首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Bhattacharya S  Chao TC  Ros A 《Electrophoresis》2011,32(18):2550-2558
Trapping of individual cells at specific locations in a microfluidic lab-on-a-chip platform is essential for single cell studies, especially those requiring individual stimulation followed by downstream analysis. To this aim, we have designed microdevices based on direct current (DC) insulator-based dielectrophoresis (iDEP) acting as individual single cell traps. We present both the design of a negative iDEP trap and a positive iDEP trap using insulating posts integrated at microchannel intersections. We obtained electric field distributions via numerical simulations adapted to the intersection and trap geometry with which we predict single particle pathlines. With polystyrene particles of 10?μm diameter, we demonstrated an effective design for a single particle trap in the case of negative dielectrophoresis. The onset trapping voltage shows an inverse relation to the buffer conductivity, thus indicating the influence of electrokinetic effects on the trapping behavior. Additionally, we demonstrated the proof-of-principle of single MCF-7 breast cancer cell trapping in a positive iDEP trap. Our single particle trapping experiments were further in very good agreement with numerical simulations. To ensure that no significant damage occurred to the cells during the experiment, we further optimized medium conditions to ensure viability of the cells for at least 1?h, more than sufficient for microfluidic trapping experiments. Our results thus indicated the successful design of DC iDEP traps, which can easily be integrated into a variety of microchip operations for single cell analysis.  相似文献   

2.
In a microbiological device, cell or particle manipulation and characterization require the use of electric field on different electrodes in several configurations and shapes. To efficiently design microelectrodes within a microfluidic channel for dielectrophoresis focusing, manipulation and characterization of cells, the designer will seek the exact distribution of the electric potential, electric field and hence dielectrophoresis force exerted on the cell within the microdevice. In this paper we describe the approach attaining the analytical solution of the dielectrophoretic force expression within a microchannel with parallel facing same size electrodes present on the two faces of channel substrates, with opposite voltages on the pair electrodes. Simple Fourier series mathematical expressions are derived for electric potential, electric field and dielectric force between two distant finite‐size electrodes. Excellent agreement is found by comparing the analytical results calculated using MATLAB? with numerical ones obtained by Comsol. This analytical result can help the designer to perform simple design parametric analysis. Bio‐microdevices are also designed and fabricated to illustrate the theoretical solution results with the experimental data. Experiments with red blood cells show the dielectrophoretic force contour plots of the analytical data matched to the experimental results.  相似文献   

3.
《Electrophoresis》2017,38(16):1988-1995
Inherent electrical properties of cells can be beneficial to characterize different cell lines and their response to experimental drugs. This paper presents a novel method to characterize the response of breast cancer cells to drug stimuli through use of off‐chip passivated‐electrode insulator‐based dielectrophoresis (OπDEP) and the application of AC electric fields. This work is the first to demonstrate the ability of OπDEP to differentiate between two closely related breast cancer cell lines, LCC1 and LCC9 while assessing their drug sensitivity to an experimental anti‐cancer agent, Obatoclax. Although both cell lines are derivatives of estrogen‐responsive MCF‐7 breast cancer cells, growth of LCC1 is estrogen independent and anti‐estrogen responsive, while LCC9 is both estrogen‐independent and anti‐estrogen resistant. Under the same operating conditions, LCC1 and LCC9 had different DEP profiles. LCC1 cells had a trapping onset (crossover) frequency of 700 kHz and trapping efficiencies between 30–40%, while LCC9 cells had a lower crossover frequency (100 kHz) and showed higher trapping efficiencies of 40–60%. When exposed to the Obatoclax, both cell lines exhibited dose‐dependent shifts in DEP crossover frequency and trapping efficiency. Here, DEP results supplemented with cell morphology and proliferation assays help us to understand the response of these breast cancer cells to Obatoclax.  相似文献   

4.
Dielectrophoresis is a noninvasive, nondestructive, inexpensive, and fast technique for the manipulation of bioparticles. Recent advances in the field of dielectrophoresis (DEP) have resulted in new approaches for characterizing the behavior of particles and cells using direct current (DC) electric fields. In such approaches, spatial nonuniformities are created in the channel by embedding insulating obstacles in the channel or flow field in order to perform separation or trapping. This emerging field of dielectrophoresis is commonly termed DC insulator dielectrophoresis (DC-iDEP), insulator-based dielectrophoresis (iDEP), or electrodeless dielectrophoresis (eDEP). In many microdevices, this form of dielectrophoresis has advantages over traditional AC-DEP, including single material microfabrication, remotely positioned electrodes, and reduced fouling of the test region. DC-iDEP applications have included disease detection, separation of cancerous cells from normal cells, and separation of live from dead bacteria. However, there is a need for a critical report to integrate these important research findings. The aim of this review is to provide an overview of the current state-of-art technology in the field of DC-iDEP for the separation and trapping of inert particles and cells. In this article, a review of the concepts and theory leading to the manipulation of particles via DC-iDEP is given, and insulating obstacle geometry designs and the characterization of device performance are discussed. This review compiles and compares the significant findings obtained by researchers in handling and manipulating particles.  相似文献   

5.
The performance of conventional surface plasmon resonance (SPR) biosensors can be limited by the diffusion of the target analyte to the sensor surface. This work presents an SPR biosensor that incorporates an active mass‐transport mechanism based on dielectrophoresis and electroosmotic flow to enhance analyte transport to the sensor surface and reduce the time required for detection. Both these phenomena rely on the generation of AC electric fields that can be tailored by shaping the electrodes that also serve as the SPR sensing areas. Numerical simulations of electric field distribution and microparticle trajectories were performed to choose an optimal electrode design. The proposed design improves on previous work combining SPR with DEP by using face‐to‐face electrodes, rather than a planar interdigitated design. Two different top‐bottom electrode designs were experimentally tested to concentrate firstly latex beads and secondly biological cells onto the SPR sensing area. SPR measurements were then performed by varying the target concentrations. The electrohydrodynamic flow enabled efficient concentration of small objects (3 μm beads, yeasts) onto the SPR sensing area, which resulted in an order of magnitude increased SPR response. Negative dielectrophoresis was also used to concentrate HEK293 cells onto the metal electrodes surrounded by insulating areas, where the SPR response was improved by one order of magnitude.  相似文献   

6.
A microfluidic chip for multistep manipulations of PMMA submicron particles (PMMA‐SMPs) based on dielectrophoresis (DEP) has been developed that includes four main functions of focusing, guiding, trapping, and releasing the SMPs. The structure of the DEP chip consists of a top electrode made of indium tin oxide, a flow chamber formed by optically clear adhesive tape and bottom electrodes with different patterns for different purposes. The bottom electrodes can be divided into three parts: a fish‐bone‐type electrode array that provides the positive DEP force for focusing the suspended nanoparticles (NPs) near the inlet in the flow chamber; the second is for switching and guiding the focused NPs along the electrode surface to the target area, like a flow passing along a virtual channel; and a trapping electrode in the downstream for trapping and releasing the guided NPs. According to the simulation and experimental results, NPs can be aligned along the electrode of the focusing electrode and guided toward the target electrode by means of a positive DEP force between the top and bottom electrodes, with the effects of Brownian motion and Stokes force. In order to demonstrate the sequence of DEP manipulations, a PMMA‐NP suspension is introduced to the DEP chip; the size of the PMMA‐SMPs is about 300 nm. Furthermore, a LabVIEW program developed for sequence control of the AC signals for the multistep manipulations. Consequently, the DEP chip provides an excellent platform technology for the multistep manipulation of SMPs.  相似文献   

7.
Dielectrophoretic (DEP) force is exerted when a neutral particle is polarized in a non-uniform electric field, and depends on the dielectric properties of the particle and the suspending medium. The integration of DEP and microfluidic systems offers numerous applications for the separation, trapping, assembling, transportation, and characterization of micro/nano particles. This article reviews the applications of DEP forces in microfluidic systems. It presents the theory of dielectrophoresis, different configurations, and the applications of such systems for particle manipulation and device fabrication.  相似文献   

8.
Aldaeus F  Lin Y  Roeraade J  Amberg G 《Electrophoresis》2005,26(22):4252-4259
One of the major applications for dielectrophoresis is selective trapping and fractionation of particles. If the surrounding medium is of low conductivity, the trapping force is high, but if the conductivity increases, the attraction decreases and may even become negative. However, high-conductivity media are essential when working with biological material such as living cells. In this paper, some basic calculations have been performed, and a model has been developed which employs both positive and negative dielectrophoresis in a channel with interdigitated electrodes. The finite element method was utilized to predict the trajectories of Escherichia coli bacteria in the superpositioned electrical fields. It is shown that a drastic improvement of trapping efficiency can be obtained in this way, when a high conductivity medium is employed.  相似文献   

9.
Microelectrode arrays are used to sort single fluorescently labeled cells and particles as they flow through a microfluidic channel using dielectrophoresis. Negative dielectrophoresis is used to create a “Dielectrophoretic virtual channel” that runs along the center of the microfluidic channel. By switching the polarity of the electrodes, the virtual channel can be dynamically reconfigured to direct particles along a different path. This is demonstrated by sorting particles into two microfluidic outlets, controlled by an automated system that interprets video data from a color camera and makes complex sorting decisions based on color, intensity, size, and shape. This enables the rejection of particle aggregates and other impurities, and the system is optimized to isolate high purity populations from a heterogeneous sample. Green beads are isolated from an excess of red beads with 100% purity at a rate of up to 0.9 particles per second, in addition application to the sorting of osteosarcoma and human bone marrow cells is evidenced. The extension of Dielectrophoretic Virtual Channels to an arbitrary number of sorting outputs is examined, with design, simulation, and experimental verification of two alternate geometries presented and compared.  相似文献   

10.
The development of biomimetic microenvironments will improve cell culture techniques by enabling in vitro cell cultures that mimic in vivo behavior; however, experimental control over attachment, cellular position, or intercellular distances within such microenvironments remains challenging. We report here the rapid and controllable immobilization of suspended mammalian cells within microfabricated environments using a combination of electronic (dielectrophoresis, DEP) and chemical (polyelectrolyte multilayers, PEMS) forces. While cellular position within the microsystem is rapidly patterned via intermittent DEP trapping, persistent adhesion after removal of electronic forces is enabled by surface treatment with PEMS that are amenable to cellular attachment. In contrast to DEP trapping alone, persistent adhesion enables the soluble microenvironment to be systematically varied, facilitating the use of soluble probes of cell state and enabling cellular characterization in response to various soluble stimuli.  相似文献   

11.
The spatial and temporal control of biological species is essential in complex microfluidic biosystems. In addition, if the biological species is a cell, microfluidic handling must ensure that the cell's metabolic viability is maintained. The use of DEP for cell manipulation in microfluidics has many advantages because it is remote and fast, and the voltages required for cell trapping scale well with miniaturization. In this paper, the conditions for bacterial cell (Escherichia coli) trapping using a quadrupole electrode configuration in a PDMS microfluidic channel were developed both for stagnant and for in‐flow fluidic situations. The effect of the electrical conductivity of the fluid, the applied electric field and frequency, and the fluid‐flow velocity were studied. A dynamic exchange between captured and free‐flowing cells during DEP trapping was demonstrated. The metabolic activity of trapped cells was confirmed by using E. coli cells genetically engineered to express green fluorescent protein under the control of an inducible promoter. Noninduced cells trapped by negative DEP and positive DEP were able to express green fluorescent protein minutes after the inducer was inserted in the microchannel system immediately after DEP trapping. Longer times of trapping prior to exposure to the inducer indicated first a degradation of the cell metabolic activity and finally cell death.  相似文献   

12.
Many biomedical analysis applications require trapping and manipulating single cells and cell clusters within microfluidic devices. Dielectrophoresis (DEP) is a label-free technique that can achieve flexible cell trapping, without physical barriers, using electric field gradients created in the device by an electrode microarray. Little is known about how fluid flow forces created by the electrodes, such as thermally driven convection and electroosmosis, affect DEP-based cell capture under high conductance media conditions that simulate physiologically relevant fluids such as blood or plasma. Here, we compare theoretical trajectories of particles under the influence of negative DEP (nDEP) with observed trajectories of real particles in a high conductance buffer. We used 10-µm diameter polystyrene beads as model cells and tracked their trajectories in the DEP microfluidic chip. The theoretical nDEP trajectories were in close agreement with the observed particle behavior. This agreement indicates that the movement of the particles was highly dominated by the DEP force and that contributions from thermal- and electroosmotic-driven flows were negligible under these experimental conditions. The analysis protocol developed here offers a strategy that can be applied to future studies with different applied voltages, frequencies, conductivities, and polarization properties of the targeted particles and surrounding medium. These findings motivate further DEP device development to manipulate particle trajectories for trapping applications.  相似文献   

13.
Porous polymer monoliths have been used to develop an online solid‐phase extraction with liquid chromatography method for determination of dopamine in urine as well as for a continuous monitoring of dopamine in flowing system. A polymerization mixture containing 4‐vinylphenylboronic acid monomer has been used to prepare a trapping column based on specific ring formation reaction with dopamine cis‐diol functionality. Additionally, a monolithic stationary phase with zwitterion functionality has been used to prepare capillary column for the separation of dopamine. Experimental conditions including molarity, pH, and flow rate of the loading buffer together with a valve switching time have been optimized to provide the highest recovery for dopamine. Experimental setup has been used to determine dopamine in a urine. By using both calibration curve and standard addition method, the dopamine level was determined to be 1.19 and 1.28 mg/L, respectively. Further, we have used experimental design to optimize coupling of two extraction monolithic loops to separation capillary column with monolithic phase for a comprehensive monitoring of dopamine. After multivariate analysis, sample loading flow‐rate and a flow‐rate of flushing buffer were selected as the most significant variables. Optimized experimental setup was applied to continuously monitor dopamine degradation.  相似文献   

14.
Monitoring the real-time behavior of spatial arrays of single living bacteria cells is only achieved with much experimental difficulty due to the small size and mobility of the cells. To address this problem, we have designed and constructed a simple microfluidic device capable of trapping single bacteria cells in spatially well-defined locations without the use of chemical surface treatments. The device exploits hydrodynamics to slow down and trap cells flowing near a narrow aperture. We have modeled this system numerically by approximating the motion of Escherichia coli cells as rigid 3-D ellipsoids. The numerical predictions for the speed and efficiency of trapping were tested by fabricating the devices and imaging GFP expressing E. coli at a high spatio-temporal resolution. We find that our numerical simulations agree well with the actual cell flow for varying trap geometries. The trapped cells are optically accessible, and combined with our ability to predict their spatial location we demonstrate the ease of this method for monitoring multiple single cells over a time course. The simplicity of the design, inexpensive materials and straightforward fabrication make it an accessible tool for any systems biology laboratory.  相似文献   

15.
Electrokinetically driven insulator-based microfluidic devices represent an attractive option to manipulate particle suspensions. These devices can filtrate, concentrate, separate, or characterize micro and nanoparticles of interest. Two decades ago, inspired by electrode-based dielectrophoresis, the concept of insulator-based dielectrophoresis (iDEP) was born. In these microfluidic devices, insulating structures (i.e., posts, membranes, obstacles, or constrictions) built within the channel are used to deform the spatial distribution of an externally generated electric field. As a result, particles suspended in solution experience dielectrophoresis (DEP). Since then, it has been assumed that DEP is responsible for particle trapping in these devices, regardless of the type of voltage being applied to generate the electric field—direct current (DC) or alternating current. Recent findings challenge this assumption by demonstrating particle trapping and even particle flow reversal in devices that prevent DEP from occurring (i.e., unobstructed long straight channels stimulated with a DC voltage and featuring a uniform electric field). The theory introduced to explain those unexpected observations was then applied to conventional “DC-iDEP” devices, demonstrating better prediction accuracy than that achieved with the conventional DEP-centered theory. This contribution summarizes contributions made during the last two decades, comparing both theories to explain particle trapping and highlighting challenges to address in the near future.  相似文献   

16.
G Mottet  B Le Pioufle  LM Mir 《Electrophoresis》2012,33(16):2508-2515
In this study, we analyzed the electrofusion of two cells in a biochip that has been developed to perform the capture by dielectrophoresis and the electrofusion of pairs of cells. The good transparency of the microsystem allowed analyzing the details of the fusion events. By staining one of the cells, the mixing of the two cytosols could be observed during the electrofusion experiment. We show for the first time the rapidity of the mixing of the two cytosols: less than 5 s under our experimental conditions. By comparing these experimental results to a numerical simulation, we found that the rate of this phenomenon is compatible with a diffusion-only mechanism, showing that during the fusion, the two cell membranes in contact are affected by very rapid structural changes and do not limit the exchange of the cytosols between the two cells. A point of interest is the use of dielectric structures to concentrate the electric field and of positive dielectrophoresis to capture cells in the area where the electric field is more intense. This technique allows the increase of the cell-to-cell contact and limits cell cytosol leakages during the fusion process.  相似文献   

17.
Microfluidic device embedding electrodes realizes cell manipulation with the help of dielectrophoresis. Cell manipulation is an important technology for cell sorting and cell population purification. Till now, the theory of dielectrophoresis has been greatly developed. Microfluidic devices with various arrangements of electrodes have been reported from the beginning of the single non‐uniform electric field to the later multiple physical fields. This paper reviews the research status of microfluidic device embedding electrodes for cell manipulation based on dielectrophoresis. Firstly, the working principle of dielectrophoresis is explained. Next, cell manipulation approaches based on dielectrophoresis are introduced. Then, different types of electrode arrangements in the microfluidic device for cell manipulation are discussed, including planar, multilayered and microarray dot electrodes. Finally, the future development trend of the dielectrophoresis with the help of microfluidic devices is prospected. With the rapid development of microfluidic technology, in the near future, high precision, high throughput, high efficiency, multifunctional, portable, economical and practical microfluidic dielectrophoresis will be widely used in the fields of biology, medicine, agriculture and so on.  相似文献   

18.
Hawkins BG  Kirby BJ 《Electrophoresis》2010,31(22):3622-3633
We simulate electrothermally induced flow in polymeric, insulator-based dielectrophoresis (iDEP) systems with DC-offset, AC electric fields at finite thermal Péclet number, and we identify key regimes where electrothermal (ET) effects enhance particle deflection and trapping. We study a single, two-dimensional constriction in channel depth with parametric variations in electric field, channel geometry, fluid conductivity, particle electrophoretic (EP) mobility, and channel electroosmotic (EO) mobility. We report the effects of increasing particle EP mobility, channel EO mobility, and AC and DC field magnitudes on the mean constriction temperature and particle behavior. Specifically, we quantify particle deflection and trapping, referring to the deviation of particles from their pathlines due to dielectrophoresis as they pass a constriction and the stagnation of particles due to negative dielectrophoresis near a constriction, respectively. This work includes the coupling between fluid, heat, and electromagnetic phenomena via temperature-dependent physical parameters. Results indicate that the temperature distribution depends strongly on the fluid conductivity and electric field magnitude, and particle deflection and trapping depend strongly on the channel geometry. Electrothermal (ET) effects perturb the EO flow field, creating vorticity near the channel constriction and enhancing the deflection and trapping effects. ET effects alter particle deflection and trapping responses in insulator-based dielectrophoresis devices, especially at intermediate device aspect ratios (2 ≤ r ≤ 7) in solutions of higher conductivity (σ m ≥ 1 × 10(-3)S/m). The impact of ET effects on particle deflection and trapping are diminished when particle EP mobility or channel EO mobility is high. In almost all cases, ET effects enhance negative dielectrophoretic particle deflection and trapping phenomena.  相似文献   

19.
The limiting flux induces a performance limitation of ultrafiltration systems, the understanding of this phenomenon and the ability to predict the limiting flux are essential for improving the design and operation of ultrafiltration processes. A new cell design, an annular cell fitted with a tangential inlet, which induces a swirling decaying flow, is tested. Performances of this ultrafiltration unit configuration are compared with two other more classical geometries: a simple plane unit and an annular cell involving mainly axial flow. The cross-flow ultrafiltration of dilute suspensions of bentonite is studied under specific operating conditions in the three different configurations of filtration cells. The improvement of the permeation flux in the swirling cell, compared with that measured in the two other configurations, can reach 70% for a wall velocity gradient of 800 s−1. This enhancement is highly linked to the removal of particles deposited at the membrane surface owing to the three-dimensional fluid flow involved in this particular cell. The bentonite deposit is compressible and characteristics of particles accumulation at the membrane surface are investigated.  相似文献   

20.
In this study, a dielectrophoresis field‐flow fractionation device was analyzed using a numerical simulation method and the behaviors of a set of different cells were investigated. By reducing the alternating current frequency of the electrodes from the value used in the original setup configuration and increasing the number of exit channels, total discrimination in cell trajectories and subsequent separation of four cell types were achieved. Cells were differentiated based on their size and dielectric response that are represented in their real part of Clausius–Mossotti factor at different frequencies. A number of novel designs were also proposed based on the original setup configuration. It was seen that by reducing the length of the main channel and the number of electrodes at low frequencies and not changing the inlet flow velocities, cell separation was still achieved successfully, although with a slightly larger electrode voltage. The shorter main channel decreased the residence time for the cells on the chip and also reduced the overall size of the device—these were improvements over the original design. The obtained results can be used to analyze other cell types by knowing their size and dielectric properties to design geometries that can ensure separation.  相似文献   