首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Cellulose powder was acylated with mixtures containing acetic, fatty and acetic-fatty anhydrides to form acetic-fatty cellulose esters. The total degree of substitution (DS) of the mixed cellulose esters (MCE) ranged from 2 × 10−2 to 2.92. MCE were characterized by their interactions with water. Static contact angles with water were measured on a regular smooth surface. The values found were dependent on the fatty acyl content and independent of the acetyl content. In the case of acetic-oleic cellulose esters, the minimum DS of the oleoyl moiety required to obtain permanent water repellency was 3 × 10−4. The microporosity of the samples may account for this exceptional hydrophobic character. Nevertheless, water vapor adsorption measurements on powder samples revealed only a limited increase in hydrophobicity of the MCE compared to cellulose acetate with the same acetyl content. It was thus demonstrated that water repellency and vapor water adsorption are not correlated.  相似文献   

2.

The dairy processing industry in India, on an average basis, involves an extensive amount of thermal and electrical energy consumption, i.e. 2.51 × 105 kW MT−1 and 1.44 × 105 kW MT−1, respectively, for an installed milk food processing capacity of 1.21 × 105 TPD. However, energy consumption spectrum depends upon the level of automation along with better utilisation of utility resources. The global ultra-high-temperature (UHT) pasteurised milk trade was valued at € 52.29 billion in 2012 and is expected to reach € 114.38 billion by 2019–2020. In the present work energy, exergy and exergoeconomic evaluation of ultra-high-temperature milk pasteurisation plant have been considered. The overall energy efficiency and efficiency pertaining to executable potential of energy in UHT Milk Processing Unit were reported to be 86.36% and 53.02%. The specific exergy destruction and specific exergy improvement potential were estimated to be 219.23 kJ kg−1 and 137.60 kJ kg−1, respectively. The highest possible retrievable exergy potential of the plant was associated with heating coil, i.e. 158.98 kW, followed by homogeniser (54.62 kW), which pinpointed towards the possibility of huge technical improvement. The processing cost was enumerated to be highest for heating coil (rk: 38.35%) followed by regeneration-1 (rk: 23.40%). Further, the total operating cost rate associated with thermodynamic deficiencies of subunits was estimated to be highest for heating coil (4859.82 € H−1) followed by regenerator-2 (1264.88 € H−1) and homogeniser (1187.14 € H−1). The broad survey of thermoeconomic indices of subunits indicated that the level of exergetic destruction was far more on higher side.

  相似文献   

3.
The fortification of processed foods including dairy products is increasingly commonplace with phytosterols among many compounds used to improve the nutritional value of food products. It is also increasingly common practice for some dairy cattle feeds to be fortified for their potential to increase phytosterol levels in milk. In this study, a combined, streamlined protocol using acid hydrolysis, saponification and sample clean‐up was developed to enable the rapid and reliable measurement of phytosterols. The method was developed with focus on streamlining the overall technique to make it suitable for commercial laboratories, to reduce labor and consumable costs, while maintaining accuracy. A total of 12 different feed types commonly used in the dairy industry were analyzed with the highest and lowest sterol contents found in cotton seed oil and tannin with average phytosterol contents of 256 and <30 mg per 100 g, respectively. With a limit of reporting of 30 mg/kg for individual sterols and a correlation coefficient > 0.99, the method was validated for milk to enable feed comparison studies with respect to the total phytosterol content in raw milk.  相似文献   

4.
A simple and sensitive method for determination of free amino acids in milk by microchip electrophoresis (MCE) coupled with laser‐induced fluorescence (LIF) detection was developed. Seven kinds of standard amino acids were derivated with sulfoindocyanine succinimidyl ester (Cy5) and then perfectly measured by MCE‐LIF within 150 s. The parameters of MCE separation were carefully investigated to obtain the optimal conditions: 100 mmol·L?1 sodium borate solution (pH 10.0) as running buffer solution, 0.8 kV as injection voltage, 2.2 kV as separation voltage etc. The linear range of the detection of amino acids was from 0.01 µmol·L?1 to 1.0 µmol·L?1 and the detection limit was as low as about 1.0 nmol·L?1. This MCE‐LIF method was applied to the measurements of free amino acids in actual milk samples and satisfactory experimental results were achieved.  相似文献   

5.
Structural and electrical properties of HfO2 gate-dielectric metal-oxide-semiconductor (MOS) capacitors deposited by sputtering are investigated. The HfO2 high-k thin films have been deposited on p-type <100> silicon wafer using RF-Magnetron sputtering technique. The Ellipsometric, FTIR and AFM characterizations have been done. The thickness of the as deposited film is measured to be 35.38 nm. Post deposition annealing in N2 ambient is carried out at 350, 550, 750 °C. The chemical bonding and surface morphology of the film is verified using FTIR and AFM respectively. The structural characterization confirmed that the thin film was free of physical defects and root mean square surface roughness decreased as the annealing temperature increased. The smooth surface HfO2 thin films were used for Al/HfO2/p-Si MOS structures fabrication. The fabricated Al/HfO2/p-Si structure had been used for extracting electrical properties such as dielectric constant, EOT, interface trap density and leakage current density through capacitance voltage and current voltage measurements. The interface state density extracted from the GV measurement using Hill Coleman method. Sample annealed at 750 °C showed the lowest interface trap density (3.48 × 1011 eV−1 cm−2), effective oxide charge (1.33 × 1012 cm−2) and low leakage current density (3.39 × 10−9 A cm−2) at 1.5 V.  相似文献   

6.
A fast and effective method was developed to detect domoic acid based upon microchip electrophoresis combined with laser‐induced fluorescence detection. Through study of the gated injection process on the cross channel of the microchip, the low‐voltage mode with relatively longer sample loading time was adopted to reduce the sample discrimination and improve the signal sensitivity. Fluorescein isothiocyanate was used as the derivatizing reagent for domoic acid. Under the optimized conditions, domoic acid was completely separated in 60 s with separation efficiency of 1.35 × 105 m−1. The calibration curve was obtained in the range of 1.0 × 10−9 to 1.0 × 10−7 mol/L, and the detection limit reached 2.8 × 10−10 mol/L. This developed method was successfully applied to analyze domoic acid in real samples.  相似文献   

7.
This paper presents an electrical actuation scheme of dielectric droplet by negative liquid dielectrophoresis. A general model of lumped parameter electromechanics for evaluating the electromechanical force acting on the droplets is established. The model reveals the influence of actuation voltage, device geometry, and dielectric parameter on the actuation force for both conductive and dielectric medium. Using this model, we compare the actuation forces for four liquid combinations in the parallel-plate geometry and predict the low voltage actuation of dielectric droplets by negative dielectrophoresis. Parallel experimental results demonstrate such electric actuation of dielectric droplets, including droplet transport, splitting, merging, and dispending. All these dielectric droplet manipulations are achieved at voltages < 100 Vrms. The frequency dependence of droplet actuation velocity in aqueous solution is discussed and the existence of surfactant molecules is believed to play an important role by realigning with the AC electric field. Finally, we present coplanar manipulation of oil and water droplets and formation of oil-in-water emulsion droplet by applying the same low voltage.  相似文献   

8.
《中国化学快报》2023,34(4):107715
Liquid chromatography tandem mass spectrometry (LC-MS/MS) plays an important role in clinical diagnostics. Although LC-MS/MS is superior in terms of accurately quantifying molecules in complex matrices, instrument footprint, operation and maintenance complexity also hinder its expansion as the analytical technique of choice. In this study, a compact LC-MS instrument was developed, in which an assembled liquid chromatograph was coupled with a miniature ion trap mass spectrometer. The overall instrument has a footprint of 69 cm × 31 cm × 31 cm, and it requires no gas supply as well as minimum maintenance. Furthermore, the use of LC-MS is in accord with conventional clinical diagnostic protocols, and the choice of ion trap offers tandem MS performance. The results showed that the use of LC could improve both mixture analysis capability and detection sensitivity of the miniature mass spectrometer. After optimization, feasibility of this instrument in clinical practice was demonstrated by the quantitation of four widely used immunosuppressants in blood samples. Relatively good linearities were obtained, which spanned the reference ranges of effective therapeutic concentrations of each immunosuppressant. Intra-day and inter-day accuracy and precision of analytical method were also assessed. This work showed that a compact LC-MS instrument could be used in clinical diagnosis, either to replace conventional lab-scale instruments or to be used in POCT applications.  相似文献   

9.
In the present work, a high-performance liquid chromatography–tandem mass spectrometry method has been developed for the residue analysis of chloramphenicol (CAP) in several food matrices. Following the addition of D5-CAP as internal standard, egg, honey, and milk were extracted and cleaned by means of solid-phase extraction, utilizing multi-walled carbon nanotubes as sorbent. The extracts were separated on a Halo fused-core C18 column (50 mm × 2.1 mm, 2.7 μm) and quantified by a 4000 Q-trap mass spectrometer equipped with a TurboIonSpray™ interface using electrospray ionization and multiple-reaction monitoring mode. The method validation was performed according to the criteria of Commission Decision 2002/657/EC. The decision limit (CCα) and detection capability (CCβ) of CAP in milk were calculated for m/z 320.8 > 151.9. Due to the existence of slight signal suppression, quantification was performed by matrix-matched calibration curves, ranging from 0.1 to 100 ng mL−1, with regression coefficients of 0.9993, 0.9998, and 0.9997 for egg, honey, and milk, respectively. Mean recoveries of the CAP ranged from 95.8% to 102.3%, with the corresponding intra- and inter-day variation (relative standard deviation) less than 7.13% and 8.89%, respectively. The limit of detection and limit of quantification of the method were also reported. This method successfully applied to several food matrixes (egg, honey, and milk) and can serve as a monitoring tool to avoid unacceptable levels of residues of CAP entering the food chain.  相似文献   

10.
With almost 20 years having passed since John B. Phillips described the first comprehensive two-dimensional gas chromatography (GC × GC) separation, much has occurred in this ever-expanding field of separation science. GC × GC is currently one of the most effective techniques for the separation and analysis of complex mixtures, offering significantly greater peak capacities than conventional chromatographic methods. The technique is generally based upon separations performed on two chromatographic columns characterized by considerably different selectivities, joined together through a modulating interface. The modulator periodically traps or samples the primary column effluent, usually refocuses it into a narrow chromatographic band and injects the focused fraction into the secondary column. The modulator is often referred to as the ‘heart’ of the instrument, since a GC × GC separation is impossible without its use. This article reviews major innovations in GC × GC modulator development since its first use by Phillips in 1991. Emphasis has been placed on modulator design and function.  相似文献   

11.
In this work, light emissions and radicals formed by plasma of contact glow discharge electrolysis were investigated. The plasma was generated by glow discharges at the tip of a Pt anode in contact with a sulfuric acid solution. Emissions of H atoms and OH radicals were observed when the applied voltage was above 430 V. When the applied voltage increased to 450 V, emissions of O atoms were additionally detected. The emission intensities of these radicals and atoms increased with the increasing applied voltage. When the applied voltage exceeded 460 V, thermal radiation from the Pt anode was apparent in the visible and near infrared region. Electron temperature of the plasma increased with the applied voltage from 1.0 × 104 to 1.5 × 104 K by comparison of the intensities of Hα and Hβ lines. The mean electron density was estimated to be 7.4 × 1017 cm−3 by the method of Stark broadening.  相似文献   

12.
We recently showed that electrowetting‐enhanced sample preparation for MALDI‐MS (eMALDI) can increase the intensity of the MALDI signal by 2–25 times compared with conventional drop drying by concentrating all the dried sample in a single spot rather than leaving behind a heterogeneous coffee‐stain pattern. Here, we demonstrate that the eMALDI signal enhancement can be further increased to more than 100 times by systematically optimizing the electrowetting actuation frequency and amplitude. This enables 30 times signal increase for a peptide standard. Simultaneously, drop drying times can be reduced approximately five times by increasing the actuation voltage and/or decreasing the initial drop volume. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

13.
A simple, sensitive and rapid method has been developed for simultaneous separation and quantification of three different drugs: oxytocin (OT), norfloxacin (NOR) and diclofenac (DIC) sodium in milk samples using capillary electrophoresis (CE) with UV detection at 220 nm. Factors affecting the separation were pH, concentration of buffer and applied voltage. Separation was obtained in less than 9 min with sodium tetraborate buffer of pH 10.0 and applied voltage 30 kV. The separation was carried out from uncoated fused silica capillary with effective length of 50 cm with 75 µm i.d. The carrier electrolyte gave reproducible separation with calibration plots linear over 0.15–4.0 µg/mL for OT, 5–1000 µg/mL for NOR and 3–125 µg/mL for DIC. The lower limits of detection (LOD) were found to be 50 ng/mL for OT, and 1 µg/mL for NOR and DIC. The method was validated for the analysis of drugs in milk samples and pharmaceutical preparations with recovery of drugs within the range 96–100% with RSD 0.9–2.8%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
A novel electrogenerated chemiluminescence aptamer-based (ECL-AB) biosensor for the determination of a small molecule drug is designed employing cocaine-binding aptamer as molecular recognition element for cocaine as a model analyte and ruthenium complex served as an ECL label. A 5′-terminal cocaine-binding aptamer with the ECL label at 3′-terminal of the aptamer was utilized as an ECL probe. The ECL-AB biosensors were fabricated by immobilizing the ECL probe onto a gold electrode surface via thiol-Au interactions. An enhanced ECL signal is generated upon recognition of the target cocaine, attributed to a change in the conformation of the ECL probe from random coil-like configuration on the probe-modified film to three-way junction structure, in close proximity to the sensor interface. The integrated ECL intensity versus the concentration of cocaine was linear in the range from 5.0 × 10−9 to 3.0 × 10−7 M. The detection limit was 1.0 × 10−9 M. This work demonstrates that the combination of a highly binding aptamer to analyte with a highly sensitive ECL technique to design ECL-AB biosensor is a great promising approach for the determination of small molecule drugs.  相似文献   

15.
The portable capillary electrophoresis instrument is automated and features three independent channels with different background electrolytes to allow the concurrent optimized determination of three different categories of charged analytes. The fluidic system is based on a miniature manifold which is based on mechanically milled channels for injection of samples and buffers. The planar manifold pattern was designed to minimize the number of electronic valves required for each channel. The system utilizes pneumatic pressurization to transport solutions at the grounded as well as the high voltage side of the separation capillaries. The instrument has a compact design, with all components arranged in a briefcase with dimensions of 45 (w) × 35 (d) × 15 cm (h) and a weight of about 15 kg. It can operate continuously for 8 h in the battery-powered mode if only one electrophoresis channel is in use, or for about 2.5 h in the case of simultaneous employment of all three channels. The different operations, i.e. capillary flushing, rinsing of the interfaces at both capillary ends, sample injection and electrophoretic separation, are activated automatically with a control program featuring a graphical user interface. For demonstration, the system was employed successfully for the concurrent separation of different inorganic cations and anions, organic preservatives, additives and artificial sweeteners in various beverage and food matrices.  相似文献   

16.
In the present work, acidic and basic drugs were simultaneously extracted by a novel method of high efficiency herein referred to as two-step voltage dual electromembrane extraction (TSV-DEME). Optimizing effective parameters such as composition of organic liquid membrane, pH values of donor and acceptor solutions, voltage and duration of each step, the method had its figures of merit investigated in pure water, human plasma, wastewater, and breast milk samples. Simultaneous extraction of acidic and basic drugs was done by applying potentials of 150 V and 400 V for 6 min and 19 min as the first and second steps, respectively. The model compounds were extracted from 4 mL of sample solution (pH = 6) into 20 μL of each acceptor solution (32 mM NaOH for acidic drugs and 32 mM HCL for basic drugs). 1-Octanol was immobilized within the pores of a porous hollow fiber of polypropylene, as the supported liquid membrane (SLM) for acidic drugs, and 2-ethyle hexanol, as the SLM for basic drugs. The proposed TSV-DEME technique provided good linearity with the resulting correlation coefficients ranging from 0.993 to 0.998 over a concentration range of 1–1000 ng mL−1. The limit of detections of the drugs were found to range within 0.3–1.5 ng mL−1, while the corresponding repeatability ranged from 7.7 to 15.5% (n = 4). The proposed method was further compared to simple dual electromembrane extraction (DEME), indicating significantly higher recoveries for TSV-DEME procedure (38.1–68%), as compared to those of simple DEME procedure (17.7–46%). Finally, the optimized TSV-DEME was applied to extract and quantify model compounds in breast milk, wastewater, and plasma samples.  相似文献   

17.
In this study, an anodized tubular TiO2 electrode (ATTE) on titanium foil was prepared and used both as a photoanode and a cathode in an enzymatic photoelectrochemical system to split water into oxygen and hydrogen. The effect of applied voltage when anodized, thickness of the foil, electrolytes, annealing temperature, and cathodes was investigated (optimum conditions: 20 V of applied voltage in 0.5 vol.% of hydrofluoric acid, 0.25-mm foil thickness, and 450–650°C annealing temperature). The samples with higher activities had similar X-ray diffraction (XRD) patterns, clearly indicating that the samples showing the highest evolution rate were composed of both anatase and rutile, while those showing a lower evolution rate were made of either anatase or rutile. The ATTE successfully replaced the Pt mesh cathode and the immobilization of the enzyme enhanced the H2 evolution by 50% (from ca. 66 to 99 μmol/(h × cm2)). Moreover, the use of KOH instead of Tris–HCl buffer in a cathodic compartment further increased the H2 evolution to 115 μmol/(h × cm2).  相似文献   

18.
Based on an efficient sample clean‐up and field‐amplified sample injection online preconcentration technique in capillary electrophoresis with contactless conductivity detection, a new analytical method for the sensitive determination of melamine in milk samples was established. In order to remove the complex matrix interference, which resulted in a serious problem during field‐amplified sample injection, liquid–liquid extraction was utilized. As a result, liquid–liquid extraction provides excellent sample clean‐up efficiency when ethyl acetate was used as organic extraction by adjusting the pH of the sample solution to 9.5. Both inorganic salts and biological macromolecules are effectively removed by liquid–liquid extraction. The sample clean‐up procedure, capillary electrophoresis separation parameters and field‐amplified sample injection conditions are discussed in detail. The capillary electrophoresis separation was achieved within 5 min under the following conditions: an uncoated fused‐silica capillary, 12 mM HAc + 10 mM NaAc (pH = 4.6) as running buffer, separation voltage of +13 kV, electrokinetic injection of +12 kV × 10 s. Preliminary validation of the method performance with spiked melamine provided recoveries >90%, with limits of detection and quantification of 0.015 and 0.050 mg/kg, respectively. The relative standard deviations of intra‐ and inter‐day were below 6%. This newly developed method is sensitive and cost effective, therefore, suitable for screening of melamine contamination in milk products.  相似文献   

19.
Concentration sensitivity is a key performance indicator for analytical techniques including for capillary electrophoresis-mass spectrometry (CE–MS) with electrospray ionization (ESI). In this study, a flow-through microvial interface was used to couple CE with MS and improve the ESI stability and detection sensitivity. By infusing a peptide mixture through the interface into an MS detector at a typical flow rate for CE-MS analysis, the spatial region near the interface was mapped for MS signal intensity. When the sprayer tip was within a 6 × 6.5 × 5 mm region in front of the MS inlet, the ESI was stable with no significant loss of signal intensity for ions with m/z 239. Finite element simulations showed that the average electric field strength at the emitter tip did not change significantly with minor changes in emitter tip location. Experiments were conducted with four different mass spectrometer platforms coupled to CE via the flow-through microvial interface. Key performance indicators, that is, limit of detection (LOD) and linearity of calibration curves were measured for nine amino acids and five peptides. Inter- and intraday reproducibility were also tested. The results were shown to be suitable for quantification when internal standards were used.  相似文献   

20.
A Fast gas chromatography and mass spectrometry method for plant sterols/stanols analysis was developed, using a short capillary gas chromatography column (10 m × 0.1 mm internal diameter × 0.1 μm film thickness) coated with 5% diphenyl‐polysiloxane. A silylated mixture of the main plant sterols/stanols standards (β‐sitosterol, campesterol, stigmasterol, campestanol, sitostanol) was well separated in 1.5 min, with a good peak resolution (>1.4, determined on a critical chromatographic peak pair (β‐sitosterol and sitostanol)), repeatability (<13%), and sensitivity (<0.017 ng/mL). The suitability of this Fast chromatography method was tested on plant sterols/stanols‐enriched dairy products (yogurt and milk), which were subjected to lipid extraction, cold saponification, and silylation prior to injection. The analytical performance (sensitivity < 0.256 ng/mL and repeatability < 10.36%) and significant reduction of the analysis time and consumables demonstrate that Fast gas chromatography‐mass spectrometry method could be also employed for the plant sterols/stanols analysis in functional dairy products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号