首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 797 毫秒
1.
Summary.  A new selective, sensitive, and simple kinetic method is developed for the determination of trace amounts of iodide. The method is based on the catalytic effect of iodide on the reaction of triflupromazine (TFP) with H2O2. The reaction is followed spectrophotometrically by tracing the oxidation product at 498 nm within 1 min after addition of H2O2. The optimum reaction conditions are TFP (0.4 × 10−3 M), H2SO4 (1.0M), H3PO4 (2.0M), and H2O2 (1.6M) at 30°C. Following this procedure, iodide can be determined with a linear calibration graph up to 4.5 ng ċ cm−3 and a detection limit of 0.04 ng ċ cm−3, based on the 3 Sb criterion. The method can also be applied to the determination of iodate and periodate ions. Determination of as little as 0.2, 1.0, 2.0, and 4.0 ng ċ cm−3 of I, IO3 -, or IO4 - in aqueous solutions gave an average recovery of 98% with relative standard deviations below 1.6% (n = 5). The method was applied to the determination of iodide in Nile river water and ground waters as well as in various food samples after alkaline ashing treatment. The method is compared with other catalytic spectrophotometric procedures for iodide determination. Received January 19, 2001. Accepted (revised) March 12, 2001  相似文献   

2.
 A new selective, sensitive, and simple kinetic method is developed for the determination of trace amounts of iodide. The method is based on the catalytic effect of iodide on the reaction of triflupromazine (TFP) with H2O2. The reaction is followed spectrophotometrically by tracing the oxidation product at 498 nm within 1 min after addition of H2O2. The optimum reaction conditions are TFP (0.4 × 10−3 M), H2SO4 (1.0M), H3PO4 (2.0M), and H2O2 (1.6M) at 30°C. Following this procedure, iodide can be determined with a linear calibration graph up to 4.5 ng ċ cm−3 and a detection limit of 0.04 ng ċ cm−3, based on the 3 Sb criterion. The method can also be applied to the determination of iodate and periodate ions. Determination of as little as 0.2, 1.0, 2.0, and 4.0 ng ċ cm−3 of I, IO3 -, or IO4 - in aqueous solutions gave an average recovery of 98% with relative standard deviations below 1.6% (n = 5). The method was applied to the determination of iodide in Nile river water and ground waters as well as in various food samples after alkaline ashing treatment. The method is compared with other catalytic spectrophotometric procedures for iodide determination.  相似文献   

3.
Summary.  A simple and rapid derivative spectrophotometric assay procedure is described for the analysis of caffeine (1), acetaminophen (2), and propyphenazone (3) in tablet formulations. The concentration range of application is 5.0–25.0 μg·cm−3 for 2 and 3 and 1.0–5.0 μg·cm−3 for 1. The method involves the extraction of the drugs from tablets with 0.1 N H2SO4, filtration, appropriate dilution, and measurement of the fourth derivative absorbance values at zero crossing wavelengths of 230.0, 263.2, and 256.6 nm for 1, 2, and 3. As a reference method, a reversed phase HPLC procedure was developed. Commercially available tablets were analyzed; statistical comparison of the results with those obtained from the reference method showed good agreement. The derivative spectrophotometric method has the advantage of being simple, rapid, inexpensive, and easy to perform. Received April 18, 2001. Accepted (revised) June 5, 2001  相似文献   

4.
 A simple and rapid derivative spectrophotometric assay procedure is described for the analysis of caffeine (1), acetaminophen (2), and propyphenazone (3) in tablet formulations. The concentration range of application is 5.0–25.0 μg·cm−3 for 2 and 3 and 1.0–5.0 μg·cm−3 for 1. The method involves the extraction of the drugs from tablets with 0.1 N H2SO4, filtration, appropriate dilution, and measurement of the fourth derivative absorbance values at zero crossing wavelengths of 230.0, 263.2, and 256.6 nm for 1, 2, and 3. As a reference method, a reversed phase HPLC procedure was developed. Commercially available tablets were analyzed; statistical comparison of the results with those obtained from the reference method showed good agreement. The derivative spectrophotometric method has the advantage of being simple, rapid, inexpensive, and easy to perform.  相似文献   

5.
A simple, rapid and specific chemiluminescence (CL) method for the determination of glutathione has been developed. The method is based on the enhanced CL of the reaction between Ru(phen)3 2+ (phen = 1,10-phenanthroline) and KMnO4 by glutathione in HCl medium. Under the optimum conditions, the response is linearly proportional to the concentration of glutathione between 1.5 × 10−7 and 1.0 × 10−5 mol L−1. The dection limit for glutathione (5.8 × 10−8 mol L−1) is about 10 and 200 times better than those of the spectrophotometric method using Ellman regent and the Lucigenin – CL method, respectively. The final procedure allows the determination of glutathione in human serum with recoveries of 92%–108%. A satisfactory agreement was obtained with a mean relative difference of 2.5% compared to the HPLC method.  相似文献   

6.
A novel flow injection procedure has been developed for the determination of tannic acid based on the inhibition of the chemiluminescences in luminol-H2O2-Manganese tetrasulfonatophthalocyanine (MnTSPc) system by tannic acid. The method is simple, rapid and sensitive with a detection limit of 8 × 10−10 mol·L−1 and a linear range of 7 × 10−9–5 × 10−6 mol·L−1. The relative standard deviation is 1.9% for eleven measurements of 5 × 10−7 mol·L−1 tannic acid. The method has been successfully applied to the determination of tannic acid in real Chinese gall and hop pellets samples.  相似文献   

7.
 A selective, sensitive and simple catalytic method is developed for the determination of vanadium in natural and highly polluted waste waters. The method is based on the catalytic effect of VV and/or VIV on the bromate oxidative-coupling reaction of metol with phloroglucinol (PG). The reaction is followed spectrophotometrically by tracing the oxidation product at 464 nm after 10 minutes of mixing the reagents. The optimum reaction conditions are metol (8.0×10−3 M), PG (4.0×10−3 M) and bromate (2×10−2 M) at 35°C and in presence of an activator-b uffer mixture of 5×10−2 M of each of citric and monochloroacetic acids (pH 2.40). Following the recommended procedure, vanadium can be determined with a linear calibration graph up to 8.0 ng mL−1 and a detection limit, based on the 3sb criterion, of 0.1 ng mL−1. Spectrophotometric determination of as little as 1.0 ng mL−1 of VV or VIV in aqueous solutions gave an average recovery of 98% with relative standard deviations of ?1.8% (n = 5). The proposed method was directly applied to the determination of vanadium in Nile river water and highly polluted industrial wastes. Statistical treatments of analytical results could not detect any systematic error and showed the high accuracy and precision of the developed method. Received November 25, 1999. Revision March 10, 2000.  相似文献   

8.
A simple, sensitive, selective, and low-cost method is proposed for rapidly determining nitric oxide (NO) in some rat tissues. Polymer monolith microextraction (PMME) using a poly(methacrylic acid–ethylene glycol dimethacrylate) (MAA-EGDMA) monolithic column was combined with derivatization of NO using 1,3,5,7-tetramethyl-8-(3′,4′-diaminophenyl)-difluoroboradiaza-s-indacene (TMDABODIPY), and this was used to analyze the derivatives of NO by high-performance liquid chromatography (HPLC) with fluorescence detection at λ ex/λ em = 498/507 nm. The baseline separation of TMDABODIPY and its NO derivative is performed under simple conditions in which a C18 column is used and eluted with 50 mmol L−1 ethanolamine and methanol. The conditions for the extraction of NO derivatives were optimized. The limit of detection of NO was 2 × 10−12 mol L−1 (S/N = 3). The linearity range of the method was 9 × 10−11−4.5 × 10−8 mol L−1. The interday and intraday relative standard deviations were less than 5%. The proposed method was successfully applied to the determination of NO levels in some rat tissue samples including heart, kidney, and liver with recoveries varying from 87.1 to 95.2%.  相似文献   

9.
Summary.  A highly selective, sensitive, and simple catalytic method for the determination of molybdenum in natural and waste waters was developed. It is based on the catalytic effect of Mo(VI) on the oxidation of 2-aminophenol with H2O2. The reaction is monitored spectrophotometrically by tracing the oxidation product at 430 nm after 10 min of mixing the reagents. Addition of 800 μg · cm−3 EDTA conferred high selectivity; however, interfering effects of Au(III), Cr(III), Cr(VI), and Fe(III) had to be eliminated by a reduction and co-precipitation procedure with SnCl2 and Al(OH)3. Mo(VI) shows a linear calibration graph up to 11.0 ng · cm−3; the detection limit, based on the 3S b-criterion, is 0.10 ng · cm−3. The unique selectivity and sensitivity of the new method allowed its direct application to the determination of Mo(VI) in natural and waste waters. Received April 11, 2001. Accepted (revised) June 18, 2001  相似文献   

10.
In weakly acidic buffer medium, vitamin B1 (VB1) interacts with gold nanoparticles to form a binding product, which resulted in a significant enhancement of resonance Rayleigh scattering (RRS) intensity and the appearance of a new RRS spectrum. The maximum RRS peak was at 368 nm, and there are three smaller scattering peaks that were at 284 nm, 440 nm and 495 nm, respectively. The enhanced RRS intensity (ΔI) was directly proportional to the concentration of VB1 in the range of 0–2.8 × 10−7 mol L−1. The method had high sensitivity and its detection limit (3σ) was 0.9 ng mL−1. The optimum conditions and the influencing factors have been investigated. The method had good selectivity, which could be observed from the influence of coexisting substances. A sensitive, simple and fast RRS method for the determination of VB1 with gold nanoparticle probe has been developed. In addition, the reasons for RRS enhancement were discussed.  相似文献   

11.
A new method for the evaluation of one- and two-centre magnetic and electric multipole integrals for Slater-type functions is presented. The method is strictly analytical in that no approximations of any kind are involved. Two simple functions, ℐ1 aug and ℐ2 aug, are introduced, which employ only functions that are well known in electronic structure theory. With the use of augmentation exponents these functions apply to multipole integrals as well as other one-electron integrals, such as nuclear attraction integrals. The proposed method includes the analytic determination of derivatives of the integrals with respect to atomic displacements. Some illustrative test calculations are presented and compared to results from the literature. Received: 20 April 1998 / Accepted: 13 October 1998 / Published online: 1 February 1999  相似文献   

12.
There is a lack of fundamental knowledge about the scale up of biosurfactant production. In order to develop suitable technology of commercialization, carrying out tests in shake flasks and bioreactors was essential. A reactor with integrated foam collector was designed for biosurfactant production using Bacillus subtilis isolated from agricultural soil. The yield of biosurfactant on biomass (Y p/x), biosurfactant on sucrose (Y p/s), and the volumetric production rate (Y) for shake flask were obtained about 0.45 g g−1, 0.18 g g−1, and 0.03 g l−1 h−1, respectively. The best condition for bioreactor was 300 rpm and 1.5 vvm, giving Y x/s, Y p/x, Y p/s, and Y of 0.42 g g−1, 0.595 g g−1, 0.25 g g−1, and 0.057 g l−1 h−1, respectively. The biosurfactant maximum production, 2.5 g l−1, was reached in 44 h of growth, which was 28% better than the shake flask. The obtained volumetric oxygen transfer coefficient (K L a) values at optimum conditions in the shake flask and the bioreactor were found to be around 0.01 and 0.0117 s−1, respectively. Comparison of K L a values at optimum conditions shows that biosurfactant production scaling up from shake flask to bioreactor can be done with K L a as scale up criterion very accurately. Nearly 8% of original oil in place was recovered using this biosurfactant after water flooding in the sand pack.  相似文献   

13.
A simple and fast catalytic adsorptive stripping voltammetric procedure for trace determination of Cr(VI) in natural samples containing high concentrations of humic substances has been developed. The procedure for chromium determination in the presence of DTPA and nitrates was employed as the initial method. In order to enhance the selectivity vs. Cr(III) the measurements were performed at 40°C. Interference from dissolved organic matter such as humic and fulvic acids was drastically decreased by adding Amberlite XAD-7 resin to the voltammetric cell before the deaeration step. The whole procedure was applied to a single cell, which allowed monitoring of the voltammetric scan. Optimum conditions for removing humic and fulvic acids due to their adsorption on XAD-7 resin were evaluated. The use of XAD-7 resin also minimize interferences from various cationic, anionic, and nonionic surfactants. The calibration graph for Cr(VI) for an accumulation time of 30 s was linear in the range 5 × 10−10 to 5 × 10−8 mol L−1. The relative standard deviation for determination of Cr(VI) at a concentration of 1 × 10−8 mol L−1 was 3.5% (n = 5). The detection limit estimated from 3 times the standard deviation for low Cr(VI) concentrations and an accumulation time of 30 s was about 1.3 × 10−10 mol L−1. The proposed method was successfully applied to Cr(VI) determination at trace levels in soil samples.  相似文献   

14.
 An electrochemical study of the doxazosin oxidative process at carbon paste electrodes using different voltammetric techniques has been carried out. The process is irreversible and controlled by adsorption, giving rise to an oxidation wave around 1.0 V in citric acid-citrate buffer (pH 3.0). A mechanism based on the oxidation of the amine group is postulated. Two methods based on adsorptive stripping (AdS) of doxazosin at the C8-modified carbon paste electrode (C8-MCPE), before its voltammetric determination, are studied, using differential pulse voltammetry (DPV) and square wave voltammetry (SWV) as redissolution techniques. By means of AdS-DPV and C8-MCPE, doxazosin can be determined over the 1.0 × 10−9 to 3.0 × 10−8 mol L−1 range with a variation coefficient of 2.2% (2.0 × 10−8 mol L−1) and a limit of detection of 7.4 ×10−10 mol L−1. If AdS-SWV is used, a linear range from 1.0 × 10−9 to 4.0 × 10−8 mol L−1 is obtained, the variation coefficient being 2.8% (2.0 × 10−8 mol L−1, and the limit of detection reached 7.7 × 10−10 mol L−1. The AdS-DPV procedure was applied to the determination of doxazosin in urine and formulations. Received March 13, 1999. Revision December 23, 1999.  相似文献   

15.
A new spectrofluorimetric method was developed for the determination of trace amounts of coenzyme A (CoA). In the presence of periodic acid (H5IO6), CoA can remarkably enhance the fluorescence intensity of the Tb3+–ciprofloxacin (CIP) complex at 545 nm in a buffer solution at pH 5.4; the enhanced fluorescence intensity of the Tb3+ ion is proportional to the concentration of CoA. The optimal conditions for the determination of CoA were also investigated. The linear range and the detection limit for the determination of CoA were 6.08 × 10−6–1.64 × 10−5 and 2.1 × 10−8 mol L−1, respectively. This method is simple, practical and relatively free of interference from coexisting substances, and can be successfully applied to assess CoA in injection and biological samples. Moreover, the enhancement mechanism of the fluorescence intensity of the CoA–Tb3+–CIP system in the presence of H5IO6 is also discussed.  相似文献   

16.
 The electrocatalytic activity of an aluminum microelectrode modified with cobalt hexacyanoferrate film is described. A simple method was used for the preparation of the modified microelectrode. The modified microelectrode exhibits good electrocatalytic properties for electrochemical reduction of hydrogen peroxide. The effect of solution pH and applied potential on the electrocatalytic properties of the modified microelectrode is investigated. The results show that the best potential for the detection of hydrogen peroxide is 0.0 vs. SCE for better response and decrease of interferences. Due to the microelectrode scale, it can be used for the determination of small amounts of H2O2. The calibration plot is linear up to 1.7 mM (r = 0.988) with a response time of 5.1 s. The detection limit of the microelectrode as H2O2 sensor is 2 × 10−7 M. The sensivity of the H2O2 sensor is 225.6 nA mmol−1 and RSD of this sensor is less than 2.3%. In addition, effects of possible interferences and possibility of the sensor for real samples is investigated. The present work shows the potential of the proposed method for the fabrication of modified electrodes, as it can be used to employ for different purposes in micro scale. Received June 20, 2001; accepted June 14, 2002  相似文献   

17.
The hierarchy of the electron localization basins is a powerful tool of analysis of the bonding in molecules and solids within the “elfological” framework. It is a generalization of the molecular isodensity contour analysis originally proposed by Mezey. In this approach the basins are ordered with respect to the electron localization function values at the critical points which determine the reduction of the reducible localization domains. The procedure enabling the corresponding tree diagrams to be built is described and it is shown how the method can be used as a generator of mathematical definitions of chemical concepts. The possibility offered by this simple tool is illustrated by a study of the VO x and VO x + (x=1–4) oxides in their ground state and in some excited states. Received: 20 July 2000 / Accepted: 20 October 2000 / Published online: 23 January 2001  相似文献   

18.
A new Schiff-base ligand [N, N′, N″-Tri- (2,4-dihydroxyacetophenone) – triaminotriethylamine (TDATA)] with a tripodal structure was synthesized. Its fluorescence intensity with the europium(III) complex was increased about 178-fold in the presence of sodium acetate (NaAc) and about 126-fold in the presence of sodium phosphate (Na3PO4) solution. After adding the organic solvent dimethylsulfoxide (DMSO) to the above system, which leads to Eu3+ the fluorescence was further enhanced about 12-fold. Spectrofluorimetric determination of trace amounts of Eu3+ based on the phenomenon was performed. The excitation and emission wavelength is 365 nm and 615 nm, respectively. Under optimum conditions, the fluorescence intensities vary linearly with the concentration of Eu3+ in the range of 4.9 × 10−12–3.2 × 10−6 mol · L−1 with a detection limit of 4.5 × 10−12 mol · L−1 (for the TDATA-NaAc-DMSO system) or 6.2 × 10−11–8.6 × 10−6 mol · L−1 with a detection limit of 6.0 × 10−11 mol · L−1 (for the TDATA-Na3PO4-DMSO system). Interferences of some rare earth metals and other inorganic ions are described. The method is a selective, sensitive, rapid and simple analytical procedure for the determination of europium(III) in a high purity yttrium oxide and synthetic sample. The mechanism for the fluorescence enhancement is also discussed.  相似文献   

19.
The chemiluminescence (CL) of peracetic acid (PAA) in alkaline medium is very weak but is strongly enhanced after the addition of dihydralazine sulfate (DHZS). Based on this phenomenon, a simple, rapid and highly sensitive flow-injection CL method for the determination of DHZS was developed. The CL emission was linearly related to the DHZS concentration in the range of 20–4000 ng mL−1 with a detection limit (3σ) of 1.2 ng mL−1. As a preliminary application, the proposed method was successfully applied to the determination of DHZS in pharmaceutical preparations; the recovery of DHZS in human urine was between 96.5% and 102.2%. A detailed CL mechanism was proposed and singlet molecular oxygen (1O2) was suggested to be produced in the CL reaction process.  相似文献   

20.
Currently, there is an increasing demand for the production of biodiesel and, consequently, there will be an increasing need to treat wastewaters resulting from the production process of this biofuel. The main objective of this work was, therefore, to investigate the effect of applied volumetric organic load (AVOL) on the efficiency, stability, and methane production of an anaerobic sequencing batch biofilm reactor applied to the treatment of effluent from biodiesel production. As inert support, polyurethane foam cubes were used in the reactor and mixing was accomplished by recirculating the liquid phase. Increase in AVOL resulted in a drop in organic matter removal efficiency and increase in total volatile acids in the effluent. AVOLs of 1.5, 3.0, 4.5 and 6.0 g COD L−1 day−1 resulted in removal efficiencies of 92%, 81%, 67%, and 50%, for effluent filtered samples, and 91%, 80%, 63%, and 47%, for non-filtered samples, respectively, whereas total volatile acids concentrations in the effluent amounted to 42, 145, 386 and 729 mg HAc L−1, respectively. Moreover, on increasing AVOL from 1.5 to 4.5 g COD L−1 day−1 methane production increased from 29.5 to 55.5 N mL CH4 g COD−1. However, this production dropped to 36.0 N mL CH4 g COD−1 when AVOL was increased to 6.0 g COD L−1 day−1, likely due to the higher concentration of volatile acids in the reactor. Despite the higher concentration of volatile acids at the highest AVOL, alkalinity supplementation to the influent, in the form of sodium bicarbonate, at a ratio of 0.5–1.3 g NaHCO3 g CODfed−1, was sufficient to maintain the pH near neutral and guarantee process stability during reactor operation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号