首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
Two simple, accurate and highly sensitive spectrofluorometric methods were developed for the determination of ethamsylate (ETM). Method I is based on measuring the native fluorescence of ethamsylate in water at 354 nm after excitation at 302 nm. The calibration plot was rectilinear over the range of 0.05–1 μg/mL for ETM with limits of detection and quantitation of 7.9 and 26 ng/mL, respectively. Method II involved synchronous and first derivative synchronous fluorometric methods for the simultaneous determination of ethamsylate (ETM) and hydroquinone (HQ) which is considered as an impurity and/or acidic degradation product. The synchronous fluorescence of both the drug and its impurity were measured in methanol at Δ λ of 40 nm. The peak amplitudes (1D) were estimated at 293.85 or 334.17 nm for ETM and at 309.05 nm for HQ. Good linearity was obtained for ETM over the ranges 0.1–1.4 μg/mL and 0.1–1.0 μg/mL at 293.85 and 334.17 nm, respectively. For HQ, the calibration plot was rectilinear over the range of 0.01–0.14 μg/mL at 309.05 nm. Limits of detection were 20, 2.01 ng/mL and limits of quantitation were 60, 6.7 ng/mL for ETM and HQ by method II, respectively. Both methods were successfully applied to commercial ampoules and tablets. The results were in good agreement with those obtained by the reference method. Method I was utilized to study the stability of ETM and its degradation kinetics using peroxide. The apparent first-order rate constant, half-life times and activation energy of the degradation process were calculated. Method I was further extended to the in-vitro and in-vivo determination of ETM in spiked and real plasma samples. The mean% recoveries were 99.57 ± 3.85 and 89.39 ± 5.93 for spiked and real human plasma, respectively.  相似文献   

2.
A rapid, simple and highly sensitive second derivative synchronous fluorometric method has been developed for the simultaneous analysis of binary mixture of cinnarizine (CN) and domperidone (DOM). The method is based upon measurement of the native fluorescence of these drugs at Δλ = 80 nm in aqueous methanol (50% V/V). The different experimental parameters affecting the native fluorescence of the studied drugs were carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the range of 0.1 to 1.3 μg mL−1 and 0.1–3.0 μg mL−1 for CN and DOM, respectively with lower detection limits of 0.017 and 5.77 × 10−3 μg mL−1 and quantification limits of 0.058 and 0.02 μg mL−1 for CN and DOM. The proposed method was successfully applied for the determination of the studied compounds in synthetic mixtures and in commercial tablets. The results obtained were in good agreement with those obtained with reference methods. The high sensitivity attained by the synchronous fluorometric method allowed the determination of CN in real and spiked human plasma. The mean % recoveries in case of spiked human plasma (n = 3) were 96.39 ± 1.18 while that in real human plasma (n = 3) was 104.67 ± 4.16.  相似文献   

3.
A simple, sensitive and rapid spectrofluorometric method for determination of methocarbamol in pharmaceutical formulations and spiked human plasma has been developed. The proposed method is based on the measurement of the native fluorescence of methocarbamol in methanol at 313 nm after excitation at 277 nm. The relative fluorescence intensity-concentration plot was rectilinear over the range of 0.05–2.0 μg/mL, with good correlation (r = 0.9999), limit of detection of 0.007 μg/ mL and a lower limit of quantification of 0.022 μg/ mL. The described method was successfully applied for the determination of methocarbamol in its tablets without interference from co-formulated drugs, such as aspirin, diclofenac, paracetamol and ibuprofen, The results obtained were in good agreement with those obtained using the official method (USP 30).The high sensitivity of the method allowed the determination of the studied drug in spiked human plasma with average percentage recovery of 99.42 ± 3.84.  相似文献   

4.
A rapid, simple and highly sensitive first derivative synchronous spectrofluorimetric method was developed for the simultaneous analysis of a binary mixture of labetalol HCl (LBT) and furosemide (FUR) without prior separation. The method was based upon measuring the first derivative of synchronous fluorescence spectra of the two drugs at Δλ =130 nm in aqueous ethanol (55% V/V). The different experimental parameters affecting the synchronous fluorescence of the studied drugs were carefully studied and optimized. The first derivative amplitude-concentration plots were rectilinear over the range of 0.10 to 1.00 μg/mL and 0.05–0.50 μg/mL with lower detection limits of 0.0149 and 7×10−3 μg/mL and quantification limits of 0.045 and 0.021 μg/mL for LBT and FUR, respectively. The proposed method was successfully applied for the determination of the studied drugs in synthetic mixtures. The results obtained were in good agreement with those obtained by the reference methods.  相似文献   

5.
The synthesis and functionalization of carbon nanoparticles with PEG200 and mercaptosuccinic acid, rendering fluorescent carbon dots, is described. Fluorescent carbon dots (maximum excitation and emission at 320 and 430 nm, respectively) with average dimension 267 nm were obtained. The lifetime decay of the functionalized carbon dots is complex and a three component decay time model originated a good fit with the following lifetimes: τ 1 = 2.71 ns; τ 2 = 7.36 ns; τ 3 = 0.38 ns. The fluorescence intensity of the carbon dots is affected by the solvent, pH (apparent pK a of 7.4 ± 0.2) and iodide (Stern-Volmer constant of 78 ± 2 M−1).  相似文献   

6.
A sensitive, simple and selective spectrofluorimetric method was developed for the determination of Lamotrigine (LMT) in pharmaceutical formulations and biological fluids. The method is based on reaction of LMT with o-phthalaldehyde in presence of 2-mercaptoethanol in borate buffer of pH 9.8 to yield a highly fluorescent derivative that is measured at 448 nm after excitation at 337 nm. The different experimental parameters affecting the development and stability of the reaction product were carefully studied and optimized. The fluorescence-concentration plot was rectilinear over the range of 0.1–1.0 μg ml−1 with lower limit of detection (LOD) 0.02 μg ml−1 and limit of quantification (LOQ) 0.06 μg ml−1 respectively. The proposed method was successfully applied to the the analysis of commercial tablets. Statistical comparison of the results obtained by the proposed and reference method revealed no significant difference in the performance of the two methods regarding the accuracy and precision respectively. The proposed method was further extended to the in-vitro and in-vivo determination of the drug in spiked and real human plasma. The mean percentage recoveries in spiked and real human plasma (n = 3) were 95.78 ± 1.37 and 90.93 ± 2.34 respectively. Interference arising from co-administered drugs was also studied. A proposal for the reaction pathway with o-phthalaldehyde was postulated.  相似文献   

7.
Two component (ethidium bromide–caffeine, ethidium bromide–DNA) and three component (ethidium bromide–caffeine–DNA) systems in aqueous saline (0.01 M NaCl) phosphate buffer solutions (pH 6.86, T = 298 K) are studied spectrophotometrically. The equilibrium constants for dimerization of caffeine, K D  = 1.22 ± 2 M−1, and for heteroassociation of ethidium bromide with caffeine, K = 71 ± 8 M−1, in ethidium bromide–caffeine systems are determined. When the concentration of caffeine is increased, the dynamic equilibrium of the solution shifts toward formation of heterocomplexes which are, presumably, stabilized by dispersive and hydrophobic interactions of chromophores. The equilibrium parameters for ethidium bromide complex formation with DNA are calculated: the coupling constant for the dye with the biopolymer, K 1 = (232 ± 16)⋅103 M−1, and the number of base pairs of the biopolymer participating in bonding with the ligand, n 1 = 3.6 ± 0.2, are calculated. Given these values, it is suggested that under these experimental conditions there are two types of bonding between ethidium bromide and the nucleic acid — intercalation and “external” bonds. A McGhee–von Hippel model for a three component system and the numerical values of the parameters for molecular complex formation in two component systems are used to calculate the bonding constant for caffeine with DNA, K 2 = 127 ± 30 M−1, and the number of base pairs of DNA which bond with caffeine, n 2 = 1.7 ± 0.2. The concentrations of ethidium bromide and caffeine in the composition of two and three component complexes are calculated as functions of the nucleic acid content in the solution. An analysis of the concentration dependences shows that heteroassociation of ligands has a significant effect on the reduction in the concentration of ethidium bromide–DNA complexes in a three component system for low DNA concentrations, while at high DNA concentrations the bonding of caffeine with the biopolymer has this effect. Translated from Zhurnal Prikladnoi Spektroskopii, Vol. 76, No. 1, pp. 143–151, January–February 2009.  相似文献   

8.
Performance of the backward wave oscillator (BWO) is greatly enhanced with the introduction of plasma. Linear theory of the dispersion relation and the growth rate have been derived and analysed numerically for plasma-filled rippled wall rectangular waveguide driven by sheet electron beam. To see the effect of plasma on the TM01 cold wave structure mode and on the generated frequency, the parameters used are: relativistic factor γ = 1.5 (i.e. v/c = 0.741), average waveguide height y 0 = 1.445 cm, axial corrugation period z 0 = 1.67 cm, and corrugation amplitude ε = 0.225 cm. The plasma density is varied from zero to 2 ×1012 cm − 3. The presence of plasma tends to raise the TM01 mode cut-off frequency (14 GHz at 2 ×1012 cm − 3 plasma density) relative to the vacuum cut-off frequency (5 GHz) which also causes a decrease in the group velocity everywhere, resulting in a flattening of the dispersion relation. With the introduction of plasma, an enhancement in absolute instability was observed.  相似文献   

9.
A simple, rapid, sensitive and selective method for simultaneously determining xanthopterin and isoxanthopterin content in human urine has been developed using synchronous fluorescence spectroscopy based on their intrinsic fluorescence. The synchronous fluorescence spectra were obtained with Δλ = 65 nm in a pH 8.5 KH2PO4-NaOH buffer solution. The detected wavelengths of quantitative analysis were set at 410 nm for xanthopterin and 325 nm for isoxanthopterin, respectively. Pretreatment of urine samples only was filtrated through a 0.45 μm membrane filter, which was free from the tedious separation procedures. Under optimized conditions, the limits of detection (LOD) were 0.94 ng/mL for xanthopterin and 0.48 ng/mL for isoxanthopterin. The recoveries ranged from 88.0% to 103.8 % for healthy and cancer urine samples, with coefficient of variation between 2.09% and 7.06%. The proposed method has been successfully applied to the simultaneous analysis for xanthopterin and isoxanthopterin in human urine. The results showed that the average level of isoxanthopterin was significantly elevated in urine excreted by stomach cancer patients (P < 0.01), while no significant change of xanthopterin level was found between stomach cancer patients and healthy individuals. This potentially indicates that an increase in amounts of isoxanthopterin can be associated with the presence of stomach cancer.  相似文献   

10.
A novel flow injection-gas-diffusion (GD-FI) system has been developed for the on-line analysis of ammonium ion in waters with fluorimetric detection, using an acceptor solution containing the Eosin-Bluish (EB) acid-base indicator. This, together with optimization of the process of gas transfer through the membrane, increases the sensitivity of the method to a considerable extent. Under optimum conditions, it is possible to determine the analyte within the 0.02–1.5 mg l-1 range, with a limit of detection of 5 μg l-1 and relative standard deviations (n = 12, [NH4+] = 50 μg l-1 and 0.05 μg l-1) of 3.4% and 3.0% respectively. The determination rate was 15 samples per hour.  相似文献   

11.
A sensitive time- resolved luminescence method for the determination of meloxicam (MX) in methanol and in aqueous solution is described. The method is based on the luminescence sensitization of europium (Eu3+) by formation of ternary complex with MX in the presence of 1,10- phenanthroline as coligand, Tween-80 as surfactant and gadolinium ion as a co-luminescence reagent. The signal for Eu- MX-1, 10- phenanthroline is monitored at λex = 360 nm and λem = 620 nm. Optimum conditions for the formation of the complex in aqueous system were 0.01 M TRIS buffer, pH 8.0, 1,10- phenanthroline (6.0 × 10−6 M) , Gd3+ (7.0 × 10−6 M), Tween-80 (0.28%) and 1.75 mM of Eu3+ which allows the determination of 20–800 ppb of MX with limit of detection (LOD) of 7 ppb. The relative standard deviations of the method range between 0.1 and 1.1% indicating excellent reproducibility of the method. The proposed method was successfully applied for the assay of MX in pharmaceutical formulations, plasma and in urine samples. Average recoveries of 99.8 ± 1.1%, 100.2 ± 0.9% and 100.9 ± 1.1% were obtained for MX in tablet, plasma and urine sample respectively.  相似文献   

12.
In this paper, ZnSe nanoparticles, which were modified with mercaptoacetic acid (MAA), worked as novel fluorescence sensors for the quantitative determination of copper(II) and nickel(II). Under the optimal conditions, the fluorescence intensities of functionalized ZnSe nanoparticles were quenched by the addtion of copper(II) or nickel(II) ions, there were linear relationships between the relative fluorescence intensity (logF0/F) and the concentration in the range of 140–2,000 μg/L for copper(II) (R = 0.9973) and 30–1,000 μg/L for nickel(II) (R = 0.9992), the limits of detection were 50 μg/L and 5 μg/L, respectively.  相似文献   

13.
The use of ozonation for the purification of drinking water can lead to the formation of bromate. The US Environmental Protection Agency and the European Directive for human drinking water has lowered the regulatory level for bromate down to 10 μg l−1, such that methods must be developed for monitoring the formation of bromate, particularly in on-site situations. In the present work we report a fluorometric method for the determination of bromate based on the reaction with carbostyril-124, a compound that shows florescence mainly at pH values above 4 and, when bromated, generates a non-fluorescent product. The reaction can thus be used as an indirect method for determination of the ion. The proposed method, which uses the flow injection (FI) technique, allows online application and kinetic control of the variables affecting the process, together with shorter reaction times, and it provides maximum sensitivity and selectivity. Under optimum conditions, it is possible to determine the analyte within the 4–200 μg l−1 range, with a limit of detection of 0.9 μg l−1 and a relative standard deviation (n = 12, [] = 5 and 30 μg l−1) of 3.2% and 2.6% respectively. The determination rate was ten samples per hour.  相似文献   

14.
A simple, economic, selective, and stability indicating spectrofluorimetric method was developed for the determination of famotidine (FMT); is based on its reaction with 9, 10-phenanthraquinone in alkaline medium to give a highly fluorescent derivative measured at 560 nm after excitation at 283 nm. The fluorescence intensity - concentration plot was rectilinear over the concentration range of 50–600 ng/ml with minimum quantification limit (LOQ) of 13.0 ng/ml and minimum detection limit (LOD) of 4.3 ng/ml. The factors affecting the development of the fluorescence intensity of the reaction product were carefully studied and optimized. The method was applied for the determination of FMT in its dosage forms. The stability of the compound was studied, and the proposed method was found to be stability indicating one. The results obtained were in good agreement with those obtained by the official method. Furthermore, the method was applied for the determination of FMT in spiked and real human plasma. The mean % recovery (n = 4) was found to be 99.94 ± 0.24, and 105.13 ± 0.64 for spiked and real human plasma, respectively. The composition of the reaction product as well as its stability constant was also investigated. Moreover, the method was utilized to investigate the kinetics of both alkaline and oxidative induced degradation of the drug. The apparent first order rate constant and half life time of the degradation product was calculated. A proposal of the reaction pathway was postulated.  相似文献   

15.
The formation of a complex between ketoconazole and β-cyclodextrin was followed by spectrofluorimety. The inclusion of ketoconazole in β-cyclodextrin cavity enhanced the native fluorescence of the drug. The stoichiometry of the complex was 1:1 β-cyclodextrin to ketoconazole and the stability constant of the complex (log K f) was determined to be 4.3 ± 0.01 at pH = 7.9 and 3.7 ± 0.04 at pH = 2.6. A sensitive spectrofluorimetric method for the detection of ketoconazole is presented. At optimized experimental conditions, a linear relationship between the fluorescence intensity of the solution and concentration of ketoconazole is observed in the range of 0.01–10 μg ml−1 (5 × 10−8 M–1.88 × 10−5 M). The method was applied to the detection of ketoconazole in pharmaceutical products and the results were satisfactory in comparison to the official method (relative error = 2.8% and standard deviation = 0.06 for tablets of ketoconazole). The recovery of ketoconazole from a blood serum sample, determined by the proposed method, was 97.1 ± 2.4%.  相似文献   

16.
(100-x)ZrO2(x)Bi2O3 (x = 5, 10, 15) system has been synthesized by solid-state reaction technique. Tetragonal Bi7.38Zr0.62O12.31 phase has formed in all the samples after sintering at 850 °C for 24 h. Apart from this, ZrO2 and Bi2O3 are also identified as minority phases. The volume fraction of Bi7.38Zr0.62O12.31 phase increases with increasing concentration of Bi2O3. The AC conductivity plots exhibit phase transition at 570 °C and 460 °C for x = 10 and x = 15 samples, respectively. The maximum conductivity is observed (1.60 mS/cm) in x = 15 sample. These results are correlated and supported with microstructural and thermal analysis.  相似文献   

17.
Based on the micelle synergism mechanism, a simple and sensitive flow injection chemiluminescence (FI-CL) method for the assay of lornoxicam was described. The CL signal generated from the reaction of Ce (IV) with lornoxicam in acidic solution was very weak, while the interfusion of sodium dodecyl benzene sulfonate (SDBS) resulted in a highly CL intensity. Under the optimum experimental conditions, the CL intensity was proportional to lornoxicam concentration over the range 1.0 × 10−10–7.3 × 10−8 g/mL with a detection limit of 4.9 × 10−11 g/mL (3σ). The relative standard deviation for 11 replicate measurements of 3.0 × 10−9 g/mL of lornoxicam was 1.9%. The proposed method was successfully applied for the assay of lornoxicam in pharmaceuticals, human serum and urine with excellent recovery. The possible mechanism of CL reaction was also discussed briefly.  相似文献   

18.
Flow cytometry provides a rapid and high-content multiparameter analysis of individual microorganisms within a population. In the past years, several fluorescent stains were developed in order to monitor DNA content distribution and cell-cycle phases, mainly in eukaryotic cells. Recently, due to its low detection limits, several of these fluorescent stains were also applied to prokaryotic cells. In this study, the ability of a novel far-red fluorescent stain DRAQ5 in assessing intracellular DNA content distribution in Escherichia coli DH5α was evaluated. The results showed that a DRAQ5-labelled live E. coli suspension can be obtained by incubation of 1 × 106 cells/mL with 5 μM DRAQ5 in PBS buffer supplemented with EDTA (pH = 7.4) during 30 min at 37 °C. Flow cytometric analysis of fixed E. coli cells revealed that ethanol should be used in detriment of glutaraldehyde for DRAQ5 labelling. After the analysis of RNase and DNase digested samples, DRAQ5 was proven to be a specific DNA labelling stain. The present study demonstrates that the use of DRAQ5 as a DNA-labelling stain provides an easy assessment of intracellular DNA content and cell-cycle phases in Gram-negative bacteria such as E. coli.  相似文献   

19.
In the Friedmann cosmology, the deceleration of the expansion q plays a fundamental role. We derive the deceleration as a function of redshift q(z) in two scenarios: ΛCDM model and modified Chaplygin gas (MCG) model. The function for the MCG model is then fitted to the cosmological data in order to obtain the cosmological parameters that minimize χ 2. We use the Fisher matrix to construct the covariance matrix of our parameters and reconstruct the q(z) function. We use Supernovae Ia, WMAP5, and BAO measurements to obtain the observational constraints. We determined the present acceleration as q 0 = − 0.65 ±0.19 for the MCG model using the Union2 dataset of SNeIa, BAO, and CMB and q 0 = − 0.67 ±0.17 for the Constitution dataset, BAO and CMB. The transition redshift from deceleration to acceleration was found to be around 0.80 for both datasets. We have also determined the dark energy parameter for the MCG model: Ω X0 = 0.81 ±0.03 for the Union2 dataset and Ω X0 = 0.83 ±0.03 using the Constitution dataset.  相似文献   

20.
The photophysics and cyclic voltammetry of two novel phosphorescent thiones, 2,2-dimethyl-indan-1-one-3-thione (DMIKT) and 2,2-dimethyl-indan-1,3-dithione (DMIDT), and three known phosphorescent thiones, 4H-pyran-4-thione (PT), 4H-1-benzopyran-4-thione (BPT) and 2,2-dimethylindan-1-thione (DMIT), have been characterised and compared. The phosphorescence emission of DMIT, DMIKT and DMIDT extends from the red into the near-IR spectral region. The additional carbonyl or thione group of DMIKT and DMIDT causes a significant shift in the emission maxima to 680 nm compared to that of DMIT, at 637 nm, in perfluorinated hydrocarbons. In acetonitrile the emission maxima of DMIKT and DMIDT are at 696 and 706 nm, respectively, and the spectra show vibronic bands which extend out beyond 850 nm. There is a significant reduction in triplet lifetime along this series (from 44 (±2) μs (DMIT) to 10 ((±0.8) μs (DMIKT) in perfluorinated solvents, and 8.6 (±0.5) (DMIT), 1.3 (±0.5) (DMIKT) and 0.35 (±0.07) μs (DMIDT) in acetonitrile), as well as a reduction in the rate constant for ground-state quenching of the triplet, (from 9.8 ((±0.9) to 3.5 ((±0.6) and 1.3 ((±0.2) × 109 mol−1 dm3 s−1 for the same compounds). The addition of the C=O or C=S groups also causes a decrease in phosphorescence quantum yield with the highest emission quantum yield obtained for DMIT (Φ P = 0.149 (±0.015)). Electrochemical studies show that while PT and BPT exhibit irreversible redox behaviour, DMIT, DMIKT and DMIDT all show at least one reversible reduction wave attributed to a one-electron process centred on the C=S moiety. The suitability of these lumophores for use in OLEDs is discussed.  相似文献   