首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Characteristic ion mobility spectra for volatile compounds present in fat were used to authenticate the feeding regime of Iberian pigs. Volatile compounds were obtained by heating the solid samples at 150 degrees C for 40 min. This produced a headspace that was introduced in the spectrometer ionization chamber by means of a highly purified nitrogen stream. The spectra thus, obtained for the fat samples were processed chemometrically in order to assess their usefulness for discriminating meat from free-range pigs fed on pasture and acorns and confined pigs fed with commercial feed including high-oleic acid products. Principal component analysis was used as both an exploratory tool and a variable reduction method, and linear discriminant analysis was employed to classify 65 subcutaneous fat samples according to pig feeding regime. Only 2.3% of the samples from pigs reared in confinement were misclassified. 95.5% of the free-range samples were correctly predicted.  相似文献   

2.
The processing procedure can alter the nature and chemical transformation of traditional Chinese medicine to accommodate different clinical dispensing and preparation requirements. In this study, static headspace‐multicapillary column with gas chromatography coupled to ion mobility spectrometry was developed for the rapid and sensitive discrimination of crude and processed traditional Chinese medicine. Using Radix Paeoniae Alba as a traditional Chinese medicine model, the combined power of this approach was illustrated by classifying the crude and processed Radix Paeoniae Alba samples into two main categories. The contents of the main components in Radix Paeoniae Alba varied significantly. The established method could promote the use of ion mobility spectrometry in intrinsic quality control and differentiation of herbal medicines from other processed products or preparations.  相似文献   

3.
We report results of studies of global and targeted neuronal metabolomes by ambient pressure ion mobility mass spectrometry. The rat frontal cortex, striatum, and thalamus were sampled from control nontreated rats and those treated with acute cocaine or pargyline. Quantitative evaluations were made by standard additions or isotopic dilution. The mass detection limit was ~100 pmol varying with the analyte. Targeted metabolites of dopamine, serotonin, and glucose followed the rank order of distribution expected between the anatomical areas. Data was evaluated by principal component analysis on 764 common metabolites (identified by m/z and reduced mobility). Differences between anatomical areas and treatment groups were observed for 53 % of these metabolites using principal component analysis. Global and targeted metabolic differences were observed between the three anatomical areas with contralateral differences between some areas. Following drug treatments, global and targeted metabolomes were found to shift relative to controls and still maintained anatomical differences. Pargyline reduced 3,4-dihydroxyphenylacetic acid below detection limits, and 5-HIAA varied between anatomical regions. Notable findings were: (1) global metabolomes were different between anatomical areas and were altered by acute cocaine providing a broad but targeted window of discovery for metabolic changes produced by drugs of abuse; (2) quantitative analysis was demonstrated using isotope dilution and standard addition; (3) cocaine changed glucose and biogenic amine metabolism in the anatomical areas tested; and (4) the largest effect of cocaine was on the glycolysis metabolome in the thalamus confirming inferences from previous positron emission tomography studies using 2-deoxyglucose.
Figure
Instrumental schematic of an ion mobility mass spectrometer used for measuring changes in neuronal metabolomes of varying anatomical regions. Two-dimensional data is generated for each anatomical area of interest  相似文献   

4.
Pyrolysis gas chromatography-differential mobility spectrometry (py-GC-DMS) analysis of E. coli, P. aeruginosa, S. warneri and M. luteus, grown at temperatures of 23, 30, and 37 degrees C, provided data sets of ion intensity, retention time, and compensation voltage for principal component analysis. Misaligned chromatographic axes were treated using piecewise alignment, the impact on the degree of class separation (DCS) of clusters was minor. The DCS, however, was improved between 21 to 527% by analysis of variance with Fisher ratios to remove chemical components independent of growth temperature. The temperature dependent components comprised 84% of all peaks in the py-GC-DMS analysis of E. coli and were attributed to the pyrolytic decomposition of proteins rather than lipids, as anticipated. Components were also isolated in other bacteria at differing amounts: 41% for M. luteus, 14% for P. aeruginosa, and 4% for S. warneri, and differing patterns suggested characteristic dependence on temperature of growth for these bacteria. These components are anticipated to have masses from 100 to 200 Da by inference from differential mobility spectra.  相似文献   

5.
Ion mobility spectrometry (IMS) measurement combined with unsupervised neurocomputing is considered as a new potential method for on-line monitoring of fermentation and other processes producing volatile compounds that involve micro-organisms. This was demonstrated in a model system in which a strain of brewer’s yeast (Saccharomyces cerevisiae) was cultivated in a bench-top fermenter. Five phases of yeast growth could be detected from measurements of the exhaust gases from the fermenter, as indicated by the changes in ion mobility spectra analysed by computational methods.The data were first processed using the Self-Organizing Map (SOM) algorithm, the results showing that the phases of fermentation can be detected and identified. The cultivations were also shown by Sammon’s mapping to be comparable to a certain level of accuracy. Contaminated cultivation could be detected by its distinctive ion mobility spectrometry profile.  相似文献   

6.
Hyphenation of micro-liquid and ultra-performance liquid chromatography with a hybrid (QqTOF) tandem mass spectrometry was studied from the viewpoint of their applicability for monitoring of anthocyanin dyes in various cultivars and different vintages of red wine. After appropriate optimization both techniques proved to be suitable for this task. UHPLC system provided lower LOD and LOQ values as well as higher productivity and precision of retention parameters and peak areas with respect to micro-LC method. On the other hand, micro-LC method offers significant savings of mobile phase, less contamination of ion source of mass spectrometer and makes the nebulization process in electrospray much easier. In combination with principal component analysis (PCA), the method allows to elucidate long-term relations in a complete set of certified red wine cultivars grown in South Moravia (certified in Czech Republic until year 2005). Among the studied varieties Rubinet exhibit a specific anthocyanin profile. Especially interesting is a high content of 3-coumaroylglucoside-5-glucosides of malvidin and peonidin. Those dyes can be used as markers of artificial color enhancement. Principal component analysis applied to data processed with regard to enzymatic activity markedly facilitate classification among varieties. This approach allows resolution of teinturiers, variety Blaufränkish and partial classification of other varieties.  相似文献   

7.
This paper reports the first investigation of electron capture ion mobility spectrometry as a detection method for capillary gas chromatography. In previous work with negative ion mobility detection after gas chromatography, the principal reactant ion species were O2? or hydrated O2? due to the presence of oxygen in the drift gas. These molecular reactant ions have a mobility similar to chloride and bromide ions, which are the principal product ions formed by most halogenated organics via dissociative ion-molecule reactions. Oxygenated reactant ions thus interfere with the selective detection of chloride and bromide product ions. A recently described ion mobility detector design efficiently eliminated ambient impurities, including oxygen, from infiltrating the ionization region of the detector; consequently, in the negative mode of operation, the ionization species with N2 drift gas were thermalized electrons. Thermalized electrons have a high mobility and their drift time occupies a region of the ion mobility spectrum not occupied by chloride, bromide, or other product ions. The result was improved selectivity for halogenated organics which ionize by dissociative electron capture. This was demonstrated by the selective detection of 4,4′-dibromobiphenyl from the components of a polychlorinated biphenyl mixture (Aroclor 1248).  相似文献   

8.
Human breath analysis is a powerful and especially a non-invasive technique for the monitoring and hopefully also for the diagnosis of respiratory diseases, including chronic obstructive pulmonary disease (COPD). The exhaled breath of 95 patients suffering COPD and of 35 healthy controls was investigated using an Ion Mobility Spectrometer (IMS) coupled to a Multi-Capillary Column (MCC) without any pre-separation or pre-enrichment. Starting with the results from a Mann–Whitney-Wilcoxon rank sum test to find analytes with the highest potential with respect to differentiation, box and whisker plots, metabolic maps and probability charts were introduced and compared. In addition, the sensitivity, specificity, positive and negative predictive values and the accuracy of the relation were also summarized. The findings were compared to the results of a principal component analysis. Finally, decision trees were introduced to visualize the interdependencies between the analytes and the classifications. The application of these biostatistical methods with simultaneous inclusion of several VOCs for disease classification by ion mobility spectrometry of human breath will provide much more information than using single peaks and single concentration dependencies for disease classification and discrimination of various groups. Towards the future application of potential biomarkers for clinical diagnostic procedures, complex analytical methods, such as ion mobility spectrometry, need statistical and bioinformatical tools which are simple in application, visualize the results and support decisions on the basis of the data obtained from measurements of analytes in exhaled human breath.  相似文献   

9.
Time‐of‐flight SIMS (ToF‐SIMS) imaging offers a modality for simultaneously visualizing the spatial distribution of different surface species. However, the utility of ToF‐SIMS datasets may be limited by their large size, degraded mass resolution and low ion counts per pixel. Through denoising and multivariate image analysis, regions of similar chemistries may be differentiated more readily in ToF‐SIMS image data. Three established denoising algorithms—down‐binning, boxcar and wavelet filtering—were applied to ToF‐SIMS images of different surface geometries and chemistries. The effect of these filters on the performance of principal component analysis (PCA) was evaluated in terms of the capture of important chemical image features in the principal component score images, the quality of the principal component score images and the ability of the principal components to explain the chemistries responsible for the image contrast. All filtering methods were found to improve the performance of PCA for all image datasets studied by improving capture of image features and producing principal component score images of higher quality than the unfiltered ion images. The loadings for filtered and unfiltered PCA models described the regions of chemical contrast by identifying peaks defining the regions of different surface chemistry. Down‐binning the images to increase pixel size and signal was the most effective technique to improve PCA performance. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

10.
Ion mobility-mass spectrometry is starting to be considered as a useful tool in the deconvolution of complex oil and petroleum samples. While ultrahigh resolution mass spectrometry is the incumbent technology in this field, ion mobility offers complementary information related to species size and shape, and also the ability to resolve structural isomers. In this work, a sample of the resins portion of the Saturates, Aromatics, Resins, and Asphaltenes (SARA) fractions of crude oil was analysed using an orthogonal acceleration quadrupole time-of-flight mass spectrometer (oa-QToF MS) that incorporates a travelling wave ion mobility spectrometry (TWIMS) region. The ion mobility data were compared with previously acquired ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) data and various nitrogen containing families were identified. Ion mobility data were processed in the typical way for the oil and petroleum industry; and the use of high resolution exact mass coupled with mobility data to provide enhanced species resolution was examined. Double bond equivalence (DBE) and carbon number groups were identified using patterns in the ion mobility data, which demonstrated the utility of ion mobility for discovering species relationships within the crude oil sample. The ability to calibrate the ion mobility cell and generate sizes for the detected ions was also recognised as potentially having particular value for the implementation of conversion or hydrotreatment processes in the oil industry.  相似文献   

11.
The potential of a vanguard technique as is the ion mobility spectrometry with ultraviolet ionization (UV-IMS) coupled to a continuous flow system (CFS) have been demonstrated in this work using a gas phase separator (GPS). This vanguard system (CFS-GPS-UV-IMS) has been used for the analysis of different types of white wines to obtain a characteristic profile for each type of wine and their posterior classification using different chemometric tools. Precision of the method was 3.1% expressed as relative standard deviation. A deep chemometric study was carried out for the classification of the four types of wines selected. The best classification performance was obtained by first reducing the data dimensionality by principal component analysis (PCA) followed by linear discriminant analysis (LDA) and finally using a k-nearest neighbour (kNN) classifier. The classification rate in an independent validation set was 92.0% classification rate value with confidence interval [89.0%, 95.0%] at 95% confidence level.The same white wines analyzed using CFS-GPS-UV-IMS were analyzed using gas chromatography with a flame detector (GC-FID) as conventional technique. The chromatographic method used for the determination of superior alcohols in wine samples shown in the Regulation CEE 1238/1992 was selected to carry out the analysis of the same samples set and later the classification using appropriate chemometrics tools. In this case, strategies PCA-LDA and kNN classifier were also used for the correct classification of the wine samples. This combination showed similar results to the ones obtained with the proposed method.  相似文献   

12.
气相色谱/离子阱质谱中组分图谱提取的主成分分析方法   总被引:2,自引:0,他引:2  
苏越  廖远熹  郭寅龙 《化学学报》2007,65(14):1377-1380
由于离子阱质谱中容易发生分子-离子反应, 致使质谱图发生改变, 影响与主要由四极质谱建立的参照图谱的匹配效果. 本文采用主成分分析方法对气相色谱/离子阱质谱中组成色谱峰的所有全扫描质谱进行提取, 提取后的质谱图能够有效克服分子-离子反应和基线干扰的影响, 应用不同的匹配算法均能很好地和参照图谱匹配, 和传统方法相比匹配度显著提高, 对目标化合物定性准确.  相似文献   

13.
主成分分析同时单点pH络合滴定法   总被引:6,自引:0,他引:6  
张大伦 《分析化学》1996,24(7):820-823
  相似文献   

14.
In the present study, comprehensive 2D GC—TOF‐MS combined with multivariate data analysis was applied to analyze the differences of the volatile components in crude and processed Atractylodis Macrocephalae Rhizoma (AMR) samples. As a result, 26 compounds that were found in crude AMR samples disappeared in processed AMR samples, and 19 compounds were newly generated and identified in AMR after processing with wheat bran. Meanwhile, principal component analysis demonstrated that there were significant chemical differences between crude and processed AMR samples, and processing procedure caused obvious quantitative and qualitative changes of volatile components in AMR. The established method could be used to explain the chemical differentiation between crude and processed AMR, and to further understand the processing mechanism of herbal medicines.  相似文献   

15.
Comprehensive analysis of fatty alcohol ethoxylates has been conducted by coupling ultra high pressure hydrophilic interaction chromatography and ion mobility spectrometry mass spectrometry. A custom‐designed sub‐2 μm column was used for the chromatographic separation of fatty alcohol ethoxylates by hydrophilic interaction chromatography. Ion mobility spectrometry provided a post‐ionization resolution during a very short period of 6.4 ms. Distinguishable families of singly, doubly, and triply charged fatty alcohol ethoxylates were clearly observed. By virtue of the combination of hydrophilic interaction chromatography and ion mobility spectrometry, comprehensive resolution based on both hydrophobicity difference and mobility disparity has been achieved for fatty alcohol ethoxylates. The orthogonality of the developed separation and analysis system was evaluated with the correlation coefficient and peak spreading angle of 0.0224 and 88.72°, respectively. The actual peak capacity obtained was individually 40 and 193 times than those when hydrophilic interaction chromatography and ion mobility spectrometry were used alone. The collision cross‐sections of fatty alcohol ethoxylates were calculated by calibrating the traveling wave ion mobility device with polyalanine.  相似文献   

16.
In traditional Chinese medicine, raw and processed herbs are used to treat different diseases. Suitable quality assessment methods are crucial for the discrimination between raw and processed herbs. The dried fruit of Arctium lappa L. and their processed products are widely used in traditional Chinese medicine, yet their therapeutic effects are different. In this study, a novel strategy using high‐performance liquid chromatography and diode array detection coupled with multivariate statistical analysis to rapidly explore raw and processed Arctium lappa L. was proposed and validated. Four main components in a total of 30 batches of raw and processed Fructus Arctii samples were analyzed, and ten characteristic peaks were identified in the fingerprint common pattern. Furthermore, similarity evaluation, principal component analysis, and hierachical cluster analysis were applied to demonstrate the distinction. The results suggested that the relative amounts of the chemical components of raw and processed Fructus Arctii samples are different. This new method has been successfully applied to detect the raw and processed Fructus Arctii in marketed herbal medicinal products.  相似文献   

17.
This paper demonstrates a novel operating mode of an ion mobility detector (IMD) for obtaining both qualitative and quantitative data after capillary gas chromatographic separation of 5,5′-disubstituted barbiturates. Using a recently developed time dispersive Fourier transform method for ion mobility spectrometry, complete ion mobility spectra could be obtained for each component in the chromatogram. This type of spectra can be used for providing qualitative information on unknown compounds or for selecting the proper detector conditions needed when operating in the continuous mobility monitoring mode. In this study each of the five barbiturates investigated produced a Fourier transformed ion mobility spectrum containing one major product ion. When drift times corresponding to those of the product ions measured in the FT mode were monitored continuously, selective chromatographic detection of the barbiturates was achieved. In one case even isomers could be differentiated based on mobility characteristics.  相似文献   

18.
19.
Current commercially available ion mobility spectrometers are intended for the analysis of chemicals in the gas phase. Sample introduction methods, such as direct air sampling, a GC injector or a thermal desorber, are commonly an integral part of these instruments. This paper describes an electrospray ionization ion mobility spectrometer system that allows direct introduction samples in solution phase. This allows direct analysis of non-volatile organic and biological samples, and avoids decomposition of thermally liable samples, providing reliable chemical identification. In addition, the new ion mobility spectrometer allows mobility analysis with high resolving power. Commonly used commercial IMS systems provide resolving powers between 10 and 30; this new ion mobility spectrometer has resolving power greater than 60 for routine analysis. A high resolution instrument is necessary for many applications where a complex mixture needs to be separated and quantified. This paper demonstrates the advantages of using a high resolution ion mobility spectrometer and an electrospray ionization source for the analysis of non-volatile pharmaceuticals as well as dissolved explosive in solution phase.  相似文献   

20.
Analytical methods based on multiplug filtration cleanup coupled with pulse glow discharge‐ion mobility spectrometry and liquid chromatography tandem mass spectrometry were developed for the analysis of tricaine mesylate residue in fish and fish‐raising water samples. A silica fiber holder and an appropriate new interface were designed to make the direct introduction of the fiber into the pulse glow discharge‐ion mobility spectrometry introduction mechanism. The multiplug filtration cleanup method with adsorption mixtures was optimized for the determination of tricaine mesylate in fish samples. Good linear relationships were obtained by the two methods. For fish samples, limits of detection were 6 and 0.6 μg/kg by ion mobility spectrometry and liquid chromatography with tandem mass spectrometry, respectively. The matrix effect of the established liquid chromatography tandem mass spectrometry method was negligible for fish samples but that of the ion mobility spectrometry method was not. The two methods were compared. The ion mobility spectrometry system could be used a rapid screening tool on site with the advantage of rapidity, simplicity, and portability, and the liquid chromatography tandem mass spectrometry system could be used for validation in laboratory conditions with the advantage of lower limit of detection, stability, and precision.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏