首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Structural analysis of sulfated oligosaccharides from kappa-carrageenan of up to ten residues (MW >2 kDa) was successfully carried out by positive mode nano-ESI-FTICR-MS together with MS/MS using sustained off-resonance irradiation-collision induced dissociation (SORI-CID). Glycosidic bond cleavage reactions via the B- and Y-types of fragmentation were observed and enabled complete sequencing of the oligosaccharide samples. The positions of the labile sulfate substituents were observable using SORI-CID, enabling the determination of the sequence of the sulfated residues.  相似文献   

2.
Application of capillary electrophoresis (CE) as a high-resolution separation technique in metalloproteomics research is critically reviewed. The focus is on the requirements and challenges involved in coupling CE to sensitive element and molecule-specific detection techniques such as inductively coupled plasma mass spectrometry (ICP–MS) or electrospray ionisation mass spectrometry (ESI–MS). The complementary application of both detection techniques to the structural and functional characterisation of metal-binding proteins and their structural metal-binding moieties is emphasised. Beneficial aspects and limitations of mass spectrometry hyphenated to CE are discussed, on the basis of the literature published in this field over the last decade. Recent metalloproteomics applications of CE are reviewed to demonstrate its potential and limitations in modern biochemical speciation analysis and to indicate future directions of this technique.  相似文献   

3.
The chiral drug ketamine has long-lasting antidepressant effects with a fast onset and is also suitable to treat patients with therapy-resistant depression. The metabolite hydroxynorketamine (HNK) plays an important role in the antidepressant mechanism of action. Hydroxylation at the cyclohexanone ring occurs at positions 4, 5, and 6 and produces a total of 12 stereoisomers. Among those, the four 6HNK stereoisomers have the strongest antidepressant effects. Capillary electrophoresis with highly sulfated γ-cyclodextrin (CD) as a chiral selector in combination with mass spectrometry (MS) was used to develop a method for the enantioselective analysis of HNK stereoisomers with a special focus on the 6HNK stereoisomers. The partial filling approach was applied in order to avoid contamination of the MS with the chiral selector. Concentration of the chiral selector and the length of the separation zone were optimized. With 5% highly sulfated γ-CD in 20 mM ammonium formate with 10% formic acid and a 75% filling the four 6HNK stereoisomers could be separated with a resolution between 0.79 and 3.17. The method was applied to analyze fractionated equine urine collected after a ketamine infusion and to screen the fractions as well as unfractionated urine for the parent drug ketamine and other metabolites, including norketamine and dehydronorketamine.  相似文献   

4.
A capillary electrophoresis inductively coupled plasma mass spectrometry method for separation of free cisplatin from liposome-encapsulated cisplatin and protein-bound cisplatin was developed. A liposomal formulation of cisplatin based on PEGylated liposomes was used as model drug formulation. The effect of human plasma matrix on the analysis of liposome-encapsulated cisplatin and intact cisplatin was studied. The presence of 1 % of dextran and 4 mM of sodium dodecyl sulfate in HEPES buffer was demonstrated to be effective in improving the separation of liposomes and cisplatin bound to proteins in plasma. A detection limit of 41 ng/mL of platinum and a precision of 2.1 % (for 10 μg/mL of cisplatin standard) were obtained. Simultaneous measurements of phosphorous and platinum allows the simultaneous monitoring of the liposomes, liposome-encapsulated cisplatin, free cisplatin and cisplatin bound to plasma constituents in plasma samples. It was demonstrated that this approach is suitable for studies of the stability of liposome formulations as leakage of active drug from the liposomes and subsequent binding to biomolecules in plasma can be monitored. This methodology has not been reported before and will improve characterization of liposomal drugs during drug development and in studies on kinetics.
Figure
A method for distinguishing free cisplatin from liposome-encapsulated and protein-bound platinum in human plasma allows for studies of stability and kinetics of new drug formulations during drug development  相似文献   

5.
Biogenic (e.g. phytochelatins, porphyrins, DOM) as well as anthropogenic (e.g. NTA, EDTA, phosphonates) chelators affect the mobility and cycling of heavy metals in environmental waters. Since such chelators can form strongly bound anionic heavy metal complexes that are stable and highly mobile, anion-exchange chromatography coupled to ICP-MS was investigated. A narrow bore HPLC system was connected to a micro concentric nebuliser for in-line sample introduction. A new chromatographic procedure based on a synthetic hydrophilic quaternary ammonium anion exchanger in combination with nitrate as a strong eluent anion, and gradient elution, provided high separation selectivity and a large analytical window. Low detection limits (nmol L(-1)) were achieved by on-column matrix removal and sample preconcentration. This allowed the method to be successfully applied to different environmental research areas. In ecotoxicological studies of heavy metal effects on algae low concentrations of metal EDTA complexes were determined in nutrient solutions without interference from high (buffer) salt concentrations. In groundwater, infiltrated by a polluted river, mobile metal EDTA species were observed. In river water of different pollution levels beside CuEDTA other anionic Cu-complexes were found in nmol L(-1) concentrations.  相似文献   

6.
An on-line HPLC–ESI–MS–MS method has been developed for determination of glutathione and phytochelatins (PC) in plant tissues. For sample pretreatment, dithiothreitol (DTT) must be added at the very beginning, as an anti-oxidant. Optimization of instrumental conditions i.e. composition of HPLC mobile phase, ionization efficiency of the electrospray interface, and MS–MS detection in the multiple ion-monitoring mode, are the central aspects of this work. A polystyrene-packed column was found to be superior to a standard silica-packed reversed-phase column. A concave quadratic gradient of ammonium formate buffer and acetonitrile was found to be optimum. The limits of quantitation were 0.2 mol kg–1 plant tissue for glutathione and PC. The method has been applied to analysis of tissue samples from Vicia faba grown in Cd-containing nutrient solutions.Dedicated to the memory of Wilhelm Fresenius  相似文献   

7.
We describe here a new reversed-phase high-performance liquid chromatography with mass spectrometry detection method for quantifying intact cytokinin nucleotides in human K-562 leukemia cells. Tandem mass spectrometry was used to identify the intracellular metabolites (cytokinin monophosphorylated, diphosphorylated, and triphosphorylated nucleotides) in riboside-treated cells. For the protein precipitation and sample preparation, a trichloroacetic acid extraction method is used. Samples are then back-extracted with diethyl ether, lyophilized, reconstituted, and injected into the LC system. Analytes were quantified in negative selected ion monitoring mode using a single quadrupole mass spectrometer. The method was validated in terms of retention time stabilities, limits of detection, linearity, recovery, and analytical accuracy. The developed method was linear in the range of 1–1,000 pmol for all studied compounds. The limits of detection for the analytes vary from 0.2 to 0.6 pmol.  相似文献   

8.
We report on the use of hollow fiber liquid-liquid-liquid microextraction (HF-LLLME) followed by corona discharge ion mobility spectrometry for the determination of dextromethorphan and pseudoephedrine in urine and plasma samples. The effects of pH of the donor phase, stirring rate, ionic strength and extraction time on HF-LLLME were optimized. Under the optimized conditions, the linear range of the calibration curves for dextromethorphan in plasma and urine, respectively, are from 1.5 to 150 and from 1 to 100 ng mL?1. The ranges for pseudoephedrine, in turn, are from 30 to 300 and from 20 to 200 ng mL?1. Correlation coefficients are better than 0.9903. The limits of detection are 0.6 and 0.3 ng mL?1 for dextromethorphan, and 8.6 and 4.2 ng mL?1 for pseudoephedrine in plasma and urine samples, respectively. The relative standard deviations range from 6 to 8%.
Figure
Hollow fiber liquid–liquid–liquid microextraction (HF-LLLME) followed by corona discharge ion mobility spectrometry (CD-IMS) was used for the determination of dextromethorphan and pseudoephedrine in urine and plasma samples.  相似文献   

9.
Static headspace sampling, headspace solid-phase microextraction, and direct immersion solid-phase microextraction coupled with gas chromatography–tandem mass spectrometry have been developed for determination of the volatile components in Radix bupleuri injection. A total of 78 compounds were identified from Radix bupleuri injection. Direct immersion solid-phase microextraction gave a better extraction efficiency for polar compounds, including organic acids and alcohols, than headspace solid-phase microextraction or static headspace sampling. Product ion isotope pattern analysis was applied to determine the elemental composition of the precursor ion, which could make the qualitative analysis more accurate and reliable.  相似文献   

10.
A simple, specific and sensitive column liquid chromatography–tandem mass spectrometry method has been developed for the determination of amphotericin B in human cerebrospinal fluid. Samples were prepared by dilution with methanol and quantitated by MS–MS detection in the positive mode. The determination was validated in the concentration range of 0.5–100 ng mL?1 using 100 μL of human cerebrospinal fluid. The method was successfully used to support routine therapeutic drug monitoring.  相似文献   

11.
This paper presents the development, optimization and validation of a methodology to determine nine key steroid hormones (viz. pregnenolone, progesterone, dehydroepiandrosterone, androstenedione, testosterone, dihydrotestosterone, estrone, 17α-estradiol and 17β-estradiol) expressed in the steroidogenesis in biological fluids. The analytical method allows for the determination of steroid hormones in blood plasma and serum down to 0.08–0.16 ng/mL for estrogens, 0.20–0.36 ng/mL for androgens and 0.36–0.43 ng/mL for progestagens. These limits of detection were obtainable using a two-step solid-phase clean-up for fractionation and elimination of interfering lipids (fatty acids, phospholipids, glycerides and sterols) from the steroid hormones. The accuracy of the method was 50–112% in the range 0.10 to 2.00 ng/mL.  相似文献   

12.
A sensitive and selective liquid chromatography–tandem mass spectrometry method for the determination of memantine was developed and validated over the linearity range 0.1–25 ng mL?1 with 0.5 mL of plasma using procainamide as the internal standard. This analysis was carried out on a Cosmosil 5C18-MS column and the mobile phase was composed of methanol: 0.5% formic acid (50:50, v/v). Detection was performed on a triple–quadrupole tandem mass spectrometer using positive ion mode electrospray ionization and quantification was performed by multiple reaction monitoring mode. The MS–MS ion transitions monitored were m/z 180 → 107 and 236 → 163 for memantine and procainamide, respectively. The between- and within-day precision was less than 10.9% and accuracy was less than 2.5%. The lower limit of quantification (LLOQ) was 0.1 ng mL?1. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of memantine in healthy Chinese volunteers.  相似文献   

13.
A sensitive and selective liquid chromatographic tandem mass spectrometric (LC–MS–MS) method was developed for simultaneous identification and quantification of tamsulosin and dutasteride in human plasma, which was well applied to clinical study. The method was based on liquid–liquid extraction, followed by an LC procedure with a Gemini C-18, 50 mm × 2.0 mm (3 μm) column and using methanol:ammonium formate (97:3, v/v) as the mobile phase. Protonated ions formed by a turbo ionspray in positive mode were used to detect analytes and internal standard. MS–MS detection was by monitoring the fragmentation of 409.1 → 228.1 (m/z) for tamsulosin, 529.3 → 461.3 (m/z) for dutasteride and 373.2 → 305.3 (m/z) for finasteride (IS) on a triple quadrupole mass spectrometer. The lower limit of quantification for both tamsulosin and dutasteride was 1 ng mL?1. The proposed method enables the unambiguous identification and quantification of tamsulosin and dutasteride for clinical drug monitoring.  相似文献   

14.
An LC–MS–MS-based procedure for determination in hair of 14 different drugs of abuse belonging to the classes cocaine, amphetamine-like compounds, opiates, and hallucinogens has been developed. A pressurized-liquid extraction procedure was used and proved useful for quantitative recovery of all the analytes tested. This procedure, in conjunction with a simple decontamination step, performed to avoid false-positive samples, enabled the detection of all the analytes with LOQ ranging from 1.8 to 16 pg mg?1 and accuracy varying from 85 to 111 %. The procedure was validated in accordance with the SOFT/AAFS guidelines and seems to be suitable for routine determination of the drugs tested in hair.  相似文献   

15.
16.
Matrix solid-phase dispersion (MSPD) with alumina N as adsorbent has been used for extraction of para red, Sudan 1, Sudan 2, Sudan 3, and Sudan 4 dyes from egg yolk. The extracts were analyzed by ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS–MS). Mean recovery for the five dyes ranged from 63.2 to 98.6%, with CV 0.55–10.00%. One sample was confirmed to contain 0.3 mg kg?1 Sudan 4.  相似文献   

17.
Ginseng has been used by the Chinese as a traditional herbal medicine for thousands of years. In view of the growing popularity in the use of ginseng preparations as natural remedies and food supplements worldwide, there is an increasing concern for their abuse in both human and animal sports. Ginsenosides are considered the major constituents of ginseng responsible for its pharmacological properties. In this study, a method was developed for the detection and confirmation of a number of ginsenosides in horse urine. The intact ginsenosides were detected and confirmed at 5–100 ng mL?1 by LC–MS2, and two deglycosylation metabolites, namely protopanaxadiol and protopanaxatriol, could both be detected and confirmed at 2 ng mL?1 by GC–MS2 after trimethylsilylation. The above GC–MS and LC–MS methods were then applied to study the in vitro metabolism of ginsenosides Rg1 and Rb1 and the in vivo urinary metabolites after oral administration of Rg1 to horses. Results obtained reveal the very first evidence for the existence of the metabolites, Rg1 and protopanaxatriol, as glucuronides in urine.  相似文献   

18.
Li  Zhiping  Li  Qin  Wang  Yi  Cao  Di  Chen  Chao 《Chromatographia》2012,75(9-10):533-539

A sensitive and specific liquid chromatography electrospray ionization-tandem mass spectrometry method for determination of total and free piperacillin–tazobactam in human plasma has been developed and validated. Plasma deproteinization was achieved with Amicon® Ultra-0.5 mL centrifugal filter device (Millipore, Bedford, USA). Chromatography was performed on a Capcell Pak C18 MG column (ID 2 mm × 100 mm, 5 μm, Shiseido, Kyoto, Japan) with isocratic elution using a mobile phase containing water and acetonitrile with an addition of 0.02% of formic acid. Detection was achieved by an Applied Biosystems API 3000 triple quadrupole mass spectrometer (ABI-SCIEX, Toronto, Canada). Electrospray ionization (ESI) was used for ion production. The limits of quantification were 100 ng mL−1 for piperacillin and 30 ng mL−1 for tazobactam. The precision and accuracy for both intra- and inter-day determination of piperacillin ranged from 2.8 to 9.1% and from 94.9 to 104.4%. The precision and accuracy for intra- and inter-day determination of tazobactam ranged from 2.9 to 9.3% and from 88.9 to 99.8%. The precision and accuracy for intra- and inter-day determination of free piperacillin ranged from 4.4 to 14.7% and from 89.0 to 109.6%. The precision and accuracy for intra- and inter-day determination of free tazobactam ranged from 2.8 to 14.4% and from 93.9 to 108.0%. Fifty and 150 μL plasma were used for total and free piperacillin–tazobactam analysis, respectively. The validation results of this analytical method made it feasible for being used in a further pilot study of population pharmacokinetics of piperacillin–tazobactam in neonates.

  相似文献   

19.
20.
High-performance liquid chromatography with tandem mass spectrometry has been used for rapid, specific, and sensitive analysis of busulfan in human plasma. Busulfan-d8 was used as internal standard. Analysis was performed on a C18 column (50 mm × 2.1 mm, 3.5-µm particles) with water–methanol 80:20 (v/v) as mobile phase at a flow-rate of 0.30 mL min?1. Detection was by tandem triple–quadrupole mass spectrometry with turbo ion-spray ionization. Linear calibration plots were obtained over the concentration range 1.096–1,096 ng mL?1. The assay is ideally suited to monitoring of busulfan and determination of its pharmacokinetic data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号