首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 419 毫秒
1.
Investigations have been carried out for the electrodeposition of milligram amounts of uranium on electropolished stainless steel disks with an objective of preparing good quality sources for -spectrometric studies on uranium. The parameters studied include the variation of electrodeposition yield as a function of voltage, time, distance between the cathode and anode, and the volume of 0.2M ammonium oxalate solution. The conditions selected for preparing good quality sources with nearly 100% yield were: electrodeposition voltage 25 V, time of deposition 15 min, volume of 0.2M ammonium oxalate solution in the cell 4 ml and a distance of 2 cm between the cathode and anode. The sources prepared using this method have been used successfully for the -spectrometric determination of234U/238U ratios in uranium samples.  相似文献   

2.
In the course of measurements of uranium contamination in rivers of the Guadiana basin we have found the logical contamination near the uranium mines and a234U/238U ratio near 1 in the neighbourhood of the sources. With distance we find not only the expected decreasing contamination but also higher values of the activity ratio234U/238U. This observation seems to contradict the usual explanation of preferential leaching of234U as origin of the general234U enrichment of ground water.  相似文献   

3.
A simple, rapid and reliable method was developed for the simultaneous determination of uranium and plutonium isotopes by alpha-spectrometry using a single source. A new uranium tracer230U was applied as well as the236Pu tracer to determine overall yields of uranium and plutonium isotopes throughout the entire procedure employed. The analytical procedure consists of sample leaching with 8N HNO3 solution, purification by solvent extraction, simultaneous electrodeposition of U and Pu, and subsequent alpha-spectrometry with a silicon detector. In the solvent extraction using TOA/xylene from 8N HNO3 solution, the preferential extractability of Pu rather than U permits to purify simultaneously the trace amounts of Pu and the macro amounts of U, as in the case of ordinary soil samples, resulting in favourable peak heights for both isotopes. From a single alpha-spectrum, the determinations of238U,234U (and their ratio of234U/238U),239+240Pu, and238Pu contents were conveniently carried out after correcting the overall yields obtained from230U and236Pu activities in the same spectrum. This analytical method was satisfactorily applied to the determination of U and Pu isotope contents in some soils.  相似文献   

4.
Tetracycline in solution of benzyl alcohol was used as an extracting agent to separate uranium from interfering elements in the determination of uranium and of isotopic ratio235U/238U by neutron activation analysis. Separation gives a recovery of 97% for uranium and the interferences from matrices of pitchblende and monazite are eliminated.From a dissertation submitted by R. Petrauskas to the University of São Paulo in partial fulfilment for a Master of Science Degree in Nuclear Technology.  相似文献   

5.
A method that combines the use of non-destructive neutron activation analysis and high-resolution α spectrometry has been developed for determination of the activities of 234U and 238U in geological samples of low uranium content. The 238U content is determined by k0-based neutron activation analysis, whereas the 234U/238U relationship is measured by α spectrometry after isolation and electrodeposition of the uranium extracted from a lixiviation with 6 M HCl. The main advantage of the method is the simplicity of the chemical operations, including the fact that the steps destined to assure similar chemical state for the tracer and the uranium species present in the sample are not necessary. The method was applied to soil samples from sites of the North Peru Coast. Uranium concentration range 3–40 mg/kg and the isotopic composition correspond to natural uranium, with about 10% uncertainty.  相似文献   

6.
As a result of the accident at the Chernobyl nuclear power plant (NPP) the environment was contaminated with spent nuclear fuel. The 236U isotope was used in this study to monitor the spent uranium from nuclear fallout in soil samples collected in the vicinity of the Chernobyl NPP. Nuclear track radiography was applied for the identification and extraction of hot radioactive particles from soil samples. A rapid and sensitive analytical procedure was developed for uranium isotopic ratio measurement in environmental samples based on double-focusing inductively coupled plasma mass spectrometry (DF–ICP–MS) with a MicroMist nebulizer and a direct injection high-efficiency nebulizer (DIHEN). The performance of the DF–ICP–MS with a quartz DIHEN and plasma shielded torch was studied. Overall detection efficiencies of 4×10–4 and 10–3 counts per atom were achieved for 238U in DF–ICP–QMS with the MicroMist nebulizer and DIHEN, respectively. The rate of formation of uranium hydride ions UH+/U+ was 1.2×10–4 and 1.4×10–4, respectively. The precision of short-term measurements of uranium isotopic ratios (n = 5) in 1 μg L–1 NBS U-020 standard solution was 0.11% (238U/235U) and 1.4% (236U/238U) using a MicroMist nebulizer and 0.25% (235U/238U) and 1.9% (236U/238U) using a DIHEN. The isotopic composition of all investigated Chernobyl soil samples differed from those of natural uranium; i.e. in these samples the 236U/238U ratio ranged from 10–5 to 10–3. Results obtained with ICP–MS, α- and γ-spectrometry showed differences in the migration properties of spent uranium, plutonium, and americium. The isotopic ratio of uranium was also measured in hot particles extracted from soil samples.  相似文献   

7.
Preconcentration of uranium from natural water samples using Chelex-100 cation-exchange resin, its selective extraction by tributylphosphate and electrodeposition on stainless steel discs is reported. The validity of the separation procedure and the chemical recoveries were checked by addition of uranium standard solution as well as by tracing with 232U. The average uranium yield for the cation-exchange was (97±2)%, for the liquid-liquid extraction was (95±2)% and for the electrodeposition was more than 99%. Employing high-resolution a-spectroscopy, the measured activity of 238U and 234U radioisotopes was found to be ~7 mBq.l-1 and ~35 mBq.l-1 for ground- and seawater samples, respectively. The energy resolution (FWHM) of the α-peaks was 22 keV, the minimum detectable activity (MDA) was estimated to be 1 mBq.l-1 (at 95% confidence limit). This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

8.
The effect of sediment size, pH, temperature and conductivity on the transfer of uranium from sediment to water has been studied. The uranium concentration and the234U/238U,235U/238U activity ratios were measured in water, sediments and suspended matter sampled from Jucar River, using low level alpha-spectrometry. Distribution factors were obtained from these measurements. A more detailed sampling was done in the neighbourhood of the Cofrentes Nuclear Plant (Valencia, Spain). Total uranium activity,234U/238U activity ratio and distribution factors for234U and238U were found to vary with pH. Leaching and dilution, which depend on pH and salinity, are the probable mechanisms for these changes.  相似文献   

9.

4H-SiC alpha detectors were fabricated with a 21-μm thick depletion depth and were packaged into a stainless-steel casing with a mineral insulation cable and a standard BNC connector. The packaged detectors had a resolution of 0.624% FWHM at 5.486 MeV prior to salt immersion. The detectors were then immersed in a LiCl–KCl–UCl3 molten salt at 500 °C, from which a thin layer of depleted uranium was electrodeposited onto the detectors. Alpha particle emission spectra were collected from the electrodeposited source. The energy resolution of the surviving detector was 2.29% FWHM at 4.198 MeV and was sufficient to separate the 234U from 238U alpha emissions (577 keV difference). The 234U/238U activity ratio and the isotopic concentrations of 234U and 238U were determined and are representative of the uranium source used in the electrodeposition.

  相似文献   

10.
The smear samples of the penetrator were analyzed for the determination of the uranium composition. The obtained relative composition (m/m) of uranium isotopes in all the smear samples is in the range of 99.76-99.78% for 238U, 0.000659-0.000696% for 234U, 0.213-0.234% for 235U, and 0.00274-0.00328% for 236U, showing characteristics of depleted uranium (DU). The uranium concentrations in Kosovo soil and water samples as well as biological samples were investigated. It was found that the uranium concentrations in the Kosovo soil samples are in the range of 11.3-2.26·105 Bq·kg-1 for 238U, 10.3-3.01·104 Bq·kg-1 for 234U, 0.60-3251 Bq·kg-1 for 235U, and £0.019-1309 Bq·kg-1 for 236U. The obtained activity ratios are in the range of 0.112-1.086 for 234U/238U, 0.0123-0.1144 for 235U/238U, and 0-0.0078 for 236U/238U, indicating the presence of DU in about 77% of the surface soil samples. At a specific site, the DU inventory in the surface soil is about 140 mg·cm-2, which is 1.68·106 times higher as the estimated mean DU dispersion rate in the region. The uranium concentrations in Kosovo lichen, mushroom, bark, etc., are in the range of 1.97-4.06·104 Bq·kg-1 for 238U, 0.48-5158 Bq·kg-1 for 234U, 0.032-617 Bq·kg-1 for 235U, and £0.019-235 Bq·kg-1 for 236U with mean activity ratios of 0.325±0.0223 for 234U/238U, of 0.0238±0.0122 for 235U/238U, and 0.0034±0.0028 for +U/238U, indicating the presence of DU in the entire sample. On the contrary, the uranium concentrations in Kosovo water samples are low, compared with the water samples collected in central Italy, indicating the presence of negligible amount of DU. The uranium isotopes in Kosovo waters do not constitute a risk of health at the present time. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

11.
Activity concentrations of 234U, 238U and 226Ra in mineral waters were determined on the basis of nine water bottling facilities using alpha particle spectrometry. The mineral water samples were collected from three geographic regions of Turkey. The radiochemical separation used in the uranium analysis is based on the isolation of uranium radioisotopes from other radionuclides such as Th, Am, Pu and Np using UTEVA resin. Alpha sources were prepared using electrodeposition method. The activity concentration of 226Ra was determined after deposition on a membrane using BaSO4 co-precipitation method. The activity concentrations (mBq L?1) of 226Ra, 238U and 234U ranged from <0.56 to 165, from <0.42 to 439 and from <0.42 to 464, respectively. The measured activity concentrations were used for the calculation of the average total annual effective ingestion doses for children and adults. The committed effective doses were calculated for three different scenarios according to mineral water consumption rate. In the most extreme scenario (for age group 12–17), all water samples except MW1 and MW2 cause annual committed effective doses below the reference level (0.1 mSv year?1) recommended by World Health Organization (WHO).  相似文献   

12.
Zheng J  Yamada M 《Talanta》2006,68(3):932-939
The determination of uranium is important for environmental radioactivity monitoring, which investigates the releases of uranium from nuclear facilities and of naturally occurring radioactive materials by the coal, oil, natural gas, mineral, ore refining and phosphate fertilizer industries, and it is also important for studies on the biogeochemical behavior of uranium in the environment. In this paper, we describe a quadrupole ICP-MS (ICP-QMS)-based analytical procedure for the accurate determination of U isotope ratios (235U/238U atom ratio and 234U/238U activity ratio) in sediment samples. A two-stage sample cleanup using anion-exchange and TEVA extraction chromatography was employed in order to obtain accurate and precise 234U/238U activity ratios. The factors that affect the accuracy and precision of U isotope ratio analysis, such as detector dead time, abundance sensitivity, dwell time and mass bias were carefully evaluated and corrected. With natural U, a precision lower than 0.5% R.S.D. for 235U/238U atom ratio and lower than 2.0% R.S.D. for 234U/238U activity ratio was obtained with less than 90 ng uranium. The developed analytical method was validated using an ocean sediment reference material and applied to an investigation into the uranium isotopic compositions in a sediment core in a brackish lake in the vicinity of U-related nuclear facilities in Japan.  相似文献   

13.
Certified reference material (CRM) 115, Uranium (Depleted) Metal (Uranium Assay Standard), was analyzed using a TRITON Thermal Ionization Mass Spectrometer to characterize the uranium isotope-amount ratios. The certified 235U/238U “major” isotope-amount ratio of 0.0020337 (12) in CRM 115 was determined using the total evaporation (TE) and the modified total evaporation (MTE) analytical techniques. In the MTE method, the total evaporation process is interrupted on a regular basis to allow correction of background from peak tailing, internal calibration of the secondary electron multiplier detector versus the Faraday cups, peak-centering, and ion source re-focusing. For the “minor” 234U/238U and 236U/238U isotope-amount ratio measurements using MTE, precision and accuracy comparable to conventional analyses are achieved, without compromising the quality of the 235U/238U isotope-amount ratios. Characterized values of the 234U/238U and 236U/238U isotope-amount ratios in CRM 115 are 0.000007545 (10) and 0.000032213 (84), respectively. The 233U/238U isotope-amount ratio in CRM 115 is estimated to be <5 × 10?9. The homogeneity of the CRM 115 materials is established through the absence of any statistically significant unit-to-unit variation in the uranium isotope-amount ratios. The measurements leading to the certification of uranium isotope-amount ratios are discussed.  相似文献   

14.
Precise long-term measurements of uranium and thorium isotope ratios was carried out in 1 μg/L solutions using a quadrupole inductively coupled plasma mass spectrometer (ICP-QMS). The isotopic ratios of uranium (235U/ 238U = 1, 0.02 and 0.00725) were determined using a cross-flow nebulizer (CFN, at solution uptake rate of 1 mL/min) and a low-flow microconcentric nebulizer (MCN, at solution uptake rate of 0.2 mL/min) over 20 h. For 1 μg/L uranium solution (235U/238U = 1) relative external standard deviations (RESDs) of 0.05% and 0.044% using CFN and MCN, respectively, can be achieved. Additional short term isotope ratio measurements using a direct injection high-efficiency nebulizer (DIHEN) of 1 μg/L uranium solution (235U/238U = 1) at a solution uptake rate of 0.1 mL/min yielded an RSD of 0.06–0.08%. The sensitivity of solution introduction by DIHEN for uranium, thorium and plutonium (145 MHz/ppm, 150 MHz/ppm and 177 MHz/ppm, respectively) increased significantly compared to CFN and MCN and the solution uptake rate can be reduced to 1 μL/ min in DIHEN-ICP-MS. Isotope ratio measurements at an ultralow concentration level (e.g. determination of 240Pu/ 239Pu isotope ratio in a 10 ng/L Pu waste solution) were carried out for the characterization of radioactive waste and environmental samples.  相似文献   

15.
Activity concentrations of 238U, 235U and 234U were determined in different sources of drinking water at the Obuasi gold mines and its surrounding areas in Ghana. Water samples collected from the mines and its surrounding areas were analyzed using direct gamma-ray spectrometry and neutron activation analysis. The 234U/238U and 235U/238U ratios were calculated and the mean values range from 1.27 to 1.38 and from 0.044 to 0.045 respectively. The average 234U/238U ratio was from 1.27 for groundwater to 1.38 for treated water, demonstrating the lack of equilibrium. The average 235U/238U activity ratio is 0.045, indicating that only natural uranium was detected in the samples investigated.  相似文献   

16.
An analytical method for the ultratrace and isotopic analysis of uranium in radioactive waste samples using a double-focusing sector field ICP mass spectrometer is described. In high-purity water a detection limit for uranium in the lowest fg/mL range has been achieved. Under optimum experimental conditions (235U/238U ≈ 1), the precision in 235U/238U isotopic ratio determinations has been determined as 0.07% RSD. With the isotopic standard U-020 (235U/238U = 0.0208) a precision of 0.23% RSD at the 100 pg/mL level using ultrasonic nebulization has been achieved. With 234U/238U isotopic ratios of down to 10–5, the values obtained by double-focusing sector field ICP-MS and alpha spectrometry were in agreement. Received: 27 February 1997 / Revised: 10 Juni 1997 / Accepted: 12 June 1997  相似文献   

17.
A new technique to measure 234U/238U and 236U/238U isotope ratios for individual particles in environmental samples was developed, which was a combination of particle isolation under scanning electron microscope (SEM) and secondary ion mass spectrometry (SIMS). The technique was verified by measuring 234U/238U and 236U/238U isotope ratios in individual particles in a simulated environmental sample containing uranium standard (NBL CRM U010) and Pb metal particles. When the uranium particles were not isolated, the relative deviations of the measured isotope ratios from the reference values increased with increasing the signal intensity ratio of 208Pb to 238U, which was due to the molecular ion interferences by the Pb particles co-existing in the sputtered area. By the isolation of individual uranium particles, the interferences were eliminated and the measured isotope ratios were in good agreement with the reference values. The maximum relative deviations among 20 particles were 8.9% for 234U/238U and 13.1% for 236U/238U isotope ratios, respectively. The technique was also successfully applied to the analysis of a real swipe sample containing various kinds of elements.  相似文献   

18.
Uranium concentration in groundwater reflect both redox conditions and uranium content in host rock. In the present study an attempt has been made to study the uranium concentration and activity ratios of uranium isotopes to present the geochemical conditions of the groundwater in Malwa region of Punjab state, India and the reason for high uranium levels and variation of activity ratios from secular equilibrium conditions. Uranium concentration in groundwater samples was found to be in the range of 13.9 ± 1.2 to 172.8 ± 12.3 μg/l with an average value of 72.9 μg/l which is higher than the national and international guideline values. On the basis of uranium concentration, the groundwater of the study region may be classified as oxidized aquifer on normal uranium content strata (20 %) or oxidized aquifer on enhanced uranium content strata (80 %). The 238U, 235U and 234U isotopic concentration in groundwater samples was found to be in the range of 89.2–1534.5, 4.4–68.5, and 76.4–1386.2 mBq/l, respectively. Activity ratios of 234U/238U varies from 0.94 to 1.85 with a mean value of 1.11 which is close to unity that shows secular equilibrium condition. High value of 234U isotope than 238U may be due to alpha recoil phenomenon. The plot of AR of 234U/238U against the total uranium content in log scale reveals that the groundwaters of the study region either belongs to stable accumulation or normal oxidized aquifer.  相似文献   

19.
Precise long-term measurements of uranium and thorium isotope ratios was carried out in 1 μg/L solutions using a quadrupole inductively coupled plasma mass spectrometer (ICP-QMS). The isotopic ratios of uranium (235U/ 238U = 1, 0.02 and 0.00725) were determined using a cross-flow nebulizer (CFN, at solution uptake rate of 1 mL/min) and a low-flow microconcentric nebulizer (MCN, at solution uptake rate of 0.2 mL/min) over 20 h. For 1 μg/L uranium solution (235U/238U = 1) relative external standard deviations (RESDs) of 0.05% and 0.044% using CFN and MCN, respectively, can be achieved. Additional short term isotope ratio measurements using a direct injection high-efficiency nebulizer (DIHEN) of 1 μg/L uranium solution (235U/238U = 1) at a solution uptake rate of 0.1 mL/min yielded an RSD of 0.06–0.08%. The sensitivity of solution introduction by DIHEN for uranium, thorium and plutonium (145 MHz/ppm, 150 MHz/ppm and 177 MHz/ppm, respectively) increased significantly compared to CFN and MCN and the solution uptake rate can be reduced to 1 μL/ min in DIHEN-ICP-MS. Isotope ratio measurements at an ultralow concentration level (e.g. determination of 240Pu/ 239Pu isotope ratio in a 10 ng/L Pu waste solution) were carried out for the characterization of radioactive waste and environmental samples. Received: 1 December 1998 / Revised: 25 January 1999 / Accepted: 31 January 1999  相似文献   

20.
The 234U/238U isotope ratio has been widely used as a tracer for geochemical processes in underground aquifers. Quadrupole-based inductively coupled plasma mass spectrometry (ICP-MS) equipped with a high-efficiency nebulizer and a membrane desolvator was employed for the determination of 234U/238U isotope ratios in natural water samples. The instrumental limit of detection for 234U was at the low pg L−1 level with very low sample consumption. Measurement precision (234U/238U) was 3–5% for bottled mineral water with elevated uranium concentration (>1 μg L−1). For the analysis of groundwater samples from the Almonte-Marisma underground aquifer (Huelva, Spain), uranium was stripped from stainless steel planchets that had previously been used as radiometric counting sources for alpha-particle spectrometry. Potential spectral interferences from other metals introduced during the dissolution were investigated. Matrix-matched blank solutions were needed to subtract the background on 234U due to the formation of platinum argides, and to allow for mass bias correction and background correction. The Pt appears to be an impurity present in the stainless steel, either as a minor component by itself or after extraction from the anode and a subsequent uranium electrodeposition. The 234U/238U isotope ratio data were in very good agreement with those of alpha spectrometry, while precision was improved by a factor of up to 10 and counting time was reduced down to ~20 min (10 replicate measurements).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号