首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The aim of this study was to investigate the correlation between levels of a marker of oxidative DNA damage, 8-hydroxy-2′-deoxyguanosine (8-OHdG), in human saliva and urine, and to explore its potential application in fast diagnosis of many diseases (especially cancer) associated with oxidative damage. A simple and time-efficient method, based on capillary electrophoresis with electrochemical detection, was developed for the determination of salivary and urinary 8-OHdG. Under the optimum conditions, 8-OHdG and its coexisting analytes could be well separated within 16 min at a voltage of 14 kV in 60 mmol L?1 borax running buffer (pH 8.2). A good linear relationship was established between peak current and concentration of analytes over three orders of magnitude with detection limits (S/N = 3) ranging from 0.41 × 10?7 to 2.50 × 10?7 mol L?1 for all analytes.  相似文献   

2.
Liquid chromatography with amperometric detection (LC-AD) is developed and applied to simultaneously determine five aromatic amines. In the LC-AD, a new carbon nanotubes/poly(3-methylthiophene) modified dual-electrode is fabricated and then used as the working electrode. It is found that this chemically modified electrode (CME) exhibits efficiently electrocatalytic oxidation for aromatic amines with relatively high sensitivity, stability and long-life. Thus, lower detection in LC-AD can be achieved, which are 4.0 × 10–8 mol L–1 for aniline, 1.6 ×10–7 mol L–1 for 4-nitroaniline, 1.0 × 10–7 mol L–1 for 4-chloroaniline, 1.5 × 10–7 mol L–1 for 1-naphthylamine, 1.7 × 10–7 mol L–1 for 2-bromoaniline. The recoveries of the five analytes are also determined, which range between 0.95 and 1.05 for drinking water, 0.86 and 1.10 for the LiWa River water.  相似文献   

3.
A novel organic gel film modified electrode was simply and conveniently fabricated by casting LixMoOy and polypropylene carbonate (PPC) onto the surface of a gold electrode. The cyclic voltammetry and amperometry studies demonstrated that the LixMoOy film modified electrode has a high stability and a good electrocatalytic activity for the reduction of iodate. In amperometry, a good linear relationship between the steady current and the concentration of iodate was obtained in the range from 3×10–7 to 1×10–4 mol L–1 with a correlation coefficient of 0.9997 and a detection limit of 1×10–7 mol L–1.  相似文献   

4.
A chemiluminescence signal at 425 nm was observed when ferric state myoglobin was mixed with luminol in alkaline medium. Because the signal was remarkably enhanced in the presence of Fe(CN)6 4–, analytical applications were investigated in a flow-injection system. The increase in chemiluminescence was linearly dependent on myoglobin concentration in the range 0.1 to 100 nmol L–1, and the limit of detection was 0.04 nmol L–1 with relative standard deviation 3.2% (3). It was also found that binding of Mb with the ligands CN, SCN, and F significantly inhibited the chemiluminescence reaction. The linear dynamic ranges for the ligands were 1.0–300.0, 0.1–3.0, and 0.5–100.0 nmol L–1, and the limits of detection (S/N=3) 0.4, 0.04, and 0.2 nmol L–1, for F, CN, and SCN, respectively. The relative standard deviations were 5.32%, 6.13%, and 3.38% for 0.1 nmol L–1 CN, 0.5 nmol L–1 SCN, and 1.0 nmol L–1 F, respectively. At a flow rate of 2.0 mL min–1 the assay could be accomplished in 1 min, including sampling and washing. The method has been successfully applied to the determination of myoglobin in human urine and F in water samples. A possible mechanism of chemiluminescence production by myoglobin and luminol is presented.  相似文献   

5.
A novel procedure has been developed for spectrophotometric determination of anionic surfactants in water using a solenoid micro-pump as fluid-propulsion device. The proposed method is based on substitution of methyl orange (MO) by anionic surfactants in the formation of an ion-pair with the cetyl pyridine ion (CPC+) at pH 5.0. The flow network comprised four solenoid micro-pumps which, under microcomputer control, enabled sample and reagent introduction, and homogenisation in the reaction zone. The system is flexible and simple to operate and control, and sensitive and precise. The analytical plot for the anionic surfactant was linear between 1.43×10–6 and 1.43×10–5 mol L–1 (0.5 to 5.0 mg L–1; R=0.997, n=5). The relative standard deviation was 0.8% (n=11) for a sample containing 5.74×10–6 mol L–1 (2 mg L–1) surfactant. The limit of detection was 9.76×10–8 mol L–1 (0.034 mg L–1) and the sampling throughput was 60 determinations per hour. The results obtained for washing-water samples were comparable with those obtained by use of the reference method, and no significant differences at the 95% confidence level were observed.  相似文献   

6.
We report the electroanalytical determination of lead by anodic stripping voltammetry at in-situ-formed, bismuth-film-modified, boron-doped diamond electrodes. Detection limits in 0.1 mol L–1 nitric acid solution of 9.6x10–8 mol L–1 (0.2 ppb) and 1.1x10–8 mol L–1 (2.3 ppb) were obtained after 60 and 300 s deposition times, respectively. An acoustically assisted deposition procedure was also investigated and found to result in improved limits of detection of 2.6×10–8 mol L–1 (5.4 ppb) and 8.5×10–10 mol L–1 (0.18 ppb) for 60 and 300 s accumulation times, respectively. Furthermore, the sensitivity obtained under quiescent and insonated conditions increased from 5.5 (quiescent) to 76.7 A mol–1 L (insonated) for 60 s accumulation and from 25.8 (quiescent) to 317.6 A mol–1 L (insonated) for 300 s accumulation. Investigation of the use of ultrasound with diluted blood revealed detection limits of the order of 10–8 mol L–1 were achievable with excellent inter- and intra-reproducibility and sensitivity of 411.9 A mol–1 L . For the first time, electroanalytical detection of lead in diluted blood is shown to be possible by use of insonated in-situ-formed bismuth-film-modified boron-doped diamond electrodes. This method is a rapid, sensitive, and non-toxic means of clinical sensing of lead in whole human blood.  相似文献   

7.
A sensitive and efficient flow-injection (FI) preconcentration and matrix-separation technique coupled to sector field ICP–mass spectrometry (SF-ICP–MS) has been developed and validated for simultaneous determination of ultra-low levels of uranium (U) and thorium (Th) in human urine. The method is based on selective retention of U and Th from a urine matrix, after microwave digestion, on an extraction chromatographic TRU resin, as an alternative to U/TEVA resin, and their subsequent elution with ammonium oxalate. Using a 10 mL sample, the limits of detection achieved for 238U and 232Th were 0.02 and 0.03 ng L–1, respectively. The accuracy of the method was checked by spike-recovery measurements. Levels of U and Th in human urine were found to be in the ranges 1.86–5.50 and 0.176–2.35 ng L–1, respectively, well in agreement with levels considered normal for non-occupationally exposed persons. The precision obtained for five replicate measurements of a urine sample was 2 and 3% for U and Th, respectively. The method also enables on-line measurements of the 235U/238U isotope ratios in urine. Precision of 0.82–1.04% (RSD) was obtained for 235U/238U at low ng L–1 levels, using the FI transient signal approach.  相似文献   

8.
A new microcomposite with copper(II) complex and carbon paste (CuC/CPE) was developed to determine the uric acid (UA) content in the presence of dopamine (DP) and was characterized via cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and energy dispersive spectroscopy (EDS). The results showed high selectivity for UA compared with DP because the anodic peak currents for DP were near those of a CPE without Cuc and were considerably increased for UA. The UA and DP increases were 86.9 % and 14.3 %, respectively, according to CV and 96.6 % and 25.5 %, respectively, according to square wave voltammetry (SWV) with the CuC/CPE. Moreover, the anodic peak separation for UA and DP was 0.17 V. With optimal parameters (pH, 3.3; adsorption time(tADS), 30 s;adsorption potential (EADS), 0.10 V), the anodic peak currents for UA were proportional to concentrations between 1.6 and 14.4 μmol L?1 using standard solutions with UA concentrations ranging from 8.0–40.5 μmol L?1 and real samples. The UA detection limit was 0.13 μmol L?1. The new sensor was used to determine the UA contentin human urine samples, and the method was checked with a urine chemistry control from Bio‐Rad based on human urine spiked with quantities of UA and showed a recovery between 84 % and 106 % at concentrations below 10.0 μmol L?1.  相似文献   

9.
In the absence of any special luminescence reagent, emission of weak chemiluminescence has been observed during the decomposition of hydrogen peroxide catalyzed by copper(II) in basic aqueous solution. The intensity of the chemiluminescence was greatly enhanced by addition of DNA and was strongly dependent on DNA concentration. Based on these phenomena, a flow-injection chemiluminescence method was established for determination of DNA. The chemiluminescence intensity was linear with DNA concentration in the range 2×10–7–1×10–5 g L–1 and the detection limit was 4.1×10–8 g L–1 (S/N=3). The relative standard deviation was less than 3.0% for 4×10–7 g L–1 DNA (n=11). The proposed method was satisfactorily applied for determination of DNA in synthetic samples. The possible mechanism of the CL reaction is discussed.  相似文献   

10.
Procedures for trace cobalt determinations by adsorptive stripping voltammetry at in situ and ex situ plated bismuth film electrodes are presented. These exploit the enhancement of the cobalt peak obtained by using the Co(II)–dimethylglyoxime–cetyltrimethylammonium bromide–piperazine-N,N-bis(2-ethanesulfonic acid) system. The calibration graph for an accumulation time of 120 s was linear from 2 × 10–10 to 2 × 10–8 mol L–1. The relative standard deviation from five determinations of cobalt at a concentration of 5 × 10–9 mol L–1 was 5.2%. The detection limit for an accumulation time of 300 s was 1.8 × 10–11 mol L–1. The proposed procedure was applied to cobalt determination in certified reference materials and in tap and river water samples.  相似文献   

11.
《Electroanalysis》2018,30(8):1870-1879
A portable electroanalytical system applied for rapid and simultaneous determination of uric acid (UA) and nitrite (NIT) in human biological fluids (urine, saliva and blood) is reported. The system is based on batch‐injection analysis with multiple‐pulse amperometric (BIA‐MPA) detection using screen‐printed electrodes (SPEs) modified with multi‐walled carbon nanotubes. Sample dilution in optimized electrolyte (0.1 mol L−1 Britton‐Robinson buffer pH 2) followed by injection of 100 μL on the electrode surface using an electronic micropipette is performed. UA is detected at +0.45 V and both UA+NIT at +0.70 V. Linear calibration plots for UA and NIT were obtained over the range of 1–500 μmol L−1 with detection limits of 0.05 and 0.06 μmol L−1, respectively. For comparison, a differential‐pulse voltammetric (DPV) method was optimized, and linear calibration plots for UA and NIT were obtained over range of 1–30 μmol L−1 and 1–40 μmol L−1 with detection limits of 0.1 and 0.3 μmol L−1, respectively. BIA‐MPA is highly precise (RSD<1.3 %), fast (160 h−1) and free from sample‐matrix interferences as recovery values ranged from 77 to 121 % for spiked samples (short contact time of sample aliquot with SPE). Contrarily, recovery tests conducted using DPV did not provide adequate recovery values (>150 %), probably due to the longer contact time of the SPE with the biological samples during analysis leading to a severe interference of sample matrices.  相似文献   

12.
A capillary zone electrophoresis (CZE) method has been developed for simultaneous assay of two bioactive components (p-tyrosol and salidroside) in Rhodiola crenulata and Rhodiola kirilowii for the first time. Those analytes were successfully separated within 15 min using 50 mmol L–1 (pH 9.62) borate containing 30% methanol as running buffer. Regression equations revealed linear relationships (correlation coefficients 0.9998–0.9999) between peak area and concentration of the two analytes. The relative standard deviations (RSD) of the migration times and the peak areas of two constituents ranged from 0.51 to 0.57% and from 0.65 to 1.17%, respectively, intra-day, and from 4.91 to 6.93% and from 3.51 to 5.33%, respectively, inter-day. The recoveries of two constituents ranged from 96.24 to 103.15%.  相似文献   

13.
Use of square-wave voltammetry (SWV) for determination of cefoperazone (CFPZ) in some buffers, bacterial culture, urine, and milk is described. CFPZ provides a specific voltammetric signal which is affected by pH and solution components. Determination of CFPZ in Britton–Robinson buffer, pH 4.4, is sensitive with a low detection limit (about 0.5 nmol L–1). In a more complex medium (bacterial 2YT medium, pH 7.2) the detection limit was approximately 1.5 mol L–1. We provide evidence that SWV is a suitable and quick method for CFPZ determination in a culture of living bacteria without separation of biomass. We have found big differences between methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-sensitive Staphylococcus aureus (MSSA) in cultivation in the presence of CFPZ, depending on time. When CFPZ is cleaved by penicillinase, a new SWV peak b appears at more positive potentials. This peak rises both with increasing concentration of enzyme and with cleavage time while the original CFPZ peak is simultaneously decreasing. We determined the concentration of CFPZ in the drug Pathozone by the standard addition method and achieved good agreement with the declared value of CFPZ in the drug. With a simple pretreatment procedure it is possible to determine CFPZ in milk; for urine no pretreatment was required. Using SWV we could detect CFPZ concentrations as low as 500 nmol L–1 in bovine milk and human urine.  相似文献   

14.
A new, simple, rapid, and sensitive spectrophotometric method has been developed for the determination of manganese in sewage. The method is based on the reaction of manganese with derivatives of 1,3,3-trimethyl-2-[3-(1,3,3-trimethyl-1,3-H-indol-2-ylidene)propenyl]-3H-indolium to form a colored ion associate with a sensitive absorption maximum at 560 nm. The appropriate reaction conditions have been established: pH 8.5–10.0, 1.25–2.3×10–3 mol L–1 1-nitroso-2-naphthol, and 1.6–2.4×10–4 mol L–1 dye reagent. Beer's law is obeyed for manganese concentrations up to 4.2 mg L–1. The limit of detection is 0.01 mg L–1 Mn2+; the molar absorptivity of the ion associate was 7.5×104 L mol–1 cm–1. The effect of various foreign ions was examined. A reaction mechanism is suggested. The developed procedure was tested for determination of manganese in sewage with satisfactory precision and accuracy.  相似文献   

15.
A rapid HPLC method for the determination of carboxylic acids in urine samples using a Chromolith Performance RP/18e 100/4.6 with Chromolith Guard Cartridge RP/18e 10/4.6 (Merck KgaA, Darmstadt, Germany) was developed. The method facilitates the simultaneous determination of aromatic hydrocarbon metabolites mandelic acid (MA) and phenylglyoxylic acid (PGA) from styrene and ethylbenzene, hippuric acid (HA) from toluene and 2-, 3-, 4-methylhippuric acids (MHA) from xylene. 3-Hydroxybenzoic acid (3-HBA) was used as internal standard. A chromatographic run is completed within less than 5 min for styrene, ethylbenzene and toluene metabolites, and within 10 min for xylene metabolites. The detection limits are 9 mg L–1 urine for MA, 1.25 mg L–1 urine for PGA, 4.9 mg L–1 urine for HA, 22 mg L–1 urine for 2-MHA, and 18.5 mg L–1 urine for 3-MHA.No significant differences of the MA, PGA and HA concentrations in human urine samples obtained by HPLC chromatography on LiChrosorb RP 18 and on Chromolith RP/18e columns were found. The results were evaluated by using ANOVA.Abbreviations MA mandelic acid - PGA phenylglyoxylic acid - HA hippuric acid - MHA methylhippuric acid - 3-HBA 3-hydroxybenzoic acid - ANOVA analyses of variance - GC gas chromatography - HPLC high-performance liquid chromatography  相似文献   

16.
A high-performance capillary electrophoresis with electrochemical detection (CE-ED) method has been employed for the determination of six bioactive ingredients in traditional Chinese herbs, Herba cepbalanoplosis segeti and Herba cirsii japonici. The effects of several factors such as the acidity and concentration of running buffer, the separation voltage, the applied potential and the injection time on CE-ED were investigated. Under the optimum conditions, the six analytes could be well separated within 21 min in a 75 cm length capillary at the separation voltage of 15 kV in a 50 mmol L–1 borax running buffer (pH 8.4). A 300 m diameter carbon disk electrode was used as the working electrode positioned carefully opposite the outlet of the capillary in a wall-jet configuration at potential of +950 mV (vs. SCE). Good linear relationship was established between peak current and concentration of analytes over two orders of magnitude with detection limits (S/N=3) ranged from 1.5×10–7 to 6.0×10–7 g mL–1 for all six analytes. This proposed method has been successfully applied for the analysis of traditional Chinese herbs after a relatively simple extraction procedure, further on, for the differentiation of these above two seemingly identical herbs based on their electropherograms or characteristic electrochemical profiles.  相似文献   

17.
Summary Ethanol has been found extractable from human whole blood and urine samples by headspace solid-phase micro extraction (SPME) with a Carbowax/divinylbenzene-coated fiber. After heating a vial containing the body fluid sample with ethanol, and isobutanol as internal standard (IS) at 70°C in the presence of (NH4)2SO4, a Carbowax/divinylbenzene-coated SPME fiber was exposed in the headspace of the vial to allow adsorption of the compounds. The fiber needle was then injected into a middle-bore capillary gas chromatography (GC) port. The headspace SPME-GC gave intense peaks for both compounds; a small amount of background noises appeared, but did not interfere with the detection of the compounds. Recoveries of ethanol and IS were 0.049 and 0.026% for whole blood, respectively, and 0.054 and 0.085% for urine, respectively. The calibration curves for ethanol showed excellent linearity in the range of 80–5000 mg L–1 for whole blood and 40–5000 mg L–1 for urine; the detection limits for both samples were 20 and 10 mg L–1, respectively. The data on actual determination of ethanol after the drinking of beer are also presented for two subjects.  相似文献   

18.
Accumulation of selected cephalosporin antibiotics cefazolin, cefotaxime, cefuroxime and ceftriaxone on hanging mercury drop electrode was studied. The effects of supporting electrolyte composition, pH, accumulation potential and time were examined and corresponding analytical parameters were established employing linear sweep (staircase) or differential pulse voltammetric detection. Britton-Robinson buffer of pH 4.0 for ceftriaxone and acetate buffer in the pH range 3.6–5.0 for the other three compounds were found to be the best media. Calibration curves were linear from micromolar down to nanomolar range with limits of detection 2 × 10–9 moll–1, 1 × 10–9 moll–1, 5 × 10–10 moll–1 and 5 × 10–9 moll–1 for cefazolin, cefotaxime, cefuroxime and ceftriaxone respectively, applying the accumulation times of 5 to 14 min. Direct and simple determination of cefazolin as a model compound in urine was established with no other manipulation of urine sample than dilution 1 + 500 with buffer and subsequent adsorptive stripping voltammetric determination. The detection limit of the method is 7 gml–1 (1.5 × 10–5 moll–1) of cefazolin in urine, and the relative standard deviation of 9 measurements was found to be 2.8% at 23 gml–1 of cefazolin in urine. Similar values were found for other three compounds as well. These values are comparable or even better than those obtained by high performance liquid Chromatographic methods and approve the suitability of the proposed method for urine level monitoring in clinical practice and pharmacological studies.  相似文献   

19.
A sensitive procedure for determination of micro-traces of Co(II) by adsorptive stripping voltammetry is proposed. The procedure exploits the enhancement of the cobalt peak obtained by use of the system Co(II)–dimethylglyoxime–piperazine-1,4-bis(2-ethanesulfonic acid)–cetyltrimethylammonium bromide. Using the optimized conditions, a detection limit (based on the 3 criterion) for Co(II) of 1.2×10–11 mol L–1 (0.7 ng L–1) was achieved. The calibration plot for an accumulation time of 30 s was linear from 5×10–11 to 4×10–9 mol L–1. The procedure was validated by analysis of certified reference materials and natural water samples.  相似文献   

20.
The presence of elevated uric acid (UA) levels is a sign of gout, that is, hyperuricemia. In this study the monitoring of the UA levels in less‐invasive biological samples, such as the human fingernail, is suggested for the diagnosis and therapy of gout. Twenty‐six healthy volunteers (HV) and 22 gout patients (GP) were studied. The UA was extracted from human fingernail samples, then separated on an Inertsil ODS‐3 column (250 × 4.6 mm i.d., 4.0 μm, GL Sciences) by isocratic elution using methanol–74 mm phosphate buffer (pH 2.2) 2:98 (v/v). A UV detector was used to monitor the samples at 284 nm. Using the developed method, different UA concentrations were found in the GP and HV. When comparing the concentrations from GP with those from HV, a statistically significant correlation was observed between the UA (p < 0.01). In this study, the UA was confirmed as a potential biomarker for the diagnosis and therapy of gout. We have developed a novel sensitive, and simple method for the determination of UA in the fingernails of GP and HV. The human fingernail may serve as a noninvasive biosample for the diagnosis of gout. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号