首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In recent years, there has been high interest in paper-based microfluidic sensors or microfluidic paper-based analytical devices (μPADs) towards low-cost, portable, and easy-to-use sensing for chemical and biological targets. μPAD allows spontaneous liquid flow without any external or internal pumping, as well as an innate filtration capability. Although both optical (colorimetric and fluorescent) and electrochemical detection have been demonstrated on μPADs, several limitations still remain, such as the need for additional equipment, vulnerability to ambient lighting perturbation, and inferior sensitivity. Herein, alternative detection methods on μPADs are reviewed to resolve these issues, including relatively well studied distance-based measurements and the newer capillary flow dynamics-based method. Detection principles, assay performance, strengths, and weaknesses are explained for these methods, along with their potential future applications towards point-of-care medical diagnostics and other field-based applications.  相似文献   

2.
S Wang  L Ge  X Song  M Yan  S Ge  J Yu  F Zeng 《The Analyst》2012,137(16):3821-3827
In this paper, chemiluminescence immunoassay (CLIA) was introduced into the recently proposed microfluidic paper-based analytical devices (μPADs) through covalent fabrication strategy for the first time. This novel paper-based CLIA, with high-throughput, rapid, stable and reusable CL response to trace amounts of analyte in real biological samples, combines the simplicity and low-cost of the μPADs with the high sensitivity and selectivity of CLIA. Periodate oxidation, which can form covalent bonds between polysaccharides and proteins, was used for activation of μPADs to covalently immobilize antibodies on μPADs in this work for the first time. Thus, the paper-based sandwich CLIA and regeneration of it can be easily realized for further development of this technique in sensitive, specific and low-cost applications. The application test of this paper-based CLIA was successfully performed, as a model, through the determination of biomarkers in human serum on paper microzone plate. The paper-based CLIA will be very useful when the level of an analyte in real biological sample is important for point-of-care testing, public health and environmental monitoring in remote regions, developing or developed countries.  相似文献   

3.
Paper-based analytical devices (PADs), including lateral flow assays (LFAs), dipstick assays and microfluidic PADs (μPADs), have a great impact on the healthcare realm and environmental monitoring. This is especially evident in developing countries because PADs-based point-of-care testing (POCT) enables to rapidly determine various (bio)chemical analytes in a miniaturized, cost-effective and user-friendly manner. Low sensitivity and poor specificity are the main bottlenecks associated with PADs, which limit the entry of PADs into the real-life applications. The application of nanomaterials in PADs is showing great improvement in their detection performance in terms of sensitivity, selectivity and accuracy since the nanomaterials have unique physicochemical properties. In this review, the research progress on the nanomaterial-based PADs is summarized by highlighting representative recent publications. We mainly focus on the detection principles, the sensing mechanisms of how they work and applications in disease diagnosis, environmental monitoring and food safety management. In addition, the limitations and challenges associated with the development of nanomaterial-based PADs are discussed, and further directions in this research field are proposed.  相似文献   

4.
Paper-based microfluidic devices (μPADs) are capable of achieving rapid quantitative measurements of a variety of analytes inexpensively. μPADs rely on patterning hydrophilic-hydrophobic regions on a sheet of paper in order to create capillary channels within impermeable fluidic brakes on the paper. Here, we present a novel, highly flexible and low-cost fabrication method using a desktop digital craft plotter/cutter and technical drawing pens with tip size of 0.5 mm. The pens were used with either commercial black permanent ink for drawing fluidic brakes, or with specialty in-house formulated aqueous inks. With the permanent marker ink it was possible to create barriers on paper rapidly and in a variety of designs in a highly flexible manner. For instance, a design featuring eight reservoirs can be produced within 10 s for each μPAD with a consistent line width of brakes (%RSD < 1.5). Further, we investigated the optimal viscosity range of in-house formulated inks controlled with additions of poly(ethylene glycol). The viscosity was measured by capillary electrophoresis and the optimal viscosity was in the range of ∼3–6 mPa s. A functional test of these μPADs was conducted by the screening of antioxidant activity. Colorimetric measurements of flavonoid, phenolic compounds and DPPH free radical scavenging activity were carried out on μPADs. The results can be detected by the naked eye and simply quantified by using a camera phone and image analysis software. The fabrication method using technical drawing pens provides flexibility in the use of in-house formulated inks, short fabrication time, simplicity and low cost.  相似文献   

5.
An online method involving transient electrokinetic dosing and ITP with neutralization reaction boundary (NRB) and/or carrier ampholyte-free isoelectric focusing (CAF IEF) was developed for the preconcentration, preseparation, and analytical determination of glyphosate in aqueous samples containing low concentrations of the analyte of interest. Various parameters were investigated in the framework of an optimization study with the aim of achieving the maximum concentration limit of detection (cLOD) decrease in minimum time. The proposed method used CAF IEF and/or ITP with NRB. The sample was dosed to the column on the stationary reaction boundary (CAF IEF) and/or moving reaction boundary (ITP with NRB), whereat a sharp pH step exists. Here, charge reversal was due to the ampholytes, and/or acid accumulation occurred because of charge loss. Similarly, the accumulated sample was mobilized with TE and analyzed using classical ITP in the second analytical column. Glyphosate (GLY), the analyte of interest, was chosen as a model substance for ITP with NRB and preconcentration as well as focusing preconcentration and CAF IEF using the asymmetric purpose-built NRB. On one side of the asymmetric boundary was the zone of acidic pH; while the opposite side comprised a neutral/basic non-conductive zone of the ampholyte—in this case, GLY. Such an arrangement enables the use of a lower pH on the acidic side, which allows the focusing of strongly acidic ampholytes and the accumulation of weak acids. The electrolyte composition and the dosing time were optimized, and a 14-fold accumulation was achieved in 25 min compared to that by classical ITP and a 180-fold accumulation was achieved through CAF IEF and preconcentration with a glyphosate sample. Both methods are simple and can be conducted using all commercial ITP systems.  相似文献   

6.
A quantitative method was developed for the direct identity confirmation and quantification of alendronate using CE-MS combined with a pH-assisted focusing technique, dynamic pH barrage junction focusing. A pH-induced variation in electrophoretic mobility led to online focusing of alendronate at the sample/pH barrage boundary, significantly improving the detection sensitivity. In addition, the use of a flow-through microvial CE electrospray interface and the multiple reaction monitoring mode of MS further improved the specificity and quantification capability of this technology. This quantitative method presented a wide linear dynamic range over 8–2000 ng/mL and an LOD of 2 ng/mL. A 460-fold improvement in sensitivity was obtained when pH barrage junction focusing was applied during the CE process, in comparison to when normal CE was conducted without online sample stacking. The superior detection sensitivity over previously reported methods enables direct analysis of bisphosphonate compounds, eliminating tedious pre-column sample enrichment and derivatization. Validation of alendronate content in a commercial drug tablet further proved the reliability and power of this method. This simple method with no sample derivatization, superior sensitivity, and short run time (<8 min) is a promising alternative for accurate quantification of alendronate and other types of bisphosphonate compounds in both drug formulations and plasma samples.  相似文献   

7.
Paper-based microfluidic devices are an alternative technology for fabricating simple, low-cost, portable and disposable platforms for clinical diagnosis. Hereby, a novel wax dipping method for fabricating paper-based microfluidic devices (μPADs) is reported. The iron mould for wax dipping was created by a laser cutting technique. The designed pattern was transferred onto paper by dipping an assembly mould into melted wax. The optimal melting temperature and dipping time were investigated. The optimal melting temperature was in the range of 120-130 °C, and the optimal dipping time was 1 s. The whole fabrication process could be finished within 1 min without the use of complicated instruments or organic solvents. The smallest hydrophilic channel that could be created by the wax dipping method was 639 ± 7 μm in size. The reproducibility of the μPAD fabrication for hydrophilic channel width of the test zone and sample zone was 1.48% and 6.30%, respectively. To verify the performance of the μPAD, multiple colorimetric assays for simultaneous detection of glucose and protein in real samples were performed. An enzymatic assay and the bromocresol green (BCG) method were conducted on the paper device to determine the presence of glucose and protein in a test solution. The results of the assays were not significantly different from those of the conventional methods (p > 0.05, pair t-test and one-way ANOVA method). The wax dipping provides a new alternative method for fabricating lab-on-paper devices for multiple clinical diagnostics and will be very beneficial for developing countries.  相似文献   

8.
Recent research on microfluidic paper‐based analytical devices (μPADs) has shown that paper has great potential for the fabrication of low‐cost diagnostic devices for healthcare and environmental monitoring applications. Herein, electrochemiluminescence (ECL) was introduced for the first time into μPADs that were based on screen‐printed paper‐electrodes. To further perform high‐specificity, high‐performance, and high‐sensitivity ECL on μPADs for point‐of‐care testing (POCT), ECL immunoassay capabilities were introduced into a wax‐patterned 3D paper‐based ECL device, which was characterized by SEM, contact‐angle measurement, and electrochemical impedance spectroscopy. With the aid of a home‐made device‐holder, the ECL reaction was triggered at room temperature. By using a typical tris(bipyridine)ruthenium–tri‐n‐propylamine ECL system, this paper‐based ECL 3D immunodevice was applied to the diagnosis of carcinoembryonic antigens in real clinical serum samples. This contribution further expands the number of sensitive and specific detection modes of μPADs.  相似文献   

9.
The present work describes the fabrication of paper‐based analytical devices (μPADs) by immobilization of glucose oxidase onto the screen printed carbon electrodes (SPCEs) for the electrochemical glucose detection. The sensitivity towards glucose was improved by using a SPCE prepared from homemade carbon ink mixed with cellulose acetate. In addition, 4‐aminophenylboronic acid (4‐APBA) was used as a redox mediator giving a lower detection potential for improvement selectivity. Under optimized condition, the detection limit was 0.86 mM. The proposed device was applied in real samples. This μPAD has many advantages including low sample consumption, rapid analysis method, and low device cost.  相似文献   

10.
We have evaluated double-stranded DNA separations in microfluidic devices which were designed to couple a sample preconcentration step based on isotachophoresis (ITP) with a zone electrophoretic (ZE) separation step as a method to increase the concentration limit of detection in microfluidic devices. Developed at ACLARA BioSciences, these LabCard trade mark devices are plastic 32 channel chips, designed with a long sample injection channel segment to increase the sample loading. These chips were designed to allow stacking of the sample into a narrow band using discontinuous ITP buffers, and subsequent separation in the ZE mode in sieving polymer solutions. Compared to chip ZE, the sensitivity was increased by 40-fold and we showed baseline resolution of all fragments in the PhiX174/HaeIII DNA digest. The total analysis time was 3 min/sample, or less than 100 min per LabCard device. The resolution for multiplexed PCR samples was the same as obtained in chip ZE. The limit of detection was 9 fg/microL of DNA in 0.1xpolymerase chain reaction (PCR) buffers using confocal fluorescence detection following 488 nm laser excitation with thiazole orange as the fluorescent intercalating dye.  相似文献   

11.
A novel method for electroosmotic flow (EOF) measurement on paper substrates is presented; it is based on dynamic mass measurements by simply using an analytical balance. This technique provides a more reliable alternative to other EOF measurement methods on porous media. The proposed method is used to increase the amount and quality of the available information about physical parameters that characterize fluid flow on microfluidic paper–based analytical devices (μPADs). Measurements were performed on some of the most frequently used materials for μPADs, i.e., Whatman #1 , S&S, and Muntktell 00A filter paper. Obtained experimental results are consistent with the few previously reported data, either experimental or numerical, characterizing EOF in paper substrates. Moreover, a thorough analysis is presented for the quantification of the different effects that affect the measurements such as Joule effect and evaporation. Experimental results enabled, for the first time, to establish well-defined electroosmotic characteristics for the three substrates in terms of the magnitude of EOF as funtion of pH, enabling researchers to make a rational choice of the substrate depending on the electrophoretic technique to be implemented. The measurement method can be described as robust, reliable, and affordable enough for being adopted by researchers and companies devoted to electrophoretic μPADs and related technologies.  相似文献   

12.
Lab-on-chip devices are widely being used for binary and ternary cell/particle separation applications. Among the lab-on-chip methods, dielectrophoresis (DEP) is a cost-effective and label-free method, with great capabilities for size-based separation of cells and particles, which is mostly performed in sheath-assisted forms. However, the elimination of the sheath flows offers advantages such as ease of operation and higher sample throughput. In this work, we present a comparison of sheath-assisted and sheathless DEP separation of three sizes of microparticles using tilted electrodes. The sheath-assisted design was capable of separating the 5, 10, and 15 μm particles with a separation efficiency as high as 98.0% for 15 μm particles. By adding a DEP focusing region, a sheathless DEP separator was proposed, which offered higher throughputs (up to 10 times) at the cost of lowering the separation efficiency (a reduction up to 10.3% for 15 μm) compared to the sheath-assisted design. To enhance the separation efficiency, a combination of the DEP focusing accompanied by weak sheath flows from both sides was proposed. This design achieved the highest sample separation yield in the outlets (as high as 98.7% for 15 μm) with a sample throughput of more than 4.2 μL/min. This study provides insights into the choice of an appropriate platform for any application in which the yield, purity, throughput, and portability must be considered.  相似文献   

13.
Many diagnostic tests in a conventional clinical laboratory are performed on blood plasma because changes in its composition often reflect the current status of pathological processes throughout the body. Recently, a significant research effort has been invested into the development of microfluidic paper-based analytical devices (μPADs) implementing these conventional laboratory tests for point-of-care diagnostics in resource-limited settings. This paper describes the use of red blood cell (RBC) agglutination for separating plasma from finger-prick volumes of whole blood directly in paper, and demonstrates the utility of this approach by integrating plasma separation and a colorimetric assay in a single μPAD. The μPAD was fabricated by printing its pattern onto chromatography paper with a solid ink (wax) printer and melting the ink to create hydrophobic barriers spanning through the entire thickness of the paper substrate. The μPAD was functionalized by spotting agglutinating antibodies onto the plasma separation zone in the center and the reagents of the colorimetric assay onto the test readout zones on the periphery of the device. To operate the μPAD, a drop of whole blood was placed directly onto the plasma separation zone of the device. RBCs in the whole blood sample agglutinated and remained in the central zone, while separated plasma wicked through the paper substrate into the test readout zones where analyte in plasma reacted with the reagents of the colorimetric assay to produce a visible color change. The color change was digitized with a portable scanner and converted to concentration values using a calibration curve. The purity and yield of separated plasma was sufficient for successful operation of the μPAD. This approach to plasma separation based on RBC agglutination will be particularly useful for designing fully integrated μPADs operating directly on small samples of whole blood.  相似文献   

14.
15.
Recent research on microfluidic paper-based analytical devices (μPADs) has shown that paper has great potential for the fabrication of low-cost diagnostic devices for healthcare and environmental monitoring applications. Herein, electrochemiluminescence (ECL) was introduced for the first time into μPADs that were based on screen-printed paper-electrodes. To further perform high-specificity, high-performance, and high-sensitivity ECL on μPADs for point-of-care testing (POCT), ECL immunoassay capabilities were introduced into a wax-patterned 3D paper-based ECL device, which was characterized by SEM, contact-angle measurement, and electrochemical impedance spectroscopy. With the aid of a home-made device-holder, the ECL reaction was triggered at room temperature. By using a typical tris(bipyridine)ruthenium-tri-n-propylamine ECL system, this paper-based ECL 3D immunodevice was applied to the diagnosis of carcinoembryonic antigens in real clinical serum samples. This contribution further expands the number of sensitive and specific detection modes of μPADs.  相似文献   

16.
Elemental analysis of rare earth elements is essential in a variety of fields including environmental monitoring and nuclear safeguards; however, current techniques are often labor intensive, time consuming, and/or costly to perform. The difficulty arises in preparing samples, which requires separating the chemically and physically similar lanthanides. However, by transitioning these separations to the microscale, the speed, cost, and simplicity of sample preparation can be drastically improved. Here, all fourteen non‐radioactive lanthanides (lanthanum through lutetium minus promethium) are separated by ITP for the first time in a serpentine fused‐silica microchannel (70 µm wide × 70 µm tall × 33 cm long) in <10 min at voltages ≤8 kV with limits of detection on the order of picomoles. This time includes the 2 min electrokinetic injection time at 2 kV to load sample into the microchannel. The final leading electrolyte consisted of 10 mM ammonium acetate, 7 mM α‐hydroxyisobutyric acid, 1% polyvinylpyrrolidone, and the final terminating electrolyte consisted of 10 mM acetic acid, 7 mM α‐hydroxyisobutyric acid, and 1% polyvinylpyrrolidone. Electrophoretic electrodes are embedded in the microchip reservoirs so that voltages can be quickly applied and switched during operation. The limits of detection are quantified using a commercial capacitively coupled contactless conductivity detector (C4D) to calculate ITP zone lengths in combination with ITP theory. Optimization of experimental procedures and reproducibility based on statistical analysis of subsequent experimental results are addressed. Percent error values in band length and conductivity are ≤8.1 and 0.37%, respectively.  相似文献   

17.
An EOF counter-balanced ITP boundary has been used to stack anions from high conductivity samples during continuous electrokinetic injection of the sample. In a polystyrenesulfonate/poly(diallyldimethylammonium chloride) polyelectrolyte coated capillary, the time at which the ITP boundary exited the capillary could be prolonged by balancing the movement of the boundary with the EOF. Using a bis-tris-propane electrolyte, the ITP boundary was removed from the capillary within 7 min, while when using triethanolamine the ITP boundary was still at 30% of the capillary after 2 h of injection. Using these systems, the sensitivity of a mixture of simple organic acids in 100 mM Cl was improved by 700–800-fold using bis-tris-propane with a whole-capillary injection of the sample and 5 min of electrokinetic injection at +28 kV, and 1100–1300-fold using triethanolamine and 60 min of electrokinetic injection under the same conditions. The potential of the method to be applicable to high conductivity samples was demonstrated by stacking a whole capillary filled with urine spiked with naphthalenedisulfonic acid, with limits of detection 450 times lower than those achievable with a normal hydrodynamic injection.  相似文献   

18.
A simple, rapid method using CE and microchip electrophoresis with C4D has been developed for the separation of four nonsteroidal anti-inflammatory drugs (NSAIDs) in the environmental sample. The investigated compounds were ibuprofen (IB), ketoprofen (KET), acetylsalicylic acid (ASA), and diclofenac sodium (DIC). In the present study, we applied for the first time microchip electrophoresis with C4D detection to the separation and detection of ASA, IB, DIC, and KET in the wastewater matrix. Under optimum conditions, the four NSAIDs compounds could be well separated in less than 1 min in a BGE composed of 20 mM His/15 mM Tris, pH 8.6, 2 mM hydroxypropyl-beta-cyclodextrin, and 10% methanol (v/v) at a separation voltage of 1000–1200 V. The proposed method showed excellent repeatability, good sensitivity (LODs ranging between 0.156 and 0.6 mg/L), low cost, high sample throughputs, portable instrumentation for mobile deployment, and extremely lower reagent and sample consumption. The developed method was applied to the analysis of pharmaceuticals in wastewater samples with satisfactory recoveries ranging from 62.5% to 118%.  相似文献   

19.
Point-of-care platforms can provide fast responses, decrease the overall cost of the treatment, allow for in-home determinations with or without a trained specialist, and improve the success of the treatment. This is especially true for microfluidic paper-based analytical devices (μPAD), which can enable the development of highly efficient and versatile analytical tools with applications in a variety of biomedical fields. The objective of this work was the development of μPADs to identify and quantify levels of nitrite in saliva, which has been proposed as a potential marker of periodontitis. The devices were fabricated by wax printing and allowed the detection of nitrite by a colorimetric reaction based on a modified version of the Griess reaction. The presented modifications, along with the implementation of a paper-based platform, address many of the common drawbacks (color development, stability, etc.) associated with the Griess reaction and are supported by results related to the design, characterization, and application of the proposed devices. Under the optimized conditions, the proposed devices enable the determination of nitrite in the 10–1000 μmol L−1 range with a limit of detection of 10 μmol L−1 and a sensitivity of 47.5 AU [log (μmol L−1)]−1. In order to demonstrate the potential impact of this technology in the healthcare industry, the devices were applied to the analysis of a series of real samples, covering the relevant clinical range.  相似文献   

20.
This article describes the use of microfluidic paper-based analytical devices (μPADs) to perform quantitative chemical assays with internal standards. MicroPADs are well-suited for colorimetric biochemical assays; however, errors can be introduced from the background color of the paper due to batch difference and age, and from color measurement devices. To reduce errors from these sources, a series of standard analyte solutions and the sample solution are assayed on a single device with multiple detection zones simultaneously; an analyte concentration calibration curve can thus be established from the standards. Since the μPAD design allows the colorimetric measurements of the standards and the sample to be conducted simultaneously and under the same condition, errors from the above sources can be minimized. The analytical approach reported in this work shows that μPADs can perform quantitative chemical analysis at very low cost.   相似文献   