首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Electroanalysis》2017,29(6):1626-1634
A Pt nanoparticle modified Pencil Graphite Electrode (PGE) was proposed for the electrocatalytic oxidation and non‐enzymatic determination of H2O2 in Flow Injection Analysis (FIA) system. Platinum nanoparticles (PtNPs) electrochemically deposited on pretreated PGE (p.PGE) surface by recording cyclic voltammograms of 1.0 mM of H2PtCl6 solution in 0.10 M KCl at scan rate of 50 mV s−1 for 30 cycles. Cyclic voltammograms show that the oxidation peak potential of H2O2 shifts from about +700 mV at bare PGE to +50 mV at PtNPs/p.PGE vs. Ag/AgCl /KCl (sat.). It can be concluded that PtNPs/p.PGE exhibits a good electrocatalytic activity towards oxidation of H2O2. Then, FI amperometric analysis of H2O2 was performed under optimized conditions using a new homemade electrochemical flow cell which was constructed for PGE. Linear range was found as 2.5 μM to 750.0 μM H2O2 with a detection limit of 0.73 μM (based on Sb/m of 3). As a result, this study shows the first study on the FI amperometric determination of H2O2 at PtNPs/p.PGE which exhibits a simple, low cost, commercially available, disposable sensor for H2O2 detection. The proposed electrode was successfully applied to determination of H2O2 in real sample.  相似文献   

2.
Electrodeposition of manganese oxides film onto the cheap pencil graphite electrode using potassium permanganate precursor provides the good alternative method of fabrication the low cost hydrogen peroxide sensor. Effect of deposition potential, deposition time and concentration of potassium permanganate were investigated. The modified electrode displayed electrocatalytic activity towards the oxidation of hydrogen peroxide in alkaline medium. Amperometric detection of hydrogen peroxide in ammonium buffer pH 9.0 is possible at the operation potential of +0.50V vs Ag/AgCl instead of over +0.80V vs Ag/AgCl with unmodified electrode. Linear concentration range between 0.50-138ppm of hydrogen peroxide was obtained with a detection limit of 0.28ppm.  相似文献   

3.
Gold nanoparticles (AuNPs) were electrodeposited on the surface of pencil graphite (PG) by fast scan cyclic voltammetry without using any additives in acidic medium. The effect of deposition time on the size of electrodeposited AuNPs was investigated in sulfuric acid as a supporting electrolyte. The deposition time was varied by varying the scan rate, number of cycles and applied potential range. Scanning electron microscopy (SEM), transmission electron microscopy (TEM) and X‐ray diffraction (XRD) were used for characterization of PG and electrodeposited AuNPs. The results confirmed that nanosized gold particles (20 ± 8 nm) were deposited on the PG substrate with almost spherical geometry.  相似文献   

4.
Gold nanoparticles stabilized in poly(allylamine hydrochloride) (AuNP‐PAH) were synthesized, characterized and applied in the development of a new sensor for the determination of vanillin by square‐wave voltammetry. Under optimized conditions, the calibration curve showed a linear range for vanillin of 0.90 to 15.0 µmol L?1, with a limit of detection of 55 nmol L?1. The sensor demonstrated acceptable selectivity and stability, as well as good intra‐day and inter‐day repeatability and electrode‐to‐electrode repeatability (with relative standard deviations of 3.5, 4.5 and 3.9 %, respectively). The sensor was successfully applied in the determination of vanillin in different commercial samples.  相似文献   

5.
A novel biosensor was developed by entrapping cytochrome c (Cyt c) in thin films of the room temperature ionic liquid (RTIL) containing nanocomposites of poly(diallyldimethylammonium chloride)‐graphene nanosheets‐gold nanoparticles (PDDA‐Gp‐AuNPs) at a 11‐mercaptoundecanoic acid‐6‐mercapto‐1‐hexanol modified gold electrode. The synthesized PDDA‐Gp‐AuNPs hybrid nanocomposites were characterized by UV‐vis spectroscopy, Raman spectroscopy, scanning electron microscopy and atomic force microscopy. The PDDA‐Gp‐AuNPs nanocomposites could increase the effective surface of the electrode, enhance the fixed amount of Cyt c on the electrode surface, promote the electron transfer and facilitate the catalytic activity of Cyt c. The RTIL could provide a biocompatible microenvironment to keep Cyt c biological activities, act as an effective mediator to immobilize a large number of Cyt c on the electrode and have good conductivity to improve electron transfer. Therefore, the resultant electrode exhibited good electrochemical performance and electrocatalytic activity. It could be used for electrochemical detection of H2O2 with rapid response, high sensitivity, wide linear range and low detection limit, as well as good stability, repeatability and selectivity. The sensor might be promising for practical application.  相似文献   

6.
We present a new strategy for the label‐free electrochemical detection of DNA hybridization based on gold nanoparticles (AuNPs)/poly(neutral red) (PNR) modified electrode. Probe oligonucledotides with thiol groups at the 5‐end were covalently linked onto the surface of AuNPs/PNR modified electrode via S‐Au binding. The hybridization event was monitored by using differential pulse voltammetry (DPV) upon hybridization generates electrochemical changes at the PNR‐solution interface. A significant decrease in the peak current was observed upon hybridization of probe with complementary target ssDNA, whereas no obvious change was observed with noncomplementary target ssDNA. And the DNA sensor also showed a high selectivity for detecting one‐mismatched and three‐mismatched target ssDNA and a high sensitivity for detecting complementary target ssDNA, the detection limit is 4.2×10?12 M for complementary target ssDNA. In addition, the DNA biosensor showed an excellent reproducibility and stability under the DNA‐hybridization conditions.  相似文献   

7.
Presently, bisphenol A (BPA) has been added to the list of substances of very high concern as endocrine disruptors. According to the literature, exposure to bisphenol A even at low doses may result in adverse health effects. In this study, electrochemical sensor of Bisphenol A based on thioether DDT‐Poly(N‐vinylpyrrolidone) oligomer has been developed. The thioether oligomer, which is capable of recognizing BPA, was prepared and used for gold electrode modification. The characterization of the modified gold electrode and the synthesized thioether oligomer were carried out by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), atomic force microscopy (AFM), Fourier‐transform infrared spectroscopy (FTIR), proton nuclear magnetic resonance spectroscopy (1H NMR) and Size exclusion chromatography (SEC). Obtained results indicate that the modified electrode shows good electrochemical activity, good sensitivity and reproducibility for BPA detection. It exhibited a good linear relationship ranging from 1 to 20 pg/mL, and the detection limit was found to be 1.9 pg/mL at S/N=3. Several interfering species such as hydroquinone, phenol and resorcinol were used and their behaviors on the modified gold electrode were investigated.  相似文献   

8.
《Electroanalysis》2017,29(5):1214-1221
A highly sensitive enzymeless electrochemical glucose sensor has been developed based on the simply prepared cathodized gold nanoparticle‐modified graphite pencil electrode (AuNP‐GPE). Cyclic voltammetry (CV) experiments show that AuNP‐GPE is able to oxidize glucose partially at low potential (around −0.27) whereas the bare GPE cannot oxidize glucose in the entire tested potential windows. Besides, fructose and sucrose cannot be oxidized at potential lower than +0.1 V at AuNP‐GPE. As a result, the glucose oxidation peak at around −0.27 V is suitable enough for selective detection of glucose in the presence of fructose and sucrose. Cathodization of AuNP‐GPE under optimum condition (‐1.0 V for 30 s) in the same glucose solution before voltammetric measurement enhanced glucose oxidation peak current around −0.27 V to achieve an efficient electrochemical sensor for glucose with a detection limit of 12 μM and dynamic range between 0.05 to 5.0 mM with a good linearity (R2= 0.999). Almost no interference effect was observed for sensing of glucose in the presence of ascorbic acid, alanine, phenylalanine, fructose, sucrose, and NaCl.  相似文献   

9.
Poly(vinyl chloride)‐based membranes of salen ligands, 2‐((E)‐((1R,2S)‐2‐((E)‐5‐tert‐butyl‐2‐hydroxybenzylideneamino)cyclohexylimino)methyl)‐4‐tert‐butyl phenol (S1) and 2‐((E)‐((1R,2S)‐2‐((E)‐3,5‐di‐tert‐butyl‐2‐hydroxybenzylideneamino)cyclohexylimino)methyl)‐4,6‐di‐tert‐butylphenol (S2) were fabricated and explored as cobalt(II) selective electrodes. The performance of the polymeric membrane electrode (PME) and coated graphite electrode (CGE) were compared and it was observed that CGE showed a wide working concentration range of 1.1×10?8 to 1.0×10?1 mol L?1 with a limit of detection of 7.0×10?9 mol L?1 exhibiting the Nernstian slope 29.6 mV/decade of activity in the pH range 3.0–9.0. It was used for the determination of cobalt(II) ions in water, soil, beer, pharmaceutical samples and medicinal plants and would be used as an indicator electrode in potentiometric titration with EDTA.  相似文献   

10.
A gold (Au) nanoparticle-modified graphite pencil electrode was prepared by an electrodeposition procedure for the sensitive and rapid flow injection amperometric determination of hydrazine (N2H4). The electrodeposited Au nanoparticles on the pretreated graphite pencil electrode surface were characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray diffraction spectroscopy, and electrochemical impedance spectroscopy. Cyclic voltammograms showed that the Au nanoparticle-modified pretreated graphite pencil electrode exhibits excellent electrocatalytic activity toward oxidation of hydrazine because the highly irreversibly and broadly observed oxidation peak at +600?mV at the pretreated graphite pencil electrode shifted to ?167?mV at the Au nanoparticle pretreated graphite pencil electrode; in addition, a significant enhancement in the oxidation peak current was obtained. Thus, the flow-injection (FI) amperometric hydrazine sensor was constructed based on its electrocatalytic oxidation at the Au nanoparticle-modified pretreated graphite pencil electrode. The Au nanoparticle-modified pretreated graphite pencil electrode exhibits a linear calibration curve between the flow injection amperometric current and hydrazine concentration within the concentration range from 0.01 to 100?µM with a detection limit of 0.002?µM. The flow injection amperometric sensor has been successfully used for the determination of N2H4 in water samples with good accuracy and precision.  相似文献   

11.
By exploiting the electrostatic interaction between positively charged 3,4‐ethylenedioxythiophene cation radicals and negatively charged sulfonated graphene (SG) sheets, we prepared a poly(3,4‐ethylenedioxythiophene)‐sulfonated graphene (SG‐PEDOT) composite film by a one‐step electrochemical process. The composite was further decorated with gold nanoparticles (AuNPs) and employed as an electrode material for the detection of L ‐cysteine (Cys). The SG‐PEDOT composite film is shown to provide a rough surface for the electrodeposition of AuNPs and to improve substrate accessibility and interaction with Cys. Moreover, the AuNPs‐decorated composite exhibits better electrocatalytic performance than that of a SG‐PEDOT composite only. Under optimum experimental conditions, the amperometric current of the sensor is linearly related to the concentration of Cys in the 0.1 to 382 µM range, and the detection limit is 0.02 µM (at S/N=3). The modified electrode displays favorable selectivity, good stability and high reproducibility. The method was successfully applied to the detection of Cys in spiked human urine.  相似文献   

12.
《Electroanalysis》2017,29(9):2044-2052
This paper demonstrated using polyethylenimine (PEI)‐functionalized graphene (Gr) incorporating tin oxide (SnO2) hybrid nanocomposite as a platform for nonenzymatic H2O2 electrochemical sensor. The results of UV‐vis spectroscopy and X‐ray diffraction (XRD) confirmed the simultaneous formation of tin oxide (SnO2) nanocomposite and reduction of graphene oxide (GO). Transmission electron microscopy (TEM) images showed a uniform distribution of nanometer‐sized tin oxide nanoparticles on the grapheme sheets, which could be achieved using stannous chloride (SnCl2) complex instead of tin oxide as precursor. The electrochemical measurements, including cyclic voltammetry (CV) and amperometric performance (I‐t), showed that the PEI‐functionalized Gr supported SnO2 (SnO2‐PEI‐Gr) exhibited an excellent electrocatalytic activity toward the H2O2. The corresponding calibration curve of the current response showed a linear detection range of 9×10−6∼1.64×10−3 mol L−1, while the limit of detection was estimated to be 1×10−6 mol L−1. Electrochemical studies indicated that SnO2 and functionalized Gr worked synergistically for the detection of H2O2.  相似文献   

13.
Dopamine (DA) is a significant neurotransmitter in the central nervous system, coexisting with uric acid (UA) and ascorbic acid (AA). UA and AA are easily oxidizable compounds having potentials close to that of DA for electrochemical analysis, resulting in overlapping voltammetric response. In this work, a novel molecularly imprinted (MI) electrochemical sensor was proposed for selective determination of DA (in the presence of up to 80‐fold excess of UA and AA), relying on gold nanoparticles (Aunano)‐decorated glassy carbon (GC) electrode coated with poly(carbazole (Cz)‐co‐aniline (ANI)) copolymer film incorporating DA as template (DA imprinted‐GC/P(Cz‐co‐ANI)‐Aunano electrode, DA‐MIP‐Aunano electrode). The DA recognizing sensor electrode showed great electroactivity for analyte oxidation in 0.2 mol L?1 pH 7 phosphate buffer. Square wave voltammetry (SWV) was performed within 10?4–10?5 mol L?1 of DA, of which the oxidation peak potential was observed at 0.16 V. The limit of detection (LOD) and limit of quantification (LOQ) were 2.0×10?6 and 6.7×10?6 mol L?1, respectively. Binary and ternary synthetic mixtures of DA‐UA, DA‐AA and DA‐UA‐AA yielded excellent recoveries for DA. Additionally, DA was quantitatively recovered from a real sample of bovine serum spiked with DA, and determined in concentrated dopamine injection solution. The developed SWV method was statistically validated against a literature potentiodynamic method using a caffeic acid modified‐GC electrode.  相似文献   

14.
《Electroanalysis》2018,30(8):1642-1652
A newly developed amperometric glucose biosensor based on graphite rod (GR) working electrode modified with biocomposite consisting of poly (pyrrole‐2‐carboxylic acid) (PCPy) particles and enzyme glucose oxidase (GOx) was investigated. The PCPy particles were synthesized by chemical oxidative polymerization technique using H2O2 as initiator of polymerization reaction and modified covalently with the GOx (PCPy‐GOx) after activation of carboxyl groups located on the particles surface with a mixture of N‐(3‐dimethylaminopropyl)‐N′‐ethylcarbodiimide hydrochloride (EDC) and N‐hydroxysuccinimide (NHS). Then the PCPy‐GOx biocomposite was dispersed in a buffer solution containing a certain amount of bovine serum albumin (BSA). The resulting biocomposite suspension was adsorbed the on GR electrode surface with subsequent solvent airing and chemical cross‐linking of the proteins with glutaraldehyde vapour (GR/PCPy‐GOx). It was determined that the current response of the GR/PCPy‐GOx electrodes to glucose measured at +300 mV vs Cl reference electrode was influenced by the duration of the PCPy particles synthesis, pH of the GOx solution used for the PCPy particles modification and the amount of immobilized PCPy‐GOx biocomposite. An optimal pH of buffer solution for operation of the biosensor was found to be 8.0. Detection limit was determined as 0.039 mmol L−1 according signal to noise ratio (S/N: 3). The proposed glucose biosensor was tested in human serum samples.  相似文献   

15.
《Electroanalysis》2006,18(18):1763-1770
Poly(L ‐lactide) stabilized gold nanoparticles (designated as PLA–AuNP) with an average particle size of ca. 10 nm were used to modify a disposable screen‐printed carbon electrode (SPE) for the detection of As(III) by differential pulse anodic stripping voltammetry. Gold modification was evaluated by cyclic voltammetry, whereas scanning electron microscopy and transmission electron microscopy revealed the size and distribution of gold nanoparticles. The PLA–AuNP/SPE was applied effectively to detect toxic As(III) in HCl medium. Under the optimal experimental conditions, a linear calibration curve up to 4 ppm with a detection limit (S/N=3) of 0.09 ppb was obtained. The sensitivity was good enough to detect As(III) at levels lower than the current EPA standard (10 ppb). Most importantly, the PLA–AuNP/SPE can be tolerable from the interference of Cu, Cd, Fe, Zn, Mn, and Ni and hence provides a direct and selective detection method for As(III) in natural waters. Practical utility of the PLA–AuNP/SPE was demonstrated to detect As(III) in “Blackfoot” disease endemic village groundwater from southwestern coast area of Taiwan (Pei‐Men).  相似文献   

16.
以聚甲基丙烯酸单层保护的金纳米粒子(GNPs)作为传感器, 实现了水溶液中Pb2+的选择性循环检测.先采用柠檬酸钠还原法获得尺寸均匀的GNPs, 再通过具有硫醇端基的聚甲基丙烯酸与金的强耦合作用, 获得了聚甲基丙烯酸单层保护的金纳米粒子(PMAA-@-GNPs).动态光散射、紫外-可见吸收光谱及透射电子显微镜表征证实了其单层结构.在Pb2+的诱导下, PMAA-@-GNPs溶液颜色从酒红色变为紫色并可肉眼识别.透射电子显微镜结果证实, 这种变化是由于Pb2+交联羧基使聚合物发生收缩, 并诱导GNPs的聚集所致.对比Pb2+与Hg2+, Mg2+, Cu2+, Zn2+, Na+, Ni2+, Fe3+, Cd2+, K+和Fe2+溶液颜色的变化, 证实此体系具有一定的选择性.用EDTA可夺取交联的Pb2+, 使PMAA-@-GNPs 的吸收峰恢复并可用于循环检测Pb2+.  相似文献   

17.
采用电化学法将钯纳米粒子(PdNPs)沉积在第四代聚酰胺-胺树状大分子(G4.0 PAMAM)功能化碳纳米管(MWCNTs)复合材料(G4.0-MWCNTs)修饰的玻碳电极表面,构建了一种新型过氧化氢(H2O2)传感器。采用场发射扫描电镜、循环伏安法和电化学阻抗谱对修饰电极进行表征,结果表明,大量高分散的PdNPs沉积在G4.0-MWCNTs修饰的电极上,修饰电极对H2 O2还原具有优异的电催化性能。在优化条件下,H2 O2浓度在1.0×10-9~1.0×10-3 mol/L范围内与电流响应呈线性关系,检出限为3×10-10 mol/L (S/N=3),测定血清实样加标回收率在96.7%~103.1%之间。  相似文献   

18.
Herein, we describe a new method for the detection of hydrogen peroxide (H2O2) in food by using an electrochemical biosensor. Initially, ultrafine gold nanoparticles dispersed on graphene oxide (AuNP‐GO) were synthesized by the redox reaction between AuCl4? and GO, and thionine‐catalase conjugates were then assembled onto the AuNP‐GO surface on a glassy carbon electrode. With the aid of the AuNP‐GO, the as‐prepared biosensor exhibited good electrocatalytic efficiency toward the reduction of H2O2 in pH 5.8 acetic acid buffer. Under optimal conditions, the dynamic responses of the biosensor toward H2O2 were achieved in the range from 0.1 µM to 2.3 mM, and the detection limit (LOD) was 0.01 µM at 3sB. The Michaelis–Menten constant was measured to be 0.98 mM. In addition, the repeatability, reproducibility, selectivity and stability of the biosensor were investigated and evaluated in detail. Finally, the method was applied for sensing H2O2 in spiked or naturally contaminated samples including sterilized milk, apple juices, watermelon juice, coconut milk, and mango juice, receiving good correspondence with the results from the permanganate titration method. The disposable biosensor could offer a great potential for rapid, cost‐effective and on‐field analysis of H2O2 in foodstuff.  相似文献   

19.
This paper reports the use of a tetracycline (TC) sensor constructed from a combination of molecularly imprinted polymer (MIP) and gold nanoparticles modified multiwall carbon nanotubes (MWNTs‐GNPs). The results demonstrated that the amount of recognition sites in the polymer was significantly increased and the electron transfer ability of the sensor was improved. The relationship between the peak current and the TC concentration was linear in the range from 0.1 to 40 mg L?1, and the detection limit was 0.04 mg L?1 (S/N=3). The peak current to TC was 4.3, 6.2 and 6.8 times larger than that of oxytetracycline, chloramphenicol and nafcillin, respectively. Thus, the combination of MIP and MWNTs‐GNPs provides a sensitive and selective electrochemical detection method for tetracycline.  相似文献   

20.
A novel strategy to fabricate hydrogen peroxide (H2O2) sensor was developed by electrodepositing palladium? silver nanoparticles (NPs) on a glassy carbon electrode. The morphology of the modified electrode was characterized by Scanning electron microscopy (SEM). The result of electrochemical experiments showed that such constructed sensor had a favorable catalytic ability, high sensitivity, excellent selectivity towards reduction of hydrogen peroxide (H2O2). The response to H2O2 is linear in the range between 0.30 μM to 2.50 mM, and the detection limit is 0.1 μM (at an S/N of 3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号