首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 20 毫秒
1.
The sequence coverage by fragment ions resulting from collision-induced dissociation in a triple stage quadrupole (TSQ) and a quadrupole ion trap (QIT) mass spectrometer of 10-20-mer oligonucleotides was investigated. While (a-B) and w ion series were the most abundant on both instruments, additional ion series of sequence relevance were preferably formed in the TSQ. Thus, a total number of 83 fragment ions were used to deduce the complete sequence of a 10-mer oligonucleotide of mixed sequence from a tandem mass spectrum recorded on the TSQ. The complete sequence was also encoded in the 28 fragments that were obtained from the QIT under comparable fragmentation conditions. Spectrum complexity increased considerably at the cost of signal-to-noise ratio upon fragmentation of a 20-mer oligonucleotide in the TSQ, whereas spectrum interpretation with longer oligonucleotides was significantly more straightforward in spectra recorded on the QIT. The extent of fragmentation had to be optimized by appropriate setting of collision energy and choice of precursor ion charge state in order to obtain full sequence coverage by fragments for de novo sequencing. Moreover, full sequence information was also dependent on base sequence because of the low tendency of backbone cleavage at thymidines. Tandem mass spectrometry on the QIT yielded redundant information that was successfully utilized to deduce the complete sequence of 20-mer oligonucleotides with high confidence.  相似文献   

2.
Some applications of collision dynamics in the field of quadrupole mass spectrometry are presented. Previous data on the collision induced dissociation of ions in triple quadrupole mass spectrometers is reviewed. A new method to calculate the internal energy distribution of activated ions directly from the increase in the cross section for dissociation with center of mass energy is presented. This method, although approximate, demonstrates explicitly the high efficiency of transfer of translational to internal energy of organic ions. It is argued that at eV center of mass energies, collisions between protein ions and neutrals such as Ar are expected to be highly inelastic. The discovery and application of collisional cooling in radio frequency quadrupoles is reviewed. Some previously unpresented data on fragment ion energies in triple quadrupole tandem mass spectrometry are shown that demonstrate directly the loss of kinetic energy of fragment ions in the cooling process. The development of the energy loss method to measure collision cross sections of protein ions in triple quadrupole instruments is reviewed along with a new discussion of the effects of inelastic collisions in these experiments and related ion mobility experiments.  相似文献   

3.
The combination of electrospray ionization (ESI) and quadrupole time-of-flight (Q-Tof) mass spectrometry presents a powerful tool to verify/determine the sequence of oligonucleotides. An ESI-Q-Tof instrument provides better sensitivity and much higher resolution compared with either ESI-triple quadrupole or ESI-ion trap devices. With high-resolution capability, the quadrupole time-of-flight instrument can provide an isotope pattern to support the charge state assignment. This will improve the reliability of the assignments of sequence-related w or a-Base series ions and lead to accurate determination of the oligonucleotide sequence.  相似文献   

4.
A double quadrupole mass spectrometer has been constructed to study unimolecular and collision-induced dissociation products from mass-selected ions. The two quadrupoles are closely coupled and the dissociation products sampled from a 2.5-mm interquadrupole region. Spectra obtained on the double quadrupole instrument are compared with published data obtained with triple quadrupole and reversed-sector (MIKE) mass spectrometers. The results indicate that the simple double quadrupole spectrometer is a highly efficient device which is a viable alternative to more complex quadrupole or sector instruments for obtaining dissociation spectra of mass-selected ions.  相似文献   

5.
6.
A novel matrix-assisted laser desorption/ionisation quadrupole ion trap time-of-flight (MALDI QIT ToF) mass spectrometer has been used to analyse high mass peptide ions exceeding 2000 Da. Human adrenocorticotropic hormone (fragment 18-39) and oxidised bovine insulin chain B were utilised to evaluate the performance of the instrument both in MS and in MS/MS mode. Its ability to efficiently isolate ions and to fragment them using collisionally activated decomposition (CAD) has been demonstrated using mixtures diluted to the low-femtomole level on target. Additionally, multiple stage mass spectrometry (MS/MS/MS) provides a second-generation product ion spectrum in which new fragment ions are detected and new stretches of amino acids are identified.  相似文献   

7.
Some ions exhibit "ion fragility" in quadrupole ion trap mass spectrometry (QIT-MS) during mass analysis with resonance ejection. In many cases, different ions generated from the same compound exhibit different degrees of ion fragility, with some ions (e.g., the [M+H](+) ion) stable and other ions (e.g., the [M+Na](+) ion) fragile. The ion fragility for quadrupole ion trap (QIT) mass spectrometry (MS) for protonated and sodiated ions of three phospholipids, 1,2-dipalmitoyl-sn-glycero-3-phosphocholine, PC (16:0/16:0), 1,2-dipalmitoyl-sn-glycero-3-phophoethanolamine, PE (16:0/16:0), and N-palmitoyl-D-erythro-sphingosylphosphorylcholine, SM (d18:1/16:0), was determined using three previously developed experiments: 1) the peak width using a slow scan speed, 2) the width of the isolation window for efficient isolation, and 3) the energy required for collision-induced dissociation. In addition, ion fragility studies were designed and performed to explore a correlation between ion fragility in QIT mass analysis and ion fragility during transport between the ion source and the ion trap. These experiments were: 1) evaluating the amount of thermal-induced dissociation as a function of heated capillary temperature, and 2) determining the extent of fragmentation occurring with increasing tube lens voltage. All phospholipid species studied exhibited greater ion fragility as protonated species in ion trap mass analysis than as sodiated species. In addition, the protonated species of both SM (d18:0/16:0) and PC (16:0/16:0) exhibited greater tendencies to fragment at higher heated capillary temperatures and high tube lens voltages, whereas the PE (16:0/16:0) ions did not appear to exhibit fragility during ion transport.  相似文献   

8.
A variety of model biopolymers, including oligonucleotides, oligosaccharides and a synthetic pharmaceutical agent, were sequenced using a triple quadrupole mass spectrometer equipped with an electrospray source and operated in a scan mode referred to as pseudo-MS3. This scan mode consists of three steps: (1) in-source collision-induced dissociation (CID) in the nozzle-skimmer (NS) region, (2) scanning of the fragment ions into the collision cell for further CID, and (3) passing of the secondary fragment ions through the final mass filter at a preselected mass, generally corresponding to the mass of a terminal sequence ion for the biopolymer. The mass spectra are recorded in the precursor ion MS/MS mode where ion selection and detection occur at the third stage of the triple quadrupole but the scan function is determined by the first stage. The advantages and limitations in using this pseudo-MS3 NS/precursor ion MS/MS scan mode for biopolymer sequencing are discussed.  相似文献   

9.
The potent neurotoxins from cyanobacteria, anatoxin-a (AN), its methyl analogue, homoanatoxin-a (HMAN), and their degradation products, have been studied using nano-electrospray hybrid quadrupole time-of-flight mass spectrometry (QqTOF-MS). The anatoxin degradation products, which are readily produced in vivo by either reduction or epoxidation, were also examined in this study. The high mass accuracy QqTOF-MS data was used to confirm formula assignments for major product ions and quadrupole ion-trap (QIT)-MS was used to construct fragmentation pathways for anatoxins. Significant differences between these fragmentation pathways were observed. Comparisons between the spectra of compounds that differ in side-chain length (the AN and HMAN series) were used to identify ions that are characteristic of the homologues. The application to forensic samples in which the principal neurotoxin had undergone rapid biodegradation has been demonstrated and used to confirm anatoxin poisoning of dogs.  相似文献   

10.
Multistage mass spectrometry, as implemented using low-energy collision-induced dissociation (CID) analysis in three-dimensional (3D) quadrupole ion traps (QITs), has become a powerful tool for the investigation of protein glycosylation. In addition to the well-known combination of QITs with electrospray ionization (ESI), also a matrix-assisted laser desorption/ionization--quadrupole ion trap--reflectron time-of-flight (MALDI-QIT-rTOF) mass spectrometer has recently become available. This study systematically investigates the differences between these types of instrument, as applied to characterization of glycopeptides from human antithrombin. The glycopeptides were obtained by tryptic digestion followed by lectin-affinity purification. Some significant differences between the ESI-QIT and MALDI-QIT-rTOF approaches appeared, most of them are causally related to the desorption/ionization process. The combination of a vacuum MALDI source with an ion-trap analyzer accentuates some characteristic differences between MALDI and ESI due the longer time frame needed for the trapping process. In contrast to ESI, MALDI generated ions that exhibited considerable metastable fragmentation during trapping. The long time span of the QIT process (ms range) compared with that for conventional rTOF experiments (micros range) significantly magnified the extent of this metastable fragmentation. With the investigated glycopeptides, a complete depletion of the terminal sialic acids of the glycopeptides as well as a variety of other fragment ions was already found in the MS1 spectra from the MALDI-QIT-rTOF instrument. The positive ion low-energy CID spectra (MS2) of the selected glycopeptides obtained using the two different QIT equipped instruments were found to be quite similar. In both approaches, fragmentation of the glycan and peptide structures occurred sequentially, allowing unambiguous sequence determination. In the case of ESI-QIT-MS, fragmentation of the glycan structure occurred at the MS2 stage and fragmentation of the peptide structure was obtained only at the MS3 stage, which indicates the necessity of multistage CID experiments for complete structure elucidation. The MALDI-QIT-rTOF instrument yielded both kinds of fragments at the MS2 stage but without mutual interference.  相似文献   

11.
采用电喷雾串联质谱技术对两组单核苷酸多态性(SNP)样品进行了研究,初步研究结果显示应用串联质谱可快速鉴定SNP分型以及确定SNP位点。采用16.3 mmol/L三乙胺(TEA)-400 mmol/L六氟异丙醇(HFIP)缓存溶液,电喷雾负离子模式下,长度为20 bp的寡核苷酸的MS扫描谱图显示其母离子呈较宽的多电荷态分布。选择低电荷态[M-4H]4-母离子,碰撞能为54 eV时,MS/MS扫描得到丰富的碎片离子,通过鉴定特征离子碎片(w和a-B离子系列)可确定其序列。  相似文献   

12.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry has become an important technique to characterize the chemical structure of industrial polymer materials. MALDI methods have been developed to address a broad variety of different polymer materials containing different chemistries. One of the key aspects of the typical MALDI experiment is the generation of intact ions. The development of Atmospheric Pressure (AP) MALDI quadrupole ion trap (QIT) instruments has opened another channel to obtaining MS/MS experiments for polymer samples. These experiments provide a new method to obtain chemical structure information from MALDI experiments. Collision-Induced Dissociation (CID) provides an improved MALDI MS/MS experiment that can be done on readily available mass spectrometers. AP MALDI QIT techniques have been successfully applied to a variety of synthetic polymers. This work explores the applicability of AP MALDI QIT methods to relatively low molecular weight ethoxylated surfactants. In these experiments we show the CID fragmentation mass spectra on some ethoxylated surfactants, and demonstrate the existence of analyte matrix clusters.  相似文献   

13.
Four liquid chromatography/mass spectrometry (LC/MS) systems, equipped with single quadrupole, triple quadrupole (QqQ), quadrupole ion trap (QIT) and quadrupole time-of-flight (QqTOF) mass analyzers, were evaluated for the analysis of carbosulfan and its main transformation products. The comparison of quantitative aspects (sensitivity, precision and accuracy) was emphasized. Results showed that the triple quadrupole instrument reaches at least 20-fold higher sensitivity (LOD from 0.04 to 0.4 microg kg(-1)) compared to the single quadrupole (4-70 microg kg(-1)), the QIT (4-25 microg kg(-1)) and the QqTOF (4-23 microg kg(-1)) instruments. Recoveries were over 70% for all the analytes, except dibutylamine and 7-phenolcarbofuran. Repeatabilities (within-day) were slightly better by the single quadrupole (5-10%) and the QqQ (5-9%) than by the QIT (12-16%) and the QqTOF (9-16%). Both the QqTOF and QIT offer a linear dynamic range of two orders of magnitude whereas the single quadrupole and QqQ of, at least, three orders of magnitude. The method was applied to analyze carbosulfan field-treated orange samples, in which carbosulfan, carbofuran, 3-hydroxycarbofuran, and dibutylamine were found. As an example, the mean carbosulfan concentration was 20 +/- 0.6 microg kg(-1) measured by the QqQ, 22 +/- 1.2 microg kg(-1) by the single quadrupole, 25 +/- 2.8 microg kg(-1) by the QIT, and 20 +/- 1.8 microg kg(-1) by the QqTOF. Although the QqQ is more sensitive and precise, the mean values obtained by the four instruments are acceptable and comparable. The potential of each technique for the verification of the identity of residues detected in oranges is discussed using the concept of identification points.  相似文献   

14.
We report negative-ion electrospray tandem mass spectrometric methods for structural characterization of cardiolipin (CL), a four-acyl-chain phospholipid containing two distinct phosphatidyl moieties, of which structural assignment of the fatty acid residues attached to the glycerol backbones performed by low-energy CAD tandem mass spectrometry has not been previously described. The low-energy MS2-spectra of the [M - H]- and [M - 2H]2- ions obtained with ion-trap or with tandem quadrupole instrument combined with ion-trap MS3-spectra or with source CAD product-ion spectra provide complete structural information for CL characterization. The MS2-spectra of the [M - H]- ions contain two sets of prominent fragment ions that comprise a phosphatidic acid, a dehydrated phosphatidylglycerol, and a (phosphatidic acid + 136) anion. The substantial differences in the abundances of the two distinct phosphatidic anions observed in the MS2-spectra of the [M -H]- ions lead to the assignment of the phosphatidyl moieties attached to the 1' or 3' position of central glycerol. Upon further collisional dissociation, the MS3-spectra of the phosphatidic anions provide information to identify the fatty acyl substituents and their position in the glycerol backbone. The MS2-spectra of the [M - 2H]2- ions obtained with TSQ or ITMS contain complementary information to confirm structural assignment. The applications of the above methods in the differentiation of cardiolipin isomers and in the identification of complex cardiolipin species consisting of multiple molecular structures are also demonstrated.  相似文献   

15.
Designs of a quadrupole ion trap (QIT) as a source for time‐of‐flight (TOF) mass spectrometry are evaluated for mass resolution, ion trapping, and laser activation of trapped ions. Comparisons are made with the standard hyperbolic electrode ion trap geometry for TOF mass analysis in both linear and reflectron modes. A parallel‐plate design for the QIT is found to give significantly improved TOF mass spectrometer performance. Effects of ion temperature, trapped ion cloud size, mass, and extraction field on mass resolution are investigated in detail by simulation of the TOF peak profiles. Mass resolution (mm) values of several thousand are predicted even at room temperature with moderate extraction fields for the optimized design. The optimized design also allows larger radial ion collection size compared with the hyperbolic ion trap, without compromising the mass resolution. The proposed design of the QIT also improves the ion–laser interaction volume and photon collection efficiency for fluorescence measurements on trapped ions. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
Liquid chromatography-triple quadrupole/mass spectrometry (LC-TQ/MS) and liquid chromatography-quadrupole ion trap/mass spectrometry (LC-QIT/MS) for determining bupirimate, hexaflumuron, tebufenpyrad, buprofezin, pyriproxyfen, and fluvalinate in fruits have been compared. The differences in the mass spectra obtained by triple and ion trap quadrupoles are discussed, showing how both of them provide interesting features. The evaluation of the two instruments was carried out by ethyl acetate extraction of oranges spiked with the studied pesticides at LOQ and 10 times the LOQ. Results obtained by LC-TQ/MS correlated well with those obtained by LC-QIT/MS. Recoveries were 70-94% by LC-TQ/MS and 72-92% by LC-QIT/MS with the R.S.D. from five replicate analysis 4-14% and 8-18%, respectively. Matrix effects were tested for both techniques by standard addition to blank extracts. Although the matrix effects are not originated in mass analyzer but in the LC/MS interface, they were, generally, more marked by LC-QIT-MS than by LC-TQ/MS. The limits of quantification (LOQs) were 0.005-0.2 mg kg(-1) by both equipments--appropriate values for determining these pesticides in orange from the regulatory point of view. The results indicate that the TQ provides higher precision, better linearity, it is more robust, and when the purpose of the analysis is quantitative determination, preferable over the QIT. However, the application of both mass spectrometers to analyze orange samples conventionally treated showed that any can be used for qualitative and quantitative purposes.  相似文献   

17.
A prototype matrix-assisted laser desorption/ionization quadrupole time-of-flight (MALDI-TOF) tandem mass spectrometer was used to sequence a series of phosphotyrosine-, phosphothreonine- and phosphoserine-containing peptides. The high mass resolution and mass accuracy of the instrument allowed the localization of one, three or four phosphorylated amino acid residues in phosphopeptides up to 3.1 kDa. Tandem mass spectra of two different phosphotyrosine peptides permitted amino acid sequence determination and localization of one and three phosphorylation sites, respectively. The phosphotyrosine immonium ion at m/z 216.04 was observed in these MALDI low-energy CID tandem mass spectra. Elimination of phosphate groups was evident from the triphosphorylated peptide but not from the monophosphorylated species. The main fragmentation pathway for the synthetic phosphothreonine-containing peptide and for phosphoserine-containing peptides derived from beta-casein and ovalbumin was the beta-elimination of phosphoric acid with concomitant conversion of phosphoserine to dehydroalanine and phosphothreonine to 2-aminodehydrobutyric acid. Peptide fragment ions of the b- and y-type allowed, in all cases, the localization of phosphorylation sites. Ion signals corresponding to (b-17), (b-18) and (y-17) fragment ions were also observed. The abundant neutral loss of phosphoric acid (-98 Da) is useful for femtomole level detection of phosphoserine-peptides in crude peptide mixtures generated by gel in situ digestion of phosphoproteins.  相似文献   

18.
19.
The coupling of ion mobility spectrometry (IMS) instruments with mass spectrometers has been described since early in IMS development, most commonly with quadrupole mass analyzers. The recent development of IMS with time-of-flight (TOF) instruments has demonstrated that the time compatibility (IMS milliseconds and TOFMS microseconds) of the two techniques enables rapid two-dimensional separations to be performed, theoretically in the order of seconds for a complete analysis. This study presents a unique way to operate a traditional IMS/QMS system to attain separations similar to those achieved with IMS/TOF. For this new approach, the quadrupole was slowly scanned in the single-ion monitoring mode while IMS spectra were continually embedded in each m/z step. In this way, two-dimensional separations (IMS drift times and m/z) were obtained using the traditional IMS/QMS arrangement. An example of a five amino acid separation (quadrupole scan of 40 m/z values at a rate of approximately 7 steps/min) led to a complete two-dimensional analysis within 6 min, comparable to rapid chromatographic separations with mass spectrometry. Proposed approaches to reduce the analysis time are discussed and a reduction in the analysis time to less than 1 min is feasible when the IMS/QMS separation conditions are optimized.  相似文献   

20.
A simplified method for determining the sequence and branching of oligosaccharides using infrared multiphoton dissociation (IRMPD) in a quadrupole ion trap (QIT) is described. An IR-active boronic acid (IRABA) reagent is used to derivatize the oligosaccharides before IRMPD analysis. The IRABA ligand is designed to both enhance the efficiency of the derivatization reaction and to facilitate the photon absorption process. The resulting IRMPD spectra display oligosaccharide fragments that are formed from primarily one type of diagnostic cleavage, thus making sequencing straightforward. The presence of sequential fragment ions, a phenomenon of IRMPD, permit the comprehensive sequencing of the oligosaccharides studied in a single stage of activation. We demonstrate this approach for two series of oligosaccharides, the lacto-N-fucopentaoses (LNFPs) and the lacto-N-difucohexaoses (LNDFHs).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号