐5000‐oligoamide at a concentration of approximately 0.06 g/L was cast onto a silicon wafer or a mica plate, rapid solvent evaporation induced its self reassembly as nanofibers. © 2005 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 43: 1119–1128, 2005  相似文献   

12.
Achieving real‐time detection of environmental pathogens such as viruses and bacterial spores requires detectors with both rapid action and a suitable detection threshold. However, most biosensors have detection limits of an order of magnitude or more above the potential infection threshold, limiting their usefulness. This can be improved through the use of automated sample preparation techniques such as preconcentration. In this paper, we describe the use of AC electroosmosis to concentrate nanoparticles from a continuous flow. Electrodes at an optimized angle across a flow cell, and energized by a 1 kHz signal, were used to push nanoparticles to one side of a flow cell, and to extract the resulting stream with a high particle concentration from that side of the flow cell. A simple model of the behavior of particles in the flow cell has been developed, which shows good agreement with experimental results. The method indicates potential for higher concentration factors through cascading devices.  相似文献   

13.
Supramolecular assembly holds great potential in many technological applications. Such structures, however, tend to destabilize in dynamic environments due to weak interactions between their constituent entities. We report on a highly modular and biofriendly chemistry for the stabilization of supramolecular microgel aggregates. Upon irradiation, these structures undergo intermolecular cross‐linking, providing an efficient mechanism for stabilization.  相似文献   

14.
《Electroanalysis》2004,16(22):1853-1862
As modern electronics rapidly approach the ultimate level of integration (typically thought to be at the nanoscale level), the fascinating world of biomolecules provides new opportunities and directions for further miniaturization. In this work we review our results in the field of biomolecular electronics, starting from the fabrication of nanojunctions up to the implementation of hybrid devices.  相似文献   

15.
Nanocomposite films [Ag/(PAH‐PSS)nPAH]m were fabricated on a silicon substrate using a time‐ and cost‐efficient spin‐assisted layer‐by‐layer (SA‐LbL) self‐assembly technique. A virtually monolayer‐like layer of self‐assembled silver nanoparticles was formed when deposition time increased to 30 min. It was found that polymer multilayers could effectively decrease the resistivity of silver nanoparticle monolayer, which was far higher than that of bulk silver metal; however, the resistivity of Ag/(PAH‐PSS)nPAH multilayer films increased along with the increasing of the number of polymer bilayers. XPS investigations showed that silver nanoparticles were partially oxidized, which might be the major cause of the high resistivity of silver nanoparticle monolayer. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

16.
We present the development of a dynamic model for predicting the trajectory of microparticles in microfluidic devices, employing dielectrophoresis, for Hyperlayer field‐flow fractionation. The electrode configuration is such that multiple finite‐sized electrodes are located on the top and bottom walls of the microchannel; the electrodes on the walls are aligned with each other. The electric potential inside the microchannel is described using the Laplace equation while the microparticles' trajectory is described using equations based on Newton's second law. All equations are solved using finite difference method. The equations of motion account for forces including inertia, buoyancy, drag, gravity, virtual mass, and dielectrophoresis. The model is used for parametric study; the geometric parameters analyzed include microparticle radius, microchannel depth, and electrode/spacing lengths while volumetric flow rate and actuation voltage are the two operating parameters considered in the study. The trajectory of microparticles is composed of transient and steady state phases; the trajectory is influenced by all parameters. Microparticle radius and volumetric flow rate, above the threshold, do not influence the steady state levitation height; microparticle levitation is not possible below the threshold of the volumetric flow rate. Microchannel depth, electrode/spacing lengths, and actuation voltage influence the steady‐state levitation height.  相似文献   

17.
《Electrophoresis》2018,39(4):590-596
The translational motion of small particles in an electrokinetic fluid flow through a constriction can be enhanced by an increase of the applied electric potential. Beyond a critical potential, however, the negative dielectrophoresis (DEP) can overpower other forces to prevent particles that are even smaller than the constriction from passing through the constriction. This DEP choking phenomenon was studied previously for rigid particles. Here, the DEP choking phenomenon is revisited for deformable particles, which are ubiquitous in many biomedical applications. Particle deformability is measured by the particle shear modulus, and the choking conditions are reported through a parametric study that includes the channel geometry, external electric potential, and particle zeta potential. The study was carried out using a numerical model based on an arbitrary Lagrangian‐Eulerican (ALE) finite‐element method.  相似文献   

18.
Electroporation is a powerful tool for inactivating cells and transfecting biological cells and has applications in biology, genetic engineering, medicine, environment, and many others. We report a new continuous flow device embedded with insulating micropillars to achieve better performance of cell inactivation. The use of micropillars creates multiple electroporation zones with enhanced local electric field strengths. Using a model solution of Saccharomyces cerevisiae, we examined the inactivation performance of the device under various applied electric voltages and flow rates. Results from the numerical simulations and experiments showed that even with an induced transmembrane potential of 0.58 V, close to 63% of cell inactivation was achieved at a flow rate of 2.5 mL/h. This was higher than the 24% cell inactivation observed for a reference device without micropillars that was subjected to the same conditions.  相似文献   

19.
《Electrophoresis》2017,38(16):1988-1995
Inherent electrical properties of cells can be beneficial to characterize different cell lines and their response to experimental drugs. This paper presents a novel method to characterize the response of breast cancer cells to drug stimuli through use of off‐chip passivated‐electrode insulator‐based dielectrophoresis (OπDEP) and the application of AC electric fields. This work is the first to demonstrate the ability of OπDEP to differentiate between two closely related breast cancer cell lines, LCC1 and LCC9 while assessing their drug sensitivity to an experimental anti‐cancer agent, Obatoclax. Although both cell lines are derivatives of estrogen‐responsive MCF‐7 breast cancer cells, growth of LCC1 is estrogen independent and anti‐estrogen responsive, while LCC9 is both estrogen‐independent and anti‐estrogen resistant. Under the same operating conditions, LCC1 and LCC9 had different DEP profiles. LCC1 cells had a trapping onset (crossover) frequency of 700 kHz and trapping efficiencies between 30–40%, while LCC9 cells had a lower crossover frequency (100 kHz) and showed higher trapping efficiencies of 40–60%. When exposed to the Obatoclax, both cell lines exhibited dose‐dependent shifts in DEP crossover frequency and trapping efficiency. Here, DEP results supplemented with cell morphology and proliferation assays help us to understand the response of these breast cancer cells to Obatoclax.  相似文献   

20.
We present an approach for the accumulation and filtering of nano- and microparticles in microfluidic devices that is based on the generation of electric traveling waves in the radio-frequency range. Upon application of the electric field via a microelectrode array, complex particle trajectories and particle accumulation are observed in well-defined regions in a microchannel. Through the quantitative mapping of the 3-D flow pattern using two-focus fluorescence cross-correlation spectroscopy, two vortices could be identified as one of the sources of the force field that induces the formation of particle clouds. Dielectrophoretic forces that directly act on the particles are the second source of the force field. A thorough 2-D finite element analysis identifies the electric traveling wave mechanism as the cause for the unexpected flow behavior observed. Based on these findings, strategies are discussed, first, for avoiding the vortices to optimize electrohydrodynamic micropumps and, secondly, for utilizing the vortices in the development of microdevices for efficient particle accumulation, separation, and filtering. Such devices may find numerous biomedical applications when highly diluted nano- and microsuspensions have to be processed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号