首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the simultaneous quantification of 20 cocaine, amphetamine, opiate, and nicotine analytes in meconium, the first neonatal feces, by liquid chromatography tandem mass spectrometry was developed and validated. Specimen preparation included methanol homogenization and solid phase extraction. Two injections were required to achieve sufficient sensitivity and linear dynamic range. Linearity ranged from 0.5–25 up to 500 ng/g (250 ng/g p-hydroxymethamphetamine), and correlation coefficients were >0.996. Imprecision was <10.0% CV, analytical recovery 85.5–123.1%, and extraction efficiencies >46.7% at three concentrations across the linear range. Despite significant matrix effects of −305.7–40.7%, effects were similar for native and deuterated analytes. No carryover, endogenous or exogenous interferences were observed, with analyte stability at room temperature, 4 °C, and −20 °C and on the autosampler >70%, except for 6-acetylmorphine, hydrocodone, oxycodone, and morphine. Method applicability was demonstrated by analyzing meconium from drug-exposed neonates.  相似文献   

2.
A rapid confirmatory method has been developed and validated for the simultaneous identification, confirmation and quantitation of 11 nitroimidazoles in eggs by liquid chromatography tandem mass spectrometry (LC–MS/MS). The method is validated in accordance with Commission Decision 2002/657/EC and is capable of analysing metronidazole (MNZ), dimetridazole (DMZ), ronidazole (RNZ), ipronidazole (IPZ) and their hydroxy metabolites MNZ-OH, HMMNI (hydroxymethyl, methyl nitroimidazole), IPZ-OH. The method is also capable of analysing carnidazole (CRZ), ornidazole (ORZ), tinidazole (TNZ) and ternidazole (TRZ). MNZ, DMZ and RNZ have been assigned a recommended level (RL) of 3 μg kg−1 by the Community Reference Laboratory (CRL) in Berlin. The developed method described in this study is easily able to detect all the nitroimidazole compounds investigated at this level and below. Egg samples are extracted with acetonitrile, and NaCl is added to help remove matrix contaminants. The acetonitrile extract undergoes a liquid–liquid wash step with hexane; it is then evaporated and reconstituted in mobile phase. The reconstituted samples are analysed by liquid chromatography tandem mass spectrometry (LC–MS/MS). The decision limits (CCα) range from 0.33 to 1.26 μg kg−1 and the detection capabilities (CCβ), range from 0.56 to 2.15 μg kg−1. The results of the inter-assay study, which was performed by fortifying hen egg samples (n = 18) on three separate days, show the accuracy calculated for the various analytes to range between 87.2 and 106.2%. The precision of the method, expressed as %CV values for the inter-assay variation of each analyte at the three levels of fortification (3, 4.5 and 6.0 μg kg−1), ranged between 3.7 and 11.3%. A Day 4 analysis was carried out to examine species variances in eggs from different birds such as duck and quail and investigating differences in various battery and free range hen eggs.  相似文献   

3.
Amadori compounds are aroma precursors formed in the initial phase of the Maillard reaction. Based on their similar structures, simultaneous quantification of more than six Amadori compounds in tobacco has not been reported yet. In this study, a simple and rapid method was developed to simultaneously quantify ten Amadori compounds including the isomers of Fructose‐isoleucine and Fructose‐leucine in tobacco. The separation was performed on an Atlantis T3 column (2.1 × 250 mm, 5 μm) by gradient elution using acetonitrile and water as the mobile phases. The quantification method was systematically evaluated and proven to be sensitive and accurate. The linearity was good, with correlation coefficients of 0.9977–0.9999. The limits of detection and quantitation were 1.354–2.532 and 4.516–8.444 ng/mL, respectively. The recoveries were 84.0–119.6%, and the relative standard deviations were 1.33–5.40%. The method was used to analyze the changes in the amounts of ten Amadori compounds in tobacco before and after tobacco primary processing. The analysis shows that the Maillard reaction occurs during the short processing period.  相似文献   

4.
A new, rapid, and sensitive liquid chromatography with tandem mass spectrometry method was developed for the determination of vitisin B and validated in rat plasma and urine using carbamazepine as an internal standard. The plasma (0.05 mL) or urine (0.2 mL) samples were extracted by liquid–liquid extraction with ethyl acetate and separated on an Eclipse Plus C18 column (100 × 4.6 mm, 3.5 μm) with a mobile phase consisting of acetonitrile and 0.1% formic acid water (60:40, v/v) at a flow rate of 0.7 mL/min. Detection and quantification were performed by mass spectrometry in selected reaction‐monitoring mode with positive electrospray ionization. The calibration curves were recovered over the concentration ranges of 10?5000 ng/mL (correlation coefficients, r≥0.9833) in plasma and 5?2500 ng/mL (r≥0.9977) in urine, respectively. All validation data, including the specificity, precision, accuracy, recovery, and stability, conformed to the acceptance requirements. No matrix effects were observed. The developed method was successfully applied to pharmacokinetic studies of vitisin B following intravenous administration of 0.5 and 1 mg/kg and intraperitoneal injection of 5, 10, and 25 mg/kg to rats. This is the first report on the pharmacokinetic properties of vitisin B. The results provide a meaningful basis to evaluate preclinical or clinical applications of vitisin B.  相似文献   

5.
A sensitive and specific liquid chromatography with tandem mass spectrometry method was firstly developed for the measurement of isomangiferin in rat plasma. Chloramphenicol was selected as the internal standard. Sample preparation was carried out through a simple one‐step protein precipitation procedure with methanol. Negative electrospray ionization was performed using multiple reaction monitoring mode with transitions of m/z 421.1/301.1 for isomangiferin, and 321.1/151.9 for chloramphenicol. The calibration curve was linear over the range of 0.1–600 ng/mL, with a lower limit of quantification at 0.1 ng/mL. The intra‐ and interday precisions (relative standard deviation) were no more than 8.2% and accuracies (relative error) were within the range of –8.4 to 2.2%. The recovery, matrix effect and stability under different conditions were all proved acceptable. The validated method has been successfully applied to a preclinical pharmacokinetic study of isomangiferin in rats for the first time.  相似文献   

6.
A sensitive, simple and reliable analytical method based on a modified quick, easy, cheap, effective, rugged, safe sample preparation and liquid chromatography with tandem mass spectrometry detection was developed for the simultaneous determination of amicarbazone and its two major metabolites desamino amicarbazone and isopropyl‐2‐hydroxy‐desamino amicarbazone residues in grains (rice, wheat, corn, buckwheat) and soybean. Several parameters, including liquid chromatography and tandem mass spectrometry conditions, extraction approaches and the adsorbents for clean‐up, which might influence the accuracy of the method, were extensively investigated. The established method was further validated by determining the linearity (R2 > 0.99), fortified recovery (79–118%), precision (1–12%) and sensitivity (limit of quantification, 5 μg/kg for amicarbazone and desamino amicarbazone, and 10 μg/kg for isopropyl‐2‐hydroxy‐desamino amicarbazone). Finally, the established method was successfully applied to determine the residues of amicarbazone and its metabolites in 49 real samples of grain and soybean.  相似文献   

7.
For the determination of the in vitro cytochrome P450 activity in microsomes, a quantification method for the probe metabolites, formed during incubation, is required. Due to insufficient sensitivity of a previously developed high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for some of the metabolites, a fast and easy derivatization method with pyridine-3-sulfonyl chloride (PS) is described. Acetaminophen (CYP1A2), dextrorphan (CYP2D6), hydroxy-chlorzoxazone (CYP2E1) and hydroxy-mephenytoin (CYP2C19) can be derivatized because of the presence of a phenolic OH, whereas hydroxy-midazolam (CYP3A4) and hydroxy-tolbutamide (CYP2C9) remain unchanged. As PS improves the ionization efficiency in the positive electrospray ionization (ESI) mode, the sensitivity of the detection is improved significantly and meets requirements for the activity determination. Native negative electrospray type molecules, moreover, become positive ESI candidates. The direct derivatization in the aqueous incubation medium, without any other sample pre-treatment steps, such as evaporation or extraction, makes this procedure easy to perform. The method using 20s microwave irradiation was shown to equal a 10min reaction in a 60°C heating block, consequently simplifying and shortening the process. Collision induced fragmentation of the derivatives resulted in at least one native compound, rather than derivative, specific product ion, thereby improving the selectivity of the method in the multiple reaction monitoring mode. The HPLC-MS/MS method was validated, and was demonstrated to be sensitive, selective, precise and accurate. The absence of a relative matrix effect was established, notwithstanding that an absolute matrix effect was observed. The analysis of a sample after microsomal incubation, from which some of the metabolites could not be quantified using the method without derivatization, proved the usefulness of the method.  相似文献   

8.
Yonkenafil is a promising drug for treatment of male erectile dysfunction. Previous studies showed that the piperazine‐N,N’‐deethylation metabolite, piperazine‐N‐deethylation metabolite, and piperazine‐N‐deethylation‐N,N’‐deethylation metabolite were the major metabolites of yonkenafil after extensive metabolism. We developed a sensitive and selective method for the simultaneous quantification of yonkenafil and its major metabolites using high‐throughput liquid chromatography with tandem mass spectrometry. Analytes and internal standard were extracted from a small quantity of plasma (50 μL) using liquid–liquid extraction with diethyl ether/dichloromethane (60:40, v/v), and the baseline separation was achieved on Zorbax SB‐C18 column using ammonia/water/methanol (0.2:20:80, v/v/v) as the mobile phase. The assay was performed with an electrospray positive ionization mass spectrometry through the multiple‐reaction monitoring mode within 2 min. Calibration curve of the method was linear within the range of 1.00–1000 ng/mL for all the analytes with the intra‐ and interday precisions of 4.0–5.2 and 4.0–5.3% for yonkenafil, 3.1–4.9 and 3.1–5.2% for the piperazine‐N,N’‐deethylation metabolite, 4.8–6.8 and 4.8–7.3% for the piperazine‐N‐deethylation metabolite, and 2.9–6.1 and 5.4–6.3% for the piperazine‐N‐deethylation‐N,N’‐deethylation metabolite, respectively. The recoveries were above 90% with low matrix effects. The validated assay was successfully applied to support a preclinical pharmacokinetic study in six rats using a single oral dose of yonkenafil (8 mg/kg).  相似文献   

9.
A rapid and sensitive liquid chromatography with tandem mass spectrometry method has been developed and validated for the simultaneous quantification of 11 major compounds in Yuanhu‐Bazhi herb‐pair from a rat intestinal perfusion experiment, including eight alkaloids and three coumarins using diazepam as the internal standard. The analysis was performed on an Agilent Poroshell 120EC‐C18 column using a gradient elution of acetonitrile/H2O with 0.0015% formic acid and 2 mM ammonium formate buffer additive (pH 4.2). All compounds were detected by tandem mass spectrometry in positive ionization mode and quantified using multiple reaction monitoring mode. Good linearity in the related range of each compound was presented. The validation data, such as accuracy and precision, were within the required limits. The lower limit of quantification of each analyte was less than 10 ng/mL. Intra‐day and inter‐day precisions were less than 12.84%. The relative errors of accuracy were in the range of –13.31 to 13.19%. The recoveries of analytes were greater than 84.08%. The method has been successfully applied to an intestinal absorption study of major components following intestinal perfusion of Yuanhu‐Bazhi herb‐pair extract to rats.  相似文献   

10.
Zeng D  Shen X  He L  Ding H  Tang Y  Sun Y  Fang B  Zeng Z 《Journal of separation science》2012,35(10-11):1327-1335
A rapid liquid chromatography tandem mass spectrometric method was developed for the simultaneous determination of mequindox and its five metabolites (2-isoethanol mequindox, 2-isoethanol 1-desoxymequindox, 1-desoxymequindox, 1,4-bisdesoxymequindox, and 2-isoethanol bisdesoxymequindox) in porcine muscle, liver, and kidney, fulfilling confirmation criteria with two transitions for each compound with acceptable relative ion intensities. The method involved acid hydrolysis, purification by solid-phase extraction, and subsequent analysis with liquid chromatography tandem mass spectrometry using electrospray ionization operated in positive polarity with a total run time of 15 min. The decision limit values of five analytes in porcine tissues ranged from 0.6 to 2.9 μg/kg, and the detection capability values ranged from 1.2 to 5.7 μg/kg. The results of the inter-day study, which was performed by fortifying porcine muscle (2, 4, and 8 μg/kg), liver, and kidney (10, 20, and 40 μg/kg) samples on three separate days, showed that the accuracy of the method for the various analytes ranged between 75.3 and 107.2% with relative standard deviation less than 12% for each analyte.  相似文献   

11.
A high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantification of zidovudine in rat plasma. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 268/127 for zidovudine and m/z 230/112 for the internal standard. The method exhibited a linear dynamic range of 5-500 ng/mL for zidovudine in rat plasma. The lower limit of quantification was 5 ng/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 1.5 min for each sample made it possible to analyze more than 400 plasma samples per day. The validated method was applied for pharmacokinetic studies of the novel drug delivery systems of zidovudine in rats.  相似文献   

12.
A simple and rapid method for determining ethylenebisdithiocarbamates (EBDCs; mancozeb, maneb, and zineb) in fruits and vegetables is described. EBDCs are transformed into dimethylethylenebisdithiocarbamate (EBDC-dimethyl) by methylation after their decomposition with ethylenediaminetetraacetic acid (EDTA). These processes were performed simultaneously in this method. Dimethyl sulfate was used as the methylation reagent, and acetonitrile extracts obtained from partitioning with anhydrous magnesium sulfate and sodium chloride were subjected to dispersive solid-phase extraction with the primary secondary amine sorbent. Liquid chromatography with tandem mass spectrometry in the positive heated-electrospray ionization mode was used for the determination of EBDC-dimethyl produced from EBDCs. The method was validated at levels of 10, 50, and 100 ng g−1 maneb as a representative EBDC. The recoveries of the present method were between 71 and 101%. The limits of detection and quantification were 0.24 and 0.8 ng g−1 maneb, respectively.  相似文献   

13.
Though liquid chromatography electrospray tandem mass spectrometry (LC-ESI-MS2) has been widely used in the structural elucidation of triacylglycerols (TAG) in vegetable oils, its potentiality for the identification of TAG molecules in omega-3 rich oils remains unexplored till date. Hence, this article investigates the applicability of LC-ESI-MS2 for the structural characterization of naturally occurring TAG in cod liver oil without the TAG fractionation during the sample preparation. A computational algorithm was developed to automatically interpret the mass spectra and elucidate the TAG structures respectively. The results were compared against the lipase benchmark method. A principal component analysis study revealed that it is possible to discriminate genuine from adulterated cod liver oil.  相似文献   

14.
A sensitive high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of quetiapine in rat plasma. Following liquid-liquid extraction, the analyte was separated using a gradient mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 384 to m/z 221 for quetiapine and m/z 327 to m/z 270 for the internal standard. The assay exhibited a linear dynamic range of 0.25-500 ng/mL for quetiapine in rat plasma. The lower limit of quantification was 0.25 ng/mL with a relative standard deviation of less than 7%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated method was successfully used to analyze rat plasma samples for application in pre-clinical pharmacokinetic studies. This method in rodent plasma could be adapted for quetiapine assay in human plasma.  相似文献   

15.
A method for detection of semicarbazide (SEM) in baby food was validated. SEM was extracted with hydrochloric acid and derivatised with 2-nitrobenzaldehyde, using [15N2,13C] semicarbazide as internal standard. The extract was neutralised, purified on a solid phase extraction cartridge and SEM was determined by reversed phase LC-MS-MS. Linearity was demonstrated in the ranges from 0.1 ng ml(-1) to 1 ng ml(-1) and from 2 ng ml(-1) to 80 ng ml(-1). Matrix effects were non significant for meat-based and significant for apple and rice-based baby foods, in both ranges. Mean recoveries ranged from 87.8% to 107.2% with relative standard deviation from 0.2% to 9.1%, considering both ranges. Limits of detection and quantification were 0.1 microg kg(-1) and 0.25 microg kg(-1), respectively. The results of the validation process demonstrated the method suitability for use in food control.  相似文献   

16.
The development of a multi-method for the detection of seven allergens based on liquid chromatography and triple-quadrupole tandem mass spectrometry in multiple reaction mode is described. It is based on extraction of the allergenic proteins from a food matrix, followed by enzymatic digestion with trypsin. The chosen marker peptides were implemented into one method that is capable of the simultaneous detection of milk, egg, soy, hazelnut, peanut, walnut and almond. This method has been used to detect all seven allergenic commodities from incurred reference bread material, which was baked according to a standard recipe from the baking industry. Detected concentrations ranged from 10 to 1000 μg/g, demonstrating that the mass spectrometric based method is a useful tool for allergen screening.  相似文献   

17.
A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono‐hexsosyl ceramide groups with good peak area repeatability (RSD% < 10) and linearity (R2 > 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co‐existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage.  相似文献   

18.
Antimicrobials are used in large quantities in human and veterinary medicine. Their environmental occurrence is of particular concern due to the potential spread and maintenance of bacterial resistance. After intake by the organisms, the unchanged drug and its metabolized forms are excreted and enter wastewater treatment plants where they are mostly incompletely eliminated, and are therefore eventually released into the aquatic environment. The reliable detection of several antimicrobials in different environmental aqueous compartments is the result of great improvements achieved in analytical chemistry. This article provides an overview of the more outstanding analytical methods based on liquid chromatography tandem mass spectrometry, developed and applied to determine antimicrobial residues and metabolites present in surface, waste, and ground waters.   相似文献   

19.
A high‐throughput, rapid, and efficient modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method with a simple cleanup procedure has been developed for simultaneously determining 227 pesticides in pepper samples by liquid chromatography with tandem mass spectrometry (running time: 10 min). Pesticide residues were extracted/partitioned with an acetonitrile/DisQuE QuEChERS pouch, and the resulting samples were cleaned up with different methods: dispersive solid‐phase extraction with primary secondary amines or multiwalled carbon nanotubes and graphitized carbon solid mini cartridge column. The results indicated that multiwalled carbon nanotubes dispersive sorbents achieved the best recoveries and had less matrix interference. The numbers of pesticides with a recovery in the range of 70–120% were 199 at a spiked level of 40 μg/kg. The correlation coefficients (r2) for 227 pesticides were above 0.99, while the limits of quantitation of pesticides in pepper samples ranged from 0.13 to 13.51 μg/kg (S/N = 10), and the limits of detection ranged from 0.04 to 4.05 μg/kg (S/N = 3). The relative standard deviations of approximately 197 pesticides were below 20% at spiked levels of 40 μg/kg. Based on these results, the proposed method was chosen as the most suitable cleanup procedure for the determination of multiresidue pesticides in pepper samples.  相似文献   

20.
Tongkat Ali (Eurycoma longifolia) is one of the most popular traditional herbs in Southeast Asia and generally consumed as forms of dietary supplements, tea, or drink additives for coffee or energy beverages. In this study, the liquid chromatography with tandem mass spectrometry method for the simultaneous quantitation of six major quassinoids of Tongkat Ali (eurycomanone, 13,21‐dihydroeurycomanone, 13α(21)‐epoxyeurycomanone, 14,15β‐dihydroxyklaineanone, eurycomalactone, and longilactone) was developed and validated. Using the developed method, the content of the six quassinoids was measured in Tongkat Ali containing dietary supplement tablets or capsules, and the resulting data were used to confirm the presence of Tongkat Ali in those products. Among the six quassinoids, eurycomanone was the most abundant quassinoid in all samples tested. The developed method would be useful for the quality assessment of Tongkat Ali containing dietary supplements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号