首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In our study, a method for the determination for tazarotene and betamethasone dipropionate in human tissue‐engineered skin was established. Tazarotene gel, betamethasone dipropionate cream or a combination cream was administered to the skin. Then the skin was taken off at 0.25, 0.75, 1.75, 3, 5, 8, 12, 24, 36, 48 h time points after the residual drug was removed. The concentrations of tazarotene, betamethasone dipropionate and their major metabolites in skin were determined by LC–MS. Tazarotene and tazarotenic acid were detected in the concentration range of 2–200 μg/mL with an LLOQ of 2 μg/mL. Betamethasone dipropionate was detected in the concentration range 0.5–300 μg/mL with an LLOQ of 0.5 μg/mL, and betamethasone was detected at 2–200 μg/mL with an LLOQ of 2 μg/mL. The intra‐ and inter‐day precisions of the four analytes in the skin homogenate were all <15% (RSD, %). The results showed that tazarotene could be metabolized to tazarotenic acid and betamethasone dipropionate could be metabolized to betamethasone in tissue‐engineered skin. The results also revealed that this method was suitable for the simultaneous determination of tazarotene, betamethasone dipropionate and their metabolites in tissue‐engineered skin.  相似文献   

2.
A rapid high‐performance liquid chromatography–tandem mass spectrometry method has been developed and validated for simultaneous measurement of venlafaxine and O‐desmethylvenlafaxine in human plasma using fluoxetine as an internal standard. In the liquid–liquid extraction method, compounds and internal standard were extracted from plasma using methyl tertiary butyl ether as an extraction solvent. The HPLC separation of the analytes was performed on a Zorbax SB‐C18, 50 × 4.6 mm, 5 µm column, using a isocratic elution program using a mobile phase consisting of HPLC‐grade methanol: 5 mm ammonium acetate (80:20 v/v) at a flow‐rate of 1.0 mL/min with a total runtime of 3.0 min. The proposed method has been validated with a linear range of 4–400 ng/mL for venlafaxine and 5–500 ng/mL for O‐desmethyl venlafaxine. The method was applied for a bio‐equivalence study of 75 mg tablets formulation in 32 Indian male healthy subjects under fasting conditions. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A new non‐aqueous high‐performance liquid chromatography method for the quantitative determination of mold release agent pentaerythritol tetrastearate in polycarbonate matrix has been developed and validated. The analyte calibration curve was linear over range of 0.05–0.2 mg/mL (Coefficient of determination > 0.999), with limit of detection of 0.03 mg/mL. The repeatability of method was satisfactory with relative standard deviation of 1.6%. The obtained recovery was ranging from 100–101%. Detailed high‐resolution mass spectrometric characterization of the principle peak confirmed that all the five components of pentaerythritol tetrastearate elutes as a single peak under the established chromatographic conditions. The new method is reliable and independent of any variation in composition of analyte in the samples compared to pentaerythritol tetrastearate reference standard used for calibration. The new high‐performance liquid chromatography method is robust and easy to implement in quality control laboratories for quantitative estimation of the mold release agent added in commercial polymer.  相似文献   

4.
A simple, specific, sensitive, validated method was developed using liquid chromatography with tandem mass spectrometry with electrospray ionization of human plasma for the simultaneous estimation of drugs (simvastatin, ramipril, atenolol, hydrochlorothiazide, and aspirin) of PolycapTM capsule used in cardiovascular therapy. The interaction of these actives including internal standards between the stationary and mobile phase were investigated using Hansen solubility parameters. Chromatographic separation was performed on Phenomenex Synergi Polar‐RP (30 × 2 mm, 4 μm) column with a gradient mobile phase composition of acetonitrile and 5 mM ammonium formate for positive mode and 0.1% formic acid in both water and acetonitrile for negative mode. The flow rate and runtime were 1.0 mL/min and 3.5 min, respectively. Sample extraction was done by protein precipitation using acetonitrile, enabling a fast analysis. The calibration ranges from 0.1 to 100, 0.1 to 100, and 1 to 1000 ng/mL for simvastatin, ramipril, and atenolol using internal standard carbamazepine in positive mode, respectively, whereas it was 0.3–300 and 2–2000 ng/mL for hydrochlorothiazide and aspirin using internal standard 7‐hydroxy coumarin in negative mode, respectively. Hansen solubility parameters can be used as a high‐throughput optimizing tool for column and mobile phase selection in bioanalysis. This validated bioanalytical method has the potential for future fixed dose combination based preclinical and clinical studies that can save analysis time.  相似文献   

5.
Phyllanthus species are extensively used in traditional medicines for the treatment of hepatic diseases due to their bioactive hypophyllanthin and phyllanthin. This work describes the development and validation of an ultra high performance liquid chromatography with tandem mass spectrometry method in polarity switching multiple reaction monitoring mode for the simultaneous detection and quantitation of 23 compounds using ultra‐performance liquid chromatography coupled with electrospray‐hybrid triple quadrupole‐linear ion trap mass spectrometer. The validated parameters showed good linearity (R 2 ≥ 0.996), limit of detection (0.05–1.62 ng/mL), limit of quantitation (0.15–4.95 ng/mL), precisions (intra‐day: RSD ≤ 2.11%), (inter‐day: RSD ≤ 2.91%), stability (RSD ≤ 2.56%) and overall recovery (98.22–104.48%; RSD ≤ 2.93%). The validated method was successfully applied in ethanolic extracts of P. amarus, P. niruri , P. emblica , P. fraternus , fractions of P. amarus and their herbal formulations for quantitation. The maximum content of hypophyllanthin (29.40 mg/g) and phyllanthin (56.60 mg/g) was detected in ethyl acetate fraction of P. amarus . The total content of 23 compounds was abundant in the ethanolic extract of P. emblica fruit. Principal component analysis was used to differentiate the selected Phyllanthus species and their herbal formulations. The results indicated that the present method could be used for quality control of Phyllanthus species and its herbal formulations.  相似文献   

6.
A simple and sensitive gas chromatography with tandem mass spectrometry method was developed and validated for the simultaneous determination of borneol and muscone in rat plasma. The analytes and internal standard, naphthalene, were extracted using a convenient one‐step liquid–liquid extraction method with ethyl acetate. The chromatographic separation was realized on a HP‐5MS capillary column and detected in multiple reaction monitoring mode. Excellent linearity (R 2 ≥ 0.996) was shown over 10.0–5000 ng/mL for borneol and 2.5–250 ng/mL for muscone. The lower limit of quantitation was 10 and 2.5 ng/mL for borneol and muscone, respectively. The intra‐ and interday precisions were less than 7.52%, and the accuracy values were between  −8.03 and 14.52%. The extraction recovery, matrix effect, and stability were sufficient to meet the Food and Drug Administration criteria. Meanwhile, the assay was successfully applied to the preclinical pharmacokinetic study of borneol and muscone following intravenous administration of Xingnaojing injection, a modern Chinese herbal medicine preparation.  相似文献   

7.
Most routine practices for drugs‐of‐abuse testing do not include screening procedures for new psychoactive substances, despite their increasing diffusion, preventing clear knowledge of the real consumption of these drugs in the populations. To make up for this shortcoming, a gas chromatography with mass spectrometry method was developed for the simultaneous determination of 18 synthetic cathinones and one amphetamine‐like compound in human urine. The sample preparation was based on liquid–liquid extraction under alkaline condition followed by derivatization with trifluoroacetic anhydride. The separation of the 19 analytes was achieved in less than 10 min. The whole methodology was validated according to national and international guidelines. Selectivity, linearity range, limit of detection and limit of quantitation, precision and accuracy were evaluated. For all the analytes, the calibration curve was linear in the 100–1000 ng/mL concentration range. The limits of detection ranged from 10 to 30 ng/mL and limits of quantitation from 30 to 100 ng/mL. Precisions were in the ranges 0.1–10.4%, and 1.0–12.1% for low (100 ng/mL) and high (1000 ng/mL) concentration, respectively. The accuracy, expressed as bias% was within ±20% for all the analytes. The present method was successfully applied to urine samples originating from autopsies, drug abuse/withdrawal controls, clinical investigations, roadside controls, driving re‐licensing, and workplace testing.  相似文献   

8.
A new liquid chromatography with tandem mass spectrometry method was developed and validated for the simultaneous determination of trifolirhizin, (–)‐maackiain, (–)‐sophoranone, and 2‐(2,4‐dihydroxyphenyl)‐5,6‐methylenedioxybenzofuran from Sophora tonkinensis in rat plasma using chlorpropamide as an internal standard. Plasma samples (50 μL) were prepared using a simple deproteinization procedure with 150 μL of acetonitrile containing 100 ng/mL of chlorpropamide. Chromatographic separation was carried out on an Acclaim RSLC120 C18 column (2.1 × 100 mm, 2.2 μm) using a gradient elution consisting of 7.5 mM ammonium acetate and acetonitrile containing 0.1% formic acid (0.4 mL/min flow rate, 7.0 min total run time). The detection and quantitation of all analytes were performed in selected reaction monitoring mode under both positive and negative electrospray ionization. This assay was linear over concentration ranges of 50–5000 ng/mL (trifolirhizin), 25–2500 ng/mL ((–)‐maackiain), 5–250 ng/mL ((–)‐sophoranone), and 1–250 ng/mL 2‐(2,4‐dihydroxyphenyl)‐5,6‐methylenedioxybenzofuran) with a lower limit of quantification of 50, 25, 5, and 1 ng/mL for trifolirhizin, (–)‐maackiain, (–)‐sophoranone, and 2‐(2,4‐dihydroxyphenyl)‐5,6‐methylenedioxybenzofuran, respectively. All the validation data, including the specificity, precision, accuracy, recovery, and stability conformed to the acceptance requirements. The results indicated that the developed method is sufficiently reliable for the pharmacokinetic study of the analytes following oral administration of Sophora tonkinensis extract in rats.  相似文献   

9.
A rapid and sensitive high‐performance liquid chromatography and electrospray tandem mass spectrometry method was developed and validated for estimation of fulvestrant in rabbit plasma using liquid–liquid extraction. The separation and quantification of fulvestrant were achieved by reverse‐phase chromatography on a Sunfire C18 column (50 × 2.1. i.d., 3.5 μm) with isocratic elution at a flow rate of 300 μL/min using norethistrone as an internal standard from 500 μL plasma sample. The method was validated over the concentration range from 0.092 to 16.937 ng/mL with a lower limit of detection of 0.023 ng/mL. The intra‐day and inter‐day accuracy and precision were within 10%. The recovery was 85 and 90% for fulvestrant and norethistrone respectively. The chromatographic run time was only 2.5 min. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
A reversed‐phase high‐performance liquid chromatography method was developed for the simultaneous determination of the diuretic, hydrochlorothiazide, along with six drugs representing the most commonly prescribed antihypertensive pharmacological classes such as atenolol, a selective β1 blocker, amlodipine besylate, a calcium channel blocker, moexipril hydrochloride, an angiotensin‐converting‐enzyme inhibitor, valsartan and candesartan cilexetil, which are angiotensin II receptor blockers, and aliskiren hemifumarate, a renin inhibitor, using irbesartan as an internal standard. The chromatographic separation was achieved using acetonitrile/sodium phosphate dibasic buffer (0.02 M, pH 5.5) at a flow rate of 1 mL/min in gradient elution mode at ambient temperature on a stationary phase composed of an Eclipse XDB‐C18 (4.6 × 150 mm, 5 μm) column. UV detection was carried out at 220 nm. The method was validated according to ICH guidelines. Linearity, accuracy, and precision were satisfactory over the concentration ranges of 2–40 μg/mL for hydrochlorothiazide and candesartan cilexetil, 20–120, 10–160, 5–40, 20–250, and 5–50 μg/mL for atenolol, valsartan, moexipril hydrochloride, aliskiren hemifumarate, and amlodipine besylate, respectively. The method was successfully applied for the determination of each of the studied drugs in their combined formulations with hydrochlorothiazide. The developed method is suitable for the quality control and routine analysis of the cited drugs in their pharmaceutical dosage forms.  相似文献   

11.
Topotecan (TPT) is an important anti‐cancer drug that inhibits topoisomerase I. A sensitive and robust liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method that potentially determines TPT in beagle dog plasma is needed for a bioequivalence study of TPT formulations. We developed and validated LC‐MS/MS to evaluate TPT in beagle dog plasma in terms of specificity, linearity, precision, accuracy, stability, extraction recovery and matrix effect. Plasma samples were treated with an OstroTM sorbent plate (a robust and effective tool) to eliminate phospholipids and proteins before analysis. TPT and camptothecin (internal standard) were separated on an Acquity UPLC BEH C18 column (1.7 µm, 2.1 × 50 mm) with 0.1% formic acid and methanol as the mobile phase at a flow rate of 0.25 mL/min. TPT was analyzed using positive ion electrospray ionization in multiple‐reaction monitoring mode. The obtained lower limit of quantitation was 1 ng/mL (signal‐to‐noise ratio > 10). The standard calibration curve for TPT was linear (correlation coefficient > 0.99) at the concentration range of 1–400 ng/mL. The intra‐day and inter‐day precision, accuracy, stability, extraction recovery and matrix effect of TPT were within the acceptable limits. The validated method was successfully applied in a bioequivalence study of TPT in healthy beagle dogs. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
An analytical method for the simultaneous and reliable determination of 20 antigout and antiosteoporosis pharmaceutical compounds in adulterated health food products was developed using liquid chromatography with electrospray ionization tandem mass spectrometry and liquid chromatography with quadrupole‐time‐of‐flight mass spectrometry. The method was validated through the determination of specificity, linearity, limit of detection, and limit of quantification, method detection limit, method quantitation limit, precision, accuracy, recovery, and stability. The matrix effect was also determined. The validation results of the developed method are as follows: for solid and liquid blank samples, limits of detection ranged from 0.05 to 5.00 ng/mL and limits of quantification ranged from 0.15 to 15.00 ng/mL. Linearity was acceptable, and the correlation coefficients (R2) were ≥0.99 for all target compounds. Both intra and interday precision were less than 9.16% RSD, and accuracies ranged from 95.31 to 116.68%. Mean recoveries for different types of dietary supplements classified as powders, liquids, tablets, and capsules were found to be 80.81 to 117.62% with less than 15.00% relative standard deviation. The stability of the standard mixture solution was less than 11.72% relative standard deviation after 48 h. By the proposed method, the presence of dexamethasone was determined in seized herbal food products at concentrations that ranged from 126 to 215 µg/g.  相似文献   

13.
The current work is focused on optimization, development, and validation of a sensitive and specific reversed-phase high-performance liquid chromatography (RP-HPLC) method for the estimation of rotigotine (RTG) in bulk and nanoformulations. The RP-HPLC method was effectively optimized using the concepts of design of experiments. Critical method variables (CMVs) were screened using Plackett–Burman design. Box–Behnken, a surface response methodology-based design, was further used for the optimization of CMVs with the number of theoretical plates and retention time (min) as responses. The optimized chromatographic conditions for the RP-HPLC method were: acetonitrile proportion: 54% v/v, pH of buffer: 5.0 (10 mM), and flow rate: 0.65 mL/min. The number of theoretical plates and retention time in the study were found to be 11206 and 7.65 min, respectively. The developed method exhibited good linearity (R2 = 0.9995) within a range of 25–600 ng/mL and LOD and LOQ were found to be 9 and 12 ng/mL, respectively. The developed RP-HPLC method was found sensitive, accurate, precise, specific, robust, and stability indicating according to the regulatory guidelines. The validated method was efficiently applied for in vitro dissolution study, ex vivo nasal permeation study, and estimation of drug content of RTG nanocrystals.  相似文献   

14.
A sensitive and reliable ultra‐high‐performance liquid chromatography with tandem mass spectrometry (UHPLC–MS/MS) method was developed and validated for simultaneous determination of l ‐tetrahydropalmatine (l ‐THP) and its active metabolites l ‐isocorypalmine (l ‐ICP) and L ‐corydalmine (l ‐CD) in rat plasma. The analytes were extracted by liquid–liquid extraction and separated on a Bonshell ASB C18 column (2.1 × 100 mm; 2.7 μm; Agela) using acetonitrile–formic acid aqueous as mobile phase at a flow rate of 0.2 mL/min in gradient mode. The method was validated over the concentration range of 4.00–2500 ng/mL for l ‐THP, 0.400–250 ng/mL for l ‐ICP and 1.00–625 ng/mL for l ‐CD. Intra‐ and inter‐day accuracy and precision were within the acceptable limits of <15% at all concentrations. Correlation coefficients (r ) for the calibration curves were >0.99 for all analytes. The quantitative method was successfully applied for simultaneous determination of l ‐THP and its active metabolites in a pharmacokinetic study after oral administration with l ‐THP at a dose of 15 mg/kg to rats.  相似文献   

15.
We have developed an efficient procedure and detection method using reversed‐phase high‐performance liquid chromatography for the simultaneous measurement of uracil and dihydrouracil in human plasma. The procedure, including chromatographic conditions and sample preparation, was optimized and validated. Optimization of the sample preparation included deproteinization, extraction, and cleanup. A new sample preparation method which resulted in an improved extraction yield of analytes and significantly reduced interference at low‐wavelength UV detection was developed. The developed method was validated for specificity, linearity, limits of detection and quantitation, precision, and accuracy. All calibration curves showed excellent linear regression (R 2 > 0.9990) within the testing range. The limit of detection for uracil and dihydrouracil was 2.5 and 5.0 ng/mL, respectively. The extraction yields were >94% for uracil and 91% for dihydrouracil. Intra‐ and interassay precision and accuracy for uracil and dihydrouracil were lower than 8% at all tested concentrations. The proposed method was successfully applied to measure plasma concentrations of uracil and dihydrouracil in colorectal cancer patients scheduled to receive fluoropyrimidine‐based chemotherapy.  相似文献   

16.
A novel analytical method for the simultaneous determination of the concentration of sildenafil and its five analogues in dietary supplements using solid‐phase extraction assisted reversed‐phase dispersive liquid–liquid microextraction based on solidification of floating organic droplet combined with ion‐pairing liquid chromatography with an ultraviolet detector was developed. Parameters that affect extraction efficiency were systematically investigated, including the type of solid‐phase extraction cartridge, pH of the extraction environment, and the type and volume of extraction and dispersive solvent. The method linearity was in the range of 5.0–100 ng/mL for sildenafil, homosildenafil, udenafil, benzylsildenafil, and thiosildenafil and 10–100 ng/mL for acetildenafil. The coefficients of determination were ≥0.996 for all regression curves. The sensitivity values expressed as limit of detection were between 2.5 and 7.5 ng/mL. Furthermore, intraday and interday precisions expressed as relative standard deviations were less than 5.7 and 9.9%, respectively. The proposed method was successfully applied to the analysis of sildenafil and its five analogues in complex dietary supplements.  相似文献   

17.
A rapid and sensitive liquid chromatography with tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the simultaneous determination of luteolin, luteolin‐7‐O β ‐D‐glucopyranoside, physalin A, physalin D and physalin L in rat plasma. Scutellarein and dexamethasone were used as the internal standards (IS). Plasma samples were prepared by liquid‐liquid extraction with ethyl acetate. The five constituents were separated on an Acquity UPLC BEH C18 column (100 mm × 2.1 mm, 1.7 μm). A gradient elution procedure was used with acetonitrile (A)‐0.1% aqueous formic acid (B). Mass spectrometric detection was performed in negative ion multiple reaction monitoring mode with an electrospray ionization (ESI) source. This method showed good linearity (r 2 > 0.997) over a concentration range of 2.0–500 ng/mL with a lower limit of quantification of 2.0 ng/mL for all five compounds. The inter‐ and intra‐day accuracy ranged from 91.7 to 104%, and precisions (RSD) were <6.46% for all analytes. The extraction recoveries of all analytes were >85%. This validated method was successfully applied for the first time to the pharmacokinetic study of five ingredients after oral administration of 70% ethanol extract of Chinese lantern in rats.  相似文献   

18.
A highly sensitive, rapid assay method has been developed and validated for the estimation of montelukast (MTK) in human plasma with liquid chromatography coupled to tandem mass spectrometry with electro spray ionization in the positive‐ion mode. Liquid–liquid extraction was used to extract MTK and amlodipine (internal standard, IS) from human plasma. Chromatographic separation was achieved with 10 mm ammonium acetate (pH 6.4): acetonitrile (15:85, v/v) at a flow rate of 0.50 mL/min on a Discovery HS C18 column with a total run time of 3.5 min. The MS/MS ion transitions monitored were 586.10 → 422.10 for MTK and 409.20 → 238.30 for IS. Method validation and clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.25 ng/mL and linearity was observed from 0.25 to 800 ng/mL. The intra‐day and inter‐day precisions were 5.97–8.33 and 7.09–10.13%, respectively. This novel method has been applied to a pharmacokinetic study of MTK in humans. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
A sensitive and selective liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of β,β‐dimethylacrylshikonin (DASK) in rat whole blood. DASK was pretreated using pre‐column derivatization with 2‐mercaptoethanol followed by liquid–liquid extraction with cyclohexane. Detection was performed on Thermo Finnigan TSQ Quantum triple quadrupole mass spectrometer by selected reaction monitoring mode via electrospray ionization source. The linear range for the determination of DASK spiked in rat whole blood (0.25 mL) was 3–3000 ng/mL. The accuracy was within 9%. Intra‐ and inter‐day precisions were no more than 16.1 and 13.3%, respectively. The validated LC‐MS/MS method was successfully applied to the preliminary pharmacokinetic study in rats. After DASK administration (60 mg/kg, p.o.) in rats, pharmacokinetic parameters were obtained, where the area under the drug concentration–time curve was 2393.7 ± 224.4 ng h/mL and the elimination half‐life was 27.6 ± 5.3 h. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
Bisphenol A (BPA) is an environmental endocrine‐disrupting chemicals that is widely used in common consumer products. There is an increasing concern regarding human exposure to BPA owing to the potential adverse effects associated with its estrogenic activity. For assessing environmental exposure to BPA, it is essential to have a sensitive, accurate and selective analytical method, especially one that can detect low BPA levels in complex sample matrices. In this study, we developed and validated an accurate, sensitive, and robust liquid chromatography–tandem mass spectrometry method for simultaneous quantification of free BPA and BPA β‐d ‐glucuronide (BPA‐gluc) concentrations in human urine with only a single injection. Calibration curves were linear over a concentration range of 1–100 ng/mL for BPA and 10–1000 ng/mL for BPA‐gluc. The levels of the analytes were determined quantitatively with HPLC/ESI‐MS/MS by using negative electrospray ionization in the select ion monitoring mode and a pentaflouraphenyl propyl column. The validated method was applied to the analysis of spot urine specimens collected from randomly selected healthy human subjects. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号