1.
We introduce here a method for continuous intact cell detection and viability determination of individual trypan blue stained cells by CE with ultraviolet–visible dual‐wavelength detection. To avoid cell aggregation or damage during electrophoresis, cells after staining were fixed with 4% formaldehyde and were continuously introduced into the capillary by EOF. The absorbance of a cell at 590 nm was used to determine its viability. An absorbance of two milli‐absorbance unit at 590 nm was the clear cut‐off point for living and dead Hela cells in our experiments. Good viability correlation between the conventional trypan blue staining assay and our established CE method (correlation coefficient, R2=0.9623) was demonstrated by analysis of cell mixtures with varying proportions of living and dead cells. The CE method was also used to analyze the cytotoxicity of methylmercury, and the results were in good agreement with the trypan blue staining assay and 3‐(4,5‐dimethyl‐2‐thiazyl)‐2,5‐diphenyl‐2H‐tetrazolium bromide methods. Compared with the 3‐(4,5‐dimethyl‐2‐thiazyl)‐2,5‐diphenyl‐2H‐tetrazolium bromide method, our established CE method can be easily automated to report cell viability based on the state of individual cells. Tedious manual cell counting and human error due to investigator bias can be avoided by using this method.  相似文献   

2.
In the present work, chemiluminescence detection was integrated with capillary electrophoresis microchip. The microchip was designed on the principle of flow-injection chemiluminescence system and capillary electrophoresis. It has three main channels, five reservoirs and a detection cell. As model samples, dopamine and catechol were separated and detected using a permanganate chemiluminescent system on the prepared microchip. The samples were electrokinetically injected into the double-T cross section, separated in the separation channel, and then oxidized by chemiluminescent reagent delivered by a home-made micropump to produce light in the detection cell. The electroosmotic flow could be smoothly coupled with the micropump flow. The detection limits for dopamine and catechol were 20.0 and 10.0 μM, respectively. Successful separation and detection of dopamine and catechol demonstrated the distinct advantages of integration of chemiluminescent detection on a microchip for rapid and sensitive analysis.  相似文献   

3.
4.
We developed a method for the direct identification of dopamine in single cultured rat pheochromocytoma cells by capillary electrophoresis using an end‐channel carbon fiber nanoelectrode amperometric detector. The operation mode was designed to achieve single‐cell injection and lysis in microfluidic chip electrophoresis with only one high‐voltage power supply. The separation and detection conditions were optimized. Four catecholamines were baseline‐separated and determined with this system, and the cell density and liquid height of the reservoirs were accommodated for single cell loading, docking and analysis. The microchip capillary electrophoresis system was successfully applied to determine dopamine in single cultured rat pheochromocytoma cells.  相似文献   

5.
Xu Y  Chen S  Feng X  Du W  Luo Q  Liu BF 《Electrophoresis》2008,29(3):734-739
Multiphoton-excited fluorescence (MPEF) is a complementary and useful mode of LIF detection in CE with advantages of ultra-low mass detectability and spectral excitability, but it is currently quite limited by its end-column configuration. In this article, we demonstrate a novel strategy of on-column schemes that can greatly facilitate MPEF detection in CE. FITC-labeled amine species were used as the model samples for the evaluation and comparison of those detection scenarios. By using the square capillary instead of the conventional cylindrical one, the on-column MPEF could be readily achieved, with detection sensitivity of 0.72 microM that was comparable with the end-column mode. However, this strategy unfavorably reduced separation efficiency. The theoretical plate number on averaging all the sample peaks was significantly decreased from 283,000 to 19,000/m. To minimize such an influence, a short square capillary acting as an on-column MPEF detection cell was then mounted to a long cylindrical capillary responsible for the CE separation. Results indicated that both high separation efficiency (240,000/m) and better detectability (0.42 microM) were realized simultaneously by using this binary-capillary configuration. Quantitative analysis was performed under the optimized detector configuration and revealed a linear dynamic range of 2 orders of magnitude, with mass detection limit down to the mid-yottomole level.  相似文献   

6.
Paracetamol, caffeine and ibuprofen are found in over‐the‐counter pharmaceutical formulations. In this work, we propose two new methods for simultaneous determination of paracetamol, caffeine and ibuprofen in pharmaceutical formulations. One method is based on high‐performance liquid chromatography with diode‐array detection and the other on capillary electrophoresis with capacitively coupled contactless conductivity detection. The separation by high‐performance liquid chromatography with diode‐array detection was achieved on a C18 column (250×4.6 mm2, 5 μm) with a gradient mobile phase comprising 20–100% acetonitrile in 40 mmol L?1 phosphate buffer pH 7.0. The separation by capillary electrophoresis with capacitively coupled contactless conductivity detection was achieved on a fused‐silica capillary (40 cm length, 50 μm i.d.) using 10 mmol L?1 3,4‐dimethoxycinnamate and 10 mmol L?1 β‐alanine with pH adjustment to 10.4 with lithium hydroxide as background electrolyte. The determination of all three pharmaceuticals was carried out in 9.6 min by liquid chromatography and in 2.2 min by capillary electrophoresis. Detection limits for caffeine, paracetamol and ibuprofen were 4.4, 0.7, and 3.4 μmol L?1 by liquid chromatography and 39, 32, and 49 μmol L?1 by capillary electrophoresis, respectively. Recovery values for spiked samples were between 92–107% for both proposed methods.  相似文献   

7.
A multi‐channel microchip electrophoresis using a programmed step electric field strength (PSEFS) method was investigated for fast parallel detection of feline panleukopenia virus (FPV) DNA. An expanded laser beam, a 10× objective lens, and a charge‐coupled device camera were used to simultaneously detect the separations in three parallel channels using laser‐induced fluorescence detection. The parallel separations of a 100‐bp DNA ladder were demonstrated on the system using a sieving gel matrix of 0.5% poly(ethylene oxide) (Mr = 8 000 000) in the individual channels. In addition, the PSEFS method was also applied for faster DNA separation without loss of resolving power. A DNA size marker, FPV DNA sample, and a negative control were simultaneously analyzed with single‐run and one‐step detection. The FPV DNA was clearly distinguished within 30 s, which was more than 100 times faster than with conventional slab gel electrophoresis. The proposed multi‐channel microchip electrophoresis with PSEFS was demonstrated to be a simple and powerful diagnostic method to analyze multiple disease‐related DNA fragments in parallel with high speed, throughput, and accuracy.  相似文献   

8.
A microfluidic device with integrated waveguides and a long path length detection cell for UV/Vis absorbance detection is presented. The 750 microm U-cell detection geometry was evaluated in terms of its optical performance as well as its influence on efficiency for electrophoretic separations in the microdevice. Stray light was found to have a strong effect on both, the sensitivity of the detection and the available linear range. The long path length U-cell showed a 9 times higher sensitivity when compared to a conventional capillary electrophoresis (CE) system with a 75 microm inner diameter (ID) capillary, and a 22 times higher sensitivity than with a 50 microm ID capillary. The linear range was comparable to that achieved in a 75 microm ID capillary and more than twice as large as in a 50 microm ID capillary. The use of the 750 microm U-cell did not contribute significantly to band broadening; however, a clear quantification was made difficult by the convolution of several other band broadening sources.  相似文献   

9.
A voltage‐programming‐based capillary gel electrophoresis method with a laser‐induced fluorescence detector was developed for the fast and highly sensitive detection of DNA molecules related to angiotensin‐converting enzyme insertion/deletion polymorphism, which has been reported to influence predisposition to various diseases such as cardiovascular disease, high blood pressure, myocardial infarction, and Alzheimer's disease. Various voltage programs were investigated for fast detection of specific DNA molecules of angiotensin‐converting enzyme insertion/deletion polymorphism as a function of migration time and separation efficiency to establish the effect of voltage strength to resolution. Finally, the amplified products of the angiotensin‐converting enzyme insertion/deletion polymorphism (190 and 490 bp DNA) were analyzed in 3.2 min without losing resolution under optimum voltage programming conditions, which were at least 75 times faster than conventional slab gel electrophoresis. In addition, the capillary gel electrophoresis method also successfully applied to the analysis of real human blood samples, although no polymorphism genes were detected by slab gel electrophoresis. Consequently, the developed voltage‐programming capillary gel electrophoresis method with laser‐induced fluorescence detection is an effective, rapid analysis technique for highly sensitive detection of disease‐related specific DNA molecules.  相似文献   

10.
Chen C  Teng W  Hahn JH 《Electrophoresis》2011,32(8):838-843
A nanoband electrode detector integrated with a dual-channel polydimethylsiloxane microchip is proposed for in-channel amperometric detection in microchip capillary electrophoresis. Gold nanoband electrodes, which were fabricated on SU-8 substrates with a 100-nm-width gold layer, were introduced into the dual-channel microchip to be an electrochemical detector. Due to the nano-sized width of the detector, the noise of the amperometric detection was significantly reduced, and a high separation resolution was achieved for monitoring the analytes. The detection sensitivity of the system was improved by high signal-to-noise ratio, and a low detection limit on microchip was obtained for p-aminophenol (2.09 nM). Because of the high resolution in measuring half-peak width, the plate number that is used to evaluate the separation efficiency was 1.5-fold higher than that using 50-μm-width electrochemical detector. The effect of sample injection time and data acquisition time on separation efficiency was investigated, and an attractive separation efficiency was achieved with a plate number up to 17,500.  相似文献   

11.
Point‐of‐care systems based on microchip capillary electrophoresis require single‐use, disposable microchips prefilled with all necessary solutions so an untrained operator only needs to apply the sample and perform the analysis. While microchip fabrication can be (and has been) standardized, some manufacturing differences between microchips are unavoidable. To improve analyte precision without increasing device costs or introducing additional error sources, we recently proposed the use of integrated internal standards (ISTDs): ions added to the BGE in small concentrations which form system peaks in the electropherogram that can be used as a measurement reference. Here, we further expand this initial proof‐of‐principle test to study a clinically‐relevant application of K ion concentrations in human blood; however, using a mock blood solution instead of real samples to avoid interference from other obstacles (e.g. cell lysis). Cs as an integrated ISTD improves repeatability of K ion migration times from 6.97% to 0.89% and the linear calibration correlation coefficient (R2) for K quantification from 0.851 to 0.967. Peak area repeatability improves from 11.6–13.3% to 4.75–5.04% at each K concentration above the LOQ. These results further validate the feasibility of using integrated ISTDs to improve imprecision in disposable microchip CE devices by demonstrating their application for physiological samples.  相似文献   

12.
A capillary electrophoresis microchip is used to selectively and sensitively monitor cyanide levels in both vapor (HCN((g))) and aqueous (NaCN in drinking water) phases. Laser-induced fluorescence detection is applied using a violet diode laser to monitor the fluorescent isoindole derivative formed by the reaction of cyanide with 2,3-naphthalenedicarboxaldehyde (NDA) and taurine. Air sampling of hydrogen cyanide is achieved using a miniature impinger (2 mL), giving collection efficiencies as high as 79% for a sampling rate of 1.0 L/min and a 10 s sampling time (relative standard deviation RSD: 2.7% for n = 5). Following the addition of NDA and taurine to either the vapor phase impinger sample or an aqueous drinking water sample, the NDA/cyanide derivative can be detected in just over 40 s on the microchip, giving a detection limit of 0.56 microg/L and a linear dynamic range from 0.56 microg/L-2.4 mg/L. The detection limit for hydrogen cyanide in air was determined to be 2.3 ppb (mole%). On-chip derivatization of cyanide by NDA was successful, although a 50% decrease in signal intensity was observed due to insufficient time for completion of the reaction on the microchip. A number of different interferents were examined, and only iron(II) and chlorine showed any interference due to their capability for masking the presence of cyanide by reacting with free cyanide in solution.  相似文献   

13.
A capillary electrophoresis (CE) microchip made of a new and promising polymeric material: Topas (thermoplastic olefin polymer of amorphous structure), a cyclic olefin copolymer with high chemical resistance, has been tested for the first time with analytical purposes, employing an electrochemical detection. A simple end-channel platinum amperometric detector has been designed, checked, and optimized in a poly-(methylmethacrylate) (PMMA) CE microchip. The end-channel design is based on a platinum wire manually aligned at the exit of the separation channel. This is a simple and durable detection in which the working electrode is not pretreated. H(2)O(2) was employed as model analyte to study the performance of the PMMA microchip and the detector. Factors influencing migration and detection processes were examined and optimized. Separation of H(2)O(2) and L-ascorbic acid (AsA) was developed in order to evaluate the efficiency of microchips using different buffer systems. This detection has been checked for the first time with a microchip made of Topas, obtaining a good linear relationship for mixtures of H(2)O(2) and AsA in different buffers.  相似文献   

14.
A microfabricated thin glass chip for contactless conductivity detection in chip capillary electrophoresis is presented in this contribution. Injection and separation channels were photolithographed and chemically etched on the surface of substrate glass, which was bonded with a thin cover glass (100 μm) to construct a new microchip. The chip was placed over an independent contactless electrode plate. Owing to the thinness between channel and electrodes, comparatively low excitation voltage (20–110 V in Vp–p) and frequency (40–65 kHz) were suitable, and favorable signal could be obtained. This microchip capillary electrophoresis device was used in separation and detection of inorganic ions, amino acids and alkaloids in amoorcorn tree bark and golden thread in different buffer solutions. The detection limit of potassium ion was down to 10 μmol/L. The advantages of this microchip system exist in the relative independence between the microchip and the detection electrodes. It is convenient to the replacement of chip and other operations. Detection in different position of the channel would also be available.  相似文献   

15.
This research examines microchip electrophoresis with linear imaging UV detection for the analysis of antimicrobial metabolites, monoacetylphloroglucinol (MAPG) and 2,4-diacetylphloroglucinol (2,4-DAPG) from Pseudomonas fluorescens F113. Initial results show the separation of MAPG, 2,4-DAPG and resorcinol in less than 20 s. This was achieved using a quartz microchip with a separation channel length of 25 mm. In order to quantitate the amount of MAPG and 2,4-DAPG in a microbial cultured supernatant sample, on-chip sample introduction in a methanol/buffer matrix was investigated. Sample introduction/injection parameters were optimized to improve sensitivity and thus decrease the limit of detection (LOD). The amount of antimicrobial metabolites present was quantitated with a separation time of 15 s. A previously developed capillary electrophoretic method was compared to the microchip method in relation to speed, efficiency, precision, linear range and limit of detection. This investigation shows the fastest separation so far of these antimicrobial metabolites with high efficiency.  相似文献   

16.
Ruecha N  Siangproh W  Chailapakul O 《Talanta》2011,84(5):1323-1328
In this work, the rapid detection of cholesterol using poly(dimethylsiloxane) microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, was developed. Direct amperometric detection for poly(dimethylsiloxane) (PDMS) microchip capillary electrophoresis was successfully applied to quantify cholesterol levels. Factors influencing the performance of the method (such as the concentration and pH value of buffer electrolyte, concentration of cholesterol oxidase enzyme (ChOx), effect of solvent on the cholesterol solubility, and interferences) were carefully investigated and optimized. The migration time of hydrogen peroxide, product of the reaction, was less than 100 s when using 40 mM phosphate buffer at pH 7.0 as the running buffer, a concentration of 0.68 U/mL of the ChOx, a separation voltage of +1.6 kV, an injection time of 20 s, and a detection potential of +0.5 V. PDMS microchip capillary electrophoresis showed linearity between 38.7 μg/dL (1 μM) and 270.6 mg/dL (7 mM) for the cholesterol standard; the detection limit was determined as 38.7 ng/dL (1 nM). To demonstrate the potential of this assay, the proposed method was applied to quantify cholesterol in bovine serum. The percentages of recoveries were assessed over the range of 98.9-101.8%. The sample throughput was found to be 60 samples per hour. Therefore, PDMS microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, is very rapid, accurate and sensitive method for the determination of cholesterol levels.  相似文献   

17.
With the emergence of new viral infections and pandemics, there is a need to develop faster methods to unravel the virus identities in a large number of clinical samples. This report describes a virus identification method featuring high throughput, high resolution, and high sensitivity detection of viruses. Identification of virus is based on liquid hybridization of different lengths of virus-specific probes to their corresponding viruses. The probes bound to target sequences are removed by a biotin–streptavidin pull-down mechanism and the supernatant is analyzed by capillary electrophoresis. The probes depleted from the sample appear as diminished peaks in the electropherograms and the remaining probes serve as calibrators to align peaks in different capillaries. The virus identities are unraveled by a signal processing and peak detection algorithm developed in-house. Nine viruses were used in the study to demonstrate how the system works to unravel the virus identity in single and double virus infections. With properly designed probes, the system is able to distinguish closely related viruses. The system takes advantage of the high resolution feature of capillary electrophoresis to resolve probes that differ by length. The method may facilitate virus identity screen from more candidate viruses with an automated 4-color DNA sequencer.  相似文献   

18.
1-Phenyl-3-methyl-5-pyrazolone (PMP) derivatives of monosaccharides were analyzed by electrophoresis on a quartz microchip with whole-channel UV detection. Rapid separation of PMP derivatives of aldopentoses was achieved by plain-zone electrophoresis in a neutral phosphate buffer with the height equivalent to a theoretical plate at the micrometer level. Zone electrophoresis as borate complexes was also successful for the separation of PMP derivatives of a few aldoses, which were separated within 1 min. Separation by microchip electrophoresis was compared to that by capillary electrophoresis, and the difference was discussed in terms of column efficiency and sample column capacity.  相似文献   

19.
Nearly all processes in living organisms are controlled and regulated by the synergy of many biomolecule interactions involving proteins, peptides, nucleic acids, nucleotides, saccharides, and small molecular weight ligands. There is growing interest in understanding them, not only for the purposes of interactomics as an essential part of system biology, but also in their further elucidation in disease pathology, diagnostics, and treatment. The necessity of detailed investigation of these interactions leads to the requirement of laboratory methods characterized by high efficiency and sensitivity. As a result, many instrumental approaches differing in their fundamental principles have been developed, including those based on capillary electrophoresis. Although capillary electrophoresis offers numerous advantages for such studies, it still has one serious limitation, its poor concentration sensitivity with the most commonly used detection method–ultraviolet‐visible spectrometry. However, coupling capillary electrophoresis with a more sensitive detector fulfils the above‐mentioned requirement. In this review, capillary electrophoresis combined with fluorescence, mass spectrometry, and several nontraditional detection techniques in affinity interaction studies are summarized and discussed, together with the possibility of conducting these measurements in microchip format.  相似文献   

20.
We describe an efficient and easily fabricated electrochemiluminescence detection system for microchip capillary electrophoresis. A 300-μm-diameter platinum disc working electrode was embedded in a titanium tube which provides an adequate holding for working electrode and acts as counter electrode. We also have designed a simplified detection cell with a guide channel for the electrode. The integrated working-counter electrode can be easily aligned to the outlet of the separation channel through the guide channel. The functionality of the system was demonstrated by separation and detection of proline and tripropylamine. The response to proline is linear in the range from 5 μM to 5,000 μM, and the detection limit is 1.0 μM (S/N?=?3). The system was further applied to the determination of chlorpromazine hydrochloride in pharmaceutical formulations. The system is believed to have potential applications in pharmaceutical analysis.
Figure
We described an efficient and easily fabricated electrochemiluminescence detection system for microchip capillary electrophoresis. The functionality of the system was demonstrated by separation and detection of proline and tripropylamine. The response to proline is linear in the range from 5 μM to 5,000 μM, and the detection limit is 1.0 μM (S/N?=?3).  相似文献   