首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The levels of contamination with various organochlorine pesticides (such as total HCH, heptachlor, heptachlor epoxide, aldrin, dieldrin, endrin, endosulfan, and total DDT) of different foods from 3 traditional markets were determined to estimate Taiwanese daily intake of organochlorine pesticides. Of the 18 organochlorine pesticides investigated, alpha-HCH, beta-HCH, lindane, delta-HCH, heptachlor, heptachlor epoxide, dieldrin, endrin, alpha-endosulfan, p,p'-DDE, and p,p'-DDT were detected at concentrations ranging from 0.26 to 10.2 ng/g wet weight. Contamination with organochlorine pesticides followed the order heptachlor > dieldrin > alpha-endosulfan > HCH isomers > heptachlor epoxide > DDT. Frequencies of detection of organochlorine pesticide residues ranged from 2.0 to 52.3%. alpha-Endosulfan was the most frequently detected organochlorine pesticide in the foods analyzed, followed by heptachlor epoxide (47.6%) and alpha-HCH (38.9%). Estimated daily intakes (EDIs) of organochlorine pesticides from foods were 1.137 micrograms for total HCH, 2.147 micrograms for heptachlor, 0.702 microgram for heptachlor epoxide, 0.624 microgram for endosulfan, 0.098 microgram for cyclodiene, and 0.541 microgram for total DDT. These EDIs were only 0.075% of the acceptable daily intake (ADI) for lindane, 47.5% of ADI for heptachlor and heptachlor epoxide, 0.045% of ADI for total DDT, and 1.01% of ADI for aldrin and dieldrin. Therefore, consumption of the foods analyzed does not pose a risk to consumer health.  相似文献   

2.
A coupled technique, microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), was investigated for one-step in situ sample pretreatment for organochlorine pesticides (OCPs) prior to gas chromatographic determination. The OCPs, aldrin, o,p'-DDE, p,p'-DDE, o,p'-DDT, p,p'-DDT, dieldrin, alpha-endosulfan, beta-endosulfan, endosulfan sulfate, endrin, delta-HCH, gamma-HCH, heptachlor, heptachlor epoxide, methoxychlor and trifluralin were collected by the proposed method and analyzed by gas chromatography with electron-capture detection (GC-ECD). To perform the MA-HS-SPME, six types of SPME fibers were examined and compared. The parameters affecting the efficiency in MA-HS-SPME process such as sampling time and temperature, microwave irradiation power, desorption temperature and time were studied to obtain the optimal conditions. The method was developed using spiked water samples such as field water and with 0.05% humic acid in a concentration range of 0.05-2.5 microg/l except endosulfan sulfate in 0.25-2.5 microg/l. The detection was linear over the studied concentration range with r2>0.9978. The detection limits varied from 0.002 to 0.070 microg/l based on S/N=3 and the relative standard deviations for repeatability were <15%. A certified reference sample of OCPs in aqueous solution was analyzed by the proposed method and compared with the conventional liquid-liquid extraction procedure. These results are in good agreement. The results indicate that the proposed method provides a very simple, fast, and solvent-free procedure to achieve sample pretreatment prior to the trace-level screening determination of organochloride pesticides by gas chromatography.  相似文献   

3.
Solid-phase microextraction (SPME) coupled with gas chromatography-mass spectrometry (GC-MS) was used to determine pesticide residues in Chinese herbal formulations. Fibers coated with a 100-microm film thickness of poly(dimethylsiloxane) was used to extract 19 organochlorine pesticides (OCPs). The pesticides in the study consisted of alpha-, beta-, gamma-and delta-hexachlorocyclohexane, p,p'-DDD, p,p'-DDE, p,p'-DDT, o,p'-DDT, aldrin, dieldrin, endrin, endrin aldehyde, endrin ketone, endosulfan (I, II and sulfate), heptachlor, heptachlor epoxide, and methoxychlor. The optimal experimental procedures for the adsorption and desorption of pesticides were evaluated. The linearity was obtained with a precision below 11% RSD for the studied pesticides expect endosulfan sulfate (21%) in a wide range from 1 to 200 ng/g. Detection limits were reached at below ng/g levels. Heptachlor epoxide was determined at a calculated limit of 0.03 ng/g. Comparison between SPME and Soxhlet extraction showed that SPME has a less than one order detection limit for residue pesticide determination. The proposed method was tested by analyzing herbal formulations from a local market for OCP multiresidues. Some residues studied were detected in the analyzed samples. The results demonstrate the suitability of the SPME-GC-MS approach for the analysis of multi-residue OCPs in Chinese herbal formulations.  相似文献   

4.
Levels of 14 organochlorine pesticide residues--1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (DDT) group (p,p'-DDT, o,p'-DDT, p,p'-DDD, and p,p'-DDE), HCH isomers (alpha-, beta-, and gamma-HCH), hexachlorobenzene (HCB), aldrin, dieldrin, endrin, heptachlor, alpha-endosulfan, and endosulfan sulfate--were evaluated in 127 samples of medicinal plants collected in pharmacies (78 samples) and herb stores (49 samples) in 1996. Samples were divided between 15 national brands and 7 foreign brands. Most samples sold in pharmacies contained residues of gamma-HCH (51.3%). All residues were detected in analyzed samples, with exception of endrin in herb store samples. Detection frequency varied between 51.3% for gamma-HCH and 1.3% for endrin in pharmacy samples, and between 34.7% for HCB and 4.1% for endosulfan sulfate in herb store samples. Maximum residue levels were exceeded in 38 (48.7%) pharmacy samples and in 26 (53.1%) medicinal herb store samples.  相似文献   

5.
搅拌棒吸附子萃取与GC-MS法测定水中20种有机氯农药   总被引:2,自引:0,他引:2  
建立了搅拌棒吸附子萃取/气相色谱-质谱法(SBSE/GC-MS)同时检测水中α-六六六、γ-六六六、β-六六六、七氯、δ-六六六、艾氏剂、环氧七氯、γ-氯丹、顺-氯丹、硫丹Ⅰ、p,p-滴滴伊、狄氏剂、异狄氏剂、p,p-滴滴滴、硫丹Ⅱ、p,p-滴滴涕、异狄氏剂醛、硫丹硫酸盐、甲氧滴滴涕、异狄氏剂酮20种有机氯农药含量的方法.样品在室温下经拌棒吸附子搅拌吸附,甲醇解吸附后,以J&W DB-35 MS(30 m×0.25 mm×0.25 μm)石英毛细管色谱柱为分析柱,气相色谱-质谱选择离子流模式检测.考察了萃取时间、氯化钠及甲醇加入量等对萃取的影响.实验结果表明:在2.5 ~20.0 μg/L 范围内,20种有机氯农药呈良好的线性关系,检出限(S/N=3)为0.008 ~0.118 μg/L,水样中分别添加2.5、20 μg/L的20种有机氯农药,回收率为 52% ~117%,相对标准偏差小于13%(n= 6).该方法操作简便、快速、灵敏度高,应用于实际样品检测,结果满意.  相似文献   

6.
A rapid multiresidue extraction method for organochlorinated pesticides from fish feed was developed, which is based on the extracted fat treatment by n-hexane, concentrated sulphuric acid and ENVI-carb, a graphitized non-porous carbon material. The final residue, obtained in about 50 min, was dissolved in isooctane and analysed by gas chromatography with an electron capture detector (GC/ECD). The presence of the extracted pesticides was confirmed by gas chromatography-mass spectrometry (GC/MS). Concentration of sulphuric acid and amount of ENVI-carb were optimized in order to improve analytes recovery, accuracy and detection limits. This simple and relatively fast method allowed a high recovery of the HCB, Lindane, HEPO, p,p'-DDE, p,p'-DDD, p,p'-DDT residues, with mean values in the range 68-124% at four fortification levels (12.5, 25.0, 50.0, 100.0 ng/g), and coefficients of variation between 1.9 and 20.2%. Detection limit were equal to 3.0 ng/g, related to fat, for all pesticides, and calibration curves were linear (r > 0.999) in the range of explored concentrations from the detection limit to 100 ng/g. For all pesticides a good repeatability was obtained (CV% values in the range 0.23-4.16%) when a sequence of six injections of the isooctane extraction solution was performed. The usefulness of the proposed method has been tested by the analysis of fish feed samples.  相似文献   

7.
袁宁  余彬彬  张茂升  曾景斌  陈曦 《色谱》2006,24(6):636-640
建立了微波辅助萃取-固相微萃取-气相色谱(MAE-SPME-GC)同时测定茶叶中六六六(α-BHC,β-BHC,γ-BHC,δ-BHC 4种异构体)、滴滴涕类(DDD,DDE,o,p′-DDT,p,p′-DDT)、氯氰菊酯(cypermethrin)和氰戊菊酯(fenvalerate)等10种农药残留的方法。采用外标法定量,除氰戊菊酯外,农药的质量浓度与其色谱峰面积在一定范围内有较好的线性关系,相关系数为0.9705~0.9984。10种组分的加标回收率为64%~121%,相对标准偏差为10.4%~22.9%,检测限为1~50 ng/L。应用该方法测定了市场上3种茶叶中上述农药残留的含量。  相似文献   

8.
The main objective of this work is to develop a routine quality control method for pesticide residues in cocoa beans, using gas chromatography-mass spectrometry. The investigated pesticides, which are used to control pests in the growing of cacao, are: Acephate, Propoxur, HCH, Heptachlor, Fenitrothion, Pirimiphos-methyl, Aldrin, Dieldrin, pp'-DDE, op-DDE and DDT. Two extraction methods were tested. The first was based on strong attack by concentrated sulphuric acid and later extraction with n-hexane: the investigated residues were Acephate, HCH, Fenitrothion and DDT; recoveries were 68-95% and the detection limits 0.5-10 ppb. The second extraction method was based on the Universal Trace Residue Extractor (UNITREX), which consists of a distillation system for organophosphorus and organochlorine pesticides in fatty samples. The investigated residues were Heptachlor, Pirimiphos-methyl, Aldrin, Propoxur, Dieldrin, op-DDE and pp'-DDE; recoveries were 67-88% and the detection limits 1-10 ppb.  相似文献   

9.
阎正  封棣  李申杰  赵亚奎  杨慧 《色谱》2005,23(3):308-311
建立了中草药中有机氯类农药残留量的固相萃取-毛细管气相色谱(SPE-CGC)分析方法。对丹参、黄芩、射干、白芍、白芷、天南星、牛蒡子、知母、桔梗共9种中草药中六六六的4种异构体、滴滴涕的4种异构体、七氯、艾氏剂、环氧七氯、狄氏剂、异狄氏剂共13种有机氯农药的残留量进行了测定。以丙酮-正己烷混合物作提取剂,采用超声波提取样品,然后用Florisil固相萃取小柱快速净化提取物。采用SPB-5弹性石英毛细管气相色谱柱分离样品,电化学检测器进行检测。13种农药的峰面积与其质量浓度均有良好的线性关系,相关系数均大于0.998。最小检测量为0.064~0.61 μg/L;样品的加标回收率为87.3%~102.3%(相对标准偏差为1.3%~6.8%)。该法简便快速、灵敏准确,具有广泛的应用前景。  相似文献   

10.
Zhang M  Huang J  Wei C  Yu B  Yang X  Chen X 《Talanta》2008,74(4):599-604
A new approach for the extraction of nine kinds of organochlorine pesticides (OCPs) from vegetable samples coupling single-drop microextraction with gas chromatography-mass spectrometry was presented. Experimental parameters, such as organic solvent, exposure time, agitation and organic drop volume were controlled and optimized. An effective extraction was achieved by suspending a 1.00microL mixed drop of p-xylene and acetone (8:2, v/v) to the tip of a microsyringe immersed in a 2mL donor aqueous solution and stirred at 400rpm. The approach was applied to the determination of OCPs in vegetable samples with a linearity range of 0.05-20ng mL(-1) for alpha-, beta-, gamma-, delta-hexachlorobenzene (BHC) and dicofol, 0.5-20ng mL(-1) for dieldrin and 2,2-bis(4-chlorophenyl)-1,1-dichloroethane (DDD) or 0.5-50ng mL(-1) for 2,2-bis(4-chlorophenyl)-1,1-dichloroethylene (DDE) and 2-(2-chlorophenyl)-2 (4-chlorophenyl)-1,1,1-trichloroethane (p,p'-DDT). Correspondingly, the determination limit at an S/N of 3 ranged from 0.05ng mL(-1) for alpha-, beta-, gamma-, delta-BHC to 0.2ng mL(-1) for dicofol, dieldrin or p,p'-DDT. The relative recoveries were from 63.3 to 100%, with repeatability ranging from 8.74 to 18.9% (relative standard deviation, R.S.D.). The single-drop microextraction was proved to be a fast and simple approach for the pre-concentration of organochlorine pesticides in vegetable samples.  相似文献   

11.
A simple method is described for the quantitative determination of organochlorine pesticides and polychlorinated biphenyls (PCB's) in water at the sub-ppb level. A micro gas-phase extractor advantageously replaces other preconcentration and purification techniques. The extract is analyzed by capillary gas chromatography without further enrichment. The recovery at the ppb level was nearly 100% for organochlorine pesticides and more than 80% for PCB's. The complete procedure including sample preparation, steam distillation-extraction, and capillary gas chromatographic analysis is carried out in less than four hours.  相似文献   

12.
A selective pressurized liquid extraction (SPLE) procedure capable of performing simultaneous extraction and clean-up has been demonstrated for multi-residue analysis of organochlorine pesticides (OCPs) in soil. The final method was performed at 100 degrees C for 3 x 10 min using acetone/n-heptane (1:1, v/v). Florisil was placed inside the extraction cell downstream the sample to remove interfering compounds. Extraction of two soil samples by SPLE gave a recovery which was over 80% for beta-endosulfan, endosulfan sulfate, p,p'-DDT and p,p'-DDE compared to PLE with off-line clean-up. The same trend was observed when applying the SPLE method to a certified reference soil sample (CRM 811-050) containing 13 OCPs, where the SPLE method gave 80-90% recovery vis-à-vis the PLE method with off-line clean-up. Feasibility of the SPLE method was further demonstrated by applying it to five real soil samples collected in Ethiopia.  相似文献   

13.
A method for determination of concentrations of polychlorinated biphenyl congeners (PCB-28, 52, 101, 118, 138, 153, 156, and 187) and organochlorine pesticides (hexachlorobenzene, alpha-hexachlorocyclohexane, beta-hexachlorocyclohexane, gamma-hexachlorocyclohexane, delta-hexachlorocyclohexane, p,p'-dichlorodiphenyl dichloroethylene, o,p'-dichlorodiphenyl trichloroethane, p,p'-dichlorodiphenyl dichloroethane, p,p'-dichlorodiphenyl trichloroethane, alpha-chlordane, gamma-chlordane, heptachlor, heptachlor epoxide, and aldrin) in human serum is developed. Recovery is assessed with artificial serum, in which PCBs and OCPs could not be detected. The method is then confirmed with pooled human serum. Experiments are performed by adding two concentrations of analytes (0.5 μg/L and 1.0 μg/L) to both matrices. The sample pretreatment process involves denaturing with a mixture of water-1-propanol (v:v, 85:15), extraction with a C-18 cartridge, and cleanup with an Alumina B cartridge. This process required about 2 mL of serum. The limit of detection ranged from 0.05-0.35 μg/L for all the analytes. Recovery of analytes at low and high spiking concentrations varied from 63-122% and 61-124% for artificial serum and pooled human serum, respectively. Relative standard deviation was lower than 16% and 18% for artificial serum and pooled human serum, respectively. Stability of the method, expressed as relative standard deviation, was lower than 14%. The method has been applied in epidemiological research.  相似文献   

14.
A method involving depuration of 12 organochlorine pesticides (OCPs) from Radix codonopsis was developed using supercritical fluid extraction (SFE). The pesticides investigated in the study included alpha-, beta-, gamma- and delta-benzene hexachloride, PCNB (pentachloro-nitrobenzene), PCA (pentachloroaniline), HEPT (heptachlor), MPCPS (methyl-pentachlorophenyl sulfide), pp'-DDE [1,1-dichloro-2, 2-bis(p-chlorophenyl) ethylene], op'-DDT [1,1,1-trichloro-2-(o-chlorophenyl)-2-(p-chlorophenyl)ethane], pp'-DDD [1,1-dichloro-2-2-bis(p-chlorophenyl)ethane] and pp'-DDT [1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane]. A series of experiments was conducted to optimize the final extraction conditions as follows: pure CO2, extraction pressure 15 MPa, extraction temperature 60 degrees C, extraction time 20 min and flow rate 55 mL/h. A GC method with electron capture detection was employed for the determination of the OCPs in Radix codonopsis. An HPLC method was developed for the quantitative determination of active constituents. SFE was used to remove the organochlorine pesticide from Radix codonopsis. The results showed that at least 93.5% of the organochlorine pesticide residues in the herb sample were removed by SPE, while 95.0% of the active constituent marker (atractylenoide III) remained.  相似文献   

15.
食用菌中19种农药的多残留分析   总被引:2,自引:0,他引:2  
建立了食用菌中19种农药残留量的气相色谱分析方法.样品用乙腈提取,提取液浓缩后用弗罗里硅土柱净化,经HP-5石英毛细管柱分离后,采用GC-ECD同时测定19种农药残留量.六六六、DDT各4种异构体及同系物的质量浓度在0.01 ~1 mg/L范围内,其他11种农药在0.01 ~5 mg/L范围内,均有良好线性关系.相关系数r大于0.997,样品在3个添加水平时的回收率为80% ~115%,相对标准偏差为1.1% ~10%.检出限为0.43 ~2.9 μg/kg.方法简便、快速、净化效果较好,可同时满足进、出口食用菌中多种农药残留量的检测需要.  相似文献   

16.
G H Tan 《The Analyst》1992,117(7):1129-1132
Solid-phase extraction (SPE) of organochlorine pesticide residues from environmental water samples was evaluated using octadecyl (C18)-bonded porous silica. The efficiency of SPE of these pesticide residues from reagent water samples at 1-5 micrograms dm-3 levels was compared with those obtained by solvent extraction with hexane and Freon TF (trichlorotrifluoroethane). Average recoveries exceeding 80% for these organochlorine pesticides were obtained via the SPE method using small cartridges containing 100 mg of 40 microns C18-bonded porous silica. The average recovery by solvent extraction with hexane and Freon TF exceeded 90% in both instances. It was concluded that the recoveries and precision for the SPE of organochlorine pesticides were poorer than those for the solvent extraction method. Organochlorine pesticide residue levels in environmental water samples from two major rivers flowing through predominantly rice-growing areas were monitored by gas chromatography using the solvent extraction method with hexane. Exceptionally high levels of organochlorine pesticide residues such as BHC, DDT, heptachlor, endosulfan and dieldrin were found in these water samples.  相似文献   

17.
Summary Gas chromatography of polychlorinated biphenyls and chlorinated pesticides in water samples has been performed after adsorption from a 50–250 mL sample on to a cartridge containing 100 mg cyanopropyl-bonded porous silica. The PCBs are desorbed with 500 μL ethyl acetate, which is concentrated and analysed by gas chromatography with electron-capture detection (GC-ECD). The average recovery of 1 ppb PCB congeners at from distilled water and from Marta river water is ≥95% (standard deviation ≤2.5). The average recovery of 20 ppb Aroclor 1260 from Marta river water was ≥91% (standard deviation ≤3.5). In the separation of the PCBs from the chlorinated pesticides only aldrin, heptachlor and 4,4′-DDD are adsorbed with the PCBs by the CN Sep-Pak cartridge. The method proposed is rapid, simple and reproducible.  相似文献   

18.
Different extraction methods were evaluated for the determination of fifteen organochlorine pesticides (OCPs) in water and sediments. Liquid-liquid extraction (LLE) was evaluated for the pesticides analyses in water while Soxhlet extraction (SE) and microwave assisted extraction (MAE) methods were compared in sediment. Of all the extracting solvents used, dichloromethane gave the best results. Percentage recoveries ranged from 71.03 +/- 8.15 (dieldrin) to 101.25 +/- 2.17% [a-benzenehexachloride (alpha-BHC)] in water with LLE. In sediments the percentage recoveries with Soxhlet extraction method varied between 88.22 +/- 7.85 (endrin) and 109.63 +/- 5.10% (beta-BHC) and ranged from 74.11 +/- 9.82 (2,4 DDT) to 97.50 +/- 4.56% (alpha-BHC) with MAE. The limits of detection for the OCPs ranged from 5.5 to 20.6 ng/l and between 0.6 and 2.1 ng/g. respectively. The LLE and the SE methods were applied to water and sediments samples, respectively, from marine and freshwater sources in the Eastern Cape Province of South Africa that receive runoffs from agricultural lands and effluents from industries. The levels of OCPs ranged from 5.5 (2,4-DDD) to 450 +/- 0.10 ng/l (beta-BHC) in water samples and from 0.6 (aldrin and 2,4-DDD) to 184 +/- 0.12 ng/g (beta-BHC) in sediments for triplicate analyses. Some endocrine disrupting OCPs such as DDT, DDE, heptachlor, endosulphan and the chlordanes were detected.  相似文献   

19.
TiO(2) nanotubes, novel nanomaterials synthesized from hydrothermal treatment, were investigated for being used as a new solid-phase extraction adsorbent with o,p'-DDT, [1,1,1-trichloro-2-(o-chlorophenyl)-2-(p-chlorophenyl)ethane, p,p'-DDT, [1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane] and its principle metabolites p,p'-DDD, [1,1-dichloro-2,2-bis(4-chlorophenyl)ethane] and p,p'-DDE [1,1-(2,2-dichloro-ethanylidene)-bis(4-chlorobenzene)] as the target analytes. Several factors such as eluant and its volume, the sample pH, sample volume and the flow rate of samples, were optimized. The effect of humic acid, which is often present in natural water system, was also investigated. Under the optimal conditions, lower detection limits of 0.0031, 0.0037, 0.0053 and 0.0025 ng mL(-1) for p,p'-DDD, p,p'-DDT, o,p'-DDT and p,p'-DDE, respectively, were obtained. The proposed method was successfully applied to the analysis of the target compounds in several environmental water samples. Good recoveries over the range of 81.2-115% were obtained. These results indicated that titanium nanotubes had enormous potential in environmental field as a novel SPE adsorbent material.  相似文献   

20.
加压溶剂萃取-气相色谱法测定荞麦中残留的有机氯农药   总被引:2,自引:1,他引:1  
廉玫  许峰  观文娜  徐媛  关亚风 《色谱》2008,26(4):484-488
用所研制的24位全自动加压溶剂萃取仪(APLE),以丙酮-正己烷(体积比为1∶1)为溶剂,在100 ℃和10 MPa条件下,对荞麦样品中残留的7种有机氯农药进行了萃取,并通过气相色谱对萃取液进行定量分析。萃取的绝对回收率为68%~126%,相对标准偏差为1.2% ~14.7%,检测下限为0.051~0.18 ng/g。与索氏提取法对比,相对提取回收率为116%~148%,表明萃取收率高于索氏提取法。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号