首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Determination of phospholipids in dairy products by SPE/HPLC/ELSD   总被引:10,自引:0,他引:10  
The aim of this work was to evaluate the performance of different methods for both milk lipid extraction and phospholipids separation. As far as the lipid extraction procedure is concerned, the Folch method showed a higher phospholipid recovery with respect to the Rose-Gottlieb method. Different SPE cartridges and solvent phases were tested to carry out the separation of phospholipids from fat. The yield of extraction was evaluated by isolating phospholipids from both milk fat and synthetic fat; Standard Addition Method was applied as well. The isolation of the phospholipids by SPE silica column and subsequent analysis by HPLC/ELSD was shown to be an accurate and reproducible analytical method for the determination of phosphatidylethanolamine, phosphatidylinositol, phosphatidylserine, phosphatidylcholine and sphingomyelin in milk fat extracted by Folch method.  相似文献   

2.
Phospholipids possess important physiological, structural and nutritional functions in biological systems. This study described a solid-phase extraction (SPE) method, employing graphene and titanium dioxide (G/TiO2) nanocomposite as sorbent, for the selective isolation and enrichment of phospholipids from avocado (Persea americana Mill.). Based on the principal that the phosphoryl group in the phospholipid can interact with TiO2 via a bridging bidentate mode, an optimum condition was established for SPE, and was successfully applied to prepare avocado samples. The extracts were monitored by matrix-assisted laser desorption ionization time-of-flight/tandem mass spectrometry (MALDI-TOF/MS) in both positive-ion and negative-ion modes. Results showed that phospholipids could be efficiently extracted in a clean manner by G/TiO2 based SPE. In addition, the signals of phospholipids were enhanced while the noise was reduced. Some minor peaks became more obvious. In conclusion, the nanocomposite material of G/TiO2 was proved to be a promising sorbent for selective separation of phospholipids from crude lipid extract.  相似文献   

3.
A new method for the analysis of phospholipids by normal-phase HPLC is described using a silica column. Addition of ammonia and triethylamine to a gradient based on chloroform/methanol/water promoted a good and rapid separation of phospholipid classes (20 min run). The use of an evaporative light scattering detector permitted an accurate analysis of a mixture of phospholipids. Calibration curves were linear within different range for each phospholipid class. The LOD and LOQ obtained were below 0.03 and 0.05 mg kg−1 for all cases, respectively. Besides, a new method for the separation of phospholipids from total lipids before HPLC analysis by a solid-phase extraction (SPE) with Si cartridges has been developed. This methodology gave a good recovery ranging from 97 to 117%. The method was validated with a standard mixture of phospholipids. This method has been applied to characterize the phospholipid fraction of subcutaneous fat from Iberian pig. Cardiolipin, phosphatidylethanolamine, phosphatidylinositol, phosphatidylserine, phosphatidylcholine, and sphingomyelin have been described for first time in these samples. The fatty acid composition of the different phospholipid classes and their HPLC electrospray ionization mass spectrometry have been used for characterizing the molecular species present in each one.  相似文献   

4.
A new preparation scheme is proposed to fractionate neutral lipids (acylglycerines, sterol esters, long-chain free fatty acids) from polar phospholipids in biological matrices. This fractionation is mandatory in the microbial community, for the control of bioremediation processes, in the study of phytoplankton growth in lakes and rivers, and in the quality control of processed food. Basically, a two-step pressurized liquid extraction (PLE) scheme is combined with an "in-cell-fractionation" using silica-based sorbents placed at the outlet of the PLE cartridge. The optimized extraction scheme consists of n-hexane/acetone (9:1, v/v) extraction at 50 degrees C (2 cycles, 10 min each) to obtain neutral lipids followed by chloroform/methanol (1:4, v/v) extraction at 110 degrees C (2 cycles, 10 min each). Thermally pre-treated silicic acid and cyanoproyl-modified silica turned out to be appropriate sorbents to ensure clear-cut boundaries between neutral lipids and phospholipids. The proposed protocol is superior to commonly used approaches consisting of an exhaustive lipid extraction followed by off-line lipid fractionation using solid-phase extraction (SPE) regarding fractionation efficiency, time and solvent consumption. In this paper, it is also shown that the transmethylation using trimethylchlorosilane/methanol (1:9, v/v) provides a complete reaction to give methyl esters without artefact formation across the array of different lipid classes even with polyunsaturated fatty acid moieties.  相似文献   

5.
赵海香  刘海萍  闫早婴 《色谱》2014,32(3):294-298
建立了多壁碳纳米管为吸附剂的固相萃取净化-高效液相色谱-紫外检测测定猪肉和鸡肉中多种磺胺类药物多残留的方法。样品采用乙腈提取,多壁碳纳米管固相萃取净化,NaH2PO4缓冲溶液(pH 5.5~6.0)溶解上样,5%(v/v)丙酮-正己烷淋洗,丙酮-二氯甲烷(1:1,v/v)洗脱。色谱分离以50 mmol/L NaH2PO4-乙腈(7:3,v/v)为流动相,方法的线性范围为0.01~1.00 mg/L,线性相关系数大于0.998,检出限(LOD)为0.003 mg/L,定量限(LOQ)为0.01 mg/L。在0.02~0.2 mg/kg添加范围内,9种磺胺类药物的回收率高于70%,RSD低于8%,表明多壁碳纳米管对磺胺类药物具有较强的吸附富集能力。该方法简便、准确可用于动物组织及产品中磺胺药物残留的检测。  相似文献   

6.
周健  陈晓红  金米聪 《色谱》2022,40(4):303-312
建立了分散固相萃取-超快速液相色谱-串联质谱法同时测定板栗粉和小麦粉中43种真菌毒素的方法,对48份板栗粉和80份小麦粉样品的污染状况进行调查,筛选出5种专属于小麦粉的标志性真菌毒素.样品采用84%(v/v)乙腈水溶液提取,提取液采用C18结合增强型脂质去除净化剂(EMR-Lipid)净化,采用响应曲面-中心组合设计优...  相似文献   

7.
This work reports an efficient and universal SPE method developed for separation and identification of phospholipids derived from complex biological samples. For the separation step, sequential combination of silica gel‐aminopropyl‐silica gel SPE cartridges is applied. This setup enables separation of phosphatidylcholine, lysophosphatidylcholine, phosphatidylethanolamine, phosphatidylglycerol, phosphatidic acid, phosphatidylinositol, phosphatidylserine, cardiolipin, and sphingomyelin into four fractions according to the polarity of their headgroups. Sample acquisition of the SPE fractions is performed by a high‐resolution LC‐MS system consisting of a hybrid linear IT Fourier transform ion cyclotron resonance mass spectrometer coupled to RP‐HPLC. The unequivocal advantage of our SPE sample preparation setup is avoidance of analyte peak overlapping in the determination step done by RP‐HPLC. Overlapping phospholipid signals would otherwise exert adverse ion suppression effects. An additional benefit of this method is the elimination of polar and nonpolar (e.g. neutral lipids) contaminants from the phospholipid fractions, which highly reduces contamination of the LC‐MS system. The method was validated with fermentation samples of organic waste, where 78 distinct phospholipid and sphingomyelin species belonging to six lipid classes were successfully identified.  相似文献   

8.
The quantification of phospholipid classes and the determination of their molecular structures are crucial in physiological and medical studies. This paper's target analytes are cell membrane phospholipids, which play an important role in the seasonal acclimation processes of poikilothermic organisms. We introduce a set of simple and cost‐effective analytical methods that enable efficient characterization and quantification of particular phospholipid classes and the identification and relative distribution of the individual phospholipid species. The analytical approach involves solid‐phase extraction and high‐performance thin‐layer chromatography, which facilitate the separation of particular lipid classes. The obtained fractions are further transesterified to fatty acid methyl esters and subjected to gas chromatography coupled to flame ionization detection, which enables the determination of the position of double bonds. Phospholipid species separation is achieved by high‐performance liquid chromatography with mass spectrometry, which gives information about the headgroup moiety and attached fatty acids. The total content of each phospholipids class is assessed by phosphorus determination by UV spectrophotometry. The simultaneous analysis of phosphorus, fatty acid residues, and phospholipid species provides detailed information about phospholipid composition. Evaluation of these coupled methods was achieved by application to an insect model, Pyrrhocoris apterus. High correlation was observed between fatty acid compositions as determined by gas chromatography and high‐performance liquid chromatography analysis.  相似文献   

9.
A high-performance liquid chromatographic method with electrochemical detection (HPLC-ED) at a boron-doped diamond film electrode with preliminary separation and preconcentration by solid-phase extraction (SPE) has been developed for the determination of 1-hydroxypyrene (1-HP) in human urine. 1-HP is among the most widely used biomarkers of exposure to polycyclic aromatic hydrocarbons. Optimal HPLC-ED conditions have been found: mobile phase methanol-0.05 mol L(-1) phosphate buffer pH 5.0 (80:20, v/v), detection potential +1,000 mV versus Ag/AgCl (3 mol L(-1) KCl), and flow rate 0.8 mL min(-1). For SPE, LiChrolut(?) RP-18 E cartridges were used. The extraction yield was (87.0 ± 5.8)% (n = 5). The concentration dependence of 1-HP was measured in the concentration range from 0.01 to 10 μmol L(-1) (2.18-2,180 μg L(-1)) using methanolic solutions resulting from the SPE pretreatment of spiked human urine samples. The limit of detection (signal-to-noise ratio 3) and the limit of quantification (signal-to-noise ratio 10) of the biomarker were 0.013 μmol L(-1) (2.84 μg L(-1)) and 0.043 μmol L(-1) (9.39 μg L(-1)), respectively, which is sufficient for its determination in the urine of persons exposed to polycyclic aromatic hydrocarbons.  相似文献   

10.
A new, simple and rapid capillary electrophoresis-mass spectrometry (CE-MS) method, using a cationic polymer-coated capillary to reverse electroosmotic flow, is proposed and validated for the separation and simultaneous quantification of 11 gibberellins (GAs). Under optimum conditions, a baseline separation of 11 GAs, including GA1, GA3, GA4, GA5, GA6, GA7, GA13, GA19, GA20, GA24 and GA53 was accomplished within 25 min using 70 mM ammonium formate/formic acid buffer (pH 3.8) and 2% (v/v) acetonitrile with -25 kV as the separation voltage. Satisfactory results were obtained in terms of linearity (R2 between 0.984 and 0.995), precision (RSD of migration time below 0.8%) and sensitivity (LOD between 0.31 and 1.02 microM). Furthermore, a novel solid-phase extraction (SPE) procedure was developed for the pre-concentration and purification of GAs using Oasis MAX cartridges. The combination of SPE and CE-MS approach was applied to screen for endogenous GAs present in coconut (Cocos nucifera L.) water sample. To illustrate the applicability of the method, GA1 and GA3 were successfully detected and quantified in coconut water. Finally, the GA1 and GA3 identities were further unequivocally confirmed by CE-tandem MS experiments operating in the multiple reaction monitoring mode.  相似文献   

11.
潘胜东  童廷德  叶美君  陈晓红  金米聪 《色谱》2019,37(12):1321-1330
建立了固相萃取-超高效液相色谱-高分辨质谱(UPLC-HRMS)快速准确测定面粉和燕麦中残留草甘膦(GLY)及其代谢物氨甲基膦酸(AMPA)的分析方法。面粉和燕麦样品经水涡旋和超声提取,用混合阳离子交换固相萃取(MCX)小柱净化与乙腈沉淀蛋白质后,以5 mmol/L乙酸铵水溶液(pH=10.5)和乙腈溶液作为流动相在Dikma Polyamino HILIC色谱柱(150 mm×2.0 mm,5 μm)上进行梯度洗脱与分离,采用电喷雾电离源、负离子模式和平行反应监测(PRM)模式下,内标法定量分析。系统优化了液相色谱与高分辨质谱等仪器条件和样品前处理条件对GLY及其代谢物AMPA测定的影响,并比对了不同分析方法的基质效应,研究了进样系统残留。实验结果表明,GLY和AMPA在5.0~100.0 μg/L范围内呈现良好的线性关系(线性相关系数R2>0.999),检出限分别为0.005和0.05 mg/kg;低(0.1 mg/kg)、中(0.5 mg/kg)、高(2.0 mg/kg)3个添加水平下,GLY和AMPA的加标回收率分别为93.8%~115%和89.8%~110%,相对标准偏差均小于10%。基质效应实验结果表明,利用同位素内标物能有效降低方法的基质抑制效应(基质效应参数|η|<3%);进样系统的残留率小于1.0%。本方法与文献报道的衍生化法方法进行比对,结果表明,两种检测方法与靶值的相对偏差分别为2.19%和3.07%。将该方法用于弗帕斯(FAPAS)能力验证样品的测定(编号为09122,燕麦中GLY的测定),结果满意,测定值与真值之间的偏离程度(z值)=0.2。FAPAS质控样品(编号为T09119QC,面粉中GLY的测定)检测结果显示本方法的准确度为102.2%。该方法具有快速、简便、灵敏和准确等优点,适合面粉与燕麦样品中GLY及其代谢物AMPA的日常监测。  相似文献   

12.
李兵  刘伟  范赛  赵榕  吴国华 《色谱》2012,30(6):584-589
采用固相萃取净化结合超高效液相色谱-串联质谱法(UPLC-MS/MS)测定了螺旋藻保健品中7种微囊藻毒素(MCs)。螺旋藻保健品经70%(体积分数)的甲醇超声提取,冷冻离心沉淀杂质后,经HLB柱净化。在Waters ACQUITY UPLCBEH C18色谱柱上以乙腈和0.2 mmol/L乙酸铵水溶液为流动相进行梯度洗脱分离,采用电喷雾离子源正离子模式进行多反应离子监测,外标法定量。7种MC在线性范围内线性关系良好(相关系数(r)不小于0.995);检出限为6.7~33.3 μg/kg,定量限为20.0~100.0 μg/kg。各分析物在阴性螺旋藻保健品中的加标回收率在87.5%~97.9%之间,相对标准偏差(RSD)在1.6%~6.9%之间。该方法准确可靠,灵敏度高,可用于螺旋藻保健品中MC污染的确证定性、定量检测。  相似文献   

13.
Determination of the individual fatty acid composition of neutral- and phospholipids as well as the phospholipid content of dairy food and other foodstuffs are important tasks in life sciences. For these purposes, a method was developed for the separation of lipids (standards of triolein and diacylphosphatidylcholines as well as three cheese samples) by solid-phase extraction using a self-packed column filled with partly deactivated silica. Non-halogenated solvents were used for the elution of the lipid classes. Cyclohexane/ethyl acetate (1:1, v/v) served for the elution of neutral lipids, while polar lipids were eluted with three solvents (ethyl acetate/methanol, methanol, and methanol/water) into one fraction. The separated lipid fractions were transesterified and the individual fatty acids were quantified by using gas chromatography coupled to electron ionization mass spectrometry (GC/EI-MS) in the selected ion monitoring (SIM) mode. The recovery rate for standard phosphatidylcholines was ∼90% and cross-contamination from neutral lipids was negligible. The method was applied to cheese samples. Quantitative amounts of individual fatty acids in the phospholipid fraction were <0.002-0.29% of total lipids from camembert, <0.002-0.12% of total lipids from mozzarella, and <0.002-0.18% of total lipids in a goat cream cheese. Differences in the fatty acid pattern of neutral and polar lipids were detected. The quantity of the fatty acids determined in the phospholipid fraction was divided by the factor 0.7 in order to convert the fatty acid content into the phospholipid content of the cheese samples. This factor is based on the contribution of 16:0 to dipalmitoylphosphatidylcholine (DPPC). The resulting DPPC equivalents (DPPCeq) were found to be representative for the average contribution of fatty acids to all classes of phospholipids in dairy products. Using this approach, the phospholipid content of lipids from mozzarella, camembert, and goat cream cheese was 0.60%, 1.42% and 0.79%, respectively.  相似文献   

14.
A novel, fast and sensitive enantioselective HPLC assay with a new core–shell isopropyl carbamate cyclofructan 6 (superficially porous particle, SPP) chiral column (LarihcShell-P, LSP) was developed and validated for the enantiomeric separation and quantification of verapamil (VER) in rat plasma. The polar organic mobile phase composed of acetonitrile/methanol/trifluoroacetic acid/triethylamine (98:2:0.05: 0.025, v/v/v/v) and a flow rate of 0.5 mL/min was applied. Fluorescence detection set at excitation/emission wavelengths 280/313 nm was used and the whole analysis process was within 3.5 min, which is 10-fold lower than the previous reported HPLC methods in the literature. Propranolol was selected as the internal standard. The S-(−)- and R-(+)-VER enantiomers with the IS were extracted from rat plasma by utilizing Waters Oasis HLB C18 solid phase extraction cartridges without interference from endogenous compounds. The developed assay was validated following the US-FDA guidelines over the concentration range of 1–450 ng/mL (r2 ≥ 0.997) for each enantiomer (plasma) and the lower limit of quantification was 1 ng/mL for both isomers. The intra- and inter-day precisions were not more than 11.6% and the recoveries of S-(−)- and R-(+)-VER at all quality control levels ranged from 92.3% to 98.2%. The developed approach was successfully applied to the stereoselective pharmacokinetic study of VER enantiomers after oral administration of 10 mg/kg racemic VER to Wistar rats. It was found that S-(−)-VER established higher Cmax and area under the concentration-time curve (AUC) values than the R-(+)-enantiomer. The newly developed approach is the first chiral HPLC for the enantiomeric separation and quantification of verapamil utilizing a core–shell isopropyl carbamate cyclofructan 6 chiral column in rat plasma within 3.5 min after solid phase extraction (SPE).  相似文献   

15.
A new liquid chromatography-mass spectrometry (LC-MS)-based method coupled with pressurized liquid extraction (PLE) as an efficient sample preparation technique has been developed for the quantification and fingerprint analysis of Solanum xanthocarpum. Optimum separations of the samples were achieved on a Waters MSC-18 XTerra column, using 0.5% (v/v) formic acid in water (A) and acetonitrile (ACN):2-propanol:formic acid (94.5:5:0.5, v/v/v) (B) as mobile phase. The separation was carried out using linear gradient elution with a flow rate of 1.0mL/min. The gradient was: 0min, 20% B; 14min, 30% B; 20min, 30% B; 27min, 60% B and the column was re-equilibrated to the initial condition (20% B) for 10min prior to next injection. The steroidal glycoalkaloids (SGAs) which are the major active constituents were isolated as pure compounds from the crude methanolic extract of S. xanthocarpum by preparative LC-MS and after characterization were used as external standards for the development and validation of the method. Extracts prepared by conventional Soxhlet extraction, PLE and ultrasonication were used for analysis. The method was validated for repeatability, precision (intra- and inter-day variation), accuracy (recovery) and sensitivity (limit of detection and limit of quantitation). The purpose of the work was to develop a validated method, which can be used for the quantification of SGAs in commercialized S. xanthocarpum products and the fingerprint analysis for their routine quality control.  相似文献   

16.
A new approach is presented for the determination of avoparcin in tissue. Complete recovery from spiked swine kidney was achieved with hot water modified with 30% ethanol (v/v). The samples were extracted at 75 degrees C and 50 atm by accelerated solvent extraction. In situ sample clean-up was achieved by using matrix solid-phase dispersion utilizing the acrylic polymer XAD-7 HP, and by adding triethylammonium phosphate (TEAP) to the extraction solvent. The aqueous extracts were concentrated by solid-phase extraction (SPE) on the hydrophilic interaction chromatography (HILIC) material polyhydroxyethyl aspartamide. Complete analyte retention was possible during SPE when the kidney extracts were modified with 70% ethanol. A 200 A, 5 microm HILIC column with UV225 detection was used for the separation of avoparcin. The retention time was less than 15 min with 47% aqueous component in acetonitrile and 15 mM TEAP as eluent. The average recovery of avoparcin from kidney samples was 108%.  相似文献   

17.
Objective of this study was to investigate the effect of using pre-packed Si (Si), manually packed silica hydrated with water (Si-H(2)O) and pre-packed aminopropyl-bonded silica (NH(2)), at various mass ratios of lipid to sorbent, on the recovery of polar lipids following the solid-phase extraction (SPE) of a standard mixture of lipids. We also applied SPE using these sorbents to the separation of lipids from oyster tissues and compared the fatty acid (FA) composition of each fraction. Recoveries of phospholipids after SPE using Si increased with an increasing ratio of lipid to sorbent. Although the use of Si-H(2)O improved the recovery of polar lipid compared to that obtained on Si, the neutral lipid from gills and muscles of oyster showed distorted FA compositions presumably due to a leakage of polar lipids. Finally, NH(2) eluted with methanol provided good recoveries of phospholipids from the standard mixture; although polar lipids of oyster tissues showed a reduction in 20:4n-6 and MUFA likely due to the selective retention of acidic phospholipids.  相似文献   

18.
A method based on solid-phase extraction (SPE) and capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) is described for the separation and determination of six cytokinin nucleotides in coconut water. The best CZE separation for the six cytokinin nucleotide standards was achieved using a 25 mM ammonium formate/formic acid buffer (pH 3.8) and 2% (v/v) methanol with an applied gradient separation voltage (25 kV for 32 min, and then a linear gradient to 30 kV in 5 min, finally 30 kV to the end of separation) in less than 60 min. MS/MS with multiple reaction monitoring (MRM) detection was carried out to obtain sufficient selectivity and sensitivity for the cytokinin nucleotides. The combined use of on-line sample stacking and CZE-MS/MS achieved limits of detection (LODs) in the range of 0.06-0.19 microM for the six cytokinin nucleotides at a signal-to-noise ratio of 3. Furthermore, a novel dual-step SPE procedure was developed for the pre-concentration and purification of cytokinin nucleotides using Oasis HLB and Oasis MAX cartridges. The recoveries of the cytokinin nucleotides after the dual-step SPE were in the range of 44-71%. The combination of off-line SPE, on-line sample stacking and CZE-MS/MS approach was successfully applied to screen for endogenous cytokinin nucleotides present in coconut water sample. trans-Zeatin riboside-5'-monophosphate (ZMP) was detected and quantified in coconut water by CZE-MS/MS after SPE and on-line sample stacking.  相似文献   

19.
A perfusion reversed-phase HPLC method enabling the simultaneous separation of soybean and cereal (wheat, corn, and rice) proteins in commercial bakery products has been proposed for the first time. The method utilises an acetonitrile-water gradient containing an ion-pairing agent. Different ion-pairing agents were tried, 0.3% (v/v) acetic acid being observed to enable the separation of soybean from wheat, rice, and corn proteins while with 0.1% (v/v) trifluoroacetic acid only the separation of soybean and corn proteins was possible. Optimisation of the solubilisation conditions for proteins was achieved by testing different acetonitrile concentrations for the simultaneous extraction of soybean and cereal proteins: best recoveries were found with 25% (v/v) acetonitrile + 0.3% (v/v) acetic acid and with 40% (v/v) acetonitrile + 0.1% (v/v) trifluoroacetic acid. Chromatographic conditions such as gradient, temperature, and wavelength detection were also optimised. The method enabled the separation of soybean and cereal proteins in binary mixtures (soybean and wheat, soybean and corn, or soybean and rice proteins) in less than 5 minutes in a total analysis time of 20 min.  相似文献   

20.
黄娟  陈国松  张晓燕  沈崇钰  吕辰  吴斌  刘艳  陈惠兰  丁涛 《色谱》2012,30(11):1203-1207
建立了粮食及其制品中呕吐毒素的高效液相色谱-串联质谱(HPLC-MS/MS)检测方法。样品经乙腈-水(84:16, v/v)溶液提取,HLB固相萃取柱富集净化,采用HPLC-MS/MS法对目标物进行定性确证和定量分析。在Phenomenex Kinetex C18柱(100 mm×4.6 mm, 2.6 μm)上以0.3‰氨水和乙腈为流动相进行梯度洗脱分离;质谱模式为电喷雾负离子监测模式。本方法的检出限(以信噪比(S/N)=3计)和定量限(以S/N=10计)分别为20 μg/kg和50 μg/kg;在20~1000 μg/L范围内呈现良好的线性关系,相关系数(r)大于0.99。对本底空白的面粉、大麦、大豆、大米、玉米粉、木薯干、小麦等7种代表性基质进行50、100、500 μg/kg 3个含量水平的添加试验,回收率范围为75.6%~111.0%,精密度(以相对标准偏差(RSD)计)不大于13.0%。本方法准确可靠,灵敏度高,经济实用,可替代较为昂贵的免疫亲和柱和多功能净化柱,较大地降低检测成本。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号