首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 15 毫秒
1.
Through electrodepositing Prussian blue (PB) and chitosan (CS), then casting Pt hollow nanospheres (HN‐Pt) and assembling CA19‐9 antibody on the electrode surface, an immunosensor was achieved. A new signal amplification strategy based on PB and HN‐Pt toward the electrocatalytic reduction of H2O2 was employed when performing the determination. The resulting immunosensor showed a high sensitivity, broad linear response to carbohydrate antigen 19‐9 (CA19‐9) in two ranges from 0.5 to 30 and 30 to 240 U mL?1 with a low detection limit of 0.13 U mL?1 (S/N=3). Moreover, it displayed good reproducibility and stability, and would be potentially attractive for clinical immunoassay of CA19‐9.  相似文献   

2.
A signal‐enhanced label‐free electrochemical immunosensor was constructed by the employment of Prussian blue doped silica dioxide (PB‐SiO2) nanocomposite. At first, PB‐SiO2 nanocomposite which was produced by using a microemulsion method was used to obtain a nanostructural monolayer on a glassy carbon electrode (GCE) surface. Next amino‐functionalized interface were prepared by self‐assembling 3‐aminopropyltriethoxy silane (APTES) on the PB‐SiO2 nanoparticle surface. Then chitosan stabled gold nanoparticle (CS‐nanoAu) was subsequently attached, while the entire surface was finally loaded with neuron‐specific enolase antibody (anti‐NSE) via the adsorption of gold nanoparticle. The sensitivity of the proposed immunosensor has greatly improved as the PB‐SiO2 nanostructural sensing film provides plenty of active sites which might catalyze the reduction of H2O2. The immunosensor exhibited good linear behavior in the concentration range from 0.25–5.0 and 5.0–75 ng/mL for the quantitative analysis of neuron‐specific enolase (NSE), a putative serum marker of small‐cell lung carcinoma (SCLC), with a limit of detection of 0.08 ng/mL. The resulting NSE immunosensor showed high sensitivity and long‐term lifetime which can be attributed to the extremely high catalytic activity and biocompatibility of CS‐nanoAu/APTES/PB‐SiO2 nanostructural multilayers.  相似文献   

3.
A sensitive and specific electrochemical immunosensor was developed with α‐fetoprotein (AFP) as the model analyte by using gold nanoparticle label for enzymatic catalytic amplification. A self‐assembled monolayer membrane of mercaptopropionic acid (MPA) was firstly formed on the electrode surface through gold‐sulfur interaction. Monoclonal mouse anti‐human AFP was covalently immobilized to serve as the capture antibody. In the presence of the target human AFP, gold nanoparticles coated with polyclonal rabbit anti‐human AFP were bound to the electrode via the formation of a sandwiched complex. With the introduction of goat anti‐rabbit IgG conjugated with alkaline phosphatase, the dentritical enzyme complex was formed through selective interaction of the secondary antibodies with the colloidal gold‐based primary antibody at the electrode, thus affording the possibility of signal amplification for AFP detection. Current response arising from the oxidation of enzymatic product was significantly amplified by the dentritical enzyme complex. The current signal was proportional to the concentration of AFP from 1.0 ng mL?1 to 500 ng mL?1 with a detection limit of 0.8 ng mL?1. This system could be extended to detect other target molecules with the corresponding antibody pairs.  相似文献   

4.
In the present work, a newly functional nanoparticle has been prepared to immobilize the protein for the detection of α‐1‐fetoprotein (AFP). Prussian blue (PB) nanoparticle was initially synthesized under ultrasonic condition, then bovine serum albumin (BSA) was used to coat the PB nanoparticle to improve the stability of the PB nanoparticle as well as functionalize the surface of PB nanoparticle, and then gold colloids were loaded on the BSA‐coated PB nanoparticle to construct a core‐shell‐shell nanostructure via the conjunction of thiolate linkages or alkylamines of the BSA. Finally, a convenient, effective and sensitivity amperometric immunosensor for the detection of α‐1‐fetoprotein (AFP) was constructed by the employment of these functional core‐shell‐shell microspheres. The preparation of the nanoparticle (Au‐BSA‐PB NPs) was characterized by transmission electron microscopy (TEM), and the assembly of the biosensor was characterized with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The dynamic range of the resulted immunosensor for the detection of AFP is from 0.02 ng/mL to 200.0 ng/mL with a detection limit of 0.006 ng/mL (S/N=3). Moreover, this biosensor displays good selectivity, stability and reproducibility.  相似文献   

5.
A novel reagentless amperometric immunosensor for the determination of alpha‐fetoprotein (AFP) was prepared by immobilizing TiO2 colloids on Prussian blue (PB) modified platinum electrode, which yielded a positively charged interface with strong adsorption to deposit gold nanoparticles for immobilization of alpha‐fetoprotein antibody (anti‐AFP). The factors influencing the performance of the proposed immunosensors were studied in detail. Under the optimized conditions, cyclic voltammograms determination of AFP showed a specific response in two concentration ranges from 3.0 to 30.0 ng/mL and from 30.0 to 300.0 ng/mL with a detection limit of 1.0 ng/mL at a signal‐to‐noise ratio of 3. The proposed immunosensor exhibited high selectivity, good reproducibility, long‐term stability (>2 months) and good repeatability.  相似文献   

6.
《Electroanalysis》2017,29(9):2098-2105
An ultrasensitive electrochemiluminescence (ECL) immunosensor for the detection of tetrodotoxin (TTX) is proposed, which are composed of the branched poly‐(ethylenimine) (BPEI) functionalized graphene (BGNs)/Fe3O4‐Au magnetic capture probes and luminol‐capped gold nanocomposites (luminol‐AuNPs) as the signal tag. Herein, a typical sandwich immunecomplex was constructed on the glassy carbon electrode. The BGNs/Fe3O4‐Au hybrids could efficiently conjugate primary antibody via the Au−S chemical bonds or Au−N chemical bonds and rapidly separate under external magnetic field. The introduction of BPEI to GO could enhance the luminol‐ECL intensity. Meanwhile, the multifunctional nanocomposites have been proved with good water‐solubility, excellent electron transfer, outstanding stability, etc. The luminescent luminol‐AuNPs, a high efficient electrochemiluminescence marker, can be assembled on the second antibody, which can produce the ECL signal to achieve the determination of TTX. This proposed ECL immunosensor with a linear range from 0.01–100 ng/mL can be applied in the detection of TTX in real samples with satisfactory results.  相似文献   

7.
In this report, a label‐free electrochemical aptasensor for carcino‐embryonic antigen (CEA) was successfully developed based on a ternary nanocomposite of gold nanoparticles, hemin and graphene nanosheets (AuNPs‐HGNs). This nanocomposite was prepared by decorating gold nanoparticles on the surface of hemin functionalized graphene nanosheets via a simple wet‐chemical strategy. The aptamer can be assembled on the surface of AuNPs‐HGNs/GCE (glassy carbon electrode) through Au‐S covalent bond to form the sensing interface. Hemin absorbed on the graphene nanosheets not only acts as a protective agent of graphene sheets, but also as an in situ probe base on its excellent redox properties. Gold nanoparticles provide with both numerous binding sites for loading CEA binding aptamer (CBA) and good conductivity to promote the electron transfer. The current changes, which are caused by CEA specifically binding on the modified electrode, are exploited for the label‐free detection of CEA in a very rapid and convenient protocol. Therefore, the method has advantages of high sensitivity, wide linear range (0.0001–10 ng mL?1), low detection limit (40 fg mL?1) and attractive specificity. The results illustrate that the proposed label‐free electrochemical aptasensor has a potential application in the biological or clinical target analysis for its simple operation and low cost.  相似文献   

8.
Ni@diaza crown ether complex supported on magnetic nanoparticle was provided by grafting technique. The catalytic activity of Fe3O4@diaza crown ether@Ni was explored through one‐pot synthesis of 2,3‐dihydroquinazolin‐4(1H)‐ones and it was used as an efficient and recoverably constant nanocatalyst. FT‐IR, SEM, TEM, XRD, BET, ICP, EDS, and TGA techniques were employed to specify the nanocatalyst. This heterogeneous catalyst demonstrated acceptable recyclability and could be used again several times with no considerable loss of its catalytic activity.  相似文献   

9.
A approach was successfully employed for constructing a solid‐state electrochemiluminescence (ECL) immunosensor by layer‐by‐layer self‐assembly of multiwall carbon nanotubes (MWCNTs)‐Nafion composite film, Ru(bpy)32+/nano‐Pt aggregates (Ru‐PtNPs) and Pt nanoparticles (PtNPs). The influence of Pt nanoparticles on the ECL intensity was quantitatively evaluated by calculating the electroactive surface area of different electrodes with or without PtNPs to immobilize Ru(bpy)32+. The principle of ECL detection for target α‐fetoprotein antigen (AFP) was based on the increment of resistance after immunoreaction, which led to a decrease in ECL intensity. The linear response range was 0.01–10 ng mL?1 with the detection limit of 3.3 pg mL?1. The immunosensor exhibited advantages of simple preparation and operation, high sensitivity and good selectivity.  相似文献   

10.
In this project, Pt/NiO?GO nanocatalyst is grown on nickel foam (NF) and, its catalytic activity towards electrochemical oxidation of methanol in acidic media is studied. The first step is devoted to the synthesis of NiO?GO support by a hydrothermal method. Then Pt nanoparticles (~34.3 nm) are electrodeposited on this supporting material. Hydrothermal and electrochemical deposition conditions are optimized. Surface of modified NF was inspected for physical characterization and Chemical composition by some techniques such as field emission scanning electron microscopy (FESEM), energy‐dispersive X‐ray spectra (EDS), and X‐ray diffraction (XRD). In the electrochemical section, the catalytic performance of Pt/NiO?GO/NF towards methanol oxidation is investigated by cyclic voltammetry and chronoamperometry measurements. The electrochemical impedance spectroscopy (EIS) is elected to deliberate charge transfer resistance on the catalyst surface. Mass activity, electrochemical surface area (ECSA) and durability of prepared catalysts are compared with commercial Pt/C. Deliberations prove the superiority of Pt/NiO?GO/NF towards methanol oxidation in acidic media. The Superior quality of synthesized nanocatalyst that is attributed to the synergetic effect of the NiO?GO support material and Pt nanoparticles, indicate that Pt/NiO?GO/NF can be successfully used as the anode in the direct methanol fuel cell (DMFC).  相似文献   

11.
By the solvothermal reaction under acidic conditions of Cu(NO3)2·3H2O, Na2C2O4 and the N,N′‐ditopic organic coligands 1‐(pyridin‐4‐yl)piperazine (ppz) and 1,2‐bis(pyridin‐4‐yl)ethane (bpa), two novel anionic copper(II) coordination compounds were obtained, namely the one‐dimensional coordination polymer catena‐poly[4‐(pyridin‐1‐ium‐4‐yl)piperazin‐1‐ium [[(oxalato‐κ2O1,O2)copper(II)]‐μ‐oxalato‐κ3O1,O2:O1′]], {(C9H15N3)[Cu(C2O4)2)]}n or {(H2ppz)[Cu(C2O4)2]}n, (I), and the discrete ionic complex 4,4′‐(ethane‐1,2‐diyl)dipyridinium bis(oxalato‐κ2O1,O2)copper(II), (C12H14N2)[Cu(C2O4)2] or (H2bpa)[Cu(C2O4)2], (II). The products were characterized by single‐crystal X‐ray diffraction, elemental analysis, powder X‐ray diffraction, thermogravimetric analyses and UV and IR spectroscopic techniques. The [Cu(C2O4)2]2− units for (I) and (II) are stabilized by H2ppz2+ and H2bpa2+ cations, respectively, via charge‐assisted hydrogen bonds. Also, a study of the pH‐controlled synthesis of this system shows that (I) was obtained at pH values of 2–4. When using bpa, a two‐dimensional square‐grid network of [Cu(C2O4)(bpa)]n was obtained at a pH of 4. This indicates that the pH of the reaction also plays a key role in the structural assembly and coordination abilities of oxalate and N,N′‐ditopic coligands.  相似文献   

12.
Silk fibroin (SF) with good biocompatibility and degradability has great potential for tissue engineering. However, the SF based scaffolds lack the electroactivity to regulate the myogenic differentiation for the regeneration of muscle tissue, which is sensitive to electrical signal. Herein, a series of electroactive biodegradable scaffolds based on SF and water‐soluble conductive poly(aniline‐coN‐(4‐sulfophenyl) aniline) (PASA) via a green method for skeletal muscle tissue engineering are designed. SF/PASA scaffolds are prepared by vortex of aqueous solution of SF and PASA under physiological condition. Murine‐derived L929 fibroblast and C2C12 myoblast cells are used to evaluate cytotoxicity of SF/PASA scaffolds. Moreover, myogenic differentiation of C2C12 cells is investigated by analyzing the morphology of myotubes and related gene expression. These results suggest that electroactive SF/PASA scaffolds with a suitable microenvironment, which can enhance the myogenic differentiation of C2C12 cells, have a great potential for skeletal muscle regeneration.  相似文献   

13.
Three new compounds based on H2BDC and PyBImE [H2BDC = 1,4‐benzenedicarboxylatic acid, PyBImE = 2‐(2‐pyridin‐4‐yl‐vinyl)benzimidazole], namely, [Co(PyBImE)(BDC)(H2O)2] ( 1 ), [Co(PyBImE)2(HBDC)(BDC)0.5] ( 2 ), and [(HPyBImE)+ · (BDC)20.5 · (H2BDC)0.5] ( 3 ), were synthesized by hydrothermal methods and characterized by single‐crystal X‐ray diffraction. Compound 1 is a one‐dimensional chain bridged by terephthalate in a bis(monodentate) fashion. In the complex the nitrogen atom from NBIm and the coordination water molecule complete the coordination sphere. In complex 2 , the dinuclear cobalt units are bridged by terephthalate in a bis(bidentate) fashion into a one‐dimensional chain, but different from complex 1 , the nitrogen atom from NPy and the oxygen atom from hydrogenterephthalate complete the coordination sphere. Complex 3 is a co‐crystal with PyBImE and H2BDC in a 1:1 ratio and the transfer of hydrogen atoms leads the complex into a salt. Interesting supramolecular structures are shown due to the hydrogen bonding as well as π ··· π interactions in the three complexes. Thermal and magnetic properties of 1 and 2 were also studied.  相似文献   

14.
《Electroanalysis》2006,18(11):1091-1096
N‐(2‐Pyridyl)‐N′‐(4‐methoxyphenyl)‐thiourea (PMPT) was found to be a suitable neutral ion carrier for the construction of a highly selective and sensitive La(III) membrane sensor. Poly(vinyl chloride) (PVC) based membranes of PMPT with potassium tetrakis (p‐chlorophenyl) borate (KTpClPB) as an anionic excluder and oleic acid (OA), dibutyl phthalate (DBP), benzyl acetate (BA) and o‐nitrophenyloctyl ether (NPOE) as plasticizing solvent mediators were constructed and investigated as La(III) membrane sensors. A membrane composed of PMPT‐PVC‐KTpClPB‐BA with the ratio 8.0 : 35.0 : 3.0 : 54.0 works well over a very wide concentration range (4.0×10?8 to 1.0×10?1 M) with a Nernstian slope of 19.6±0.2 mV per decade of activity between pH values of 4.0 and 9.0. The detection limit of the sensor was calculated to be 2.0×10?8 M (ca. 3.0 ppb). The sensor displays very good discrimination toward La(III) ions with regard to most common metal ions and lanthanide ions. The proposed sensor shows a short response time for whole concentration range (ca. 12 s). For evaluation of the analytical applicability of the La(III) sensor, it was successfully used as an indicator electrode for the titration of La(III) ions with EDTA. It was also applied to the determination of fluoride content of two mouth wash preparation samples and monitoring of La(III) ions in some binary and ternary mixtures.  相似文献   

15.
Ethene homopolymerization and copolymerization with 1‐hexene were catalyzed by methyl‐substituted cyclopentadienyl (Cp) zirconium dichlorides, (Rn C5H5−n)2ZrCl2 (Rn = H, Me, 1,2‐Me2, 1,3‐Me2, 1,2,3‐Me3, 1,2,4‐Me3, Me4, or Me5), and methylaluminoxane. The polymers were characterized with Fourier transform infrared, nuclear magnetic resonance, gel permeation chromatography, and differential scanning calorimetry techniques. Generally, an increasing number of methyl substituents on the Cp ligand results in lower 1‐hexene incorporation in the copolymer. The two catalysts with split methyl substitution (Rn = 1,3‐Me2 and Rn = 1,2,4‐Me3) show a higher comonomer response than their disubstituted and trisubstituted counterparts (Rn = 1,2‐Me2 and Rn = 1,2,3‐Me3). They even incorporate more 1‐hexene than Rn = H and Rn = Me. These findings are qualitatively in agreement with the results of a theoretical study based on density functional calculations. The presence of comonomer does not influence the termination reactions after the insertion of ethene. There is more frequent termination after each hexene insertion with increasing comonomer incorporation except for the two catalysts with split methyl substituents. The termination probability per inserted comonomer is highest for the less substituted catalysts. © 2000 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 38: 3161–3172, 2000  相似文献   

16.
In this study, the electrochemical reduction of nitrite was investigated on poly(4‐aminoacetanilide) (PPAA) forming by cyclic voltammetry at the surface of carbon paste electrode. The electrochemical properties of the modified electrode have been studied by cyclic voltammetry and double potential step chronoamperometry. Results showed that in the optimum condition (pH = 0.00) the reduction of nitrite occurred at a potential about 667 mV more positive than that unmodified carbon paste electrode. This amount of electrocatalytic ability is high compared with other electrocatalysts. Using a chronoamperometric method, the catalytic rate constant (k) was calculated 8.4 × 104 cm3 mol‐1 s‐1. Also, the electrocatalytic reduction peak currents was found to be linear with the nitrite concentration in the ranges of 5 × 10‐4 M to 2.5 × 10‐2 M and 2 × 10‐5 M to 7 × 10‐3 M with detection limits (2σ) were determined as 4.5 × 10‐4 M and 1 × 10‐5 M by cyclic voltammetry (CV) and hydrodynamic amperometry methods respectively. Recovery experiments exhibit the satisfactory results.  相似文献   

17.
A membrane filtration procedure for the preconcentration and atomic absorption spectrometric determination of Pb(II), Co(II) and Fe(III) ions in natural water samples has been established. Cellulose nitrate membrane filters (0.45 μm and 47 mm diameter) were used in all experiments. The procedure is based on chelate formation of the analyte metals with 1‐(2‐pyridylazo) 2‐naphtol (PAN) and on retention of the chelates on cellulose nitrate membrane filter. The cellulose nitrate membrane and analyte ions were completely dissolved by 500 μL of nitric acid at 85 °C on a hood and then metal determinations were performed by flame atomic absorption spectrometry. The method was applied to natural water samples for the determination of analyte ions with satisfactory results, e.g., recoveries > 95%, RSD's < 10%.  相似文献   

18.
Ersin Demir 《Electroanalysis》2019,31(8):1545-1553
In the present study, desmedipham, used as an herbicide to control broad leaf weed in commonly sugar beet crops, was analyzed at the first time by cyclic voltammetry (CV) and square wave stripping voltammetry (SWSV) with the modified carbon paste electrode based on hematite nanoparticles (α‐Fe2O3?CPE). The modified α‐Fe2O3?CPE prepared by hematite (α‐Fe2O3 nanoparticles), which is very sensitive to carbon paste electrode (CPE) and glassy carbon electrode (GCE). Morphology of electrode surface detailed by scanning electron microscopy (SEM) and energy dispersive X‐ray analysis (EDX). The oxidation of desmedipham created irreversible well‐done two peaks at nearly +1.1 and +1.3 V. In order to obtain the best calibration graph, various important parameters such as pH, accumulation time, puls amplitude and frequency etc. were investigated. Under the optimum conditions, electrochemical behavior of desmedipham presented two linear working ranges at 0.15–1.20 mg/L and 1.20–4.50 mg/L. The limits of detection (LOD) for the desmedipham were calculated as 41.00 and 50.00 μg/L for the peak I and II, respectively. Furthermore, desmedipham was analyzed at high recovery in the presence of rizolex, fluometuron, teflubenzuron and some heavy metal ions. Consequently, the developed SWSV was successfully applied to evaluate desmedipham in spiked commercial strawberry juices at recoveries of 96.00–104.00 % with satisfactory relative standard deviations.  相似文献   

19.
两种[Ln(TTA)4].HP (Ln =Yb, Er)配合物被合成并表征。通过紫外可见光谱、荧光光谱、粘度和分子模拟研究了他们与DNA的键合特征。研究结果表明:它们能插入双链的DNA。更重要的是它们的荧光强度能被DNA增强,因此,一种灵敏的荧光检测DNA的方法被发展。两种配合物与质粒DNA的切割反应在凝胶电泳上展开。有意义的是,我们发现在pH=7.2 和 37℃下,两种化合物都能切割超螺旋质粒DNA。另外,我们选择BDNPP作为模型化合物进一步研究了它们对质粒DNA的切割机理,从一级动力学方程,我们间接证明可能是水解切割机理。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号