首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
A new flow injection chemiluminescent immunoassay was developed for the detection of 17β-estradiol (E2). The method uses p–iodophenol (PIP) as enhancer and is based on a solid-phase immunoassay format in which an E2–OVA immobilized immunoaffinity column inserted in the flow system is used to trap unbound horseradish peroxidase (HRP)-labeled anti-E2 antibody after an off-line incubation of E2 with HRP-labeled anti-E2 antibody. The trapped enzyme conjugate was detected by injecting substrates to produce an enhanced chemiluminescence (CL) response. The linear range for E2 was 10.0–1,000.0 ng mL−1 with a correlation coefficient of 0.996 and a detection limit of 3.0 ng mL−1. The sampling and chemiluminescence detection time for one sample was 400 s after a pre-incubation procedure of 30 min. Serum samples detected by this method were in good agreement with the results obtained by EIA with E2–biotin.   相似文献   

2.
 A new fluorimetric procedure for the determination of thiamine using flow injection analysis is proposed. The method is based on the derivatization reaction of the primary amine group with o-phthalaldehyde in the presence of 2-mercaptoethanol using fluorimetric detection. The calibration graph based on peak area was linear in the range 0.2–6 ng mL−1. The detection limit was close to 0.1 ng mL−1. The method was applied to the determination of the vitamin in commercial pharmaceutical preparations. Received March 31, 1999. Revision October 15, 1999.  相似文献   

3.
This work describes a new analytical procedure for trace vanadium by graphite furnace atomic absorption spectroscopy coupled to cloud point extraction (CPE) as the separation-preconcentration method. The CPE behavior of vanadium using methylene blue as complex agent and Triton X-100 as a surfactant was investigated systematically. Under the optimized conditions, the detection limit was 0.7 ng · mL−1, and the relative standard deviation was 4.3% for vanadium (c = 50.0 ng · mL−1, n = 5). The recovery of vanadium was in the range of 98.9–102.8%. The method was applied to the analysis of vanadium in certified reference materials and real samples. The results obtained were in good agreement with the certified values. Correspondence: Xiashi Zhu, Key Laboratory of Environmental Material and Environmental Engineering of Jiangsu province/College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R. China  相似文献   

4.
A polyclonal antibody against ochratoxin A (OTA) was produced from rabbits immunized with the OTA–BSA conjugate. A competitive direct enzyme-linked immunosorbent assay (cdELISA) and a membrane-base colloidal gold immunoassay in flow-through format were developed for the rapid detection of OTA in various food matrices. In the cdELISA, the concentration causing 50% inhibition was 0.07 ng mL−1, and the effects of different chemical conditions (ionic strength, pH value, and organic solvent) were studied. The sensitivity of the assay was higher than those previously reported. A simple, rapid, and efficient extraction method was developed and 74–110% recoveries of spiked samples were obtained. Fifty percent methanol extracts of some food samples such as barley, wheat, oat, corn, rice, and raisins could be analyzed directly by immunoassay after dilution in PBS; grape juice and beer samples could be analyzed directly after dilution with PBS; for coffee samples, a more complex method was used to remove the matrix effect effectively. Membrane-based colloidal gold immunoassays had a visual detection limit of 1.0 ng mL−1 for OTA with a detection time of less than 10 min. For the validation of the cdELISA and membrane-based colloidal gold immunoassay, samples were analyzed by high-performance liquid chromatography. The correlation between data obtained using the microwell assay and HPLC was good (R 2 = 0.984). The developed immunoassay methods are suitable for the rapid quantitative or qualitative determination of OTA in food samples.  相似文献   

5.
A flow injection chemiluminescence method is proposed for the determination of cobalt, based on the strong catalytic effect of Cobalt(II) (1,10-phenanthroline)3 complex on the lucigenin-periodate reaction in alkaline medium. Under the optimum experimental conditions, the chemiluminescence signal responded linearly to the concentration of cobalt(II) in the 1.0 × 10−9–3.0 × 10−7 g mL−1 range with a detection limit of 4.4 × 10−10 g mL−1 cobalt(II). The relative standard deviation for the determination of 5.0 × 10−8 g mL−1 of cobalt was 2.3% in eleven replicated measurements. The method was successfully applied to the determination of cobalt(II) in pharmaceutical preparations.  相似文献   

6.
Proteins from the Cry 1 family, in particular Cry 1Ab, are commonly expressed in genetically modified Bt maize in order to control chewing insect pests. A sensitive chemiluminescent sandwich enzyme immunoassay for the detection of Cry1Ab protein from genetically modified Bt maize has been developed and validated. A Cry1Ab protein-specific antibody was immobilized on 96- or 384-well microtiter plates in order to capture the Cry1Ab toxin in the sample; the bound toxin was then detected by employing a second anti-Cry1Ab antibody and a horseradish peroxidase-labeled anti-antibody, followed by measurement of the enzyme activity with an enhanced chemiluminescent system. The chemiluminescent assay fulfilled all the requirements of accuracy and precision and exhibited limits of detection of a few pg mL−1 Cry1Ab (3 or 5 pg mL−1, depending on the assay format), which are significantly lower than that achievable using conventional colorimetric detection of peroxidase activity and also represent an improvement compared to previously developed Cry1Ab immunoassays. High-throughput analysis can be performed using the 384-well microtiter plate format immunoassay, which also allows one to reduce the consumption of samples and reagents. Validation of the assay, performed by analyzing certified reference materials, proved that the immunoassay is able to detect the presence of the Cry1Ab protein in certified reference samples containing as low as 0.1% of MON 810 genetically modified Bt maize. This value is below the threshold requiring mandatory labeling of foods containing genetically modified material according to the actual EU regulation.  相似文献   

7.
A micro-magnetic chemiluminescence (CL) enzyme immunoassay with high sensitivity, selectivity, and reproducibility was developed for the determination of the tumor marker, carcinoembryonic antigen (CEA) in human serum. A sandwich scheme assay has been utilized with fluorescein isothiocyanate antibody (FITC)-labeled anti-CEA antibody and alkaline phosphate (ALP)-labeled anti-CEA antibody being used in the CL detection. The CL signal produced by the emission of photons from 4-methoxy-4-(3-phosphate-phenyl)-spiro-(1,2-dioxetane-3,2′-adamantane) (AMPPD) was directly proportional to the amount of analyte present in a sample solution. The influences of the reaction time of antigen with antibody, the reaction time of substrate with label, the dilution ratio of ALP-labeled anti-CEA antibody, the concentration of FITC-labeled anti-CEA antibody, and other relevant variables upon the CL signal were examined and optimized. The CL responses depended linearly on the CEA concentration over the range from 2 to 162 ng mL−1 in a logarithmic plot. Assay sensitivity as low as 0.69 ng mL−1 was achieved. A coefficient of variance of less than 13% was obtained for intra- and inter-assay precision. This method has been successfully applied to the analysis of CEA in human serum. According to the procedure based on spiked standards, the recoveries obtained were 80–110%. Comparison experiments were carried out with the commercially available CEA chemiluminescence immunoassay. Satisfactory results were obtained according to a paired t-test method (t value < t critical at the 95% confidence level).  相似文献   

8.
A novel molecularly imprinted polymer solid-phase extraction (MISPE) with flow-injection chemiluminescence (CL) was developed for the determination of pazufloxacin mesilate (PZFX). The molecularly imprinted polymer (MIP) was synthesized by using PZFX as the imprinting molecule. A glass tube packed the particles of the MIP was employed as MISPE micro-column, which was connected into the sampling loop of the eight-way injection valve for on-line selective preconcentration and extraction of PZFX. The eluent of acetonitrile:acetic acid (9:1, v:v) was used as carrier for eluting the adsorbed PZFX to react with the mixture of cerium(IV) and sodium sulfite in the flow cell to produce strong CL. The relative intensity of CL was linear to PZFX concentration in the range from 2.5 × 10−9 to 2.5 × 10−7 g mL−1. The limit of detection was 7 × 10−10 g mL−1 (3 σ) and the relative standard deviation for 5 × 10−8 g mL−1of PZFX solution was 3.7% (n = 7). This method has been applied to the determination of PZFX in human urine.  相似文献   

9.
A new chemiluminescence (CL) method combined with flow injection technique is described for the determination of Cr(III) and total Cr. It is found that a strong CL signal is generated from the reaction of Cr(III), lucigenin and KIO4 in alkaline condition. The determination of total Cr is performed by pre-reduction of Cr(VI) to Cr(III) by using H2SO3. The CL intensity is linearly related to the concentration of Cr in the range 4.0 × 10−10–1.0 × 10−6 g mL−1. The detection limit (3s b) is 1 × 10−10 g mL−1 Cr and the relative standard deviation is 1.9% (5.0 × 10−8 g mL−1 of Cr(III) solution, n = 11). The method was applied to the determination of Cr(III) and total Cr in water samples and compared satisfactorily with the official method.  相似文献   

10.
Chitosan resin functionalized with 3,4-dihydroxy benzoic acid (CCTS-DHBA resin) was used as a packing material for flow injection (FI) on-line mini-column preconcentration in combination with inductively coupled plasma-atomic emission spectrometry (ICP-AES) for the determination of trace elements such as silver, bismuth, copper, gallium, indium, molybdenum, nickel, uranium, and vanadium in environmental waters. A 5-mL aliquot of sample (pH 5.5) was introduced to the minicolumn for the adsorption/preconcentration of the metal ions, and the collected analytes on the mini-column were eluted with 2 M HNO3, and the eluates was subsequently transported via direct injection to the nebulizer of ICP-AES for quantification. The parameters affecting on the sensitivity, such as sample pH, sample flow rate, eluent concentration, and eluent flow rate, were carefully examined. Alkali and alkaline earth metal ions commonly existing in river water and seawater did not affect the analysis of metals. Under the optimum conditions, the method allowed the determination of metal ions with detection limits of 0.08 ng mL−1 (Ag), 0.9 ng mL−1 (Bi), 0.07 ng mL−1 (Cu), 0.9 ng mL−1 (Ga), 0.9 ng mL−1 (In), 0.08 ng mL−1 (Mo), 0.09 ng mL−1 (Ni), 0.9 ng mL−1 (U), and 0.08 ng mL−1 (V). By using 5 mL of sample solution, the enrichment factor and collection efficiency were 8–12 fold and 96–102%, respectively, whereas the sample throughput was 7 samples/hour. The method was validated by determining metal ions in certified reference material of river water (SLRS-4) and nearshore seawater (CASS-4), and its applicability was further demonstrated to river water and seawater samples.  相似文献   

11.
The electrochemical behavior of the ofloxacin–copper complex, Cu(II)L2, at a mercury electrode, and the interaction of DNA with the complex have been investigated. The experiments indicate that the electrode reaction of Cu(II)L2 is an irreversible surface electrochemical reaction and that the reactant is of adsorbed character. In the presence of DNA, the formation of the electrochemically non-active complexes Cu(II)L2-DNA, results in the decrease of the peak current of Cu(II)L2. Based on the electrochemical behavior of the Cu(II)L2 with DNA, binding by electrostatic interaction is suggested and a new method for determining nucleic acid is proposed. Under the optimum conditions, the decrease of the peak current is in proportional to the concentration of nucleic acids in the range from 3 × 10−8 to 3 × 10−6 g · mL−1 for calf thymus DNA, from 1.6 × 10−8 to 9.0 × 10−7 g · mL−1 for fish sperm DNA, and from 3.3 × 10−8 to 5.5 × 10−7 g · mL−1 for yeast RNA. The detection limits are 3.3 × 10−9, 6.7 × 10−9 and 8.0 × 10−9 g · mL−1, respectively. The method exhibits good recovery and high sensitivity in synthetic samples and in real samples.  相似文献   

12.
A simple flow injection chemiluminescence (CL) method was developed for the determination of atenolol using Eu3+ as the probe. It was found that the weak CL generated by the KMnO4-Na2SO3 reaction can be significantly enhanced by the atenolol-Eu3+ complex. The experimental conditions were optimized. The CL intensity was linearly related to atenolol concentration in the range from 8.0 × 10−9 to 1.0 × 10−5 g mL−1. The detection limit (3s b) was 3 × 10−9 g mL−1 and the relative standard deviation for 1.0 × 10−7 g mL−1 atenolol solution was 2.4% (n = 11). The method has high sensitivity, wide linear range, inexpensive instrumentation, and has been applied to the determination of atenolol in spiked human urine and plasma samples with recoveries within the range 95.5–104.0%. Supplementary material to this paper is available in electronic form at Electronic supplementary material: Discussion of the reaction mechanism and additional figures are available online as electronic supplementary material (ESM) at . Correspondence: Jianxiu Du, Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Materials Science, Shaanxi Normal University, Xi’an 710062, P.R. China  相似文献   

13.
Analytical methods for determining both dihydrozeatin (DHZ) and dihydrozeatin riboside (DHZR) are optimized via voltammetric anodic stripping using a carbon fiber microelectrode, working in 0.05 M AcH/Ac buffer pH 4.0, previously accumulated at 0.00 V (vs. Ag/AgCl/ KCl 3 M) for 400 s, at a scan rate of 800 mV · s–1. A detection limit of 40.0 ng · mL–1 and a determination limit of 46.0 ng · mL–1 for the DHZ are obtained. Using the same supporting electrolyte and accumulation potential conditions, but for periods of 70 s and carrying out a stripping scan rate of 900 mV s–1, the detection limit calculated for the DHZR was 14.0 ng · mL–1 and the determination limit obtained was 153 ng · mL–1. The proposed methods were successfully applied to determine minute amounts of cytokinins in apples during their growth period. Received: 22 July 1998 / Revised: 9 December 1998 / Accepted: 14 December 1998  相似文献   

14.
A method based on cloud point extraction (CPE) separation/preconcentration of trace cadmium as a prior step to its determination by graphite furnace atomic absorption spectrometry (GFAAS) has been developed. If the system temperature is higher than the cloud point temperature (CPT) of the nonionic surfactant of p-octyl polyethyleneglycolphenyether (Triton X-100), the complex of Cd2+ with 1-(2-pyridylazo)-2-naphthol (PAN) could be extracted into surfactant-rich phase. The chemical variables affecting CPE were evaluated and optimized. Under the optimum conditions, preconcentrating 10.0 mL of water samples permitted a limit of detection of 5.9 ng · L−1 (3σ) for cadmium with an enhancement factor of 50 and a relative standard deviation of 2.1% (n = 11, c = 2.0 ng · mL−1). The method was applied to the determination of cadmium in reference material and water samples with satisfactory results.  相似文献   

15.
Immunosenors are of great interest because oftheir potential utility as specific, simple, label-free anddirect detection techniques and reductions in size, costand time of analysis compared with conventional im-munoassay techniques. The immunoassays with …  相似文献   

16.
This work reported for the first time the use of flow injection electrochemiluminescence (FI-ECL) sensor for the determination of durabolin in an aqueous system based on CdTe quantum dot (QD) films. Aqueous CdTe colloidal solutions were prepared using thioglycolic acid as a capping agent. Zetasizer Nano ZS (Malvern, UK) was employed to characterize the size of CdTe QDs. The UV–vis and photoluminescence spectra of samples were systematically characterized. Indium tin oxide (ITO) slide glass was modified with CdTe QDs by layer-by-layer self-assembly. CdTe QD films were packed into a homemade cell and used as a recognizer of the FI-ECL sensor to determine durabolin. The intensive anodic ECL emission was obtained at a starting potential of +1.3 V (vs. Ag/AgCl) in a carbonate bicarbonate buffer solution with a pH of 9.93 at an ITO electrode. The ECL intensity was correlated linearly with the concentration of durabolin over the range of 1.0 × 10−8–1.0 × 10−5 g mL−1, and the detection limit was 2.5 × 10−9 g mL−1. The relative standard deviation for the determination of 1.0 × 10−6 g mL−1 durabolin was 1.04% (n = 11). This simple and sensitive sensor revealed good reproducibility for ECL analysis. As a result, the new FI-ECL sensor had been successfully applied to the determination of durabolin in food samples. This strategy could be easily realized and opened new avenues for the applications of QDs in ECL biosensing.  相似文献   

17.
 A selective, sensitive and simple catalytic method is developed for the determination of vanadium in natural and highly polluted waste waters. The method is based on the catalytic effect of VV and/or VIV on the bromate oxidative-coupling reaction of metol with phloroglucinol (PG). The reaction is followed spectrophotometrically by tracing the oxidation product at 464 nm after 10 minutes of mixing the reagents. The optimum reaction conditions are metol (8.0×10−3 M), PG (4.0×10−3 M) and bromate (2×10−2 M) at 35°C and in presence of an activator-b uffer mixture of 5×10−2 M of each of citric and monochloroacetic acids (pH 2.40). Following the recommended procedure, vanadium can be determined with a linear calibration graph up to 8.0 ng mL−1 and a detection limit, based on the 3sb criterion, of 0.1 ng mL−1. Spectrophotometric determination of as little as 1.0 ng mL−1 of VV or VIV in aqueous solutions gave an average recovery of 98% with relative standard deviations of ?1.8% (n = 5). The proposed method was directly applied to the determination of vanadium in Nile river water and highly polluted industrial wastes. Statistical treatments of analytical results could not detect any systematic error and showed the high accuracy and precision of the developed method. Received November 25, 1999. Revision March 10, 2000.  相似文献   

18.
A flow injection–solid-phase spectroscopy (FI-SPS) system implemented with photochemically induced fluorescence (PIF) is described for the rapid and very sensitive determination of reserpine in biological fluids and pharmaceutical formulations. An intensively fluorescent photoproduct is in-line generated, retained on C18 silica gel in the detection area and monitored at 394/489 nm (λ ex/λ em). After the establishment of the appropriate working variables, the system is calibrated at two different injection volumes, 100 and 800 μL, achieving detection limits of 0.33 and 0.05 ng mL−1, respectively. The RSD for reserpine at 2 ng mL−1 (800 μL) was 1.5% (n = 10). The sampling rates were 46 and 43 h−1 for each injection volume, respectively. The potential interference of some common species coexisting with reserpine in the analysed samples was also studied. The procedure was successfully applied to commercial formulations, urine and serum without any previous treatment of samples. Recoveries ranged from 94.9 to 100.2%.  相似文献   

19.
A multianalyte lateral-flow immunochromatographic technique using colloidal gold-labeled polyclonal antibodies was developed for the rapid simultaneous detection of clenbuterol and ractopamine. The assay procedure could be accomplished within 5 min, and the results of this qualitative one-step assay were evaluated visually according to whether test lines appeared or not. When applied to the swine urines, the detection limit and the half maximal inhibitory concentration (IC50) of the test strip under an optical density scanner were calculated to be 0.1 ± 0.01 ng mL−1 and 0.1 ± 0.01 ng mL−1, 0.56 ± 0.08 ng mL−1, and 0.71 ± 0.06 ng mL−1, respectively, the cut-off levels with the naked eye of 1 ng mL−1 and 1 ng mL−1 for clenbuterol and ractopamine were observed. Parallel analysis of swine urine samples with clenbuterol and ractopamine showed comparable results obtained from the multianalyte lateral-flow test strip and GC-MS. Therefore, the described multianalyte lateral-flow test strip can be used as a reliable, rapid, and cost-effective on-site screening technique for the simultaneous determination of clenbuterol and ractopamine residues in swine urine.   相似文献   

20.
An HPLC method was developed and validated for the determination of the cephalosporins cefotaxime and cephalexine in skimmed bovine milk. The analytical column, Kromasil C18 (250 mm × 4.0 mm, 5 μm) was operated at ambient temperature. Mobile phase consisted of CH3OH-acetate buffer (pH = 4.0) and it was delivered isocratically at a flow rate of 1.0 mL · min−1. Total analysis time was less than 5 min. Caffeine was used as internal standard (5 ng · μL−1). UV detection was performed at 265 nm. Method validation was performed by means of intra-day (n = 5) and inter-day accuracy and precision (n = 8), sensitivity and linearity. Limits of detection (LOD) and limits of quantification (LOQ) were 0.1 and 0.3 ng · μL−1, respectively. The method was applied to the analysis of a veterinary drug (CEPOREX) containing cephalexine. The results were quite accurate with the relative error varying from −8.0 to −3.5%. Solid-phase extraction was applied to remove all matrix interference from milk samples. High extraction recoveries (average 84–121%) were achieved by using Abselut NEXUS cartridges with acetonitrile as eluent and a rinsing step with water and n-butanol. A pre-concentration step was necessary in a 1/10 level to reach the EU MRL concentration level (100 μg · kg−1). RSD values were less than 7% for both cephalosporins. Correspondence: Ioannis N. Papadoyannis, Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号